Tender For Repair/Replacement And Overhauling Of Water Cooled Conetral Ac Plants, Dx Type Central Ac Plant, Rewinding Of Compressor Motors, Replacement Of Values And Other Connected Misc E/M Works At Bhdc Under Ge (East) Delhi Cantt-10
Tender Overview
Project Description
Tender for Repair/Replacement And Overhauling Of Water Cooled Conetral Ac Plants, Dx Type Central Ac Plant, Rewinding Of Compressor Motors, Replacement Of Values And Other Connected Misc E/M Works At Bhdc Under Ge (East) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Annual maintenance contract for Air Conditioning plant and other equipment for the following :-Centrifugal pumps of cap 10 HP - 06Centrifugal pumps of cap 15 HP - 06Screw chiller of cap 75 TR - 06Note 1 :(i) Checking the functioning of Chiller unit/Air Handling unit/Pumps/Cooling tower/Controls and all such equipmentcovered under the contract.(ii) Free replacing of defective/worn-out parts with new or repaired parts for compressor/thermostat/cut outs based onour assessment.(iii) Repairing of equipment as listed in the equipment list at site/service station as the case may be. (iv) Descaling of condensers/chemical cleaning of evaporator coils/replacement of pre-filters based on our assessmentand working parameters of the plant.(v) Replenishing refrigerant gas and compressor oil in the system arising out of system defect, excluding sealedcompressor.(vi) Checking of compressor for its proper working.(vii) Annual pumping-down and restarting as and when required.(viii) Checking of Microprocessor control panel, control boards, transducers of packaged chillers/condensing unit for theircorrectness and replace if necessary.(ix) Replacing of parts due to normal wear and tear. |
| 2 | Note 2 :(i) Four preventive Maintenance calls shall be provided during the contract period of one year. They shall be as per dates and time provided by customer during normal working hours (Monday to saturday between 9:00 AM to 7:00 PM) on any working day. Washing the condenser coil with water to remove the dust accumulated inside the coil.(ii) Cheking the refrigerant pipe joint with solution for any leakage in the system and ensuring that the entire piping is made fully functional.(iii) Checking & Tightening all bolts & nuts. (iv) Cheking & making fully functional all electric connections of control panel. (v) Cheking & making fully functional all electric connections of compressor & condenser fan motors.(vi) Cheking the suction/ discharge pressure of compressor to study any abnormal running condition & rectifying the same if noticed.(vii) Checking voltage & current to study / detect any abnormal running conditions and assist in rectifying the same if noticed with in our set free unit. BLUE STAR, on its own, would carry out rectification steps in the equipment if needed, otherwise advice customer to take corrective action at their end.(viii) Checking voltage imbalance between phases and pointing out any problem to customer for corrections, provided any correction required in the equipment would be corrected out by BLUE STAR.(ix) Cheking of unloading solenoid valves and ensuring smooth functioning of the same. Please Enable Macros to View BoQ information |
| 3 | Note 2 :(i) Four preventive Maintenance calls shall be provided during the contract period of one year. They shall be as per dates and time provided by customer during normal working hours (Monday to saturday between 9:00 AM to 7:00 PM) on any working day. Washing the condenser coil with water to remove the dust accumulated inside the coil.(ii) Cheking the refrigerant pipe joint with solution for any leakage in the system and ensuring that the entire piping is made fully functional.(iii) Checking & Tightening all bolts & nuts. (iv) Cheking & making fully functional all electric connections of control panel. (v) Cheking & making fully functional all electric connections of compressor & condenser fan motors.(vi) Cheking the suction/ discharge pressure of compressor to study any abnormal running condition & rectifying the same if noticed.(vii) Checking voltage & current to study / detect any abnormal running conditions and assist in rectifying the same if noticed with in our set free unit. BLUE STAR, on its own, would carry out rectification steps in the equipment if needed, otherwise advice customer to take corrective action at their end.(viii) Checking voltage imbalance between phases and pointing out any problem to customer for corrections, provided any correction required in the equipment would be corrected out by BLUE STAR.(ix) Cheking of unloading solenoid valves and ensuring smooth functioning of the same. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender