Rural Development Government Departments Closing in 0 days TDR #58397727

Tender For Retrofiting To Piped Water Supply Scheme At Shivnakwadi, Tal- Shirol Dist- Kolhapur.

Issued by Government Departments · Kolhapur, Maharashtra
Tender Value
2.19 Crore
Estimated cost
Bid Submission
19 Nov 2026
0 days left
EMD
2.19 Lakhs
Bank guarantee accepted
Document Fee
41900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolhapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Retrofiting To Piped Water Supply Scheme At Shivnakwadi, Tal- Shirol Dist- Kolhapur.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Nov-2026 Corrigendum- DATE EXTEND Date 16-Nov-2026
2 16-Nov-2026 Corrigendum- DATE EXTEND 3 DAYS Date 19-Nov-2026

BOQ

Name of Work:- RETROFITING TO PIPED WATER SUPPLY SCHEME AT SHIVNAKWADI, TAL- SHIROL DIST- KOLHAPUR.
Sl. No. Item Description
1Sub Work No. 1 - Injection Well Empty boring for 525 to 600 mm dia. Bored R.C.C. Cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete.Spec :(As directed by Engineer in Charge)
2Providing and supplying ISI standard MS specials of required thickness with 3 coats of approved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excluding all statutory duties & taxes such as GST levied by GOI & GOM in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete. e) Plain ended specials or plain ended branch flanged specials of all diameters.
3Providing and fixing screw down for 25mm dia. Wheeled stop tap of brass including necessary sockets / union nut complete.
4Filling in plinth and floors / trenches with contractor's murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete.
5Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with necessary jointing material like mechanical connector i. e. thread /insert joint / quick release coupler joint /compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. A.) PE-100 a) 6 Kg/Sq. cm : 160mm dia
6Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II A.) PE-100 a) 6 Kg/Sq. cm : 160mm dia
7Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
8Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Dia 150 mm without bypass
9Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete. (Rate for all class of valves.) Dia 150 mm without bypass
10Sub Work No.02 - Raw water Pumping Machinery 20HP Providing erecting and giving test of 150 mm dia. Submersible vertical Pump sets conforming to IS 8034/76 and motor conforming to IS9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and Bronze impeller. Motor suitable for working on 415 V+10%, 3Ph,50 Hz., A.C. supply with Cable guard, water lubricated bearings to entire hydraulic thrust, waterproof winding shall be provided. The pump set shall be suitable for direct coupled to the motor Pump shall have suitable outlet as per manufactures design. Suitable suction strainer shall also be provided, 3 core, single/double run copper conductor submersible type flat cable 3m shall be provided along with the pump HEAD= 75 M DISCHARGE =561.12 LPM 20 HP
11Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc.completeasperIS-1239/2004. 80mm dia. B. Class Pipes
12Lowering laying and jointing G.I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge. 80mm dia. B. Class Pipes
13Providing, supplying and erecting M.S. pipes and specials as per requirement and flanges, rubber packing, nut bolts including painting but excluding supports (while measuring weight of pipe and special only shall be considered. ) Double flanged specials
14Suppying & erecting flat flexible 3 core 6 sqmm PVC sheathed submersiable type copper cable suitably clampped at fixed intervals with column pipe assembly complete.
15Supplying and erecting panel board this includes following items.(1) Triple pole switch, (2) water level guard,(3) Voltmeter,(4) Amperemeter,(5)Sets of pilot lamp,(6) Starter DOL/Star Delta,(7) Capacitor,(8) Sector Switch,(9) Earth Leakage Circuit Breaker(ELCB),(10)M.S. Sheet Box,(11)T.W. planks,(12)Iron panel board, (13) G.I. sheet caution board,(14) self lock etc.complete.
16Supplying and erecting Galvanized cast iron earth plate size 60X60X0.60 cm complete with all materilals, testing and recording the results as per specification No.EA-EP
17Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT
18Providing, supplying and erecting triple super type chain pully block suitable for capacity 1.00 MT with 6.00M lift complete with load chain & hand chain ,tested to 50 % load as per I.S.3832 carring ISI mark
19Providing, erecting Travelling Trolley of capacity as below with 6 m lift, tested to 50% over load 1 Tonne Capacity
20Sub Work No.03 - Switch House Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite /gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) PCC-150
21Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim bored pile of 380 mm dia. each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock,excluding provision of reinforcement including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by tremie arrangement compaction of concrete including chipping and dressing etc. complete. (Excluding steel reinforcement) FOR PILE 380mm
22Providing and laying Cast in situ /Ready Mix cement concrete M-25 of trap metal for R.C.C. pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/pumping, compacting, finishing and curingetc. with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.with Crushed sand VSI Grade/V.S.I. quality Artificial Sand, complete. (Excluding steel reinforcement
23Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S.or Tor reinforcement) 1) Column M200
242) Beam & Lintels M200
253) Slab M200
264) Chajja M200
27Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F- 17/306)
28Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering andscaffolding etc. Complete.
29Providing and fixing in position. (as per I.S.1868/1982)Aluminium sliding window of two tracks with rectangular pipe having over all dimension 63.50x38.10x1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85x31.75x1.20 mm at weight 0.695Kilogram/Running metre. Top and side track section 61.85x31.75x1.30mm at weight 0.659 Kilogram/Runningmetre.The shutter should be of bearing bottom 40x18x1.25mm at weight 0.417Kilogram/Runningmetre. Inter locking section 40x18x1.10mm at weight 0.469 Kilogram / Running metre. And handle section 40x18x1.25 mm at weight 0.417 Kilogram / Running metre. and top section 40 x 18x1.25 mm at weight 0.417 Kilogram / Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing inylon casting and selflocking catch fitted invertical section of shutter in cluding 5 mm thick plaingl as swith all required screwsand nuts etc, complete. With colour Anodising with box.
30Providing and fixing steel frame door of angle 50 x 50 x 6 mm with mild steel bars 16 mm dia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixing shutters including welding, finishing,painting etc. complete.
31Providing and fixing M.S. door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
32Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete.
33Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
34Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
35Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including leaning, preparing the plaster surface, applying primercoat, scaffolding if necessary, and watering the surface for two days etc complete.
36Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete.
37Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (groupDII-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete.
38Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding, anchoring and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.
39Sub Work No.04 - Raw Water Rising Main Excavation for pipe trenches in earth, soils of all types, sand, gravel and soft murum including removing the excavated the excavated material upto a distance of 50m. and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding etc. complete.
40Excavation for pipe trenches in hard murum in, W. B. M. road including removing the excavated material upto a distance of 50m. and lifts as below stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling etc complete.
41Excavation for pipe trenches in soft rock and old cement and time masonry foundation as directed. Normal dewatering, preparing the bed for foundation and excluding backfilling etc. compete
42Excavation for pipe trenches in hard rock and concrete road by mechanical means all by any other means other than blasting including trimming and leveling the bed, removing the excavated material upto a distance of 50 m. beyond the area and lifts as below; stacking as directed, normal dewatering, excluding backfilling etc. complete.
43Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete.
44Providing and supplying in standard lengths ISI mark rigid unplastised PVC for potable water with rubber ring joints including cost of rubber ring as per IS-4985-1998, excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, transit insurance, inspection charges, loading, unloading, conveyance to store and stacking the same in closed shed duly protected from sun rays and rains, etc. complete. 160 mm 10 KG/SQCM PVC Pipe
45Lowering, laying and jointing with P.V.C. pipes and specials of following class anddiameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 160 mm 10 KG/SQCM PVC Pipe
46Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. (50mm dia.)Single Acting Air Valve type PN-1
47Lowering laying and fixing in porper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance rom stores to the site of work cost of all material and giving satisfactory hydraulic testing etc complete (for all class of valves) (50mm dia.)Single Acting Air Valve type PN-1
48Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 150 mm dia. NR Valve
49Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete 150 mm dia. Sluice Valve
50Lowering laying and jointing in position following CI D/F reflex valve,butterfly valves and sluice valves including cost of all labour jointing material,including nut bolts and giving satisfactory hydraulic testing etc complete. A) 150 mm dia. Sluice Valve
51B) 150 mm dia. NR Valve
52Providing and supplying C.I. D/F angle type spring loaded pressure relief valves of approved make and quality including inspection charges, transportation to departmental stores excluding GST levied by GOI & GOM in all respect etc. complete. A) 80 mm dia.PRV
53Lowering laying and fixing in proper alignment and osition all types of CI D/F angle type spring loaded pressure relief valves including cost of all material ,labour,cosst of convayance from stores to site of A) 80 mm dia.PRV
54Providing and constructing B.B. masonry valve chamber with 15 cm. thick 1:3:6 proportional PCC bedding, excluding excavation, B.B. masonry in C.M. 1:5 proportion 12mm. thick cement plaster in C.M. 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion, 15 cm. thick slab etc. complete as directed by engineer in-charge. size 0.60X0.45X0.90 m.
55Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15cm.layers with all leads and lifts including consolidation ,surcharging etc.complete.
56Providing and fixing in position air valve shaft including providing and fixing GI MediumClass or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee,providing PCC block of M-150 concrete, 150 mm thick around the air valve tee includingencasing of vertical shaft in PCC M-150 as shown in type design together with providingand making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -incharge for following diameters of pipe lines (type design attached.)
57Providing & Supply of PVC pipe specialsfor all class pipes. 160mm Tee 10 kg/Cm2
58160mm Bend 10 kg/Cm2
59160mm Coupler 10 kg/Cm2
60PVC Tail Piece
61Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.
62Sub Work No.05 - Construction Of Unconventional Water Treatment Plant 'Designing (aesthetically), providing and constructing high rate Unconventional Water Treatment Plant i.e. Simplified Water Treatment Plants consisting of Civil Works, including cost of providing and applying Epoxy paint to inside surface of water retaining structures in contact with Chlorine and providing anti-termite treatment to entire structure below ground level, Mechanical and Electrical components of variours sub works as given below : including necessary hydraulic testing, structural testing and trial run for 3 months, etc. complete as directed by Engineer-in-charge .(turn-key job ).1) Aeration fountain, 2) Inlet arrangements, 3) Mixing channel with ventury flume and flow measuring arrangement. 4) Inlet channel, 5) Flocculator- Confirming to I.S. 7208-1974 ( Type C ) with detention period of 30 minutes. 6) Tube Settlers - \\" Designing, fabricating and construct Tube Settlers with square or any other shaped tube like Circular, Cheveron, Hexagonal etc. having proven performance.\\" 7) Rapid sand gravity filters.- Rapid sand gravity filters including head stock arrangement with solid extension spindle for valves suitable / compatible for mounting actuators. '8) Filter house, 9) Chemical house, 10) Alum tanks 2 Nos. with mixing, carrying and, 11) Gravity feed gas chlorinator with 100% standby. 12) TCL solution tank with mixing, carrying and , 13) Bye-pass arrangement, 14) External and internal electrification, 15) Laboratory equipments, 16) Wash water tanks of capacity equal to 2% of , 17) Wash water pumps with 100%standby, 18) Pure water sump capacity equal to 1 hour pumping capacity, 19) Pure water pump house over the sump / by the side of sump, 20) Drainage arrangements, 21) Alum store, 22) Sanitary block with necessary water supply and drainage arrangement and internal WBM roads, 23) These rates are applicable for seismic zones 2, 3, and 4, 24) Rates given below are inclusive of uplift pressure if any and dewatering during the entire work, 25) All RCC structures shall be constructed in M-300, 26) Unconventional Treatement Plants less than 1 MLD capacity shall not be constructed, 27) Air blowers capable of delivering 600 LMP per square metre of free air of filter area at 0.4 Kg/ sqcm at the under drains (100% standby). Unconventional Treatement Plants upto 3 MLD capacity Blower shall not included however capacity above 3 MLD Blower shall be included. '28) Unconventional Treatement Plants upto 5 MLD capacity 100 Kg. chlorine cylinder shall be provided and capacity above 5 MLD chlorine 900 kg tonner shall be provided. 29) All valves required in WTP shall be glandless instead of traditional valve. 30) All railings required for WTP shall be stainless steel Pipe railing instead of G.I.Pipe railing. 31) External painting for WTP shall be in acrylic emulsion with silicon additives paint instead of waterproof cement paint. 32) Internal flooring for WTP shall be in Ceramic tiles instead of Mosaic tiles.. 33) \\" All the structural steel works /fabrications are to be provided with application of Hot Dip Zinc coating according to specificationa as per IS 4759:1996 ( Reaffirmes 2006) 34) Tha base slab of Back wash water tank and Top slab of Chemical house or Admin building should be separate.Common slab for wash water tank and Admin building is not allowed. 35) The cost of Chlorine contact tank (CCT ) is in included in these rate.Note:- Conditions from Sr.No. 1 to 35 shall form a part and parcel of the tender and must be included in draft tender papaers for the work of unconventional treatment plants.
63Sub Work No.06 - Pure Water Pumping Machinery 7.5 HP Providing erecting and giving test of 150 mm dia. Submersible vertical Pump sets conforming to IS 8034/76 and motor conforming to IS9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and Bronze impeller.Motor suitable for working on 415 V+10%, 3Ph,50 Hz., A.C. supply with Cable guard, water lubricated bearings to entire hydraulic thrust, waterproof winding shall be provided. The pump set shall be suitable for direct coupled to the motor Pump shall have suitable outlet as per manufactures design. Suitable suction strainer shall also be provided, 3 core, single/double run copper conductor submersible type flat cable 3m shall be provided along with the pump. HEAD=25 M DISCHARGE =561.12 LPM, 7.5 HP
64Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc.completeasperIS-1239/2004. 80mm dia. B. Class Pipes
65150mm dia. B. Class Pipes
66Lowering laying and jointing G.I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge. 80mm dia. B. Class Pipes
67150mm dia. B. Class Pipes
68Providing, supplying and erecting M.S. pipes and specials as per requirement and flanges, rubber packing, nut bolts including painting but excluding supports (while measuring weight of pipe and special only shall be considered. ) Double flanged specials
69Suppying & erecting flat flexible 3 core 2.5 sqmm PVC sheathed submersiable type copper cable suitably clampped at fixed intervals with column pipe assembly complete.
70Supplying and erecting panel board this includes following items.(1) Triple pole switch, (2) water level guard,(3) Voltmeter,(4) Amperemeter,(5)Sets of pilot lamp,(6) Starter DOL/Star Delta,(7) Capacitor,(8) Sector, Switch,(9) Earth Leakage Circuit Breaker(ELCB),(10)M.S. Sheet Box,(11)T.W. planks,(12)Iron panel board, (13) G.I. sheet caution board,(14) self lock etc.complete. (Rates are as R.A)
71Supplying and erecting Galvanized cast iron earth plate size 60X60X0.60 cm complete with all materilals, testing and recording the results as per specification No.EA-EP
72Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT
73Providing, supplying and erecting triple super type chain pully block suitable for capacity 1.00 MT with 6.00M lift complete with load chain & hand chain ,tested to 50 % load as per I.S.3832 carring ISI mark
74Sub Work No.07 - Pure Water Rising Main Excavation for pipe trenches in earth, soils of all types, sand, gravel and soft murum including removing the excavated the excavated material upto a distance of 50m. and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding etc. complete.
75Excavation for pipe trenches in hard murum in, W. B. M. road including removing the excavated material upto a distance of 50m. and lifts as below stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling etc complete.
76Excavation for pipe trenches in soft rock and old cement and time masonry foundation as directed. Normal dewatering, preparing the bed for foundation and excluding backfilling etc. compete
77Excavation for pipe trenches in hard rock and concrete road by mechanical means all by any other means other than blasting including trimming and leveling the bed, removing the excavated material upto a distance of 50 m. beyond the area and lifts as below; stacking as directed, normal dewatering, excluding backfilling etc. complete.
78Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete.
79Providing and supplying in standard lengths ISI mark rigid unplastised PVC for potable water with rubber ring joints including cost of rubber ring as per IS-4985-1998, excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, transit insurance, inspection charges, loading, unloading, conveyance to store and stacking the same in closed shed duly protected from sun rays and rains, etc. complete. 160 mm 6KG/SQCM PVC Pipe
80Lowering, laying and jointing with P.V.C. pipes and specials of following class anddiameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 160 mm6 KG/SQCM PVC Pipe
81Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. (50mm dia.)Single Acting Air Valve type PN-1
82Lowering laying and fixing in porper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance rom stores to the site of work cost of all material and giving satisfactory hydraulic testing etc complete (for all class of valves) (50mm dia.)Single Acting Air Valve type PN-1
83Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 150 mm dia. NR Valve
84Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 150 mm dia. Sluice Valve
85Lowering laying and jointing in position following CI D/F reflex valve,butterfly valves and sluice valves including cost of all labour jointing material,including nut bolts and giving satisfactory hydraulic testing etc complete. 150 mm dia. NR Valve
86150 mm dia. Sluice Valve
87Providing and supplying C.I. D/F angle type spring loaded pressure relief valves of approved make and quality including inspection charges, transportation to departmental stores excluding GST levied by GOI & GOM in all respect etc. complete. 80 mm dia. P.R.V TYPE PN-1
88Lowering laying and fixing in proper alignment and osition all types of CI D/F angle type spring loaded pressure relief valves including cost of all material ,labour,cosst of convayance from stores to site of , 80 mm dia. P.R.V TYPE PN-1
89Providing and constructing B.B. masonry valve chamber with 15 cm. thick 1:3:6 proportional PCC bedding, excluding excavation, B.B. masonry in C.M. 1:5 proportion 12mm. thick cement plaster in C.M. 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion, 15 cm. thick slab etc. complete as directed by engineer in-charge. size 0.60X0.45X0.90 m.
90Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15cm.layers with all leads and lifts including consolidation ,surcharging etc.complete.
91Providing and fixing in position air valve shaft including providing and fixing GI MediumClass or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee,providing PCC block of M-150 concrete, 150 mm thick around the air valve tee includingencasing of vertical shaft in PCC M-150 as shown in type design together with providingand making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -incharge for following diameters of pipe lines (type design attached.)
92Providing & Supply of PVC pipe specialsfor all class pipes. 160mm Tee 6 kg/Cm2
93160mm Elbow 6 kg/Cm2
94160mm Coupler 6 kg/Cm2
95160mm PVC Tail Piece without flange 6 Kg/Cm
96Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 160 mm6 KG/SQCM PVC
97Subwork No.08 - Distribution System Excavation for pipe trenches in earth, soils of all types, sand, gravel and soft murum including removing the excavated the excavated material upto a distance of 50m. and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding etc. complete.
98Excavation for pipe trenches in hard murum in, W. B. M. road including removing the excavated material upto a distance of 50m. and lifts as below stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling etc complete.
99Excavation for pipe trenches in soft rock and old cement and time masonry foundation as directed. Normal dewatering, preparing the bed for foundation and excluding backfilling etc. compete
100Excavation for pipe trenches in hard rock and concrete road by mechanical means all by any other means other than blasting including trimming and leveling the bed, removing the excavated material upto a distance of 50 m. beyond the area and lifts as below; stacking as directed, normal dewatering, excluding backfilling etc. complete.
101Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete.
102Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 90mm dia. 4kg./sqcm.
103110mm dia. 4kg./sqcm.
104140mm dia. 4kg./sqcm.
105160mm dia. 4kg./sqcm.
106Providing double flange sluice valve confirmingfor IS-14846 includingworngear arrangementsasper testpressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied byGOI &GOM in all respect etc. complete. A) 80mm dia. Sluice Valve
107B) 100 mm dia. Sluice Valve
108C)150mm dia. Sluice Valve
109Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 90mm dia. 4kg./sqcm.
110110mm dia. 4kg./sqcm.
111140mm dia. 4kg./sqcm.
112160mm dia. 4kg./sqcm.
113Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) A) 80mm dia. Sluice Valve
114B) 100 mm dia. Sluice Valve
115C)150mm dia. Sluice Valve
116Providing ISI standard 2 R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 150 mm dia. RCC Pipe
117200 mm dia. RCC Pipe
118Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar jointsin C.M.1:1 proportion or socketed R.C.C. pipeswith rubber joints (excluding cost of rubber ring or R.C.C. collar,) Including cost of conveyance from storesto siteo f work, cost of jointingmaterial, labour, etc. complete as directed by Engineerin-charge(Forallclassofpipes.)asperIS-783-1985. 150mm dia. RCC Pipe NP-II
119200mm dia. RCC Pipe NP-II
120Providing and fixing CI road boxes of following class and size including loading, unloading and carting to site of work including all necessary excavation in all type of strata and fixing in murum, packing etc complete. 100 mm x 225 mm (20 Kg)
121Providing and constructing B.B. masonry valve chamber with 15 cm. thick 1:3:6 proportional PCC bedding, excluding excavation, B.B. masonry in C.M. 1:5 proportion 12mm. thick cement plaster in C.M. 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion, 15 cm. thick slab etc. complete as directed by engineer in-charge. size 0.60X0.45X0.90 m.
122Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15cm.layers with all leads and lifts including consolidation, surcharging etc.complete.
123Reinstating the asphalt road with providing & laying 60 mm,40mm Over size, size metal, of 0.30m thick layer, hard murum for formation of foundation with proper spreading, watering, compaction with power roller.and 75 mm. thick Modified Penetraction Macadam (MPM) with open graded pre mix surfacing 20mm thk.composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder,and Seal coat over MPM layer sealing the voids in a bituminous surface laid using 60/70 bulk ,bitumen with all material & labour charges ete complete.
124Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264)
125Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) PCC M-150
126Pushing of M.S. pipes of following dia for road crossing and railway crossing by push through method in all types of strata by using hydraulic jack and drilling machine of required diameter of below M.S. casing pipes, lowering, laying , jointing of material, required welding machinery, tripod, shain -pulley block crain, blower, compressor, loading and unloading of machinery into the trench, etc. transportation and dewatering, etc complete, as directed by engineer-incharge but excluding the cost of M.S. pipes. 200 mm to 499 mm dia MS pipe
127Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to requried size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking excluding GST levied by GOI & GOM in all respect, etc, complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). Dia of Pipe : 200 mm (I. D.) 6 mm
128Providing and fixing road junction/ information sign boards of size 1.80 x 1.20 Meter Prepared 16 guage M.S.sheet on frame of size 40x40x5 mm with cross bracing of size 35x35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65 x 6 mm of 3.65 m. long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in- charge etc. complete. Mild Steel Board with Engineering Grade.
129Providing & Supply of PVC pipe specials for all class pipes. Couplers 4kg/cm2 160
130Elbow 4kg/cm2 160
131end cap 160
132Tee 4kg/cm2 160
133Couplers 4kg/cm2 140
134Elbow 4kg/cm2 140
135end cap 140
136Tee 4kg/cm2 140
137Couplers 4kg/cm2 110
138Elbow 4kg/cm2 110
139end cap 110
140Tee 4kg/cm2 110
141Couplers 4kg/cm2 90
142Elbow 4kg/cm2 90
143end cap 90
144Tee 4kg/cm2 90
145Reducer 90x110
146Reducer 140x110
147Reducer 160x140
148Hydraulic testing of PVC pipe to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. A) 90 mm dia.4Kg/sqcm PVC pipe
149B) 110 mm dia.4Kg/sqcm PVC pipe
150C) 140 mm dia.4Kg/sqcm PVC pipe
151D) 160 mm dia.4Kg/sqcm PVC pipe
152Sub Work No-9 :- Structural work for solar system Excavation for pipe trenches in earth, soils of all types, sand, gravel and soft murum including removing the excavated the excavated material upto a distance of 50m. and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding etc. complete.
153Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) PCC M-150
154Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) footing RCC M20
155Providing and casting in situ Cement Concrete of trap/ granite / quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) column M20
156Providing and fixing in position Tor steel bar reinforcement of various diameters for RCC piles, caps, footing, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardies, copings, fins, arches etc as per detailed design and drawing and schedules including cutting bending the bars binding with wires and supporting as required etc complete (including cost of binding wire)
157Providing and fixing in position M .S. ladder 0.50 m. wide consisting of 75 X 10 mm .M .S. flats as stringers and 16 mm. dia. M .S. bars in double rows as steps placed at 25 cm c/c. including cost of material and labor involved, welding, anchoring and applying 3 coats of anti-corrosive paint , etc .
158Providing structural steel work in rolled section like joistes, channels, angles, tees, etc. as per detailed design & drwaing including fixing in position without connecting plates braches etc. and one coat of anticorrosiv paint and overit two coats of oil painting as approved quality and shade etc. complete
159Providing & fixing M.S. chaqerred plate florring of 6mm thick supported on M.S. angles (25x25x5 mm size) including welding, cuting & fabricating the plate to required square or rounding shape, making holes in the plate including, providing & applying three coates anticorrosive paints etc. complete. As directed by Engineer-in-charge. 6mm thk
160Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick M.S. angles as verticals at 1.5 M c/c and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal and painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shade including cost of all labour, transporting bends to curved shape, etc. complete.
161Sub Work No. 10 - Solar System 11KW @ WTP Supplying, installing, testing and commissioning of 11 kWp ON-GRID Solar PV System / Plant consisting solar PV poly crystalline panel (335 Wp X 09 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS system, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully (PWD SSR 22-23, P/I 78/5-4-1)
162Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months istory of energy, load survey,TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.(PWD Ele-DSR 2022-23 P.No. 111 Item No. 6-3-14 )+5%
163Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.(PWD Ele-DSR 2022-23 P.No. 110 Item No. 6-3-5 ) +5%
164Supplying, erecting & terminating XLPE armoured cable 3 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (PWD Ele-DSR 2022-23 P.No. 129 Item No. 7-2-17 )+5%
165Subwork No 11 - Trial Run. Commissioning, running and maintaining the scheme to quantities, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and for regional scheme, together with training of personnel spared by MJP / Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58397727
AUTHORITY Government Departments
TENDER VALUE 2.19 Crore
LAST DATE 19-11-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Retrofiting To Piped Water Supply Scheme At Shivnakwadi, Tal- Shirol Dist- Kolhapur.
Basic Detail
Tender No 06/2026-27
Bidding Type Tender
Location
City Kolhapur
State Maharashtra
Key Dates
Publish Date 16 Nov 2026
Submission Date 19 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 2.19 Crore
Tender Fee 41900
EMD 2.19 Lakhs
Exemption Not Available
Document List
2260a079-804c-459c-b045-429008b57a70.html
BOQ_2306750.xls
NIT.pdf
PQ.pdf
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 19, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
html

2260a079-804c-459c-b045-429008b57a70.html

xls

BOQ_2306750.xls

pdf

NIT.pdf

pdf

PQ.pdf

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender