Tender For Repair/ Replacement Of Lt Panels & Switch Gears & Connected Items At Dmrl And Atc Devatalagutta Under Ge (I) R&D Kanchanbagh, Hyderabad.
Tender Overview
Project Description
Tender for Repair/ Replacement Of Lt Panels & Switch Gears & Connected Items At Dmrl And Atc Devatalagutta Under Ge (I) R&D Kanchanbagh, Hyderabad.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Nov-2026 | Amendment | BOQ | 28-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply , install test & commission of LT Panel in door type, Cubicle type, as per IS/IEC-61439- for 415 V ,50Hz,rated fault current : 75KA with internal arc containment dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing aluminium bus bar of capacity 1000 Amps rating including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferrules. The panel shall be painted with anticorrosive coating and finally epoxy polyester powder coating of siemens grey shade (RAL -7032). the panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering (Where necessary) complete all as specified and directed by Engr-in-Charge.IncomingMCCB 630 Amp 36 KA - 01 Nos (Incoming)cosOutgoing MCCB 4 Pole 200 Amps 36 KA-02 NosMCCB 4 Pole 100 Amps 36 KA-02 NosMCCB 4 Pole 63 Amps 27 KA-04 NosMCB 4 Pole 32 Amps 27 KA-04 Nos |
| 2 | Supply , install test & commission of LT Panel in door type, Cubicle type, as per IS/IEC-61439- for 415 V ,50Hz,rated fault current : 75KA with internal arc containment dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing aluminium bus bar of capacity 1000 Amps rating including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferrules. The panel shall be painted with anticorrosive coating and finally epoxy polyester powder coating of siemens grey shade (RAL -7032). the panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering (Where necessary) complete all as specified and directed by Engr-in-Charge(PEG WORKS SECTION)IncomingMCCB 4 Pole 630 Amps 36 KA -01 No'sOutgoingMCCB 4 Pole 400 Amps 36 KA-02 NosMCCB 4 Pole 200 Amps 36 KA-02 NosMCCB 4 Pole 100 Amps 36 KA-03 NosMCB 4 Pole 63 Amps 36 KA-03 Nos |
| 3 | Supply , install test & commission of LT Panel in door type, Cubicle type, as per IS/IEC-61439- for 415 V ,50Hz,rated fault current : 75KA with internal arc containment dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing aluminium bus bar of capacity 600 Amps rating including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferrules. The panel shall be painted with anticorrosive coating and finally epoxy polyester powder coating of siemens grey shade (RAL -7032). the panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering (Where necessary) complete all as specified and directed by Engr-in-Charge(MRS)IncomingMCCB 4 Pole 630 Amps 36 KA-01 NosOutgoing MCCB 4 Pole 200 Amps 36 KA-02 NosMCCB 4 Pole 100 Amps 36 KA-02 NosMCCB 4 Pole 63 Amps 36 KA-02 NosMCB 4 Pole 32 Amps 36 KA-03 Nos |
| 4 | M & L for Earthing with G I earth plate 600 mm X 600 mm X 6 mm thick including accessories, an providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 5 | S&F Laying LT UG cable heavy duty armoured with aluminum conductor multistranded PVC insulated and sheathed with suitable lugs including taking out old unserviceable cable complete all as directed for following sizes: -2 core 10 Sqmm |
| 6 | 4core 16 Sqmm |
| 7 | 3.5 core 25 Sqmm. |
| 8 | 3.5 core 35 Sqmm. |
| 9 | 3.5 core 50 Sqmm. |
| 10 | 3.5 core 95 Sqmm. |
| 11 | 3.5 core 120 Sqmm. |
| 12 | 3.5 core 185 Sqmm. |
| 13 | 3.5 core 240 Sqmm. |
| 14 | 3.5 core 300 Sqmm. |
| 15 | 3.5 core 400 Sqmm. |
| 16 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as directed. |
| 17 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick using soil complete all as directed. |
| 18 | Removing excavated material to a distance exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as directed. |
| 19 | Supply and spreading natural dry, clean river sand in trenches for cushioning of cable complete all as directed. |
| 20 | M&L for brick protection with common burnt bricks sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed. |
| 21 | Supply and fixing four pole, 415 V MCCB 200Amp 36 KA capacity complete with connections, testing and commissioning all as specified |
| 22 | All as per serial item no .15 but MCCB of 250 Amps |
| 23 | All as per serial item no .15 but MCCB of 400Amps |
| 24 | Supplying and fixing consider for the equipement surface/ recess mounted for 200 Amps MCCB complete with connections, testing and commissioning specified |
| 25 | All as per serial item no .18 but MCCB of 250 Amps |
| 26 | All as per serial item no .18 but MCCB of 400Amps Please Enable Macros to View BoQ information |
| 27 | All as per serial item no .18 but MCCB of 400Amps Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender