Tender For Transformer Oil Filtration And Servicing Of Switch Gear Systems In Electrical Substation At Csir-Clri, Adyar, Chennai 600020
Tender Value
2.28 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
4 days left
EMD
4562
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Transformer Oil Filtration And Servicing Of Switch Gear Systems In Electrical Substation At Csir-Clri, Adyar, Chennai 600020
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Items |
| 2 | Transformer oil Filtration 1000kVA: Filtration of transformer oil through stream line filter unit to improve the Di-electric strength to the optimum value for 1000kVA transformer and testing & providing the test reports for Di-electric strength and acidity of transformer oil, including the transport charges for transformer oil filter unit with oil testing equipments to site & retun back. |
| 3 | Transformer oil Filtration 1600kVA: Filtration of transformer oil through stream line filter unit to improve the Di-electric strength to the optimum value for 1600kVA transformer and testing & providing the test reports for Di-electric strength and acidity of transformer oil, including the transport charges for transformer oil filter unit with oil testing equipments to site & retun back. |
| 4 | Silica Gel Breather: Supply, installation, testing & commisioning of Dehydrating Silica gel (approximately 1kg) breather suitable capacity to 11kVA/430V Distribution Transformer / OLTC of the transformer of different make having rating upto 1600kVA. |
| 5 | Insulation Testing: Testing of 1000kVA & 1600kVA Transformer insulation resistance value checking including primary HT cable & secondary bus duct disconnection and refixing as per original conditions. |
| 6 | Supply of Tranformer oil: Supply & filling of Trasnformer oil as per IS:335/1993 for exisitng 1000kVA & 1600kVA Transformers (Actual quantity will be billed based on the site requirement) |
| 7 | Service of OLTC: Filtration of transformer oil in OLTC (1600kVA Transformer) using stream line filter unit including removing & refilling and checking the condition of moving part spares, internal cleaning, gear alignment checking & T/F oil filling based on requirement (Spares & T/F oil price excluded) as required. |
| 8 | Overhauling and Maintenance of HT OCB: Removing of the existing HT OCB 400A, operation & testing of relays, checking all the parts including the primary & secondary contacts, Cleaning the dust, mechanism checking, lubrication and refixing the same. Measure the insulation resistance values for all poles with open & closed condition including the testing & issuing of test certificates for following: 1. Over current and earth fault relay 2. Auxiliary relay and Instatenous test 3.Master trip relay 4. Under voltage / over voltage relay (Make: Crompton or equivalent) |
| 9 | Overhauling and Maintenance of LT ACB: Removing of the existing LT ACB 3200A, operation & testing of relays, checking all the parts including the primary & secondary contacts, Cleaning the dust, mechanism checking, lubrication and refixing the same. Measure the insulation resistance values for all poles with open & closed condition including the testing & issuing of test certificates for following: 1. Over current and earth fault relay 2. Auxiliary relay and Instatenous test 3.Master trip relay 4. Under voltage / over voltage relay (Make: L&T or equivalent) |
| 10 | Overhauling and Maintenance of LT ACB: Removing of the existing LT ACB 2000A, operation & testing of relays, checking all the parts including the primary & secondary contacts, Cleaning the dust, mechanism checking, lubrication and refixing the same. Measure the insulation resistance values for all poles with open & closed condition including the testing & issuing of test certificates for following: 1. Over current and earth fault relay 2. Auxiliary relay and Instatenous test 3.Master trip relay 4. Under voltage / over voltage relay (Make: English Electric or equivalent) |
| 11 | Preventive maitenance of Main MV panels: Charges for preventive maintenance of Main MV panel, including checking, cleaning and tightining of bus bars bolt&nuts rusted, Main MV Panel out going side tight checked.,etc.as per required. |
| 12 | MV Panel switch Interlock system: Replacement of faulty mechanical interlock system (2 lock -1 ket set) including handle alongwith suitable to existing MV panels switch with other accessories etc., as required. (Tenderer may inspect the existing MV Panel Interlock system before quoting). |
| 13 | Earth Pit testing: Charges for preventive maintenance of existing earth pits, checking, cleaning and tightining of Earth strip/bus bars and replacement of bolt&nuts rusted, measuring of earth values with test certificate, painting of chamber with earth values ,etc.as per required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender