Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58398881

Tender For 1) annual repair maintenance Various Electrical Installation And Mechanical Equipment Of 119 Type-Iii, Residential Quarters For The Staff Of Gnctd Of Delhi At Sector - 11, Rohini, Delhi. 2) repair maintenance electrical installation & Fans

Issued by Government Departments · Delhi, Delhi
Tender Value
47.33 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
6 days left
EMD
94663
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for 1) annual repair maintenance Various Electrical Installation And Mechanical Equipment Of 119 Type-Iii, Residential Quarters For The Staff Of Gnctd Of Delhi At Sector - 11, Rohini, Delhi. 2) repair maintenance electrical installation & Fans, Pump Set, Dg Set, Street Light In Division Office And Circle Office Under Isbt Flyover, Kashmere Gate, Delhi - 110006. (Sh: Maintenance Of electrical installation & Fans, Operation Of Pumps, Dg Set)

BOQ

Name of Work:- 1) ARMO Various Electrical Installation and Mechanical Equipment of 119 type-III, Residential Quarters for the staff of GNCTD of Delhi at Sector - 11, Rohini, Delhi. 2) RMO EI & Fans, Pump set, DG Set, Street Light in Division Office and Circle Office under ISBT Flyover, Kashmere Gate, Delhi - 110006. (SH: Maintenance of EI & Fans, Operation of Pumps, DG Set)
Sl. No. Item Description
1SUB HEAD - I (Maintenance of EI & Fans at Residential Staff Quarters at Sector - 11, Rohini)Running maintenance and operation of all EI wiring, Light points / Fan Points / Exhaust Fan Points / Call Bell Points, Light / Power Plug Points, AC Points, EDB, Main Board, Street Light Points, Glow Sign Boards, Fittings, Ceiling Fans, Exhaust Fans, Brass Batten / Angle Holder, Call Bells, Buzzer etc. and operation of drinking and horticulture water pump sets by deputing the following experience staff including Sunday and holidays as per terms and conditions attached.Staff engaged by the contractora) Wireman cum operator : 02 Nos. in (One No. in each shifts, 6 AM to 2 PM & 2 PM to 10 PM)b) Khallasi : 02 Nos. in (One No. in each shifts, 6 AM to 2 PM & 2 PM to 10 PM)
2SUB HEAD - II (Maintenance of EI & Fans at PWD Offices at Below ISBT Flyover)Maintenance and Upkeeping of all the internal electrical installations, pumpsets including compound lights and recording and monitoring of the complaints including cleaning of all EI and Fans etc., operation of water cooled 25 KVA DG Set manually operated battery charger on all working days (excluding sundays & Holidays) in general shift complete as per terms and conditions, detail of staff etc as required. Staff engaged by the contractora) Wireman cum operator : 01 No. in General shift
3Providing services of commercial inspection vehicle (Light Motor Vehicle) with fuel including driver having valid driving license from 09:00 A.M. to 06:00 P.M. on all working days of the month except sundays and holidays, as per instruction/directions of Engineer-in-charge and 2500 km per month, etc as reqd.
4a) Extra charges for providing services of Driver after normal office hours as per instruction/direction of Engineer-in-charge, as and when required.
5upplying of following electrical accessories (i/c dismantling) suitable for existing different type fitting/switch box etc. for dispensing complaints on day to day basis as required .(Excluding Labour cost which is already included in Item 1&2 )a) S.P. 5/6 A, one way switch, piano type ISI marked
6b) S.P. 15/16 A, one way switch, piano type ISI marked
7c)6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
8d) Piano type electronic fan regulator socket type
9e) Bell push, piano type
10f) Call bell/ buzzer, single phase
11g) 2.5 MFD Capacitor
12h) 3.15 MFD Capacitor
13i) S.P. 5/6 A, one way modular switch, ISI marked
14j) 3 pin 5/6 A modular socket outlet, ISI marked
15k) S.P. 15/16 A, one way modular switch, ISI marked
16l) 6 pin 15/16 A modular socket outlet, ISI marked
17m) Modular base & cover plate for 3 module
18n) Modular base & cover plate for 4 module
19o) Modular base & cover plate for 6 module
20p) Modular base & cover plate for 8 module
21q) Modular base & cover plate for 12 module
22r) PVC batten/ Angle holder
23s) 3 mm thick phenolic laminated sheet
24t) 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
25u) 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
26v) 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
27w) 6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity
28x) 6 A to 32 A ratings, DP MCB, “C” curve, 10 kA breaking capacity
29y) 63 A DP MCB \\"C\\" curve 10 kA Breaking Capacity
30z) 63 A Rating, 2 Pole RCCB, 30 mA
31aa) 4 pole MCCB,100A,30kA
32ab) 4 pole MCCB, 200A, 36kA
33ac) Sheet steel DP MCB enclosure
34ad) 300 mm 1400 RPM heavy duty exhaust fan ISI Mark
35ae) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req.1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
36af) Stepped type Modular Fan regulator (2 module)
37LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. a) 18 watt
38LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18-22 Watt
39Supplying of Fancy wall bracket in stainless steel base duly wired with B-22 lamp holder suitable for CFL lamp/LED Retrofit lamp complete with all accessories i/c connection etc as required but without lamp.
40Supplying of surface mounted IP65 rated LED bulkhead luminaire of nominal lumen output of 700 lumens with minimum efficacy of 100 lms/watt with glare free polycarbonate diffuser having colour temperature of 6500k, CRI>80 in aluminium housing body complete with all accessories with suitable LED driver etc. including PVC connector & PVC flexible conduit from light point to fitting and connection with 3 x 1.5 sq. mm copper wiring etc. complete as reqd.
41LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials. a) 70 Watt
42b) 100 watt
43c) 250 watt
44LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.72 Watt
45Supply Of New Generation IP65 LED, 40 Watt post top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications complete etc. as required at site.
46Supply of surface/ recess mounted type Luminaries, glare free opal diffuser LED Panel of Nominal size 1180x280 mm suitable for Armstrong / POP / GB ceiling with made out of CRC / MS Powder coated housing. Having the following specifications :i) Total System Lumens - 36 Watt, ii) Color Temperature - 5700 K to 6500 K, iii) Power Factor - > 0.95iv) CRI - > 80, v) System Lumen Efficiency - = > 100 LM/W,including connections, testing etc complete as required.
47LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 36 watt
48Supply of wall fan 400 mm sweep oscillating type having plastic blade complete with all accessories such as front jaali i/c connection etc. as reqd.
49Rewinding of following size Submersible/Mono submersible/monoblock pumpset i/c dismantling of pumpset from site, cartage from site to work shop and return back, cutting the burnt winding wire (credit for old winding wire) & rewinding the same with PVC insulated copper winding wire etc. as reqd.a) 10 Hp
50Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required a) Group A
51Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. a) Group A
52SH :- III Repairing in Newly Alloted QuarterRewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. a) Group A
53Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm
54b) 25 mm
55Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm
56b) 3 x 4 sq. mm
57c) 3 x 6 sq. mm
58Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. a) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
59Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 1 or 2 Module (75mmX75mm)
60b) 3 Module (100mmX75mm)
61b) 4 Module (125mmX75mm)
62c) 6 Module (200mmX75mm)
63d) 8 Module (125mmX125mm)
64e) 12 Module (200mmX150mm)
65Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch
66b) 3 pin 5/6 A socket outlet
67c) 15/16 A switch
68d) 6 pin 15/16 A socket outlet
69g) Bell push
70Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
71Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
72Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
73Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
74Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
75Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
76Supplying and fixing PVC batten/ angle holder including connections etc. as required.
77Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
78Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
79Supplying and fixing of Fancy wall bracket in stainless steel base duly wired with B-22 lamp holder suitable for CFL lamp/LED Retrofit lamp complete with all accessories i/c connection etc as required with lamp.
80Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 16 way, Double door
81Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole
82b) Double pole
83Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A
84SITC of surface mounted IP65 rated LED bulkhead luminaire of nominal lumen output of 700 lumens with minimum efficacy of 100 lms/watt with glare free polycarbonate diffuser having colour temperature of 6500k, CRI>80 in aluminium housing body complete with all accessories with suitable LED driver etc. including PVC connector & PVC flexible conduit from light point to fitting and connection with 3 x 1.5 sq. mm copper wiring etc. complete as reqd.
85Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 18- 22 Watt
86Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
87Supplying & fixing of 300 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd.
88Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 40 A
89SH :- IV Annual Comprehensive Maintenance of DG Set Kashmere GateAnnual comprehensive maintenance of Kirloskar make 25 KVA DG Set installed at below ISBT flyover including routine servicing, cleaning, checking, attending to minor/ major repairs & carrying out schedule maintenance at every 6 months.
90Carrying out of 'B' check spares in DG Set including replacement of following parts testing and commissioning etc. complete as required, (Labour included in AMC scope). a) Lube Oil Filter Element
91b) Fuel Filter Kit 0.5 Ltr
92c) Koel Care Premium genuine Oil 13- Ltr
93d) Koel Care Genuine Coolant Premix 05- Ltr Can
94i) Battery Charger 10A 12 VDC
95j) 12V DC, 130Ah Lead Acid Kirloskar Green Battery Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58398881
AUTHORITY Government Departments
TENDER VALUE 47.33 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for 1) annual repair maintenance Various Electrical Installation And Mechanical Equipment Of 119 Type-Iii, Residential Quarters For The Staff Of Gnctd Of Delhi At Sector - 11, Rohini, Delhi. 2) repair maintenance electrical installation & Fans, Pump Set, Dg Set, Street Light In Division Office And Circle Office Under Isbt Flyover, Kashmere Gate, Delhi - 110006. (Sh: Maintenance Of electrical installation & Fans, Operation Of Pumps, Dg Set)
Basic Detail
Tender No 69/EE(E)/NWED/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 05 Nov 2026
Submission Date 12 Nov 2026
Open Date 12 Nov 2026
Finance
Tender Value 47.33 Lakhs
Tender Fee Ref. Documents
EMD 94663
Exemption Available
Document List
642cb89f-8d11-4813-896d-80798123fdfa.html
BOQ_401786.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

642cb89f-8d11-4813-896d-80798123fdfa.html

xls

BOQ_401786.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender