Tender For Repair/ Replacement Of Flame Proof Light Fittings, Highbay Light, Building Light, Signboards And Its Connected Items At Dmrl, Rcma, Atc Devatalagutta Under Ge (I) R & D Kanchanbagh, Hyderabad.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
5 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Flame Proof Light Fittings, Highbay Light, Building Light, Signboards And Its Connected Items At Dmrl, Rcma, Atc Devatalagutta Under Ge (I) R & D Kanchanbagh, Hyderabad.
BOQ
| Sl. No. | Item Description |
| 1 | S&F in repairs LED 120 watt highbay light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. |
| 2 | S&F in repairs LED 150 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. |
| 3 | S&F in repairs LED 100 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. |
| 4 | S&F in repairs LED 200 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. |
| 5 | Supplying, installation, Testing & Commissioning of Street light 35 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Please Enable Macros to View BoQ information |
| 6 | Supplying, installation, Testing & Commissioning of Street light 35 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender