Drinking Water Supply and Sanitation Government Departments Closing in 27 days TDR #58402881

Tender For All In One Bid For Installation Of Belma-Ii New Solar Mini Rli Scheme Under Block- Keshiary Block In The District Of Paschim Medinipur Under The Executive Engineer (Am), Midnapore (Am) Division Under Core-Sector Program For The Financial Y

Issued by Government Departments · Medinipur West, West Bengal
Tender Value
26.99 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
27 days left
EMD
53994
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Medinipur West → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for All In One Bid For Installation Of Belma-Ii New Solar Mini Rli Scheme Under Block- Keshiary Block In The District Of Paschim Medinipur Under The Executive Engineer (Am), Midnapore (Am) Division Under Core-Sector Program For The Financial Year 2026-27.

BOQ

Name of Work:- All in One Bid for Installation of BELMA-II New Solar MINI RLI Scheme under Block- KESHIARY BLOCK in the District of Paschim Medinipur under the Executive Engineer (AM), Midnapore (AM) Division under Core-Sector Program for the Financial Year 2026-27.
Sl. No. Item Description
1PART – A [LAYING OF WATER TRANSMISSION ARRANGEMENT AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.] Please see the details in Sheet (WTA)
2PART – B [PROCUREMENT OF MATERIAL AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.] Please see the details in Sheet (PROCUREMENT OF MATERIAL)
3PART – C [SOLAR PHOTOVOLTAIC AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.] Please see the details in Sheet (SOLAR SYSTEM)
4PART – D [FORMATION OF WUA AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.] Please see the details in Sheet (WUA) Please Enable Macros to View BoQ information
5PART – A [LAYING OF WATER TRANSMISSION ARRANGEMENT AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.]
6Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
7Earthwork in excavation in the canals / drainage channels / borrow pits /River bed / slope of bank as noted below as per designed section & throwing the spoils in layers of 25 cm for making banks as per profile or to deposit the same in any other place within an initial lead of 30 metreand initial lift of 1.5 metre including breaking clods, rough dressing etc.complete as per direction of the Engineer-in-charge. (a) Ordinary soil / local soil / soil mixed with moorum or kankar / silt, dry or moist / slushy silt / stickysoil.
8Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge.a) 140 mm dia PVC Pipe
9b) 110 mm dia PVC Pipe
10Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)
11Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
12Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
131:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
141:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
15Centering and shuttering including strutting, propping etc. and removalof form work for : 4.3.1 Foundations, footings, bases for columns
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.(i)For foundation Blocks of Water Distribution System
17Tile brick masonry with common burnt clay F.P.S. (non modular) tilebricks of class designation 10 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
18Half brick masonry with common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
1915 mm cement plaster on rough side of single or half brick wall finishedwith a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand)
20Labour charges for fitting and fixing and laying , where necessary of fowlling M.S/G.I. /E.R.W pipes and accessories (to be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., maintaing the proper alignment and level / all complete / as per direction of E-I-C. (i) 150 mm. dia. G.I Pipe.
21(ii) 100 mm dia. G.I Pipe.
22Erection, fitting, fixing of set of M S Tripod inlet and outlet pipe fittings for MDTW / MINI RLI Scheme.(Rate inclusive of transportation from departmental store to work site).
23Labour charges for fitting, fixing110 mm. Dia. Alfa-AIfa valve with 140mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.
24Labour charges for fitting, fixing (150 x 140) mm dia M S reducer with 110 mm dia UPVC pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and 110 mm dia UPVC pipe with coupler and flanged end of tail piece and expander with rubber insertion, nuts and bolts etc. complete. (Rate inclusive of transportation from departmental store to work site).
25Labour charges for fitting & fixing of 150 & 100 mm dia Sluice Valve.
26Supplying, fitting and fixing including transportation of sign board for identifing the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC.
27b) Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge.iii) For Mini R.L.I. CPWD Item Sub - Total = WRI&Ddand I&WD Item Sub - Total = Add Carriage @ 4% excluding Earthwork
28Modified Estimated cost after using correction factor on DSR 2023 on account of GST @ 0.973 as per Office Memorandum vide e file No. :9158977, File No.- 158/SE (TAS)/GST/2024/02-E, Dated - 08.08.2024 of the Superintending Engineer (TAS) of CPWD(CPWD Item Sub Total Amount- x 0.973)
29Cost indices of Paschim Medinipore as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is - {CPWD Item Sub Total Amount- x 0.973)x1.09} Add GST @ 18% Labour welfare Cess @1% Grand Total Rs. Say Rs
30PART – B [PROCUREMENT OF MATERIAL AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.]
31UPVC PIPES & ACCESSORIES :140 mm. dia P.V.C. pipe Class- I 140 (with a loose matching coupler, class- II) marking IS No. 4985/ 1988 with latest amendments with free solvent cement.
32110 mm. dia P.V.C. pipe Class- I (with a loose matching coupler, class- II) marking IS No. 4985/ 1988 with latest amendments with free solvent cement.
33110 mm. dia P.V.C. pipe Class-II (with a loose matching coupler, class- II) marking IS No. 4985/ 1988 with latest amending with free solvent cement.
34Coupler (Cl-II) for 140 mm. dia P.V.C. pipe (extra) I.S. 10124/1988, Part- II with free solvent cement.
35Coupler (Cl-II) for 110 mm. dia P.V.C. pipe (extra) I.S. 10124/1988, Part- II with free solvent cement.
36110 x 110 x 110 M. P.V.C. Tee with free solvent cement
37140 x 140 x 140 M. P.V.C. Tee with free solvent cement
38140 x 110 Reducer (Cl- II) with free solvent cement.
39140 mm. dia 900 Bend (Cl-II) (IS. No. 10124 / 88 Part- 8 with latest amendment)
40110 mm. dia 600 Bend (Cl-II) (IS. No. 10124 / 88 Part- 8 with latest amendment)
41110 mm. dia 900 Bend (Cl-II) (IS. No. 10124 / 88 Part- 8 with latest amendment)
42140 mm. dia IS. NO. 10124 / 88 Part- 4 with latest amendment End Cap.
43110 mm. dia IS.NO.10124/88 Part-4 with latest amendment. PVC End Cap. (Cl-III)
44110 mm. dia (IS. No 10124/88 Part- 6 with latest amendment) F.T.P. (Cl-II)
45140 mm. dia (IS. No 10124/88 Part- 6 with latest amendment) F.T.P. (Cl-II)
46100 mm dia PVC flexible Hose Pipe ISI Marked IS 15265
47Solvent Cement extra (Medium duty)
48M.S / G.I ACCESSORIES :G.I set for Distribution Chamber, Tripod set for Mini RLI
49150 mm dia G.I. Pipe with flange as per IS 1239 (Part-I) / 2004 & 6392 / 1971, table 17 Specification.
50100 mm dia G.I. Pipe with flange as per IS 1239 (Part-I) / 2004 & 6392 / 1971, table 17 Specification.
51150 mm. dia I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 Sluice Valve .
52100 mm dia C.I. Sluice Valve I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 Sluice Valve .
53Ф100 mm Alfa-Alfa Valve as per technical specification
54100 x 80 mm M.S. flanged Reducer
55150 mm dia 90 degree G.I Bend (both end flang FdJ-ISImarked-IS 1239,Galv- IS4736
56M.S Foundation Bolt for Pump Motor sets (1.1kg each)
57M.S Foundation Bolt for Distribution Chamber (1.1kg each)
58Galvanized Nuts & Bolts IS: 1363 (Part 1 & 3) / 1992 of Product Grade-C.M-20 x 80 mm
59M-20 x 100 mm
60M-16 x 65 mm
61M-16 x 80 mm
62M-16 x 50 mm
63Foot valve Leather Washer 100 mm dia
64Compresed Asbestos fibre jointing for Quadruped & Tripod set(for raised surface of Flange as per IS-6392)300 mm. dia (Table-5)
65Rubber Insertion I.S. 638 / 79 with latest amendment sheet 5 mm. 2 Ply.(for raised surface of Flange as per IS-6392)150 mm dia Ruber Insertion (Table-17)
66150 mm dia Ruber Insertion (Table-5)
67100 mm dia Ruber Insertion (Table-17)
6880 mm dia Ruber Insertion (Table-17) Total Rs. Labour welfare Cess @1% Total Rs. Say Rs
69PART – C [SOLAR PHOTOVOLTAIC AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.]
70Solar Module: Supply , transport , installątion and commissioning of ISI marked Solar Modules as per following specification: 1. Cell: Indigenous mono crystalline silicon SPV cells 2. Solar Module: Monocrystalline cell with PERC technology / module with bifacial cell. 3. Standards: 1st marked as per IS 14286 and having certification of IEC 61853(1), 61730(1&2), 61710 4.ModuIes must qualify to lS 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill factor: More than 75% . 7. Module wattage mismatch in the SPV array: within -t3% 8. Wattage output warranty:ShouId not be less than 90% at the end of 10 years and 80'X at the end of 25 years.9.The power output of individual PV modules used in the PV array, under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For detail information please see CI. no. 2.1 of technical specification.(i) 150 mm. dia. G.I Pipe.
71Module Mounting Structure ( For 1 HP, 2HP, 3HP, 5HP and 10 HP Solar Water Pumping System):Supply , transportation & installation of G.I manual tracking / Fixed structure made of MS hollow sections, pipes, plates, angles etc as per IS: 4923, IS 1161/1239, IS: 1079/2062, to hold min 300 Wp SPV Module as per drawing and technical specification. The steel structure is to be protected with minimum 80 micron galvanisation (hot dip) and provided with fixed arrangement or dual axis manual tracking arrangement for three times in a day and seasonal tilting to face the sun optimally.(i) 150 mm. dia. G.I Pipe.
72Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per drawing.For 6 Module Mounting Structure
73For 4 Module Mounting Structure
74Power conditioning unit with enclosure :Supply , transport , installation and commissioning of Solar Power conditioning Unit consisting of following components and features:1)Variable frequency Drive with Inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned In cl.6.12)Power Input : DC source for 1HP, 2HP and 3HP.3)Power input : AC / DC source or hybrid for 5HP and above.4)Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.SHP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-25)Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for IS to 20 HP ar per IS/IEC 60947-16)Type II DC SPD of 40 KA.7)Type II AC SPD of 40 KA for AC/ DC or Hybrid Input.8)Dual Input (solar/Grid) 25 amp changeover switch for SHP and 7.5 HP, 40 amp for 10 HP, 63 amp for 1S to 20 HP9)Reverse protection diode 1600 VDC with heat sink.10)Data Logger.11)Remote menltoring system.12)Should have built -In EMC filters .13)IP 65 elands for cable In and out.14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to CI. 6.1 of technical qualification.Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I).g) For 5 HP capacity Pump-motor set with AC / DC or hybrid input
75Cable and Accessories :Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.i. 4.0 Sq mm single core multi studs - 5m (for 2 HP) & 26 m (for 3/5 HP)ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etcb) For 5 HP per structure
76Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick × 3.04 Mts. long and 1 × 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia × 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm × 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
77a) Lighting System at Scheme: (with lighting Pole) :Dusk to dawn lighting arrangement of at 4 mts height above ground level, with Hot dip galvanised 80 mm × 50 mm , medium duty pipe, with 12 V, 15Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 7-11watt LED lamp , 50 Wp solar panel to cover the scheme area. The lighting system should be warranted for 5years from the date of installation.
78b) Lightning protection (Pole mounted): Lightning protection with 3\\" × 1.5\\" G.I pipe of 6m + 1 m height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing)
79Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:-g) For 5 HP capacity Pump-motor set with AC / DC or hybrid input d) 5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:-i) Monoblock Surface Pump-motor set ISI marked as per IS: 9079 for mini RLI scheme with discharge of 13.8 Lps at 18 mts. total head with 100/80 mm dia. reinforced PVC suction pipe (20m) and delivery pipe(10mts), foot valve, nipple, priming bend Cable and all other required accessories to complete connection of suction and delivery side .
80Testing and commissioning of scheme after completion of all work
81b) Supply fitting and fixing of Hot dip Galvanised (min 80 micron) / Powder Coat painted / Galvanised M.S Kiosk Box of 800(L) × 500(W) × 650(H) and total height with legs is 950mm (above ground) including foundation(as per drawing) for mounting of motor-pump set including transportation, - For 5 HP surface pump.
82Cleaning and washing of modules once In month with clear water to remove deposited dust and dirt on the module surface and keep the modules clean throughout the year. The activity to be performed for eight months in a year excluding four monsoon months. A log book should be maintained at the site forthe said purpose.(5 yrs. × 8 months in each year) × (4 structure) = 160 months structure
83Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time)c) For 5 HP both for Submersible & Surface pumpNote:1 Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit. Comprehensive maintenance charges will be released @ i) Rs 0.80 for 2 HP, ii) Rs.0.80 for 3 HP, iii) Rs.0.60 for 5 HP & 10 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e.at the end of 1st year, 2nd year, 3rd year, 4th year& 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited
84Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic functions:a. Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials.b. Ltve status must indicate whether controller is ON/ OFF. The parameters i.e. the water output, water flow rate, in fault condition, array input voltage/ current, power and motor frequency should at logged at an interval of 10 minutesc. Controller must have a back up to store the data locally ( at least for 1 year) supply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the solar pumping system with time stamp at user-defined interval and report generation at the buyer end. (Refer Technical Spec.)
85Insurance @ 2% for Item No. 1, 4, 7, and 9 for a period of 5 years.Note:2Ist year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be with held which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment.
86Supplying, fitting and fixing including transportation of sign board for identifying the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding LS and writting of both sides of Sign board. Base - Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C. CPWD Item Sub - Total = WRI&Ddand I&WD Item Sub - Total =
87Modified Estimated cost after using correction factor on DSR 2023 on account of GST @ 0.973 as per Office Memorandum vide e file No. :9158977, File No.- 158/SE (TAS)/GST/2024/02-E, Dated - 08.08.2024 of the Superintending Engineer (TAS) of CPWD(CPWD Item Sub Total Amount- x 0.973)
88Cost indices of Paschim Medinipore as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is - {CPWD Item Sub Total Amount- x 0.973)x1.09} Add GST (Except item Foundation of Module Mounting Structure) @ 18% Labour welfare Cess (Except item Foundation of Module Mounting Structure) @1% Grand Total Rs. Say Rs
89PART – D [FORMATION OF WUA AT BELMA-I I New Solar Mini RLI Scheme UNDER MIDNAPORE (A-M) DIVISION.]
90Campaigning in the command area of Mini RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.
91Demarcation of command area, selection of beneficiaries and preparation of land schedule within the Command area of one Mini RLI having CCA 20 Ha.
92Meeting Cost for WUA formation, cost induding Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental changes.
93Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, œnveyance cost & opening of Bank A/C etc.
94Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to communlty worker, remuneration to resource person and incidental charge.(rate on meeting )
95Meeting and onsite demonstration for operation & maintenance of one Mini RLI, water manangement and mode of collection of water tax, building of corpus fund etc
96IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 & SL - 4
97Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.
98Impact study & monitoring of scheme by site visit of 2 Community workes during 3 years’ period Grand Total Rs. Say Rs

AI Tender Summary

OUR REF NO 58402881
AUTHORITY Government Departments
TENDER VALUE 26.99 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Water Resources Department
Work Description Tender for All In One Bid For Installation Of Belma-Ii New Solar Mini Rli Scheme Under Block- Keshiary Block In The District Of Paschim Medinipur Under The Executive Engineer (Am), Midnapore (Am) Division Under Core-Sector Program For The Financial Year 2026-27.
Basic Detail
Tender No WBWRDD/SE (AM)/Res Circle/eNIT-77/2026-27
Bidding Type Tender
Location
City Medinipur West
State West Bengal
Key Dates
Publish Date 05 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 26.99 Lakhs
Tender Fee Ref. Documents
EMD 53994
Exemption Available
Document List
425afdeb-6cdb-4142-9150-1cf58ddd7cc4.html
BOQ_5202745.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 30 days

Tender Documents

Download All (ZIP) ↓
html

425afdeb-6cdb-4142-9150-1cf58ddd7cc4.html

xls

BOQ_5202745.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender