Tender For 1) annual repair maintenance Various Electrical Installation And Mechanical Equipment Of 119 Type-Iii, Residential Quarters For The Staff Of Gnctd Of Delhi At Sector - 11, Rohini, Delhi. 2) repair maintenance electrical installation & Fans
Tender Overview
Project Description
Tender for 1) annual repair maintenance Various Electrical Installation And Mechanical Equipment Of 119 Type-Iii, Residential Quarters For The Staff Of Gnctd Of Delhi At Sector - 11, Rohini, Delhi. 2) repair maintenance electrical installation & Fans, Pump Set, Dg Set, Street Light In Division Office And Circle Office Under Isbt Flyover, Kashmere Gate, Delhi - 110006. (Sh: Maintenance Of electrical installation & Fans, Operation Of Pumps, Dg Set)
BOQ
| Sl. No. | Item Description |
| 1 | SUB HEAD - I (Maintenance of EI & Fans at Residential Staff Quarters at Sector - 11, Rohini)Running maintenance and operation of all EI wiring, Light points / Fan Points / Exhaust Fan Points / Call Bell Points, Light / Power Plug Points, AC Points, EDB, Main Board, Street Light Points, Glow Sign Boards, Fittings, Ceiling Fans, Exhaust Fans, Brass Batten / Angle Holder, Call Bells, Buzzer etc. and operation of drinking and horticulture water pump sets by deputing the following experience staff including Sunday and holidays as per terms and conditions attached.Staff engaged by the contractora) Wireman cum operator : 02 Nos. in (One No. in each shifts, 6 AM to 2 PM & 2 PM to 10 PM)b) Khallasi : 02 Nos. in (One No. in each shifts, 6 AM to 2 PM & 2 PM to 10 PM) |
| 2 | SUB HEAD - II (Maintenance of EI & Fans at PWD Offices at Below ISBT Flyover)Maintenance and Upkeeping of all the internal electrical installations, pumpsets including compound lights and recording and monitoring of the complaints including cleaning of all EI and Fans etc., operation of water cooled 25 KVA DG Set manually operated battery charger on all working days (excluding sundays & Holidays) in general shift complete as per terms and conditions, detail of staff etc as required. Staff engaged by the contractora) Wireman cum operator : 01 No. in General shift |
| 3 | Providing services of commercial inspection vehicle (Light Motor Vehicle) with fuel including driver having valid driving license from 09:00 A.M. to 06:00 P.M. on all working days of the month except sundays and holidays, as per instruction/directions of Engineer-in-charge and 2500 km per month, etc as reqd. |
| 4 | a) Extra charges for providing services of Driver after normal office hours as per instruction/direction of Engineer-in-charge, as and when required. |
| 5 | upplying of following electrical accessories (i/c dismantling) suitable for existing different type fitting/switch box etc. for dispensing complaints on day to day basis as required .(Excluding Labour cost which is already included in Item 1&2 )a) S.P. 5/6 A, one way switch, piano type ISI marked |
| 6 | b) S.P. 15/16 A, one way switch, piano type ISI marked |
| 7 | c)6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked |
| 8 | d) Piano type electronic fan regulator socket type |
| 9 | e) Bell push, piano type |
| 10 | f) Call bell/ buzzer, single phase |
| 11 | g) 2.5 MFD Capacitor |
| 12 | h) 3.15 MFD Capacitor |
| 13 | i) S.P. 5/6 A, one way modular switch, ISI marked |
| 14 | j) 3 pin 5/6 A modular socket outlet, ISI marked |
| 15 | k) S.P. 15/16 A, one way modular switch, ISI marked |
| 16 | l) 6 pin 15/16 A modular socket outlet, ISI marked |
| 17 | m) Modular base & cover plate for 3 module |
| 18 | n) Modular base & cover plate for 4 module |
| 19 | o) Modular base & cover plate for 6 module |
| 20 | p) Modular base & cover plate for 8 module |
| 21 | q) Modular base & cover plate for 12 module |
| 22 | r) PVC batten/ Angle holder |
| 23 | s) 3 mm thick phenolic laminated sheet |
| 24 | t) 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 25 | u) 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 26 | v) 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 27 | w) 6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity |
| 28 | x) 6 A to 32 A ratings, DP MCB, “C” curve, 10 kA breaking capacity |
| 29 | y) 63 A DP MCB \\"C\\" curve 10 kA Breaking Capacity |
| 30 | z) 63 A Rating, 2 Pole RCCB, 30 mA |
| 31 | aa) 4 pole MCCB,100A,30kA |
| 32 | ab) 4 pole MCCB, 200A, 36kA |
| 33 | ac) Sheet steel DP MCB enclosure |
| 34 | ad) 300 mm 1400 RPM heavy duty exhaust fan ISI Mark |
| 35 | ae) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req.1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 36 | af) Stepped type Modular Fan regulator (2 module) |
| 37 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. a) 18 watt |
| 38 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18-22 Watt |
| 39 | Supplying of Fancy wall bracket in stainless steel base duly wired with B-22 lamp holder suitable for CFL lamp/LED Retrofit lamp complete with all accessories i/c connection etc as required but without lamp. |
| 40 | Supplying of surface mounted IP65 rated LED bulkhead luminaire of nominal lumen output of 700 lumens with minimum efficacy of 100 lms/watt with glare free polycarbonate diffuser having colour temperature of 6500k, CRI>80 in aluminium housing body complete with all accessories with suitable LED driver etc. including PVC connector & PVC flexible conduit from light point to fitting and connection with 3 x 1.5 sq. mm copper wiring etc. complete as reqd. |
| 41 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials. a) 70 Watt |
| 42 | b) 100 watt |
| 43 | c) 250 watt |
| 44 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.72 Watt |
| 45 | Supply Of New Generation IP65 LED, 40 Watt post top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications complete etc. as required at site. |
| 46 | Supply of surface/ recess mounted type Luminaries, glare free opal diffuser LED Panel of Nominal size 1180x280 mm suitable for Armstrong / POP / GB ceiling with made out of CRC / MS Powder coated housing. Having the following specifications :i) Total System Lumens - 36 Watt, ii) Color Temperature - 5700 K to 6500 K, iii) Power Factor - > 0.95iv) CRI - > 80, v) System Lumen Efficiency - = > 100 LM/W,including connections, testing etc complete as required. |
| 47 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 36 watt |
| 48 | Supply of wall fan 400 mm sweep oscillating type having plastic blade complete with all accessories such as front jaali i/c connection etc. as reqd. |
| 49 | Rewinding of following size Submersible/Mono submersible/monoblock pumpset i/c dismantling of pumpset from site, cartage from site to work shop and return back, cutting the burnt winding wire (credit for old winding wire) & rewinding the same with PVC insulated copper winding wire etc. as reqd.a) 10 Hp |
| 50 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required a) Group A |
| 51 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. a) Group A |
| 52 | SH :- III Repairing in Newly Alloted QuarterRewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. a) Group A |
| 53 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm |
| 54 | b) 25 mm |
| 55 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm |
| 56 | b) 3 x 4 sq. mm |
| 57 | c) 3 x 6 sq. mm |
| 58 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. a) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 59 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 1 or 2 Module (75mmX75mm) |
| 60 | b) 3 Module (100mmX75mm) |
| 61 | b) 4 Module (125mmX75mm) |
| 62 | c) 6 Module (200mmX75mm) |
| 63 | d) 8 Module (125mmX125mm) |
| 64 | e) 12 Module (200mmX150mm) |
| 65 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch |
| 66 | b) 3 pin 5/6 A socket outlet |
| 67 | c) 15/16 A switch |
| 68 | d) 6 pin 15/16 A socket outlet |
| 69 | g) Bell push |
| 70 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 71 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 72 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 73 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 74 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 75 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 76 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 77 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 78 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 79 | Supplying and fixing of Fancy wall bracket in stainless steel base duly wired with B-22 lamp holder suitable for CFL lamp/LED Retrofit lamp complete with all accessories i/c connection etc as required with lamp. |
| 80 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 16 way, Double door |
| 81 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 82 | b) Double pole |
| 83 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A |
| 84 | SITC of surface mounted IP65 rated LED bulkhead luminaire of nominal lumen output of 700 lumens with minimum efficacy of 100 lms/watt with glare free polycarbonate diffuser having colour temperature of 6500k, CRI>80 in aluminium housing body complete with all accessories with suitable LED driver etc. including PVC connector & PVC flexible conduit from light point to fitting and connection with 3 x 1.5 sq. mm copper wiring etc. complete as reqd. |
| 85 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 18- 22 Watt |
| 86 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 87 | Supplying & fixing of 300 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd. |
| 88 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 40 A |
| 89 | SH :- IV Annual Comprehensive Maintenance of DG Set Kashmere GateAnnual comprehensive maintenance of Kirloskar make 25 KVA DG Set installed at below ISBT flyover including routine servicing, cleaning, checking, attending to minor/ major repairs & carrying out schedule maintenance at every 6 months. |
| 90 | Carrying out of 'B' check spares in DG Set including replacement of following parts testing and commissioning etc. complete as required, (Labour included in AMC scope). a) Lube Oil Filter Element |
| 91 | b) Fuel Filter Kit 0.5 Ltr |
| 92 | c) Koel Care Premium genuine Oil 13- Ltr |
| 93 | d) Koel Care Genuine Coolant Premix 05- Ltr Can |
| 94 | i) Battery Charger 10A 12 VDC |
| 95 | j) 12V DC, 130Ah Lead Acid Kirloskar Green Battery Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender