Bids Are invited for Data Centre Infra And Managed O& ;M Services At C-Dot, Bangalore - Rmu/Vcb At Main Feed [Outdoor Rmu - Two-Way Outdoor Sf6 11Kv] , 11 Kv Ht Cable , Transformer , Ht Panels , Main Lt Panel , Dg Sets - Prime Rated , Dg Amf Panel Wi
Tender Overview
Project Description
Bids Are invited for Data Centre Infra And Managed O& ;M Services At C-Dot, Bangalore - Rmu/Vcb At Main Feed [Outdoor Rmu - Two-Way Outdoor Sf6 11Kv] , 11 Kv Ht Cable , Transformer , Ht Panels , Main Lt Panel , Dg Sets - Prime Rated , Dg Amf Panel With Change-Over , Critical Ups (Modular Live-Swappable 300 Kva) , Utility / Non-It Ups (30 Kva) , Battery – Li-Ion For Critical Ups (15 Min Backup) , Battery – Smf/Vrla For Utility Ups , Ups Input/Output Panels , Rack Pdu / Ipdu , Floor Pdu / Main Pdu , Isolation Transformer , Low-Side / Power Cabling , Pdu-To-Rack Cabling , Inrow Panel - Clc Dbs / In-Row Cooling Distribution Panel , Inrow Cooling – Dx Based (N+1) , Comfort Room Cooling (Split Acs N+1 With Auto-Sequence For Noc, Battery, Electrical/Ups & Bms Rooms Including Stabilizers & Low-Side Works) , Bms, Ibms Solutions And Its Integration , Cctv System , Fire Alarm/Detection System For Racks And Rooms (Including Vesda) , Fire Suppression (Fk-5-1-12) , Access Control System (Biometric + Rack-Level) , Water Leakage Detection System , Rodent Repellent System , Dcim Solution , Civil Works - Wall Opening & Closing, Wall Painting & Raised Floor Cut-Out, Glass Partitioning, Equipment Foundation Including Dg, Cable Routes, Deep Cleaning, Acp Cladding, Structural Glazing, Canopy, Entrance Arch, Planter Beds, Landscape, External Lighting, Hsd Tank Fencing Modification, Antistatic Vinyl Flooring, Insulation, Fire-Retardant Painting Etc. As Per Site Requirements , Noc Workstation Tables (With Drawers, Keyboard Tray, Cpu Rack & Raceways) , Bms Room Workstation Tables , High-Back Revolving Chairs , 65 Led Tvs (Wall-Mounted With Supports & Ups Power) , White Magnetic Boards (1050 Mm × 1200 Mm) With Accessories , Glow Signage (Push/Pull, Area Identification & Emergency Signs) , Public Address / Voice Evacuation System (Complete With 8-Zone Master Controller, Amplifiers, Microphones, Ceiling & Wall Speakers, Redundancy Loop) , Portable / Handheld Fire Extinguishers , Lightning Protection System (For Entire Data Centre + Transformer Yard) , Earthing & Equipotential Bonding System (Including Earth Pits, Inspection Chambers & Marking) , Rubber Mats (Is 15652) For Ht/Lt/Pdu Panels , Structured Cabling (Complete With Certification) , Cable Managers / Bus Bar Trunking , Distribution Boards (Raw Power Db, Ups Db, Cac Db, Clc Dbs) , Decommissioning, Uninstallation & Secure Shifting Of Existing Infrastructure , Statutory Approvals & Clearances (Peso, Pcb, Electrical Inspector, Fire Authority Etc.) , Training Materials / Handouts (For Up To 5 C-Dot Personnel) , Installation, A/T, Commissioning And Hand-Over , Engineering, Training, Documentation (Including As-Built Drawings, Sops, Pmps, O&M Manuals – Hard & Soft Copy) , Any Other Items Required As Part Of The Project , Tier Iii Standard Data Centre Certification (Tia 942C)
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | RMU/VCB at Main feed [Outdoor RMU - Two-way Outdoor SF6 11KV] | RMU/VCB at Main feed [Outdoor RMU - Two-way Outdoor SF6 11KV] |
| 2 | 11 KV HT Cable | 11 KV HT Cable |
| 3 | Transformer | Transformer |
| 4 | HT Panels | HT Panels |
| 5 | Main LT Panel | Main LT Panel |
| 6 | DG Sets - Prime Rated | DG Sets - Prime Rated |
| 7 | DG AMF panel with Change-over | DG AMF panel with Change-over |
| 8 | Critical UPS (Modular Live-Swappable 300 kVA) | Critical UPS (Modular Live-Swappable 300 kVA) |
| 9 | Utility / non-IT UPS (30 kVA) | Utility / non-IT UPS (30 kVA) |
| 10 | Battery – Li-ion for Critical UPS (15 min backup) | Battery – Li-ion for Critical UPS (15 min backup) |
| 11 | Battery – SMF/VRLA for Utility UPS | Battery – SMF/VRLA for Utility UPS |
| 12 | UPS Input/Output Panels | UPS Input/Output Panels |
| 13 | Rack PDU / iPDU | Rack PDU / iPDU |
| 14 | Floor PDU / Main PDU | Floor PDU / Main PDU |
| 15 | Isolation Transformer | Isolation Transformer |
| 16 | Low-side / Power Cabling | Low-side / Power Cabling |
| 17 | PDU-to-Rack Cabling | PDU-to-Rack Cabling |
| 18 | Inrow Panel - CLC DBs / In-row Cooling Distribution Panel | Inrow Panel - CLC DBs / In-row Cooling Distribution Panel |
| 19 | Inrow Cooling – DX based (N+1) | Inrow Cooling – DX based (N+1) |
| 20 | Comfort Room Cooling (Split ACs N+1 with auto-sequence for NOC, Battery, Electrical/UPS & BMS rooms including stabilizers & low-side works) | Comfort Room Cooling (Split ACs N+1 with auto-sequence for NOC, Battery, Electrical/UPS & BMS rooms including stabilizers & low-side works) |
| 21 | BMS, IBMS solutions and its Integration | BMS, IBMS solutions and its Integration |
| 22 | CCTV system | CCTV system |
| 23 | Fire Alarm/detection system for Racks and Rooms (including VESDA) | Fire Alarm/detection system for Racks and Rooms (including VESDA) |
| 24 | Fire Suppression (FK-5-1-12) | Fire Suppression (FK-5-1-12) |
| 25 | Access Control System (Biometric + Rack-level) | Access Control System (Biometric + Rack-level) |
| 26 | Water Leakage detection System | Water Leakage detection System |
| 27 | Rodent repellent System | Rodent repellent System |
| 28 | DCIM solution | DCIM solution |
| 29 | Civil works - Wall opening & closing, wall painting & raised floor cut-out, Glass partitioning, equipment foundation including DG, Cable routes, Deep cleaning, ACP cladding, structural glazing, canopy, entrance arch, planter beds, landscape, external lighting, HSD tank fencing modification, antistatic vinyl flooring, insulation, fire-retardant painting etc. as per site requirements | Civil works - Wall opening & closing, wall painting & raised floor cut-out, Glass partitioning, equipment foundation including DG, Cable routes, Deep cleaning, ACP cladding, structural glazing, canopy, entrance arch, planter beds, landscape, external lighting, HSD tank fencing modification, antistatic vinyl flooring, insulation, fire-retardant painting etc. as per site requirements |
| 30 | NOC Workstation Tables (with drawers, keyboard tray, CPU rack & raceways) | NOC Workstation Tables (with drawers, keyboard tray, CPU rack & raceways) |
| 31 | BMS Room Workstation Tables | BMS Room Workstation Tables |
| 32 | High-back Revolving Chairs | High-back Revolving Chairs |
| 33 | 65” LED TVs (wall-mounted with supports & UPS power) | 65” LED TVs (wall-mounted with supports & UPS power) |
| 34 | White Magnetic Boards (1050 mm × 1200 mm) with accessories | White Magnetic Boards (1050 mm × 1200 mm) with accessories |
| 35 | Glow Signage (PUSH/PULL, area identification & emergency signs) | Glow Signage (PUSH/PULL, area identification & emergency signs) |
| 36 | Public Address / Voice Evacuation System (complete with 8-zone master controller, amplifiers, microphones, ceiling & wall speakers, redundancy loop) | Public Address / Voice Evacuation System (complete with 8-zone master controller, amplifiers, microphones, ceiling & wall speakers, redundancy loop) |
| 37 | Portable / Handheld Fire Extinguishers | Portable / Handheld Fire Extinguishers |
| 38 | Lightning Protection System (for entire Data Centre + Transformer yard) | Lightning Protection System (for entire Data Centre + Transformer yard) |
| 39 | Earthing & Equipotential Bonding System (including earth pits, inspection chambers & marking) | Earthing & Equipotential Bonding System (including earth pits, inspection chambers & marking) |
| 40 | Rubber Mats (IS 15652) for HT/LT/PDU panels | Rubber Mats (IS 15652) for HT/LT/PDU panels |
| 41 | Structured Cabling (complete with certification) | Structured Cabling (complete with certification) |
| 42 | Cable Managers / Bus Bar Trunking | Cable Managers / Bus Bar Trunking |
| 43 | Distribution Boards (Raw Power DB, UPS DB, CAC DB, CLC DBs) | Distribution Boards (Raw Power DB, UPS DB, CAC DB, CLC DBs) |
| 44 | Decommissioning, Uninstallation & Secure Shifting of existing infrastructure | Decommissioning, Uninstallation & Secure Shifting of existing infrastructure |
| 45 | Statutory Approvals & Clearances (PESO, PCB, Electrical Inspector, Fire Authority etc.) | Statutory Approvals & Clearances (PESO, PCB, Electrical Inspector, Fire Authority etc.) |
| 46 | Training Materials / Handouts (for up to 5 C-DOT personnel) | Training Materials / Handouts (for up to 5 C-DOT personnel) |
| 47 | Installation, A/T, Commissioning and Hand-over | Installation, A/T, Commissioning and Hand-over |
| 48 | Engineering, Training, Documentation (including as-built drawings, SOPs, PMPs, O&M manuals – hard & soft copy) | Engineering, Training, Documentation (including as-built drawings, SOPs, PMPs, O&M manuals – hard & soft copy) |
| 49 | Any other items required as part of the project | Any other items required as part of the project |
| 50 | Tier III standard Data Centre certification (TIA 942C) | Tier III standard Data Centre certification (TIA 942C) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender