Tender For Repair And Maintenance Of (A) Police Station Building At Koregaon Park For C.P., Pune Dist. Pune (B) Type-Iii Quarters At Gat No. 160 Yerwada Jail For Adl.Dgp (Prison), Maharashtra State, Pune (C) 71 Police Quarters At Akkalkot, Dist. Sola
Tender Overview
Project Description
Tender for Repair And Maintenance Of (A) Police Station Building At Koregaon Park For C.P., Pune Dist. Pune (B) Type-Iii Quarters At Gat No. 160 Yerwada Jail For Adl.Dgp (Prison), Maharashtra State, Pune (C) 71 Police Quarters At Akkalkot, Dist. Solapur For S.P., Solapur (Rural)
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | Providing and applying two coats of flat oil paint of approved colour to the old structural steelwork and ironwork previously painted in building, including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat), etc., compl |
| 3 | Scrapping the old plastered/paint internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. For internal Paint as directed by Engineer-in-Charge. |
| 4 | Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. as directed by Engineer-in-Charge. |
| 5 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. as directed by Engineer-in-Charge. |
| 6 | Removing urinal pans or wash hand basins with frames, including disconnecting the sanitary and water supply connections, carefully removing the same and stacking the serviceable materials as and where directed, including carrying and disposing of unservic |
| 7 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking the flooring and bed concrete around the pan, removing the same carefully and stacking the serviceable materials as and where directed, including t |
| 8 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement m |
| 9 | Providing and laying vitrified mirror/glossy finish tiles of size 590 mm to 605 mm × 590 mm to 605 mm and 8 mm to 10 mm thickness, conforming to IS 15622:2006 (Group Bla), of approved make, shade and pattern, for dado and skirting in required position, fi |
| 10 | Fixing of European type white glazed earthenware coupled closet symphonic trap to the existing sanitary connection, including fixing in position with cement mortar, making good the flooring and bed concrete around the pan, testing for proper functioning |
| 11 | Re-fixing of dismantled urinal pans or wash hand basins with frames, including necessary sanitary and water supply connections, fixing in position, testing for proper functioning and leakage, and making the work complete in all respects as directed.as dir |
| 12 | Removing brick bat coba including stacking the spoils as directed with all leads,lifts etc, complete.as directed by Engineer-in-Charge. |
| 13 | Waterproofing Treatment to new Toilet/bathroom by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20mm mortar finish. If there are cracks on the bare slab, open the crack in V Gr |
| 14 | Waterproofing Treatment to new terrace by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112 mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove a |
| 15 | Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect |
| 16 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.as directed by Engineer-in-Charge. |
| 17 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. Upvc pipe with necessary fittings, remaking good the demolished portion etc. complete.as directed by Engineer-in-Charge. |
| 18 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. Upvc pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as dire |
| 19 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as dire |
| 20 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 21 | Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete.as directed by Engineer-in-Charge. |
| 22 | Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.as directed by Engineer-in-Charge. |
| 23 | Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete.as directed by Engineer-in-Charge. |
| 24 | Providing and fixing 32 mm dia. chromium plated bottle trap to existing wash basin, including dismantling and removing the existing bottle trap, necessary nuts, washers, connections, testing for leakage, and making good the work complete. |
| 25 | Providing and fixing 15 mm diameter PVC Aqua Kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete as directed by Engineer-in-Charge. |
| 26 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete.as directed by Engineer-in-Charge. |
| 27 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including |
| 28 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.as directed by Engineer-in-Charge. |
| 29 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.as directed by Engineer-in-Charge. |
| 30 | Fixing of flush valve to the existing W.C. pan, including necessary water supply connections, fixing in position, testing for proper functioning and leakage, and making the work complete in all respects as directed as directed by Engineer-in-Charge. |
| 31 | Removing doors and windows with frames and stacking thematerials as directed with all leads, lifts etc. complete.as directed by Engineer-in-Charge. |
| 32 | Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups@250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long |
| 33 | Providing and fixing 30 mm thick both side pre-laminated solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size 19 x 19 mm for stiles and 15 x 15 mm for the top and bottom rails. M.S. frame shall have one co |
| 34 | Replacement of damaged Aldrop 300 mm Iron Oxidised of approved quality and make to door shutter, including removing the existing one and fixing the new one in its original position, making proper adjustment for smooth operation etc. complete as per sample |
| 35 | Replacement of damaged Aluminium Handle 125 mm of approved quality and make to door/window shutter, including removing the existing one and fixing the new one in its original position, making proper adjustment for smooth operation etc. complete as per sam |
| 36 | Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. comp |
| 37 | Removing existing translucent multi-cell polycarbonate roofing sheets from the existing roof fabrication/MS structure, including carefully dismantling and removing all existing fixing accessories, screws, connectors, fasteners, etc., stacking the servicea |
| 38 | Providing leak-proof treatment to existing W.C. and bath floors by injection grouting method, without removing the existing tiles, using cement and sand in the proportion of 1:1.5, mixed with waterproofing compound at the rate of 2 kg per bag of cement an |
| 39 | Removing existing deteriorated silicone sealant from joints between aluminium window frame and glass, thoroughly cleaning and preparing the joint surface, and providing and applying approved quality weatherproof silicone sealant of required colour and gra |
| 40 | Providing and fixing Stainless Steel Door Stopper, including necessary screws, fasteners and fixing complete as directed by Engineer-in-Charge. |
| 41 | Providing and fixing European type white glazed earthenware coupled closet with S-trap, including white glazed low-level 10-litre capacity cistern, black Bakelite seat and cover, all necessary pipe connections, fittings, accessories, and making good the w |
| 42 | Providing and fixing oval type under-counter wash hand basin of size 420 x 590 x 195 mm with pillar cock, C.P. angular stop cock, long thread of approved make, continental including S.S. bottle trap and necessary pipe connections up to the outside face of |
| 43 | Providing and fixing white glazed vitreous china urinal of size 710 × 460 × 300 mm with sensotronic concealed type flushing valve for urinal, complete with all necessary fittings, inlet pipe with stop tap, brackets for fixing, 32 mm diameter PVC flush pip |
| 44 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the |
| 45 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.as directed by the Engineer-in-Charge. |
| 46 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.as directed by the Engineer-in-Charge. |
| 47 | Providing pre-constructional anti-termite treatment as per IS 6313 (Part II), by treating the backfill in immediate contact with the foundation at the rate of 5 litres of 1.0% Chlorpyrifos emulsion per square metre of vertical surface area, including a 10 |
| 48 | Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/steel formwork, laying/ pumping, compacting, rougheni |
| 49 | Dismantling brick masonry in lime or cement mortar and stacking them at site as directed with all leads, lifts etc. as directed by the Engineer-in-Charge. |
| 50 | Providing first-class brick masonry with conventional/IS type bricks in cement mortar 1:4, including scaffolding, raking out joints, pointing in C.M. 1:3 and watering, etc., in pillars of curved shapes, as shown on the drawings or as directed by the Engin |
| 51 | Providing and applying two coats of wall care putty of approved make on plastered surfaces, ceilings and walls to prepare the surface smooth, even and suitable for painting, complete as directed by the Engineer-in-Charge. |
| 52 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to oncrete or brick surfaces, in all position including scaffolding and curing etc. complete.as directed by the Engineer-in-Charge. |
| 53 | Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing |
| 54 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old/new surface in two coats including scaffolding, prepare the surface. (excluding primer coat) etc. complete. |
| 55 | Providing and applying two coats of textured synthetic paint of approved shade and quality, including one coat of primer before applying the textured paint, scaffolding wherever necessary, and preparing the surface by thoroughly cleaning oil, grease, dirt |
| 56 | Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 kg/sq.m.). as |
| 57 | NON SSR-Providing and making rebate/recess in existing stone/masonry for fixing of Umbarpatti, including cutting, chiselling, dressing and cleaning the rebate to required size and depth, complete as directed by Engineer-in-Charge. |
| 58 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using app |
| 59 | Providing and fixing of glass in existing aluminium window after removing the damaged/broken glass, including removal of debris, necessary cutting, fixing with approved glazing material/sealant and making good the work including window lock, complete as d |
| 60 | Removal of plants / ficus grown by pulling out root system embedded in masnory,cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide 'Glycel'(iso proplamine sal |
| 61 | Providing and fixing on walls /ceiling/ floor 40mm dia.CPVC pipe with necessary fittings ,remaking good the demolished portionetc.complete.Including removing existing pipeline ifnecessary and conveying and stacking the same in PWD chowky or as |
| 62 | Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking |
| 63 | Providing and fixing solid core flush door shutter in single leaf, 32mm thick, decorative type of exterior grade as per detailed drawings, with approved face veneers 3mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wroug |
| 64 | Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580mm dia, including P.C. strap, cast iron soil and vent pipe up to the outside face of the wall, (1:5:10) cement concrete bedding 15mm thick, 10 litre P.V.C. flushing cistern wi |
| 65 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramm |
| 66 | Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and wate |
| 67 | Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints when plastering is to be done / striking joints when no plastering is to be done on inside watering and sc |
| 68 | Providing and laying Rough Shahabad Stone Flooring 40mOne Metric Tonneo 45 mm. thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. et as |
| 69 | Compacting the subgrade/gravel /size meta l(100mmloose) layers fo rall width swith vibratry roller having weight 8 to10MT. Including necessary, labour, materials and artificial as directed by the Engineer-in-Charge. |
| 70 | Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolli |
| 71 | Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, |
| 72 | Providing and constructing 75 mm. thick Modified Penetration Macadam (MPM) roadsurface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubble obtain |
| 73 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ bindi |
| 74 | Clearing grass and removal of rubbish upto adistance of 50metres outside the periphery of the area . as directed by Engineer in charge . |
| 75 | Painting letters of required height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. |
| 76 | Addition of Royalty charges for Rubble |
| 77 | Addition of Royalty charges for Murrum |
| 78 | Addition of Royalty charges for Sand |
| 79 | Laboratory Testing Charges Cement (Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial & Final), Compressive Strength, Soundness) |
| 80 | Laboratory Testing Charges Aggregate (Water Absorption, Specific Gravity, lmpact Value Crushing Value.) |
| 81 | Laboratory Testing Charges Cement Concrete (Compression strength |
| 82 | Laboratory Testing Charges Sand/Fine Aggregate (a) Fineness Modulus strength |
| 83 | Laboratory Testing Charges Sand/Fine Aggregate (b) Silt Content |
| 84 | Laboratory Testing Charges Hard murum filling (a) Compaction Test (Proctor Density) |
| 85 | Laboratory Testing Charges Hard murum filling (b) Liquid Limit and Plastic Limit |
| 86 | Laboratory Testing Charges Ceramic Tiles/Vitified Tiles (Water absorption, Modulus of Rupture (Set of 6 Tiles)) |
| 87 | ELECTRICAL INSTALLATION |
| 88 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 89 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 90 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 91 | Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 92 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 93 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 94 | Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 95 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 96 | Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 97 | Supplying & erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole /Bus bars or any other places as per specification No: WG-MA/BW |
| 98 | Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW |
| 99 | Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW |
| 100 | Supplying & erecting mains with 1x10sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW |
| 101 | Supplying & erecting mains with4x16sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW |
| 102 | Supplying & erecting mains with4x16sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (Main PDB Circuit earth) |
| 103 | Supplying & erecting mains with4x25sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW |
| 104 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 105 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 106 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 107 | Supplying and erecting 16/20/25 A staeter (moodular range) 2 module for AC unit on provided plate and box complete & duly conceald with necessary material and connected. |
| 108 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 109 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box |
| 110 | Supplying and erecting modular type blanking plate two module, duly erected on provided plate & box |
| 111 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. |
| 112 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 113 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. |
| 114 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 115 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 116 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripp |
| 117 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., R |
| 118 | Supplying and erecting rectangular shaped LED panel Light (1200mm X300mm) Max 35W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 4200 Lumens, min effcacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of |
| 119 | Supplying and erecting electronic type driver for indoor LED 19W-24W fixtures suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 120 | Supplying and erecting electronic type driver for indoor LED 25W-40W fixtures suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 121 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/con |
| 122 | Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 123 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG6 as per specification No. WG |
| 124 | Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 125 | Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW (main cable) |
| 126 | |Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 127 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 128 | Rewinding the motor of the Exhaust fan 900 / 1400 RPM 300 mm of alltypes, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with |
| 129 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. complete with 5 years warranty. |
| 130 | Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guar |
| 131 | Supplying and erecting condenser 2.5 micro farad for ceiling fan |
| 132 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/ compatible speed regulator, Temperature Rise of Max. 40 de |
| 133 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 134 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 135 | Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification n |
| 136 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 137 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. |
| 138 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC (in each quarter Hall Wifi Point) |
| 139 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC |
| 140 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 141 | Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, |
| 142 | Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 143 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 144 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 145 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 146 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification |
| 147 | Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no S |
| 148 | Supplying & erecting 415V, 16A porcelain base neutral link complete erected in provided M.S. box. |
| 149 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per spe |
| 150 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per spec |
| 151 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per spec |
| 152 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per spec |
| 153 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per spec |
| 154 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per spec |
| 155 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete, (for all street Light pole cable pro |
| 156 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 157 | Supplying & erecting FRP box of size 250mm X 200mm X 100mm, 2.7mm thick complete on pole/wall as per specification on CB-SB |
| 158 | Supplying & erecting FRP box of size 300mm X 200mm X 125mm, 2.7mm thick complete on pole/wall as per specification on CB-SB |
| 159 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill gr |
| 160 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 161 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, |
| 162 | Supplying and erecting electronic type Driver for Outdoor LED Fittings upto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 163 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 164 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. |
| 165 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lug |
| 166 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hard |
| 167 | Supplying and erecting & terminating FRXLPE insulated galvanised steel formed wire armoured (strip) cable 1100V, 31/2 core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall trusses/pole or laid in provided trench CB-LT/AL(2Run f |
| 168 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. |
| 169 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 170 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 171 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 172 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 173 | Supplying & erecting automatic control panel for 3 Phase, 415 volt, A.C, Submersible/ centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA pow |
| 174 | Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. (for all Pump) |
| 175 | Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only (FOR EACH PUMP) |
| 176 | Rewinding of electric motor above 2 H.P. upto 3 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed |
| 177 | Rewinding of electric motor above 3 H.P. upto 5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed |
| 178 | DG WORK :-Providing Fully Comprehensive Annual Maintenance for 25 KVA Silent D.G.set . |
| 179 | SCOPE OF WORK :-1) Servicing of each DG set at least once in month and as & when required with no extra charge. 2)To attend all the break down calls with Replacement of batteries as and when required 3) To maintain the log book of each servicing & repairing of each DG set 4)Inspecting engine & carrying minor adjustment repairs as per necessary. 5)Checking tappet clearance if necessary 6) Checking lubricant oil condition & replacing as & when required. 7) Checking lubricant oil filters 8) Checking & cleaning pre-cleaner assembly lubricant oil filters 9)Checking bolt alignment & bolt tension as per requirement & resetting time to time 10)Checking generator coupling 11) Checking radiator water level & cleaning as per requirement. 12)Checking and inspecting of battery's & its waterlevel, add distilled water if necessary, check and maintain record of specific gravity by Hygrometer. 13) Checking battery terminals & battery charger.14)Checking alternator carbon brushes & its tension & adjusting as per requirement including replacement or carbon brushes. 15)Checking automatic main failure panel & its connection as per requirement, carrying out minor adjustment including replacement of contactors, replays, bush indicators, panel wiring etc. 16)Servicing of each DG set in One months = 1 Job 17) Penalty - Un-Attendance of breakdown or rectification of fault within the specified time limit or Unattendance for standby duty/Inspections will attract the penalty of Rs.500/- per day per event Note- The contractor should arrange the minimum required diesel at their own expense during the maintenance period. |
| 180 | FIRE FIGHTING :Providing fully comprehensive annual maintenance for Fire fighting and fire alarm system installed in Police station premises monthly visits & six-monthly training schedules and submission of form B must be provided by contractor/ agency |
| 181 | Scope of work:Fire PumpBooster Pump: -• Servicing, overhauling, checking and testing of pump• Operating the pumps in auto/manual mode and checking the system. Checking the setting of the pressure switches and all the pumps by operating. External Pipe Lines (Including all risers)Servicing, checking, Risers greasing and painting if required attending minor leakages, testing, commissioning both systems.Hydrant System Checking including RRL hose pipe, hose reel drum, jet shut off Nozzle, branch pipe nozzle, cabinet door servicing, cleaning, painting. Checking of hydrant valves washers and lug lock.Changing of gasket/ nut bolts if required Way Inlet Connections (Fire Brigade Connection) Servicing, checking, greasing and painting. Re-tighten any loose bolts and nuts in proper sequenceAnnual report based on quarterly report with counter signature of agency’s responsible person and necessary submission of the same to local fire authority including licensing with fire authority. Demonstration of fire fighting system quarterly. Monthly visit and maintenance of pumps, pipelines, valves, servicing of water pumpsets with minor repairs/replacement of minor parts like nutbolts, gland packing, overhauling, greasing, belts, repairs of switchgears, rewinding of all kind of fire pumps, sprinkler pumps and jocky/booster pumps etc. starters, panels etc as per engineer-in -charge instructions.b. during every monthly visit providing Certificate B after testing of system.c. Quarterly visits during AMC period and carry out the required preventive maintenance. d.Checking & Cleaning all extinguishers with tags and painting if necessary.e. Checking & Servicing all hydrants, valves & pumps etc.f. Checking pressure in the hydrant & sprinkler networks.g.Checking the piping for any leakages in case of high drop in pressure.h. attending the calls / complaints within 2 hrs and resolving within 24 Hrs.i. Providing technician during VVIP visit and in emergency.j. Preparing the log book/ Service Report entry in register of day to day maintenance after every visit. Fire Alarm System: - • check the Fire Alarm control panels & ensure for normal operation• Check the power supply positions in respect of all panels.• Check the building LED indications on panels• Check any fault if indicated on any of the panels are rectify the same immediately• monthly checks & Servicing• Monthly cleaning of all the servicing cleaning of Panels along with accessories etc., in the FA system or as & when required least Once in a month.• checking Fire circuit of each zone from the panels• checking Performance of the manual caIl points• Monthly visual Testing of indications on detectors, Mcp isolator etcComplete Cleaning, servicing of fire hydrant panel every six months z. servicing and refilling of Co2 type portable fire extinguishers of 4.5 Kg and ABC type portable fire extinguishers of 6 Kg including the following works and maintenance activities as per IS: 2190 and standard fire safety guidelines:Every six month inspection and maintenance of each extinguisher, including visual checking of physical condition, pressure gauge indication, safety pin, hose, nozzle, and label condition, Cleaning and checking of extinguisher body, discharge pipe, and nozzle for blockages, corrosion, or damage Verification of pressure level, Replacement of defective parts such as pressure gauge, safety clip, discharge hose, or nozzle with new ISI marked components where necessary. Once in three year Hydraulic testing, repainting and labeling of the extinguisher body with approved paint and stickers showing type, capacity, and date of refilling and refilling with with pressurized carbon dioxide (CO2) gas of required quantity and quality and submission of Hydraulic test certificate & Demonstration and minor training to the concerned staff on proper usage and first-level inspection.All work to be completed as per manufacturer's recommendations, safety norms and to the satisfaction of the Engineer-in-Charge Penalty - non-attendance of breakdown or rectification of fault within the specified time limit or non-attendance for standby duty/Inspections will attract the penalty of Rs.500/- per day per event Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender