Tender For special Repair To Bldg No P-71 (Under Ground) To Est Edge Data Centre (Edc) At Signal Centre Complex Of Hq 11 Corps And Provn Of Dg Set 63 Kva For Utilize In Offices Of Hq 91 Sub Area Under Ge (W) Jrc
Tender Value
33.61 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
3 days left
EMD
67220
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Bldg No P-71 (Under Ground) To Est Edge Data Centre (Edc) At Signal Centre Complex Of Hq 11 Corps And Provn Of Dg Set 63 Kva For Utilize In Offices Of Hq 91 Sub Area Under Ge (W) Jrc
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing n exc 15 cm deep in soft loose |
| 2 | Excavating loose/soft soil over areas, n exc 1.5 m deep and getting out all as specified and as directed by Engineer-in-charge |
| 3 | Removing excavated material n exc. 100m and depositing where directed at a level n exc. 1.5 m above the starting point as specified and directed |
| 4 | Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) and removing the surplus soil out of Mod land all as specified. |
| 5 | M&L for Roughening surfaces of old concrete floor by wire brushing, picking, sweeping clean and washing down with water to remove dust, etc. |
| 6 | M&L for Brushing neat cement slurry with 3.0 kg of cement per sq. metre over cleaned concrete surfaces all as specified and directed |
| 7 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. |
| 8 | M&L, for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in coping of parapets and or roof kerbs on roof chamfered on edge incl troweling slightly complete all as specified and directed. |
| 9 | M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed. Note :- Water proofing compound shall be measured separately. |
| 10 | Supply only Liquid water proofing compound complete all as specified and as directed of as per manufacturer instruction. |
| 11 | M&L for applying evenly a tack coat of industrial bituminous 85/25 @ 1.20 Kg per squqre mtr including cleaning surfaces. |
| 12 | M&L APP based polymeric membrance minimum weight not less than 3.0 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/sqm) land on primed surface by forced application( sealed by flame) with over lap of 15 cm complete all as specified and directed complete all as spd and directed. |
| 13 | M & L 40mm thick Brick tiles laid on bedding layer of CM 1;3, 15mm thick and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over APP membrane complete all as specified and directed. |
| 14 | M&L for Flush pointing to brick tiles, laid flat in roofs complete all as specified and directed. |
| 15 | S&F Polythene film, black, 50micron laid in floors cpmplete all as specified and directed. |
| 16 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed |
| 17 | M&L Hardcore (broken stone/ boulders) of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface |
| 18 | M&L for 75 mm thick cement concrete (1:3:6) type C-2, using 40mm graded crushed stone aggregate as in plinth protection, path and floor complete all as specified and as directed. |
| 19 | M&L for 25mm thick Cement concrete type B- 1, 1:2:4 (20mm graded aggregate) as in floors/wearing coarse all as specified and as directed by Engineer-in-charge |
| 20 | Taking down cement plaster including raking out joints, hacking for key,scrubbing down with water built in cement mortar complete all as specified and as directed. |
| 21 | M & L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even using extra cement including WPC @ 3% by weight of cement. |
| 22 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base |
| 23 | M&L for preparing of newly plastered surfaces of walls and appying two coats of camouflage paint over a coat of primer complete all as specified and directed. |
| 24 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as spd and directed. |
| 25 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc for shafts, wells, cesspits , manholes pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 26 | Material and labour for cement concrete foundation 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete and under floor as sub base etc, complete |
| 27 | Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:6 complete all as specified and as directed. |
| 28 | M&L for PCC 1:2:4 type B-1(using 12.50 mm graded stone aggregate) as in channels/benching of manhole, drain,laid to shape and slope and surfaces finished even and smooth using extra cement, complete including all form work etc all as specified and directed. |
| 29 | Demolition of floor hearth or wall tiling including cement mortar bedding (not backing) removing serviceable tiles to store and rubbish of the premises |
| 30 | Material and labour for vitrified ceramic tiles 8 to 10 mm thick, light shade, polished area of each tiles n. exc 0.36 Sqm (square / rectangular) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed 15mm thick in cement mortar (1:6) finished rough to fix tiles complete all as specified and directed. |
| 31 | M&L for coloured glazed tiles of size 450x350x7 mm thick in dados/wall set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:4 complete all as specified and directed. (Colour and shade as approved by Engr-In-Charge) |
| 32 | Taking down chowkhats or frame with shutter without taking off shutter from the frames exc 1.5 Sqm but n exc 4.00 sam each all as specified. |
| 33 | S&F powder coated aluminium frame for doors,windows, partitions, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 34 | S&F powder coated aluminium door shutters ,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, 04 Nos butt hinges, 02 Nos Tower bolts, 01 Nos mortice lock, anodised aluminium snap beading screws etc complete all as specified. |
| 35 | S&F powder aluminium window and ventilator shutters (Sliding type ) without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 36 | S&F sheet glass 4.8 mm thick ordinary quality to be fixed in Al frame work in square exc 0.5 sqm in each pane |
| 37 | M&L reinforced Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed |
| 38 | M&L for Mild steel TMT bars 6mm to 8mm dia and over cut to length , bent to shape required, including cranking bending and binding with annealed wire not less than 0.9 mm dia complete. |
| 39 | M&L RCC M-25 grade(20 mm aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed |
| 40 | S&F formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 41 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 42 | M&L sand cushioning to under concrete interlocking paver block including watering & consolidation complete all as specified and directed |
| 43 | M&L 60 mm thick machine pressed precast concrete interlocking paver block any shape & size confirming to IS-15658-2006 of 60mm thickness, M-35 grade with grey cement & pigment |
| 44 | S&F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balustersand similar articles exc 5 kg each all as spd and directed. |
| 45 | Material and labour for Granite (of any type) work 20mm thick machine cut (table rubbed and polished) in steps jambs, pillars, window cills, cooking platforms, shelves in cupboard, handwash places and like including necessary cutting and grooving to walls and making good including 10mm thick in cement mortar (1:3) screed bed or bedding layer and pointing with cement mortar (1:2) with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 46 | M&L Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil. |
| 47 | M & L for PCC (1:2:4) type B-2 (using 20mm graded crushed stone aggregates ) lean concrete as in foundation, filling and mass concrete of post complete all as specified. |
| 48 | S&F rolled sections as in main and cross beams,hip and jack rafters,purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates. confirming to grade Fe-410-W complete all as specified and directed by EIC. |
| 49 | S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of colour (as approved by users) having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws as specified.(Note : Sheet will be Camouflauge pattern colour coated on exposed face) |
| 50 | M&L for Preparing and applying one coat of red oxide primer and two coats of synthetic enamel paint over new steel Surfaces of any description, over 10cm in width or girth |
| 51 | Fibrette Tile made of 'Wood fiber Cement Composite' 1mm width wood fiber 15mm thick size 595x595/ 595X1195 mm having excellent noise absorption of 1 NRC as per ISO: 354, Density 400 Kg/ m3, meets Fire Ratings as per BS 476 Part 5, 6 and 7 class 1 and P, water resistant and thermal insulated. Installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results. |
| 52 | Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors |
| 53 | Taking down main switch / DB as directed by Engineer-In-Charge. |
| 54 | Taking down unserviceable submain/ cable of any size as directed by Engineer-In-Charge. |
| 55 | M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including pressed steel sunken boxes for mounting of switch/sockets and regulator and including cover plate white colour all as specified and directed for:M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including pressed steel sunken boxes for mounting of switch/sockets and regulator and including cover plate white colour all as specified and directed for:a) One 3 pin socket outlet, 5Amps, independent with other switch |
| 56 | b)One 3 pin socket outlet 5 amps on same board with other switches. |
| 57 | c)One light /fan/cell bell point controlled by one one way switch as directed engineer-in-charge |
| 58 | M & L for concealed point wiring complete with 2.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 2.5 sqmm , FRLS type , copper multistranded cable as earth wire including pressed steel sunken boxes for mounting of switch/sockets and regulator and including cover plate white colour all as specified and directed for: |
| 59 | a) Supply and fixing Piano /flush type switch 1 way 16A, |
| 60 | b) Supply and fixing piano flush type socket 1 way 16 amp |
| 61 | c) Supply and fixing piano/flush type switch 1 way 6A, |
| 62 | d) Supply and fixing piano flush socket 1 way 6 amp |
| 63 | Supply and fixing stepped type electronic fan regulator, flush mounting type, suitable for operation on 230 Volts AC, 50 Hz single phase supply, capable of smooth stepwise speed control of ceiling/exhaust/wall mounted fans without humming noise, complete with modular front plate, mounting frame, terminals, fixing screws and all internal connections. The regulator shall be fixed on the existing phenolic laminated sheet/flush box complete with making good disturbed surfaces, removal of the existing defective regulator (if any), reconnection of incoming and outgoing wiring using suitable copper conductors, ferrules, insulation sleeves, screws and all minor accessories required for proper installation. The item includes checking the polarity and tightness of all electrical connections, testing the regulator for proper operation at all speed steps, ensuring smooth and noise-free operation of the connected fan, and commissioning the installation to the complete satisfaction of the Engineer-in-Charge. Complete in all respects as specified and directed by the Engineer-in-Charge. |
| 64 | M & L for supplying and fixing ceiling rose, surface mounting type, made of superior quality bakelite/phenolic moulded insulating material, size 65 mm × 50 mm, complete with three brass terminals, terminal screws, insulating base, cover, fixing screws and all necessary hardware. The item shall include mounting the ceiling rose securely on wall/ceiling, disconnecting and reconnecting existing wiring, providing proper electrical connections with suitable ferrules, insulation sleeves, PVC insulation tape and other minor accessories as required. The work shall include checking the tightness of all terminal connections, ensuring correct polarity, continuity and insulation of the circuit, testing the ceiling rose under normal operating conditions and making good any damage to the existing surface caused during installation. Complete in all respects, including labour, tools & plants and incidental materials, as specified and directed by the Engineer-in-Charge. |
| 65 | Supply and fixing of Sheet Steel Enclosure for Distribution Board (DB), SPN (Single Phase & Neutral), 8 Way, Double Door, suitable for installation of Single Pole MCBs and incomer MCB/Isolator, fabricated from CRCA sheet steel of minimum 1.2 mm thick for box and 1.6 mm thick for mounting plate, treated with seven-tank anti-corrosive process, phosphate coated and finished with epoxy polyester powder coating of minimum 60–80 microns in approved shade |
| 66 | S/F MCB 415 volts,10KA 'c' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commisioning (II) SPN 40 TO 63 AMP |
| 67 | Supply and fixing of Miniature Circuit Breaker (MCB), Single Pole (SP), rated current 6A to 32A, suitable for 240 Volts AC, 50 Hz single-phase supply, having minimum 10 kA breaking capacity (or as specified in BOQ), thermal magnetic trip mechanism for protection against overload and short circuit, C-curve unless otherwise specified, conforming to IS/IEC 60898-1, complete with insulated terminals, positive trip-free mechanism, DIN rail mounting arrangement, all fixing accessories, screws, nuts, washers, ferrules and connections. The MCB shall be housed in the existing/new DB as directed by the Engineer-in-Charge. The item includes testing, commissioning and proving satisfactory operation to the complete satisfaction of the Engineer-in-Charge. |
| 68 | M & L for sub main wiring with TWO core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of suitable size complete with all accessories alongwith provn of 2 run of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor, FRLS type cable as earth wire. (two runs of cable and one run of conduit shall be measured as one length) |
| 69 | M & L for sub main wiring with TWO core PVC insulated and unsheathed cable 4 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of suitable size complete with all accessories alongwith provn of 2 run of 4 sqmm PVC insulated and unsheathed ,multi stranded copper conductor, FRLS type cable as earth wire. (two runs of cable and one run of conduit shall be measured as one length) |
| 70 | S&F LED tube light fitting 20W (Double side) including LED lamp 20W with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.50mm 3 core complete all as specified and directed. |
| 71 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete |
| 72 | Supply and fixing M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings |
| 73 | Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 74 | M & L for taking down carefully the existing unserviceable LT cable and supplying, laying, testing and commissioning of LT cable, 1100 Volts grade, XLPE insulated, PVC sheathed, armoured, aluminium conductor, conforming to IS:7098 (Part-I) and latest amendments, of size 16 Sqmm, 2 Core, laid in trenches, ducts, on walls, ceilings, cable trays or existing supports as required. The item shall include excavation and refilling wherever required, dressing of cable, providing and fixing suitable brass compression cable glands, aluminium crimping type cable lugs, ferrules, PVC identification tags, gland shrouds, hardware, clamps, saddles, cleats, nuts, bolts, washers, insulation tape and all other accessories required for proper termination and commissioning of the cable. Connections at both ends shall be made complete in all respects including dismantling and removal of old unserviceable cable from site of work. Note:- he item shall also include continuity test, insulation resistance (IR) test with 1000 V insulation tester (Megger), polarity check (where applicable), phase identification, earth continuity test, functional testing after termination, trial run under load and commissioning to the complete satisfaction of the Engineer-in-Charge. All test results shall be recorded and submitted before commissioning. Complete in all respects as specified and directed by the Engineer-in-Charge. |
| 75 | Excavation in trenches in soft/lose soil not exceeding 1.5 Mtr wide and not exc 1.5M depth for laying of UG cables and getting out all as specified and directed. |
| 76 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed. |
| 77 | Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed. |
| 78 | Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed. |
| 79 | Supply, Installation, Testing and Commissioning of Diesel Generating Set 63 KVA, 3 Phase, 415 Volts, 1500 RPM, 50 Hz, power factor 0.8 (lagging), complete with AMF Panel, suitably designed to meet latest MoEF & CPCB-IV+ emission and noise norms, generating noise level not exceeding 75 dBA at 1 metre at 75% load under free field conditions.The DG set shall be housed in a factory-built acoustic enclosure fabricated from CRCA sheets, finished in Munsell Green with 11-tank pre-treatment process and UV-resistant powder coating for corrosion protection. The enclosure shall be insulated with fire-retardant Rockwool conforming to IS 8183, provided with top lifting arrangement, AVM pad mounting, hospital-grade silencer with rain cap, external fuel filling arrangement, battery charging alternator, residential silencer, batteries with leads, first fill of lube oil and coolant.The DG set shall be complete with:Rating: 63 kVA (50.4 kW),Voltage: 415 V, 3 Phase, 4 Wire,Frequency: 50 Hz,Speed: 1500 RPMPower Factor: 0.8 Lagging,Engine Starting: 24 V DC Electric Start,DG Controller: PSO-602 / DSE-4520 MKII / ComAp or OEM Standard Controller Overall Approx. Size: 3000 × 1100 × 1850 mm (L × W × H) Fuel Tank Capacity: 200 Litres (minimum) Acoustic Enclosure: CPCB-IV+ approved by National Physical Laboratory (NPL)Remote Monitoring System (Optional): 4G compatible, real-time DG status monitoring, alerts, fault notifications, fuel level monitoring, RS-485 communication interface and location tracking AVM Pad mounting type, 60 Litre DEF Tank capacity, 515 Litre standard fuel tank capacity inside enclosure under the base frame, IS/IEC 60034-1, ISO 1460, ISO 8528, ISO 3046, ISO 9001 & ISO 13027 conformance standards, Hospital grade silencer inside canopy with rain cap suitably optimized to meet stringent noise limit, Remote Monitoring System compact & robust device for real time DG status & monitoring, 4G compatible for 24 V DC, report & notification - Alerts & warning, Fuel Theft Alarm, Isolated RS 485 interface, Device location using triangulation. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV+) latest norms complete with AMF Panel, Fuel Tank, Batteries & Leads, Silencer - Residentia, AVM Pads, First Fill of Lube Oil and Acoustic Enclosure. PCC foundation as per OEM to be paid under srl item no 79 above all as specified and as directed with the following specifications :- |
| 80 | Item No 79.00 Contd......./-(A) ENGINE - 6 number of Inline Cylinders, Turbo charged and Intercooled Radiator cooled engine , Liquid Cooled (EG Compleat 50:50) cooling suitable for continuous operation generating 63 KVA at 1500 RPM, 415 Volts, 0.8 power factor (lagging) suitable for 50 Hz and compling with performance class of Generator set ISO 8528-5 G2 standard :- (i) Robust and efficient air handling system with Dry type and releaceable paper element air cleaner with restriction indicator and optimized turbocharger for increased altitude capabilities. (ii) 24V electrical starting system consisting of starter motor, charging alternator and 12V, 95AH, 02 Nos cummins pulse value plus battery. (iii) Common rail electronic injection system (CREI) fuel system.. (iv) Electronic type Governor.(iv) Cooling system is designed and tested for 50°C ambient conditions. (v) CK4 type lube oil. (vi) Exhaust pipe size of 6 inch as per site requirement.(vii) Electrical starter motor with soft start engagement feature. (viii) Battery charging alternator |
| 81 | Item No 79.00 Contd......./-(B) ALTERNATOR : HCI444D type alternator frame suitable for continuous operation generating 63 KVA at 1500 RPM, 415 Volts, 0.8 power factor (lagging) suitable for 50 Hz, 3 phase, 4 wire system Brushless type, Screen protected, Revolving field, Self excited alternator. The alternator has the following features : (a) ± 0.1% voltage regulation (max) (b) IP : 23 protection with insulated class H. (c) 40 Deg C Design Ambient Temperature. |
| 82 | Item No 79.00 Contd......./-(C) Controller functions provide :-(i) AMF Functionality (Separate Panel)(ii) Remote start-stop(iii) Modbus interface (RS485 RTU)(iv) Manual Run/ Off / Auto switch(v) Emergency stop(vi) Configurable glow plug control(vii) Theft proof fuel & DEF filling arrangement(viii) Data Logging : Engine hours, Control hours and upto 5 recent fault codes.(ix) Suitable for sync through External Sync controller |
| 83 | Item No 79.00 Contd......./-(D) Engine Protection/ Warning Functions includes :- (i) Low Lube oil pressure warning/ shutdown. (ii) High coolant temp warning/ shutdown. (iii) Low coolant temperature warning. sensor failure indication (iv) Low and High battery voltage warning (v) Weak battery warning (vi) Fail to crank shutdown.(vii) Low fuel level(viii) Cranking lockout : Control will not allow the starter to engage or to crank the running engine (ix) 4-20mA analog input compatible for oil pressure sensor and fuel level.(x) Maintenance due alarm based on Engine Run Time and due date.(xi) Exercisers scheduler.(xii) Overspeed shutdown. |
| 84 | Item No 79.00 Contd......./-(E) Alternator functions includes :-(i) Loss of AC High and Low AC voltage shutdown.(ii) Over current.(iii) High Voltage.(iv) Sleep mode.(v) Low voltage.(vi) Under / Over frequency. |
| 85 | Item No 79.00 Contd......./-(F) TECHNICAL SPECIFICATIONS OF ACOUSTIC ENCLOSURE FOR CBCP IV(i) Factory Fitted integrated -ACOUSTIC ENCLOSURE Silent DG Set Enclosure with Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning.(ii) The enclosure is fabricated out of CRCA sheet of 16 SWG.(iii) Top lifting for easy handling at customer site and Silencer Inside enclosure(iv) Theft proof Fuel & Def filing arrangement(v) Fuel filling arrangement Outside the enclosure(vi) CRAC sheet shall be 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment.(vii) Enclosure is powder coated (inside as well outside) with a special pure polyester based powder. All internal Nuts and bolt are made of MS and all external Nuts and Bolts are made from stainless steel.(viii) The doors are gasketed with high quality EPDM gaskets to avoid leakage of sound.(ix) The door handles are lockable type.(x) Sound proofing of enclosure is done with high quality PU foam confirming to IS 8183 of 40 mm thickness and destiny at 28 kg /M3.(xi) The rock wool is further covered with fibre glass cloth and perforated powder coated MS sheet.(xii) Specially designed attenuators are provided to control sound at air entry to the container and exit from the container.(xiii) Adequate ventilation is provided to meet air requirement for combustion and heat removal.(xiv) Viewing window is fitted with toughened glass instead of acrylic sheet.(xv) As per CPCB norms with acoustic enclosure the noise level shall be 75 dBA at one meter in absence background noise AT 75% load upto 1000 KVA Please Enable Macros to View BoQ information |
| 86 | Item No 79.00 Contd......./-(F) TECHNICAL SPECIFICATIONS OF ACOUSTIC ENCLOSURE FOR CBCP IV(i) Factory Fitted integrated -ACOUSTIC ENCLOSURE Silent DG Set Enclosure with Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning.(ii) The enclosure is fabricated out of CRCA sheet of 16 SWG.(iii) Top lifting for easy handling at customer site and Silencer Inside enclosure(iv) Theft proof Fuel & Def filing arrangement(v) Fuel filling arrangement Outside the enclosure(vi) CRAC sheet shall be 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment.(vii) Enclosure is powder coated (inside as well outside) with a special pure polyester based powder. All internal Nuts and bolt are made of MS and all external Nuts and Bolts are made from stainless steel.(viii) The doors are gasketed with high quality EPDM gaskets to avoid leakage of sound.(ix) The door handles are lockable type.(x) Sound proofing of enclosure is done with high quality PU foam confirming to IS 8183 of 40 mm thickness and destiny at 28 kg /M3.(xi) The rock wool is further covered with fibre glass cloth and perforated powder coated MS sheet.(xii) Specially designed attenuators are provided to control sound at air entry to the container and exit from the container.(xiii) Adequate ventilation is provided to meet air requirement for combustion and heat removal.(xiv) Viewing window is fitted with toughened glass instead of acrylic sheet.(xv) As per CPCB norms with acoustic enclosure the noise level shall be 75 dBA at one meter in absence background noise AT 75% load upto 1000 KVA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender