Tender For B.O.Q For Eltn Component Of Hss Trenz, Shopian Part-1 B.W.O Electric Work
Tender Value
2.40 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
7 days left
EMD
4800
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Shopian → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Eltn Component Of Hss Trenz, Shopian Part-1 B.W.O Electric Work
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/fan point/exhaust fan point/call bell point with 2 × 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, conforming to IS 694, with conductors as per IS 8130 and insulation as per IS 5831, and having fire performance in accordance with IEC 60332, ISI marked with valid BIS license, complete with all accessories , ( Havell/ Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor or OEMs/ firms holding ISO 9001 certification (Quality Management System) and shall be supplied with routine test certificates, and any material not conforming to the specified standards shall be rejected , complete with all accessories as required; single core cable in surface / recessed medium class PVC conduit ( including cost of conduit), with modular switch ( Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group-A |
| 3 | Group-C |
| 4 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit ( including cost of conduit) |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.) |
| 6 | Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit,( including cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 3 pin 5-10 A modular socket outlet and 2 no. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.) |
| 8 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. 3 pin 5/6A socket outlet |
| 9 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. Indicator |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 , single core cable in surface/ recessed medium class PVC conduit as required. Including cost of conduit. |
| 11 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Lighting Circuit) |
| 12 | S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve ,Schneider / Legrand /ABB, / Havells ,/ Siemens/ L&T / Hager /BCH make OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer in charge. |
| 13 | 6-32 Amp SP MCB |
| 14 | 32 amp DP MCB |
| 15 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates. |
| 16 | Supplying and fixing following way, Horizontal type,Single pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 17 | 12 way , Double door |
| 18 | Supply installation testing and commissioning of 12 W LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W . The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt. approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures also. (Philips/ Havel's /Wipro make / sample to be approved before installation). |
| 19 | Supply, installation, testing and commissioning of 1 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections. |
| 20 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make. |
| 21 | S/Laying ( partly overhead/ partly underground) , testing and commissioning of XLPE aluminum armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. Havell/Eq. standard make as directed by engineer in charge and making end termination with brass compression gland and aluminum lugs of required size. |
| 22 | 25 sq.mm 3.5 core ( armoured) |
| 23 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) 5 panels |
| 24 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 25 | Normal INCOMING: |
| 26 | Adj. TMR Based MCCB 63 Amps DP Icu=Ics=100% Breaking Capacity 16 KA ROH Legrand/ Shinider/Semiens/ABB make. |
| 27 | b) 2 No. of Aluminium Bus Bar of 100 Amp. |
| 28 | c)Digital meters and phase indicators -1 set. |
| 29 | OUTGOING: |
| 30 | 32 amp DP MCB c curve 10 K Legrand/ Shinider acti-9/ABB make, sample to be approved before installation.. |
| 31 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit then embedding 2.5 mtr. Long GI earthing electrode, 60 mm dia. Connecting the electrode with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender