Tender For Repair/Maintenance Of Lt Overhead Lines, Conversion Of Oh Lines To Ug Cables, Lt Protection Switch Gears Etc With Connected Works At 512 Abws And Cafvd Area Under Age E/M -Ii In Ge (Central) Khadki. (2Nd Call As On 05 Nov 2026)

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
40 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
4 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Lt Overhead Lines, Conversion Of Oh Lines To Ug Cables, Lt Protection Switch Gears Etc With Connected Works At 512 Abws And Cafvd Area Under Age E/M -Ii In Ge (Central) Khadki. (2Nd Call As On 05 Nov 2026)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 19-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-Nov-2026

BOQ

Name of Work:- REPAIR/MAINTENANCE OF LT OVERHEAD LINES, CONVERSION OF OH LINES TO UG CABLES, LT PROTECTION SWITCH GEARS ETC WITH CONNECTED WORKS AT 512 ABWS AND CAFVD AREA UNDER AGE E/M -II IN GE (CENTRAL) KHADKI. (2ND CALL AS ON 05 NOV 2026)
Sl. No. Item Description
1Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard / dense soil complete all as specified and directed.
2Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
3Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
4Material and labour for boring of holes of 140 mm dia under the road/hard standing with trench less technology boring method upto 2 mtr below the surface for laying cable line complete all as specified and directed. Note : All equipment & Machinery required to carry out the work will be provided by the contractor (If due to any obstruction during boring, reboring has to be done the same will be done by the contractor at his own cost the rates deem to cover the same.
5Material and labour for laying double wall corrugated (DWC) high density polythene pipes size 135 mm outer dia having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & 14930 (Part-I and II) for protection of underground cable with all fittings such as clamps, coupler etc. laid in trenches/roads/nallah or fixed along wall/ poles or laid under floor (including cutting floor/road and making to match with existing adjouning surface etc. for cable protection all as specified (excavatoin and earth work measured and paid separately)
6Description all as per item No. 05 above but of size 100mm OD
7Description all as per item No. 05 above but of size 75 mm OD
8Supply, laid in trench /fixed with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 300 Sqmm (earthed) complete all as specified and as directed.
9Supply, laid in trench /fixed with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 240 Sqmm (earthed) complete all as specified and as directed.
10Supply, laid in trench /fixed with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 150 Sqmm (earthed) complete including taking down unsv cable all as specified and as directed.
11Supply, laid in trench /fixed with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 120 Sqmm (earthed) complete including taking down unsv cable all as specified and as directed.
12Supply, laid in trench /fixed with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 95 Sqmm (earthed) complete including taking down unsv cable all as specified and as directed.
13Supply, laid in trench /fixed with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 70 Sqmm (earthed) complete including taking down unsv cable all as specified and as directed.
14Supply, install, testing and commissioning of LT panel indoor type IP54 complete as per latest IS of minimium size 150 cm x 100 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2.00 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 bus bar system 415 Volts, 50HZ for each switchgear double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including necessary earth work and PCC work, prewired complete duly powder coated with comprising of the following :-
15INCOMING :-(i) S&F ACB of rating 800A, 4 pole, 50 KA, manual draw out type, microprocessor based release, fully interlocked casette door, automatic saftey shutters, mechanical ON & OFF indiacators, closing coil and shunt trip coil voltage 220-250 V AC including self powered electronic protection umits MP4.10, electronic PU with LSI/LSIg + Neutral O/L + over temprature protection + LCD Display with current metering + 20 Trip History + 20 Alarm + Logical selectivity (iii) Phase indicating lamp LED type with MCB – 1 Set of three.(iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No.(vi) Aluminium bus bar 1200Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. (vii) CT Ratio 1000/5 - 03 Nos,class 1.0, 10 VA suitable for metering application.
16OUT GOING (i) MCCB 630 Amp ,415 Volt,50 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) , Confirms to IS/IEC60947-2 - 01 Nos (ii) MCCB 400 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) , Confirms to IS/IEC60947-2 - 02 Nos (iii) MCCB 200 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) , Confirms to IS/IEC60947-2 - 01 No (iv) MCCB 100 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) , Confirms to IS/IEC60947-2 - 02 Nos (v) MCCB 63 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) , Confirms to IS/IEC60947-2 - 02 Nos
17Supply, install, testing and commissioning of LT panel out door type of minimium size 150 cm x 100 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 bus bar system 415 Volts, 50HZ for each switchgear double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including earthwork, PCC work, prewired complete duly powder coated with comprising of the following :-
18INCOMING :-(i) MCCB 400 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms), Confirms to IS/IEC61439-1&2 - 02 Nos (ii) On load change over switch capacity 400 Amp, 4 pole, 415 V, , Size FR4, Type CO4-400, site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, with all fixing accessories suitable for horizontal as well as vertical mounting complete all as directed by Engr-in-Charge.(iii) Phase indicating lamp LED type with MCB – 1 Set of three.(iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No. (vi) Aluminium bus bar 630Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.
19OUT GOING (i) MCCB 320 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 Nos (ii) MCCB 200 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 Nos
20Supply, install, testing and commissioning of LT panel of minimium size 120 cm x 100 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 bus bar system 415 Volts, 50HZ for each switchgear double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
21INCOMING :-(i) On load change over switch capacity 400 Amp, 4 pole, 415 V, , Size FR4, Type CO4-400, site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, with all fixing accessories suitable for horizontal as well as vertical mounting complete all as directed by Engr-in-Charge.- 01 No(ii) MCCB 400 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No (iii) Phase indicating lamp LED type with MCB – 1 Set of three.(iv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(v) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (vi) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No. (vii) Aluminium bus bar 630Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.
22OUT GOING :-(i) MCCB 250 Amp , 415 Volt, 36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No (ii) MCCB 200 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 Nos (iii) MCCB 160 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 03 Nos (iv) MCCB 100 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No
23Supply, install, testing and commissioning of LT panel of minimium size 120 cm x 100 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 bus bar system 415 Volts, 50HZ for each switchgear double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
24INCOMING :-(i) On load change over switch capacity 630 Amp, 4 pole, 415 V, , Size FR4, Type CO4-400, site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, with all fixing accessories suitable for horizontal as well as vertical mounting complete all as directed by Engr-in-Charge.- 01 No(ii) MCCB 630 Amp ,415 Volt,50 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No (iii) Phase indicating lamp LED type with MCB – 1 Set of three.(iv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(v) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (vi) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No.(vii) Aluminium bus bar 630Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.
25OUT GOING :-(i) MCCB 400 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No (ii) MCCB 200 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 Nos (iii) MCCB 160 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 Nos (iv) MCCB 100 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 Nos
26Supply, install, testing and commissioning of LT panel of minimium size 120 cm x 100 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 bus bar system 415 Volts, 50HZ for each switchgear double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
27INCOMING :-(i) On load change over switch capacity 400 Amp, 4 pole, 415 V, , Size FR4, Type CO4-400, site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, with all fixing accessories suitable for horizontal as well as vertical mounting complete all as directed by Engr-in-Charge.- 01 No(ii) MCCB 400 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No (iii) Phase indicating lamp LED type with MCB – 1 Set of three.(iv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(v) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (vi) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No..(vii) Aluminium bus bar 630Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.
28OUTGOING :-(i) MCCB 200 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 Nos (ii) MCCB 160 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 Nos (iii) MCCB 100 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 No (iv) MCCB 63 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No
29Supply, install, testing and commissioning of LT panel of minimium size 100 cm x 100 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 bus bar system 415 Volts, 50HZ for each switchgear double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
30INCOMING :-(ii) MCCB 250 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No (iii) Phase indicating lamp LED type with MCB – 1 Set of three.(iv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(v) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (vi) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No.(vii) Aluminium bus bar 630Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.
31OUTGOING :-(i) MCCB 160 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 03 Nos (ii) MCCB 100 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 02 No (iv) MCCB 63 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 - 01 No (v) Timelite distribution board of capacity 40 Amp, 3 pole, 230 Volts (Analog Time switch), Contractor cap 40 Amp, 3 phase including time time switch, Degree of protection IP 54, Aesthetically appealing with locking facility, switch ON and Switch Off for Air conditioner on time scheduling basis incorporating a analog switch and contractor, protect from over load/ Short circuit - 01 No
32Material and labour for Chemical Earthing complete with copper bonded 17.2 mm earthing rod outer dia electrode, including testing 3 mtr long and having suitable hole on top to connect earthing strip with copper nut bolts and washers, placed in ground in a bore 3.5 mtr drilled by Pneumatic boring machine and pouring slurry in bore of 50 Kg BFC compound having high moistue retaining capacity, earth pit cover made of reinforced FRP complete all as specified and as directed. NOTE :- (a) Contractor should visit site before quoting the rates. (b) Rates including demolition of old earthing. (c) Contrctor should provide all necessary safety measures during exectution the job and responsible for any loss to the Govt property during execution the job.
33Material and labour replacement of galvanised iron (GI) strip 32 X 6 mm,with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
34Supply and fixing galvainesd water tubing light grade 50 mm dia of bore with fix with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as specified and as directed.
35Supply and fixing in replacement fire retardant / extinguishing electric insulated synthetic mat insulatica-2000 of 3.0 mm thick +10% confirming to BIS : DOC No ET-02 (5440) dated 30 Apr 2004, meeting requirement of IS-3043, IS-5216 (Part I, II, III) IS-8437 and IEC 479 pub I, tested for breakdown strength, tensile/Elongation ageing properties, insulation resistance, effect of acid, alkaline, diesel and transformer opil leakage current test, fire test etc. having minimum width of 1000 mm + 20 mm including all allied materials such as PU-resing, chemical bound (Haedener) special PVC adhesive liquid primer etc of required quantity to complete the job as per site requirement
36Material and labour for attending complaint of external electric supply system under AOR of AGE E/M-II, finding fault in underground cable and rectify the fault and provide fault finding machine for defect rectification underground cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. all as directed. NOTE :- (i) The fault locating equipments will be brought to site within the 04 hours of instruction from Engr-in-Charge.(ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and has to be rectified within 12 hours after notification, failing which Rs 500/- per day per complaint will be recovered from the dues to the contractor.(iii) Rates included necessary earth work for opening cable.
37Supplying, fixing, jointing and testing heat shrinkable Straight through joint , with including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size 400 sqmm , 3.5 core , all as specified and as directed.
38Supplying, fixing, jointing and testing heat shrinkable Straight through joint , with including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size 185 to 300 sqmm , 3.5 core , all as specified and as directed.
39Supplying, fixing, jointing and testing heat shrinkable Straight through joint , with including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size 70 to 150 sqmm , 3.5 core , all as specified and as directed.
40Dismantling of ACSR Conductor complete all as specified and as directed.
41Dismantling of old unsv Insulator any type and any size
42Dismantling cross-arms of M.S. channel or angle sections etc complete and setting aside for re-use with in 50m
43Taking down old unsv MCCB & Supply and fix MCCB 400 Amp ,415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 complete all as specified and as directed.
44Taking down old unsv MCCB & Supply and fix MCCB 250 Amp , 415 Volt,36 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 complete all as specified and as directed.
45Taking down old unsv MCCB & Supply and fix MCCB 200 Amp ,415 Volt,25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 complete all as specified and as directed.
46Taking down old unsv MCCB & Supply and fix MCCB 160 Amp , 415 Volt, 25 KA, 4 pole with thermal magnetic protection unit, Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) Confirms to IS/IEC60947-2 complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58399093
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Lt Overhead Lines, Conversion Of Oh Lines To Ug Cables, Lt Protection Switch Gears Etc With Connected Works At 512 Abws And Cafvd Area Under Age E/M -Ii In Ge (Central) Khadki. (2Nd Call As On 05 Nov 2026)
Basic Detail
Tender No 8434/E8 OF 2026-2027
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 19 Nov 2026
Submission Date 26 Nov 2026
Open Date 28 Nov 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
8434Tender2NDCALL.pdf
BOQ_894503.xls
fcb80b99-e53a-4000-811d-74f1e908002d.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

8434Tender2NDCALL.pdf

xls

BOQ_894503.xls

html

fcb80b99-e53a-4000-811d-74f1e908002d.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender