Tender For Construction Of Common Collection Point (Ccp) For Bio-Medical Waste Management (Bmw) Of Mmch, Paschim Medinipur -- Electrical Work.
Tender Value
4.32 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
8 days left
EMD
8641
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Medinipur West → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Common Collection Point (Ccp) For Bio-Medical Waste Management (Bmw) Of Mmch, Paschim Medinipur -- Electrical Work.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. [DSR(E&M)2025/P3/1.10] |
| 2 | Group C |
| 3 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required.[DSR(E&M)2025/P8/1.33] |
| 4 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. [DSR(E&M)2025/P6/1.22] |
| 5 | 180 mm X 100 mm X 60 mm deep |
| 6 | 200 mm X 150 mm X 60 mm deep |
| 7 | Supplying and fixing 415V, 63A, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Havells / Standard) [NS] |
| 8 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.[DSR(E&M)2025/P3/1.14] |
| 9 | 2 X 1.5 sqmm + 1 X 1.5 sqmm earth wire. |
| 10 | 2 X 6 sqmm + 1 X 6 sqmm earth wire |
| 11 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) [DSR(E&M)2025/P14/2.3] |
| 12 | 12 way, Double door |
| 13 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [DSR(E&M)2025/P15/2.12] |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [DSR(E&M)2025/P15/2.10] |
| 15 | Single pole |
| 16 | Supply of 2/4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make : Havells/ Gloster/ Polycab/ KEI] [NS] |
| 17 | 2 core 10 sqmm |
| 18 | 2 core 6 sqmm |
| 19 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.. [DSR(E&M)2025/P66/10.1.1] |
| 20 | Upto 35 sq. mm |
| 21 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. [DSR(E&M)2025/P66/10.7] |
| 22 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 23 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [DSR(E&M)2025/P68/11.1] |
| 24 | 2 X 6 sq. mm (19mm) |
| 25 | 2 X 10 sq. mm (19mm) |
| 26 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)[DSR(E&M)2025/P46/8.9] |
| 27 | 18- 22 Watt |
| 28 | Supply and delivery of Heavy Duty Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC /Crompton/Orient/havells) |
| 29 | 12\\"( 300 mm ) Speed 1420 RPM |
| 30 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required [DSR(E&M)2025/P10/1.49] |
| 31 | Making hole for installation of exhaust fan of size upto 450mm sweep by demolishing brick work manually/by mechanical means including disposal of malba within 50 meters lead and making good the wall by plastering etc. as required. (DSR Civil-2014 item no. 15.7.4 and 13.1.2) |
| 32 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. [DSR(E&M)2025/P10/1.50] |
| 33 | Upto 450 mm sweep |
| 34 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes [DSR(E&M)2025/P10/1.51] |
| 35 | Supplying and fixing 4way MCB SS enclosure with IP-20/30 protection, powder coated provision for 250V, 1no. 2channel Programmable Digital timer switch-24 hrs with minimum switching of 15 minute, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. [NS] |
| 36 | Supply & Delivery 3\\" dia. 2 Mtr. Long heavy gauge G.I. Pipe (minipole) having 9” X 9” X 1/2\\" M.S. sole plate welded with drilled hole at bottom of the pole to be installed on roof of building with S.F. grounding bolts. Including providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, with Supply & fixing 50mm Dia 1.5mtr long detachable type GI Single arm bracket suitable for the pole head.The arm brfacket shall be properly welded with 5mm thick stifner plate of pole sleeve for strengthening including properly fixing arfangement with the pole by bolt , nut, wahser as per direction of EIC incl painting RO primer over 2 coat Aluminium paint. [NS] |
| 37 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250V, 15A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [NS] |
| 38 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). [DSR(E&M)2025/P51/8.13] |
| 39 | 72 watt |
| 40 | S&F of 240V Timer DB equivalent to (12 + 2) way SPN double door make DB with SS enclosure phosphitised powder coated incl din rail with IP - 43 protection comprises with 1 nos 32 A DP MCB (C Curve,10 KA) 1 nos 24 hours programmable Time Switch with minimum switching time of 15 minutes, 1 nos 25 A 2 pole power contactor complete with outer cover plate & internal wiring by 4 sqmm copper wire 1 nos. Auto Manual bypass toggle switch ,earthing attachment incl 1 nos LED indication light for running condition & locking arrangement. (Make : LT / ABB/ Schneider/ siemens) |
| 41 | Supply & Installation of LED Sign Board, Designing, Fabrication, Supply, Installation, Testing & Commissioning of Outdoor LED Signage (Approximate Size:14' Length X 4' height) in English/Bengali (letters given and approved by concerned department) for letters with following specifications-(a) The box for the signage will be fabricated in Aluminum Square tube of size 25 mm. X 25 mm. of 16 gauge frame complete with necessary priming and painting. The box will be covered with 3 mm. thick Aluminium Composite Panel (ACP) sheets of the entire board. The complete installation will be water, vermin and dust insulated and protected.(b) Letter Description: Approx 9\\" x 5\\" size of letters (Approx) made of Aclrylic Sheet with male female attachment, on router cut ACP Sheet of front incl. all accessories as required. The Designed must be pre approvedfrom the EIC.(c) LED Illumination:High Bright, High Wave length closed type waterproof white LED modules (0.72 W or Higher) mounted on interior side of female part of letter with power wire running back to a central power area with 12 Volt LED Power Transformer to adequately drive the whole LED modules without Flicker.(d )Internal Electrical Wiring will be done by Halogen Free Flame Retardent HRFR compound insulated (Unsheathed) 1.5 Sq.mm. copper flexible cable through interior conduit and Electrical Raceway.(e)Erection the above sign board with three nos. 40x40x6mm MS angle iron support rigidly grouted on suitable muffing which are making on the ground to avoid the uprooting by wind pressure and painting as per direction of EIC. [NS] |
| 42 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. [DSR(E&M)2025/P30/5.2] |
| 43 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. [DSR(E&M)2025/P31/5.15] |
| 44 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. [DSR(E&M)2025/P32/5.18] |
| 45 | Note:1) The rates should be quoted in % above, % below or AaPar whichis inclusive of cost of maintenance, servicing, supply & replacement of spares for 1 (one) years from the date of commissioning.2) The Agency must procure the materials from the manufacture/OEM or their authorised sales Channel so that the standard warranty/support of the manufacturerer/OEM becomes applicable to the product to be delivered and installed by them. Documents that authenticate such procurement from the manufacturer/OEM or from their authorised sales Channel and standard warranty/support should be sent from the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. If any refubrished materials are supplied and installed, penal action will be taken as per existing rule. Before execution of the work the prospective bider has to submit layout drawing as per design of OEM dully approved by the OEM. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender