Tender For Special Repair To Bldg No. 163 (Dhobi Ghat) Of 3 Ttr At Bambolim Camp Under Ge Panaji (Goa)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Nov-2026 8352 BOQ Corrigendum BOQ 26-Nov-2026

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO. 163 (DHOBI GHAT) OF 3 TTR AT BAMBOLIM CAMP UNDER GE PANAJI (GOA)
Sl. No. Item Description
1Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings.
2Dismantling of timber scantling under 40 Sq cm in section in any position as in unframed work fillets, rails, posts, rafters, purlins etc
3Dismantling of ceiling boards any thickness including cover fillets.
4S&F for Rolled sections as in main andcross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (GdeE- 250) qualityA
5S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment etc
6M& L for Formwork to bed plates sides of pillars,posts, struts, piers, columns and stanchions → (horizontal or sloping) complete all as specified and directed.
7M& L for PCC type B1 1:2:4 (20mm graded aggregate) for Bed block Providing, cement concrete in roof kerbs or mud stops,benching rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; in benching on chajja,parapet wall and sides of wall etc.seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not rovided for watertroughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
8Dismantling wrought iron or mild steel work of any description not otherwise and refixing in other opening with PCC 1:2:4 type B2 area not exc 1sqm for each angle etc
9M & L for Preparation of New steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified.
10S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and necessary groove cutting in existing walls, including filling of gaps between wall and sheet with CM 1:4, complete all as specified and directed by Engr-in-Charge.
11S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and necessary groove cutting inn existing walls, including filling of gaps between wall and sheet with CM 1:4, complete all as specified and directed by Engr-in-Charge.
12S&F for false ceiling work of aluminium anodised snap grid frame work, size of grid 605 X 605mm , 6mm thick Everest designer boards or equivelent fixed Aluminium frame work with screws, including hangers 6mm dia, G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 X 3mm size 60mm long as in ceilings complete all as specified.
13Supply only integral waterproofing compound
14Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc.
15Demolition of brickwork or stone/boulder masonry, built in CM including all quoins arches pillars etc.
16M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 etc
17M&L for 10 mm thick cement plaster 1:6 on Brick or concrete surface finished even and smooth without using extra cement all as specified
18M&L 15mm thick plastering on fair faces of bricks or concret surfaces finished even and smooth w/o using extra cement in cm1:4. The plaster shalll be done in two coats of 10mm and 5mm respectively, as directed by Engr-In-Charge
19M&L for two coat of oil bound distemper over wall care putty finish on wall over plastered surfaces including prepartion of new surfaces on plastered surfaces, preparatory to distempering complete all as specified and directed
20M&L for preparation of new plastered surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489-2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm on new surface complete all as specified and directed. Note: 1. The rubbing down and stopping of old surfaces shall be done by jet washing (90 to 150 bar as required), and painting shall be done with a fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. 2. MOU between contractor and approved paint manufacturer shall be submitted by Contractor for Pre,during and Post work completion site inspections.
21M&L for complete removal of existing surface and preparation of old plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489-2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm on old surface complete all as specified and directed. Note: 1. The rubbing down and stopping of old surfaces shall be done by jet washing (90 to 150 bar as required), and painting shall be done with a fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. 2. MOU between contractor and approved paint manufacturer shall be submitted by Contractor for Pre,during and Post work completion site inspections.
22M&L for complete removal of existing surface on internal wall and applying two coats of oil bound distember over putty finish complete all as specified and directed.
23Taking down chowkat with shutter(without taking off shutter from the frame) area exc 1.5 sqm but n exc 4 sqm each
24S&F for Powder coated aluminium grill (anodised transparent or dyed to required shade according to IS 1856 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles apparature of diamond shape grills of 75mm and fixing approved powder coated aluminium standard section around the opening all complete as per requirement and direction of engr-in-charge.
25S & F for Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
26S & F Power coated aluminium window and ventilator shutters fixed, openable or sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
27S&F sheet glass ordinary quality and glazing with oil putty/Nerolic rubber beading in square nexc 0.5 sqm each pane 4mm thick complete all as specified and directed by Engr-in-Charge
28S&F Aluminium alloy wire cloth 0.45 mm nominal dia.of wire and average width of aperture 1.40 mm and and fixed with aluminium wire staples/wooden beads fixed.
29Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
30Providing and fixing factory made single extruded WPC (Wood Polymer omposite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with M. S./S.S butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge.
31S&F for Door closer hydraulically regulated,designation No, 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed (aluminium)
32S&F for Floor door stopper of aiuminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor
33S&F for Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 300 mm long.
34S & F Butt hinges, heavy weight, cold rolled mild steel, and fixed 100mm long
35S&F Aluminium anodised, barrel tower bolts of extruded section and fixed 200mm long.
36S & F Aluminium handles cast type anodised 150 mm long.
37M&L for cutting holes in brick walls in built in cement mortar or cement lime mortar and stone walls built in lime mortar exc. Half brick but not exc one brick for inserting holdfasts and making good in dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed
38S&F for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts if required, hooks (stay) heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed
39Demolition of cement concrete in below or above ground floor and paving n.exc 15 cm thk (unreinforced).
40M & L for Cement concrete type C- 2, 1:3:6 (40mm graded stone aggregate) 75mm thick as in sub base.for kota stone , chequered tiles and interlocking tiles
41M&L for hardcore of gauge n. exe 63 mm deposited, spread, levelled in layers n. exe 15 cm thick, watered rammed to a true surface using Broken stone or boulders.
42M & L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates), 75mm thick as in plinth protection, Surface finished fair and smooth without using extra cement.
43M&L for Machine cut kota stone slab flooring 20-25mm thick ncluding 15mm thick screed bed in CM 1:6.over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl Mirror polishing on Kota stone/ stone work where ever required to give high gloss finish incl rubbing and mirror polishing complete etc
44M&L for Machine cut kota slab 20-25mm thick in risers of step skirting dado over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including Mirror polishing Kota stone/ stone work where ever required to give high gloss finish rubbing and mirror polishing including 10mm thick rendering with CM 1:4 and fair faces on brick work or concrete surfaces.
45Demolition of cement concrete in below or above ground floor and paving not exceeding 15 cm thick (reinforced) complete all as specified and directed
46Demolition of concrete (Unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level).
47M&L PCC 1:3:6 type C-2 (40mm graded stone aggregate ) for sub base 75mm thick complete all as specified and directed.
48M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.
49M&L providing cement concrete 1:2:4 type B-1, 20 mm graded agg) as in kerb or mud stops rounded aor chamfered on edges all as specified.
50Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
51Taking down/ dismantling old Main Board with MCBs including meter box and energy meters of any size and capacity alongwith teakwood boards & energy meter keep in safe at MES store for refixing complete all as specified and directed by Engr-in-charge.
52Taking down UNSV sub main wiring of any size make, type and capacity including making good disturbed surfaces complete all as specified and directed.
53M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
54One light point / Fan point ,Bell point controlled by one, one-way switch
55One switch socket outlet 3 pin 5 Amps, on Same board
56One switch socket outlet 2/3 pin 5 Amps, on Independent board.
57All as per item No 53 above but with 2.5 sqmm PVC insulated FRLS, multistranded copper conductor cable 1100 V grade and 2.5 Sqmm PVC insulated FRLS multistranded copper conductor cable 1100 V grade for one 3 pin, 5/15 Amps switch socket outlet on independent board complete including taking down of old U/S point wiring all as specified and directed.
58All as per item No 53 above but with 4.0 sqmm PVC insulated FRLS, multistranded copper conductor cable 1100 V grade and 4.0 Sqmm PVC insulated FRLS multistranded copper conductor cable 1100 V grade for one 5 pin, 5/15 Amps switch socket outlet on independent board complete including taking down of old U/S point wiring all as specified and directed.
59Supply and fixing in replacement, including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed.
60Supply & fixing in replacement, including connection modular Switch socket combination 2 in 1,6 pin 16 amps 3 modules complete all as specified and directed.
61Supply & fixing in replacement, including connection modular Switch socket combination 2 in 1,5 pin 5 amps 3 modules complete all as specified and directed.
62S&F in replacement, Ceiling rose surface bakelite 65x50mm two to three terminal complete all as specified and directed.
63Supply and fixing in replacement, lamp holder PVC /Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
64Supply and fixing in replacement,LED lamp 09 Watt complete all as specified and directed.
65Supply and fixing in replacement of Modular Fan regulator,120 watts as directed and specified by Engineer-in-charge.
66Supply and fixing in replacement, High-quality design LED Tube light fittings in extruded aluminium housing with high quality PC diffuser 1x20 watt with enhances safety and relible ,robust housing structure with efficiency of 120 lm/W ,decorative end caps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
67S&F in replacement, LED Building security light fitting 35 Watt, new generation, energy saving and environmental friendly, long life LED street light made up of pressure die-cast housing with prisma as tic polycarbonate modular secondary lense optic for city road lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK08. 4KV inbuild surge protection of capacity LED including all accessories complete all as specified and as directed by Engr-in-charge.
68M&L for Bracket made out of GI pipe 25 mm dia medium grade, .85 meter long bent to shape fixed with MS flat irom clamps made out of 25mm x 6 mm thick, nuts bolts complete all as specified and directed.
69Supply and fixing in replacement of IP-43, protection VTPN MCB Distribution board with MCCB as incommer 4 way, 440 V AC, made out of CRCA sheet steel, powder coated, RAL 9003, double door with glazed type, ready to use MCB DB provided with 160 Amps insulated vertical colour coded phase/ neutral bus bars with shrouds, earth bars, stiching saddles, cement spill protector, with colour coaded inter connecting wire set, cable ties and with circut label identification for provision of MCCB /RCCB as incommer up to 125 Amps and MCB TP/SPs as outgoings etc, flushed to wall, including making good the disturbed surfaces complete all as specified and as directed. Note: MCCB's/RCCB's/MCB's will be measured and paid separately under relevant items of this schedule.
70S&F MCCB 4 pole, 160 Amps, C curve, breaking capacity 16 kA, |lcs=100%lcu complete with connection, testing and commissioning including spreader link & taking down complete all as specified and directed.
71S&F in replacement, IP-42 protection distribution board, SPN 8 Way, 240 Volts, sheet steel, powder coated, double door system, fitted with two covers suitable for use on 240 V, 50 HZ, with 200 Amps rated bus bar, neutral link each bar and din rail complete all as specified and directed.
72S&F in replacement, IP-42 protection distribution board, SPN 4 Way, 240 Volts, sheet steel, powder coated, double door system, fitted with two covers suitable for use on 240 V, 50 HZ, with 200 Amps rated bus bar, neutral link each bar and din rail complete all as specified and directed.
73Supply and fixing in replacement, MCB SPN 40-63 Amp, 240V, 10KA, 'C' curve complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
74Supply and fixing in replacement, MCB TPN 40-100 Amp, 240V, 10KA, 'C' curve complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
75Supply and fixing in replacement, MCB SP 6-32 Amp, 10KA, 'C' curve complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
76S&F in replacement, GI tubing light grade 40 mm bore for protection of cable fixed in wall or laid in trenches including taking down old unserviceable GI tubing complete all as specified and directed.
77Taking down fan ,Cealing cable end,dismaintiling blades and removing fan and blade to MES Store yard to store complete all as specified and as directed.
78Hanging only ceiling fan and connecteing up including provision of cable from ceiling rose/connector to fan complete all as specifed and as direcetd
79S&F PVC insulated, sheathed twin twisted stranded copper conductor flexible cable of size 1.5 Sqmm for ceiling fan as specified and directed.
80Taking down E/fan and removing fan and blade to MES Store yard to store complete all as specified and as directed.
81Hanging only E.Fan and connecteing up including provision of cable from ceiling rose/connector to fan complete all as specifed and as direcetd
82S&F in repalcement of louvers shutter made of MS sheet metal 1.2mm thick for round base and 0.8mm thick for flaps confirming of mounting edges frames made of MS Flat of size 25mmx3mm including heavy duty rust proof passivated bolts, of size 50mm long 8mm dia to be fixed on wall after drilling and duly painted by two coats of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fans up to size 380 mm sweep complete all as specified and directed.
83M&L for making opening/hole suitable for fixing exhaust fan 200/300mm sweep including wooden bedding for fixing of exhaust fan and plastering finishing and making good the existing surface complete all as directed.
84Supply and fixing of switched wall socket interlocking Sockets for wall mounting 3 pole ,Neutral and earth wire 32 Amps IP-44complete all as specified and as directed.
85Supply and fixing of switched wall socket interlocking Sockets for wall mounting 3 pole ,Neutral and earth wire 63 Amps IP-44complete all as specified and as directed.
86M&L for submain wiring with approved colour coding as per IS with with two runs of single core PVC insulated FRLSH cable with stranded copper conductor of size 2.5 sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivery colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc including all conduit acessories/ fittings/junction box/ inspection covers etc of heavy grade, ISI marked with one run of 2.5 Sqmm PVC insulated FRLSH, unshethed multistranded copper conductor cable as a continuous earth wire complete all as specified.Note: (a) Two runs of 2.5 Sqmm single core copper cables and One run of earth conductor cable of 2.5 Sqmm with casing capping/conduit will be measured and paid as one unit length.
87Ditto as per item No 83 above but for cable of size 4.00 sqmm
88M&L for submain wiring with approved colour coding as per IS with with four runs of single core PVC insulated FRLSH cable with stranded copper conductor of size 10 sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivery colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc including all conduit acessories/ fittings/junction box/ inspection covers etc of heavy grade, ISI marked with one run of 10 Sqmm PVC insulated FRLSH, unshethed multistranded copper conductor cable as a continuous earth wire complete all as specified.Note: (a) Two runs of 10 Sqmm single core copper cables and One run of earth conductor cable of 10 Sqmm with conduit will be measured and paid as one unit length.
89M&L for submain wiring with approved colour coding as per IS with with four runs of single core PVC insulated FRLSH cable with stranded copper conductor of size 16sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivery colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc including all conduit acessories/ fittings/junction box/ inspection covers etc of heavy grade, ISI marked with one run of 16 Sqmm PVC insulated FRLSH, unshethed multistranded copper conductor cable as a continuous earth wire complete all as specified.Note: (a) four runs of 16 Sqmm single core copper cables and One run of earth conductor cable of 16 Sqmm with /conduit will be measured and paid as one unit length.
90M&L for earthing in repair complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (1991) all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58398300
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 19.85 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No. 163 (Dhobi Ghat) Of 3 Ttr At Bambolim Camp Under Ge Panaji (Goa)
Basic Detail
Tender No 8352/E8
Bidding Type Tender
Location
City panaji
State Goa
Key Dates
Publish Date 10 Nov 2026
Submission Date 26 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 19.85 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
BOQ_894451.xls
Makelist2026-27.pdf
Tenderdocument_1.pdf
Tendernotice_1.pdf
903c874d-fd90-4353-af8e-898c8a6f06b5.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_894451.xls

pdf

Makelist2026-27.pdf

pdf

Tenderdocument_1.pdf

pdf

Tendernotice_1.pdf

html

903c874d-fd90-4353-af8e-898c8a6f06b5.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender