Defence Statutory Bodies & Commissions/Committees Closing in 22 days TDR #58399071

Tender For Repair And Maintenance And Replacement Of Flame Proof Lights, Steel Conduiting Ug Cable, Internal Wiring, Fittings And Fixtures , Earthing La System And Gantries Of Wsa Area At Af Station Suratgarh

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
40 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
22 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance And Replacement Of Flame Proof Lights, Steel Conduiting Ug Cable, Internal Wiring, Fittings And Fixtures , Earthing La System And Gantries Of Wsa Area At Af Station Suratgarh

BOQ

Name of Work:- REPAIR AND MAINT AND REPLACEMENT OF FLAME PROOF LIGHTS, STEEL CONDUITING UG CABLE, INTERNAL WIRING, FITTINGS AND FIXTURES , EARTHING LA SYSTEM AND GANTRIES OF WSA AREA AT AF STATION SURATGARH
Sl. No. Item Description
1BOQ (REPAIR AND MAINT AND REPLACEMENT OF FLAME PROOF LIGHTS, STEEL CONDUITING UG CABLE, INTERNAL WIRING, FITTINGS AND FIXTURES , EARTHING LA SYSTEM AND GANTRIES OF WSA AREA AT AF STATION SURATGARH)
2Taking down DB/sheet enclosure/metal plug socket/main switch of any size and making good disturbed surface of wall/floor complete all as specified.
3Taking down U/S submain wiring aluminium etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface.
4Taking down carefully aluminum point wiring (light, fans, socket etc) complete and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
5Taking down carefully switch, socket Regulator, ceiling rose, angular holder /LED lamps/LED lights/ PVC Bd complete and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
6M & L for point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including steel conduit of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for flame proof light point or one fan point controlled by one, one way switch and making good to disturbed surfaces all as specified and directed.
7All as per item No 5 here-in-before but 5 amps socket point independent all as specified and directed.
8All as per item No 5 here-in-before but 5 amps socket point on same board as specified and directed.
9All as per item No 5 here-in-before but cable of size 2.5 sqmm for one 16 amps socket (Power) point independent all as specified and directed.
10M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4 sqmm (Nominal area) drawn through in and including steel conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of steel conduit will be measured as one length.
11All as per item No 9 here-in-before but cable of size 6.0 sqmm all as specified and directed.
12S&F 5 Amp switch piano type single pole one way one all as specified and as directed.
13S&F socket flush type 6 amps, 5 pin, 230v all as specified and as directed.
14S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v one all as specified and as directed.
15S&F ceiling rose surface Bakelite three terminal all as specified and as directed.
16S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz all as specified and as directed.
17S&F Switch flame proof rotary type with termination chamber in LM6, 16A, single pole 250V complete all as specified and as directed.
18S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth
19S&F Metal plug and socket board with MCB SP 20 amp, 16 KA all as specified and directed.
20S&F flame proof any weather proof MCB distribution board, 230 Volts, 8 way all as specified and directed.
21S&F MCB, Single Pole, 6 to 32 amps, 240 volts, 10 kA breaking capacity, \\"C\\" curve all as specified and as directed.
22S&F MCB, Double Pole, 6 to 32 amps, 415 volts, 10 kA breaking capacity, \\"C\\" curve all as specified and as directed.
23S&F MCB, Four Pole, 40 to 63 amps, 415 Volts all as specified and directed.
24S&F MCB distribution board, Double door, metal enclosure , SPN, 230 Volts,8 way all as specified and as directed.
25S&F LED fitting, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable all as specified and directed.
26S&F LED tube rod polycarbonate 20 watt retrofit PF 0.9 suitabe for 4 feet flame batten , complete wiring with 0.5 sqmm copper flexible conductor, connecting up to ceiling rose including taking down all as specified and directed.
27S&F as in replacement recess mounting back lit LED 36 watt 2x2 with color temperature 6500 k and efficacy not less than 100 lumens per watt in CRCA housing with full opal difference suitable for grid ceiling with revolutionary flicker controlled technology. complete all as specified and directed.
28S&F flame proof batten suitable for single tube rod (1x20 W) Power factor >0.95 and efficacy >100 lumens/watt CMRI certified recommended for gas/vapour group of IIA & IIB, Zone 1&2 and IP 66 Protection with die cast aluminium housing with heat resistant toughened glass with all accessories prewired and including connecting upto ceiling rose incl taking down old unsv fitting complete all as specified and directed by Engr-in-Charge.
29As per item No 29 but flame proof batten suitable for 2X20 watt tube rod all as specified.
30S&F flame proof LED light fitting 40 watt CMRI certified and recommended for Gas Group IIC, Zone 1 and 2. Temperature Class T6 IP 65 Protection with die cast aluminium housing with heat resistant toughened glass with ll accessories prewired incl taking down old unsv fitting complete all as specified and directed by Engr-in-Charge.
31S&F flame proof LED light fitting 120 watt CMRI certified and recommended for Gas Group IIC, Zone 1 and 2. Temperature Class T6 IP 66 Protection with die cast aluminium housing with heat resistant toughened glass with all accessories prewired incl taking down old unsv fitting complete all as specified and directed by Engr-in-Charge.
32Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in soft loose soil complete all as specified and as directed.
33Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
34Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
35M&L for road cutting upto 300 mm deep and 300 mm wide /bore hole under road for crossing cable through GI pipe under road including making good the disturbed surface by filling mass concrete complete all as specified and directed by Engr-in-Charge.Note: Mass concrete will be measured and paid as saperate item.
36PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
37PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
38Material and labour for river washed and screened, dry sand for filling in trenches 8 cm below cable and 15 cm above cable and punned down gently to achieve 10 cm thickness of top layer for cushioning of cables etc, complete all as specified.Note: for payment purpose thickness after punning 18 cm will be measured and paid
39M&L for sub class 'B' brick for protection of UG cable including taking down broken bricks complete all as specified and directed by Engr-in-Charge
40Dismantling / taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit complete all as specified and directed.
41Supply & laying of LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 16 Sqmm 2 core as per IS 7098 (Part-I) laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. (Note: (i) Cable joint shall be measured and paid separately.)
42All as per item No. 42 here-in-before but 10sqmm 4 core complete all as specified
43All as per item No. 42 here-in-before but 16sqmm 4 core complete all as specified
44All as per item No. 42 here-in-before but 25sqmm 3.5 core complete all as specified
45All as per item No. 42 here-in-before but 35sqmm 3.5 core complete all as specified
46All as per item No. 42 here-in-before but 50sqmm 3.5 core complete all as specified
47All as per item No. 42 here-in-before but 70sqmm 3.5 core complete all as specified
48All as per item No.42 here-in-before but 95sqmm 3.5 core complete all as specified
49All as per item No. 42 here-in-before but 120sqmm 3.5 core complete all as specified
50Labour only for relaying or fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 25 sqmm 4 core obtained from item no 52 here-in-before with required aluminium cable lugs, heat shrink joints at cable ends all as specified and directed.
51Labour only for relaying or fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size 35 sqmm to 95 sqmm 3.5 core obtained from item no52 here-in-before with required aluminium cable lugs, heat shrink joints at cable ends all as specified and directed.
52Painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge
53Supply and fix Heat shrink straight through joint LT 1100 volts grade 10 -16 sqmm, 2 core,
54Supply and fix Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core
55Supply and fix Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core
56Supply and fix Heat shrink straight through joint LT 1100 volts grade 70-150 sqmm, 4 core
57Supply and fix GI tubing light grade 40mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road crossing ISI marked, for cable protection incl dismentling taking down unserviceable one all as specified and directed
58Supply and fix GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road crossing ISI marked, for cable protection, ISI marked for cable protection incl dismentling taking down unserviceable one all as specified and directed
59M & L for three core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through PVC Conduit and OH line/ street light to pole box incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed.
60Servicing/cleaning to air curtain and repair/replacement of defective parts and reassemble air curtain and testing complete all as specified and directed by Engr-in-Charge (Note : Minor part including Labour required for the replacement of unserviceable items shall be deemed to be included in the unit rate quoted against this item)
61Supply and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 2.5 sqmm and overall PVC sheathed in service connections from OH conductor to building/street light to pole box incl dismentling taking down unserviceable one all as specified and directed. Make -Finolex, Anchor and Plaza
62S & F as in replacement street light pole box (SMC) of size 25x25x15 cm with side hinged door and locking arrangement type suitable for fixing on LT pole and suitable for terminal single phase including MCB 6-10A SP and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cable in box. Complete all as specified and directed.
63Supply & fix of LED 70W street light, aesthetically designed roadway luminiare with excellent thermal management, pressure die-cast aluminium alloy for housing (heat sink) with epoxy powder coated with high efficiency long life LED chip inbuilt with electronic driver with APFC and including taking down old U/S street light fitting from bracket of any type and from any position
64S & F LED security/bldg light 45 watt, 230V with lens complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25mm dia bracket of total length 50 to 80 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
65S&F surface mounting time switches, daily dial, incl dismantling taking down unsv one.
66S&F 3 pole power contactor, 415Volts, 40 amps, incl dismantling taking down unsv one
67Labour for disconnecting LT cable of any size from DBs/Panel/pole/transformer for finding fault , M&L for defect rectification. LT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0900 to 1700 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs. 500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge. joint kit will be measured seperately in appropriate item in this schedule
68Labour only for disconnecting LT cable of any size from pole (height 7.5 to 9 mtr) /transformerpanle and re-connecting of cable at both end after removing carbon /burnt insulation part of cable by cutting refixing cable with new cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0900 to 1700 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs500/- per day complaint will be recoverd.
69Refixing/repair/ tightening of GI/Copper strip with cleat, air termanation rod and pipe with nut & bolt of lightning protection of building (area of building/igloo type 50x50 sqmm Approx) complete all as specified and directed by Engr-in-Charge . Note : (i) Area (50x50 sqmm) of building will be considered as one Job (ii) Porcelain cleat with nut, bolts are inclusive in labour qouted rate.
70Supply & fix in replacement of single pointed air termination aluminium rod 12mm dia, 300 mm long fixing on GI pipe 40mm/50mm with nut bolt or as per site requirement .
71Supply and Fix in replacementTTest point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specifie and directed.
72S&F as in replacement earth continuity conductor or main earthing lead of size 32x6 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc all as directed.
73S&F as in replacement earth continuity conductor or main earthing lead of size 20x3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc all as directed.
74M&L as in replacement earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etcall as directed.
75M&L as in replacement earth continuity conductor or main earthing lead of size 25x4mm aluminum strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc all as directed.
76Supply and fix in replacement of porcelain cleat with the help of nut,bolts clamps etc to fix the strips of various size and types to separate from ground and wall as directed at site by Engr in charge all as specified & directed.
77Supply and fix in replacement of PCC block 30mmx30mmx30mm to fix air termaination GI pipe of size 40mm/50 mm including demoliton of existing PCC block , removing of demoliton material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.all as specified & directed by Engr in charge.
78M&L for jointing of broken copper Strip by using suitable with brass nut & bolt arrangements and straightening complete all as specified and directed by Engineer-in-Charge.
79M&L for jointing of broken GI strip/aluminum strip by using suitable nut & bolt arrangements and straightening complete all as specified and directed by Engineer-in-Charge.
80Material and labour for Chemical Earthing complete as per IS:3043 including supplying and installing Copper Earthing Electrode consisting of Outer Pipe 65mm Dia x 3.0 Mtr Long and Inner Pipe 40mm Dia x 3.0 Mtr Long, both made of 99% Electrolytic Grade Copper, thickness 2.1mm, filled with 25 Kg Hydroscopic Conductive Chemical Jelly / Backfill Compound, buried vertically in ground, including 32x6mm Copper Strip from electrode to Test Point by brazing with Brass Bolts, Nuts, Washers, including PCC Earth Pit with RCC Cover, MS Frame, 40mm Dia GI Pipe upto 7.5 Mtr, including testing to achieve Earth Resistance less than 1 Ohm, complete all as specified and directed.
81Material and Labour for Earthing complete as per IS:3043 and Plate No-2 of SSR Part-I, including making bore hole of 150mm Dia x 8.0 Mtr deep by mechanical drilling rig, supplying and burying vertically 80mm Dia x 6.0 Mtr Long GI Pipe Electrode, Medium Grade, ISI Marked, with top edge at Ground Level, filled around with 50 Kg Bentonite based Chemical Compound, including 32x6mm GI Earthing Lead from electrode to Test Point, protected in 32mm Dia GI Tubing, including PCC Earth Pit 1:3:6 Type C-2 with RCC Cover, Funnel and Wire Mesh, including returning filling, removal of surplus soil and testing to achieve Earth Resistance less than 5 Ohms, complete all as specified and directed.
82Labour only for deployment of skilled labour for attending complaints of electric overhead traveling crane and identify faults using suitable Tools and Plants (T&P) and rectify the fault immediately as specified and directed by the Engineer-in-Charge. Complaint will be notified to the contractor via mobile phone between 08:00 and 18:00 hours. Minor rectifications will be done within 24 hours or Major rectification within 72 hours of notification. A penalty of Rs.500/- per day per complaint will be recovered for any delays beyond the specified timelines. Note : Minor spare parts are included in same job.
83Material and Labour for disconnecting the electric motor from the cranes transporting to workshop, taking out old winding and rewinding the motor with same gauge of copper wire varnishing, overhauling complete re-fitting to crane connecting and testing of following motor.
84Capacity 01 HP/02 HP Motor
85Capacity upto 3 HP Motor
86Supply and installation of red PVC sleeves, including the insertion of existing/new 20 mm x 3.15 mm copper strip inside the sleeves, either buried in the ground or fixed to the wall, to protect the strip from corrosion, moisture, and mechanical soil damage complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information
87Supply and installation of red PVC sleeves, including the insertion of existing/new 20 mm x 3.15 mm copper strip inside the sleeves, either buried in the ground or fixed to the wall, to protect the strip from corrosion, moisture, and mechanical soil damage complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58399071
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 02-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance And Replacement Of Flame Proof Lights, Steel Conduiting Ug Cable, Internal Wiring, Fittings And Fixtures , Earthing La System And Gantries Of Wsa Area At Af Station Suratgarh
Basic Detail
Tender No 8365/E8
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 05 Nov 2026
Submission Date 02 Dec 2026
Open Date 04 Dec 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
9fe1abf4-315f-4ae1-bfab-07d1c916b512.html
BOQ_894616.xls
Tenderdocuments8365.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

9fe1abf4-315f-4ae1-bfab-07d1c916b512.html

xls

BOQ_894616.xls

pdf

Tenderdocuments8365.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender