Tender For Provn Of Single Offrs Accn Near Bldg No P-18 (Offrs Mess) At 57 Weu And Provn Of Toilet And Urinal Block At Depot Area Of 200 Pet Pl Asc Under Ge (North) Udhampur.
Tender Overview
Project Description
Tender for Provn Of Single Offrs Accn Near Bldg No P-18 (Offrs Mess) At 57 Weu And Provn Of Toilet And Urinal Block At Depot Area Of 200 Pet Pl Asc Under Ge (North) Udhampur.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Nov-2026 | Revised BOQ | BOQ | 26-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.5 mtr wide and 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sqm on plan and not exc. 1.5 mtr in depth in any type of soil and getting out all as specified and directed. |
| 3 | Excavation over areas, not exc 1.50m deep and getting out in any type of soil complete all as specifed and directed. |
| 4 | Excavation over areas, exc 1.50m but not exc 3.0m deep and getting out in any type of soil complete all as specifed and directed. |
| 5 | Returning, filling including spreading, levelling and well ramming in layers not exceeding 25 cm in each layer as in any type of soil complete all as specified and directed. |
| 6 | Removing excavated soils not exc 50 mtrs and depositing where directed at a level not exc 1.50 mtr above the starting point, complete all as specified and directed. |
| 7 | M&L brick work with sub class 'B', old size, fly ash brick, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6, complete all as specified and directed. |
| 8 | M&L brick work with sub class 'B' old size, fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed. |
| 9 | M&L for treating the bottom and sides of excavation with ATT emulsion at the rate of 5 litres per Sqm surface area complete all as specified and directed. |
| 10 | M&L for treating the backfilling in contact with foundation with ATT emulsion at the rate of 7.5 litres per Sqm of vertical surface, complete all as specified and directed.NOTE:- Area of the sub-structure in contract with backfill to be measured and paid separetely |
| 11 | M&L for treating the top surface of field earth with ATT emulsion at the rate of 5 litres per Sqm of surface area, complete all as specified and directed. |
| 12 | M&L for treating the soil under plinth protection with ATT emulsion at the rate of 5 litres per sqm of surface area, complete all as specified and directed. |
| 13 | M&L for treating the soil along with external perimeter of building with ATT emulsion at the rate of 2.25 litre per metre of the perimeter wall, complete all as specified and directed. |
| 14 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling, sub base and mass concrete, complete all as specified and directed. |
| 15 | M&L for RCC M-25 (Design mix) using 20mm graded crushed stone aggregate for foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 16 | M&L for RCC M-25 (Design mix) using 20mm graded crushed stone aggregate for in columns, pillars, posts and struts, complete all as speciifed and directed. |
| 17 | M&L for RCC M-25 (Design mix) using 20mm graded crushed stone aggregate for in beams, cantilevers, coloum, lintels over 1.50m span, complete all as specified and directed. |
| 18 | M&L for RCC M-25 (Design mix) using 20mm graded crushed stone aggregate for in chajjas, complete all as specified and directed. |
| 19 | M&L for RCC M-25 (Design mix) using 20mm graded crushed stone aggregate for in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, complete all as specified and directed. |
| 20 | M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in lintels up to 1.50 mtr clean span, cills siesmic and other similar bands, plinth courses, coping, bed plates including weathering slightly rounded or chemfered angles and throating, complete all as specified and directed. |
| 21 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 22 | M&L for mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 23 | Mild steel TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spaces and binders with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 24 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter with rough finished flat surfaces, complete all as specified and directed. |
| 25 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished flat surfaces, complete all as specified and directed. |
| 26 | Use and waste of formwork to sides and soffits of floor or roof beams haunching, lintels, coloum, cantilever shelves including supported over hangs etc. with rough finished flat surfaces of concrete, complete all as specified and directed. |
| 27 | Use and waste of formwork to roofs, chhajjas, trough and similar items including edges with rough finished flat surfaces of concrete, complete all as specified and directed. |
| 28 | Use and waste of formwork to soffits of suspended slabs such as slab floor, slab and similar work not exc. 200mm thick with rough finished flat surfaces, complete all as specified and directed. |
| 29 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide complete all as specifed and directed. |
| 30 | Use and waste of formwork faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. to rough finished vertical or to batter complete all as specified and directed. Please Enable Macros to View BoQ information |
| 31 | Use and waste of formwork faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. to rough finished vertical or to batter complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.