Tender for Misc Repair To Security Wall, Gate, Fencing, Path, Hardstanding Etc To Various Labs At Kwc Under Ge (I) R&D Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for work including doors, gates, angle post etc. complete all as specified and directed by Engineer-in-Charge. |
| 2 | S&F Framed work as in Mild Steel Gate of angle or other section with gusset plate, rails, braces, stair case, barralled iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cover grills and similar work etc Fe. 290. Grade-E-165 complete drilled for fixing of steel sheeting or other covering including welding work , (PCC 1:1.5:3) etc to be prepared for hanging or sliding with and including either hooks, hinges, necessary holdfasts or steel hanging door fittings, locking arrangement, gate closer, stopper etc and hanging also fastening and fixing in building upto 8m height complete all as specified and directed by Engineer-in-charge. |
| 3 | S&F mild steel work as in joist channels, angle or tee section, fixed independently w/o connecting plate conforming to Fe.290. Grade-E-165, including cutting tops to shape as directed, drilling holes, notching for wire, welding work etc. flat iron fillets including all necessary drilling, bolting or riveting, etc., drilled and countersunk for balusters running bars, nosing to steps incl embeding in concrete and screwing etc. wind ties for roof including securing bolts;, and similar work including necessary cutting, drilling, welding etc. complete all as specified and directed by Engineer-in-Charge. |
| 4 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24 mm diameter barbed with 2mm diameter barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed by Engineer-in-Charge. |
| 5 | Restraining and resecuring Galvanised. 2 strand, steel barbed wire 2.24 mm diameter barbed with 2mm diameter barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed by Engineer-in-Charge |
| 6 | S&F in repairs of concertina coil fencing with punched tape, 600 mm diameter, having 50 Nos rounds per 6m length, laid on ground or fixing the same on Y-shaped angle iron with necessary G.I staples / GI clips to retain in horizontal position including necessary bolts, fasteners and binding wire complete all as specified and directed. |
| 7 | S&F in repairs of concertina coil fencing with punched tape, 450 mm diameter, having 50 Nos rounds per 6m length, laid on ground or fixing the same on Y-shaped angle iron with necessary G.I staples / GI clips to retain in horizontal position including necessary bolts, fasteners and binding wire complete all as specified and directed. |
| 8 | Excavation in post holes (or similar holes) in soft/loose soil not exceeding 0.50 Cum, getting out broken rubble and removing surplus soil/ malba outside MoD land all as specified. |
| 9 | M&L cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregates) as in foundation filling, mass concrete and sub floors etc. complete all as specified. |
| 10 | Dismantling timber scantlings 40 Sq. cm and over in framed work section, in any position complete as specified. |
| 11 | Dismantling timber scantlings under 40 Sq. cm in fillets, rails, posts, rafters,purlins, etc.in framed work section, in any position complete as specified. |
| 12 | S &F structural steel work in tubular trusses, posts, purlins, rafters, framed work in truss etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 complete all as specified. |
| 13 | M&L mild steel work for flat iron fillets as in wind ties for roof coverings including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Grade E-165 complete all as specified. |
| 14 | Dismantling of Asbestos cement (corrugated semi-corrugated etc) sheets in roof covering complete all as specified . |
| 15 | Supply and fixing Pre- painted galvalume Aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering, cladding to wall, ridges etc. fixed all as per manufacturer's instructions and fixed with self thread making steel screws of length not less than 50mm complete all as specified and directed by Engineer-in-charge. |
| 16 | Supply and fixing Pre-painted galvalume Aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/ cladding to wall, ridges, flashing, eaves board valley gutter of any shape etc, cut to designed shape (Jhhallar) as directed at site fixed all as per manufacturer's instructions and fixed with self thread making steel screws of length not less than 50mm complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of Synthetic Enamel paint over a coat of Red Oxide Primer, fixed complete all as specified and directed. |
| 18 | Demolition of plain cement concrete in ground floor and paving not exceeding 15 cm thick below or above ground level complete all as specified and directed. |
| 19 | M&L 100 mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregates) as in sub floors, filling and mass concrete etc complete all as specified. |
| 20 | M&L for machine made Rubber moulded precast concrete interlocking paver block (coloured),pre polished of any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-30 Grade, over and including 25mm average thickness sand cushioning complete all as specified and directed. |
| 21 | S&F factory made chequered cement concrete coloured tiles (250mm x 250mm/ 300mmx300mm) x 20 to 22 mm thick, set jointed and pointed in neat cement slurry with grey cement mixed with pigment to match the colour of tiles, laid over and including 20mm thick screed bed in CM (1:4), complete all as specified and directed. |
| 22 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons laid dry in any mortar complete all as specified and directed. |
| 23 | M&L machine cut Kota Stone slab as in flooring / landing of stairs, 18-20mm thick laid over and including 15mm thick cement screed bed in CM (1:4), laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab and including rubbing and polishing complete all as specified |
| 24 | M&L for cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth courses, copings, parapets, saucers drain, kneelers, apex stones, bed blocks, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 25 | Providing and laying at or near ground level factory made Kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3), (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as sepecified and directed. |
| 26 | M&L preparing new concrete surfaces over 10 cm width or girth and applying two coats of synthetic Enamel paint over a coat of Primer complete all as sepecified and directed. |
| 27 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc complete all as sepecified and directed. |
| 28 | M&L for brick work straight or curved on plan exceeding 6m mean radius in CM (1:4) with Sub class ‘B’ brick including manhole raising, footpath, etc complete all specified and directed by Engineer-in-Charge. |
| 29 | Taking down cement plaster, pointing, on brick or stone/concrete walls, drain surfaces etc including racking out joints, hacking for key, scrubbing down with water etc in any position complete all as specified and directed. |
| 30 | M&L for 15 mm thick Rendering on brick work or concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L for 15 mm thick Rendering on brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 32 | M&L preparation of newly plastered surfaces of walls and applying two Coats of Oil Emulsion Distemper of approved shade/tint over and including a coat of Birla White wall care putty (applying additional coats wherever required, to achieve smooth surface) complete all as specified and directed. |
| 33 | M&L for preparation of newly plastered or unplastered wall surfaces and applying two coats of Acrylic Emulsion Exterior quality over and including a coat of water based primer (Apex painting) (tint and pattern as approved by GE) complete all as specified. |
| 34 | M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls including pilasters and cornices etc. including washing, rubbing down and stopping the previously treated surfaces and applying two or more coats of 100% Premium Acrylic Emulsion Paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces(tint and pattern as approved by GE) complete all as specified. Note:- This item includes use of necessary scaffolding, Jhulla arrangement and safety net up to G+5 storey building. |
| 35 | M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls including pillasters and cornices etc. including washing, rubbing down and stopping the previously treated surfaces and applying two coats of Oil Emulsion Distemper of approved shade/tint over and including one coat of 1 mm thick Birla wall care putty to achieve smooth finish complete all as specified and directed. |
| 36 | M&L for preparation of old decorated surfaces of wall (plastered or un-plastered) including cornices, pilaster etc by brooming down with steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying one coat distemper oil bound emulsion (white or tinted) on walls complete all as specified and directed. |
| 37 | M&L preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coats of Synthetic Enamel Paint of tint / shade as approved complete all as specified and directed. |
| 38 | M&L for preparation of old painted steel or iron surfaces of any description over 10cm width or girth and applying two coats of Synthetic Enamel Paint of tint as approved complete all as specified and directed. |
| 39 | M&L preparing old painted concrete surfaces such as chequered tiles, paver blocks, kerb stones etc and similar surfaces over 10 cm width or girth and applying two coats of Synthetic Enamel Paint over a coat of Primer complete all as specified and directed. |
| 40 | S&F Double roller Zebra Venetian blinds consisting of Mounting Pelmet assembly, Aluminium head rail with flip cover of approved tint/shade and traverse cord complete as per manufacturers instruction fixed in position including taking down old blinds complete all as specified and directed by Engineer-in-Charge. |
| 41 | Taking down chowkhats or frames with shutter (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqm and making good to disturbed surface without any extra cost complete all as specified and directed. |
| 42 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not excceeding 1.5 Sqm and making good to disturbed surface without any extra cost complete all as specified and directed. |
| 43 | S&F anodised aluminium powder coating aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 44 | S&F anodised aluminium Powder coating door shutters aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, hinges, anodised aluminium snap beading screws, all necessary builders hardware etc complete all as specified and directed. |
| 45 | S&F anodised aluminium Powder coating window and ventilator shutters, side hung type without sash bars aluminium section weighing not less than 0.55Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100mm long (2 No.) suitable handle (1 No) including all necessary builders hardware complete all as specified and directed. |
| 46 | S&F 12 mm thick particle board exterior grade with decorative prelaminated both sides of approved shades fixed to aluminium shutters/ partitions complete all as specified and directed. |
| 47 | S&F 4.8mm thick sheet glass ordinary quality in Square/rectangle fixed with glazing pins and rubber beading etc in aluminium door/window/partitions etc complete all as specified and directed. |
| 48 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided. |
| 49 | M&L RCC (1:2:4) type B-1, (using 20mm graded stone aggregate) for slabs supports on walls. |
| 50 | S&F of TMT bars 10mm diameter and over cut to length bend to shape required including cranking bending. |
| 51 | Use and waste of fromwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface flat for rough finished surface of concrete complete all as specified and directed. |
| 52 | Use & waste of fromwork to edge of concrete flats etc exceeding 10cm but not exceeding 20cm wide/thick for fair finished surface of concrete all as specified. |
| 53 | M&L for providing precast cover slab in PCC (1:2:4), Type B1, (using 20mm graded stone aggregate) for drains with perforated hole as per the direction given by the Engineer-in-Charge. |
| 54 | Repairing of rolling shutter push type with necessary repair work of defective parts i.e., reposting of laths, riveting to old defective rivets, tightening nuts and bolts, replacement of spring, greasing to movable parts and at guide channel including taking out and re-fixing rolling shutter for smooth functioning size of rolling shutter not exceeding 6 Sqm each all as directed by Engineer-in-Charge. |
| 55 | S&F in repairs mild steel plain sheets covering to door shutter and top cover of rolling shutter cover cut to size, edges beaded as directed, holes punched all as specified |
| 56 | Removing Debris/ demolished materials by mechanical means including loading, transporting, unloading to outside MoD land from 5 Km upto 20Km lead at municipal dumping ground complete as per direction of Engineer-in-Charge. |
| 57 | Dismantling floor, earth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. |
| 58 | M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge. |
| 59 | M&L Glazed Ceramic tiles (300 mm x 450 mm/ 300 mm x 600 mm) x 7 to 8 mm thick coloured tiles in vertical surfaces, wall claddings, boundary wall dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match as in dado over 10 mm thick cement plaster in CM (1:4) complete all as specified and directed. |
| 60 | M&L Non-Skid, Ceramic Colored tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors, set and jointed in cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed 15mm thick average in CM (1:6) complete all as specified and directed. |
| 61 | M&L for Vitrified Ceramic light shade tiles 8 to 9 mm thick polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry, over and including 15 mm thick screed bed in CM (1:6) and pointed in white or coloured cement to match complete all as specified and directed. |
| 62 | M&L for PCC (1:4:8) type D-2, (1:4:8) (using 40mm graded stone aggregates) for sub bases of floor, mass concrete finished even and rough to receive topping layer complete all as specified and directed by Engineer-in-Charge. |
| 63 | M&L PCC type C-2, (1:3:6) (using 40mm graded stone aggregate) as in plinth protection 75mm thick laid in bays and surfaces finished even and smooth without using extra cement complete all as specified . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysDec 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender