Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #58395258

Tender For Provision Of Technical Accommodation For Catr-H At K-Site, Kolar

Issued by Statutory Bodies & Commissions/Committees · Medchal Malkajgiri, Telangana
Tender Value
20.57 Crore
Estimated cost
Bid Submission
26 Nov 2026
3 days left
EMD
30.57 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Medchal Malkajgiri → Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Technical Accommodation For Catr-H At K-Site, Kolar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Nov-2026 Amendment in BOQ Financial Bid 26-Nov-2026

BOQ

Name of Work:- PROVISION OF TECHNICAL ACCOMMODATION FOR CATR-H AT K-SITE, KOLAR
Sl. No. Item Description
1SUBHEAD - I : EARTH WORK AND EXCAVATION
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan, depth upto 3.0 m), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
3Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan, depth upto 3.0 m), including dressing of sides and ramming of bottoms, getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
4Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil.
5Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.Ordinary rock
6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
7Excavating ( out site of site ), supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 10 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
8Supplying and filling in plinth with River sand under floors, including watering, ramming, consolidating and dressing complete
9SUBHEAD - II : ANTI TERMITE TREATMENT
10Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20%
11Diluting and injecting chemical emulsion for Pre & Post -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
12Treatment of soil under floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor.With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
13SUBHEAD - III : PLAIN AND REINFORCED CEMENT CONCRETE WORK
14Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
15(a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
16(b) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
17Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
18(a) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
19(b) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
20Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
21Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement.
22Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
23Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/ RCC/ Flooring/water retaining structures by using 125gms of synthetic Polyester triangular fibre for 50 Kg cement used as per directions of Engineer-in-Charge.
24Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
25(a) All works upto plinth level
26(i) Concrete of M25 grade with minimum cement content of 330 kg /cum
27(b) All works above plinth level upto floor V level
28(i) Concrete of M25 grade with minimum cement content of 330 kg /cum
29Add for using extra cement in the items of design mix over and above the specified cement content therein.
30Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all height & level..(a) Thermo-Mechanically Treated bars. Fe-550D
31Centering and shuttering including strutting, propping etc. and removal of form for
32(a) Foundations, footings, bases of columns, etc. for mass concrete
33(b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
34(c) Suspended floors, roofs, landings, balconies and access platform
35(d) Shelves (Cast in situ)
36(e) Lintels, beams, plinth beams, girders, bressumers and cantilevers
37(f) Columns, Pillars, Piers, Abutments, Posts and Struts
38(g) Stairs, (excluding landings) except spiral-staircases
39(h) Extra for shuttering in circular work (20% of respective centering and shuttering items)
40(i) Edges of slabs and breaks in floors and wallsUnder 20 cm wide
41(j) Weather shade, Chajjas, corbels etc., including edges
42Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies(Plan area to be measured)
43Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
44Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand
45SUBHEAD - IV : STONE & BRICK MASONRY WORK
46Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
47Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar of thickness specified by manufacturer all complete as per direction of Engineerin- Charge. ( RCC band and reinforcement all including ).
48Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
49Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand)
50Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.(a) Cement mortar 1:6 (1 cement : 6 coarse sand)
51Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand ) :(a) Flush/ Ruled pointing
52Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :
53Cement mortar 1:6 (1 cement : 6 Coarse sand)
54SUBHEAD - V : PLASTERING AND SURFACE TREATMENT
55Providing of 6mm cement plaster of mix in all surface with cement mortar 1:3 (1 cement : 3 fine sand ) at all levels
56Providing of 12 mm cement plaster of mix in all surface with cement mortar 1:6 (1 cement : 6 fine sand ) at all levels.
57Providing of 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) at all levels.
58Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster
5918 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough withsponge.
60Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers:
61Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
62Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
63Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
64Finishing walls with Apex Ultima exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
65Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
66New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
67Applying priming coat :With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
68Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
69Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
70Providing and fixing GI plaster mesh of nominal thickness 0.35 to 0.40 mm with zinc coating of 120 gms per sq m of all as per directed in charge.
71Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
72Two coats
73SUBHEAD - VI : FLOORING
74Providing and fixing 18mm thick gang saw cut mirror polished premoulded and polished machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment. epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all level(a) Granite of any colour and shade(i) Area of slab over 0.50 sqm
75Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work
76Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
77Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete
78Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
79Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.(a) Double charge vitrified tile polished finish of size
80(i) Size of Tile 600X600 mm.
81(ii) Size of Tile 1200X1200 mm.
82Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Double charge vitrified tile polished finish of any size
83Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
84Providing and laying 2mm thick self levelling anti static hard epoxy flooring Nitoflor SL Conductive of Fosroc or Approved equivalent by preparing the surface of floor by mechanical grinding and followed by vacuum cleaning to receive the flooring and laying the floor having the folloing specifications and as directed by engineer in charge 1- Compessive strength shall not be less than 500 Kg per sqcm in 28 Days2- Abraision resistance in terms of wearing property as per IS-9162-1979 shall be 0.03mm ( 30 micron) or less3- Surface resistivity in anti static conductive type is between 50 to 100K Ohms when measured for surface resistance in accordance with BS 2050: 1978 ( A-1984) and DIN/EN 1081.( The under coat resistivety value shall be 3 to 9K ohms ).4- Providing and copper tape of 0.04mm in to 25mm size which shall be placed on the anti static flooring below under coat and this copper strip shall be earthed by connecting to copper strip already provided on wall. Make - as Per approved make.
85Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, lakka Red, Elite Brown, Cat Eye or equivalent.
86Providing & laying Antistatic laminated false flooring with epoxy coated surface finish Panel is Made of good cold rolled steel sheet. Which are punched, Spotwelded, coated with epoxy powder. Inside the panel is filled with foamed cement. The steel sheet of the panel is stuck with fireproof HIGH PRESSURE LAMINATE(HPL) or conductive PVC tile Size 600mm x 600mm Thickness : 30/35mm .All steel construction with powder coated finish and cavity filled with cement slurry with complete steel structure nut bolt etc all complete as per direction of Engineer-in-charge.
87Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
88Extra for pre finish nosing in treads of steps of granite slab.
89Extra for granite in treads of steps & risers using single length upto 2 meter.
90Providing and laying Kota stone / P white slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing/ factory polished complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
9125 mm thick
92SUBHEAD - VII : DOOR WINDOW & WOOD WORK
93Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed & fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood.
94Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead including filling with cement concrete of grade 1:2:4 and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:
95a) Profile BFixing with adjustable lugs with split end tail to each jamb
96b) Profile EFixing with adjustable lugs with split end tail to each jamb.
97Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
98Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
99Second class teak wood : 50 mm thick shutters
100Providing and fixing 25 mm flush door with 8mm mdf panel both side with CNC cutting to create panelled door look with acrylic primer followed by oil based interior wood paint ( such as acrylic enamel or satin wood etc to make it goodfor doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
101Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality .1.5 mm thick
102Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
103Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
104Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete.2nd class teak wood 50x12 mm
105Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
106Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of Approved Quality)
107French spirit polishing :(a) Two or more coats on new works including a coat of wood filler
108Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
109a) For fixed portion(i) Powder coated aluminium (minimum thickness of powder coating 50 micron)
110(b) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) (i) Powder coated aluminium (minimum thickness of powder coating 50 micron)
111Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
112(a) With float glass panes of 4.0 mm thickness (weight not less than 10 kg/Sqm)
113(b) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
114Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
115a) 300x16 mm
116b) 250x16 mm
117Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:
118a) 200x10 mm
119b) 150x10 mm
120c) 100x10 mm
121Providing and fixing bright finished brass handles with screws etc. complete:
122a) 125 mm
123b) 100 mm
124Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.Twin rubber stopper
125Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
126Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
127Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.(a) Fixed to openings /wooden frames with rawl plugs screws etc.
128Providing and fixing aluminium casement window fastener of required length for aluminium windows with necessary screws etc. complete.(a) Powder coated minimum thickness 50 micron aluminium.
129Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered including fixing accessories such as nuts, bolts, fasteners etc.).
130Providing & fixing 12 mm thick frameless toughened glass in Railing With SS 304 Hollow Tube, Channel plate etc. in Staircase and balcony etc of approved brand & manufacture, including providing & fixing top & bottom clamp fixing arrangement & making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge.
131Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).
132Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made.
133b) Frame size 65 x 150 mm
134Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
13530 mm thick
136Providing and fixing factory made UPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
137(a) Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 All including. Note:- Structural design proof checked from a GovernmentEngineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3(ii) Sites with structure height more than 20m for all wind speeds
138(a) Fixed window / ventilator without mullion / transom.Using R1 series with frame (33 mm & above) x (35 mm & above). (Height upto 0.90 metre)
139(b) Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m).
140Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
141Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
142a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
143b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
144c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
145d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
146e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified.
147The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.
148Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
149Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approvingauthority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
1501. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing method for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml”
151Providing and fixing Glass Reinforced Concretepattern, design, thickness and color of M/S (G.R.C) Screens in approved size. The Screens should be made from ‘53 grade’ White Portland Cement , Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber , Super Plasticizers, Polymers and U.V resistant Synthetic inorganic pigments should be used for pigmentation . The material casting should take place in Synthetic Rubber / FRP Mould . The fixing of Screens should be ‘Dry fixing’ i.e. to be done with Stainless Steel ‘L’ shaped Clamps, dash fasteners and pins.
152Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete.
153I) With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles, with melannine polish.
154Supply & Installation of washable wallpapers of standard thickness and of approved design and pattern, fixed with appropriate adhesive etc., all complete.
155Supply and Fixing of POP moulding of required thickness in false ceiling etc., all complete.
156Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
157i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
158SUBHEAD - VIII : STEEL WORK & PEB STRUCTURE
159Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
160Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
161Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover
162Providing and fixing ball bearing for rolling shutters.
163Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
164Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture , including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
165Supply Erection & Commissioning & Insulation of Double Leaf 75mm thick MS Steel Swing Doors filled with Thermal Insulation Filling, Perimeter Weather Sealing & Wall Frame. The shutter frame build with rectangle steel tubs cladded with 3mm cold rolled sheets on both the sides. The door Leaf shall be supported on 3Nos Heavy Duty Hinges to be welded on the wall frame to allow for 180º opening of the shutter and flush to the wall when in open position, mortice locks, tower bolts, handles and all necessary hardware required for the door.(The sizes mentiioned are clear wall openings). Wall frame and Door shutters to be coated with one coat of primer and 2 coats of Epoxy final paint.
166Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
167Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
168Providing and fixing bolts including nuts and washers complete.
169Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
170(a) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
171(b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
172SUBHEAD - IX : ROOFING & WATER PROOFING
173Providing and fixing on wall face unplasticised Rigid Single socketed PVC rain water pipes conforming to IS : 13592 Type A, along with injection moulded fittings as required e.g., bends on any angle, sockets, junction, cowls, offsets, access pieces, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, providing and fixing MS stays & clamps and cutting & making good the holes in floors and walls wherever required etc. all complete. (For Rain water pipe).a) 110 mm diameter
174Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
175Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.
176Laying cement concrete using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS2645 and approved by Engineer - in- charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS:2645 and approved by Engineer - in- charge
177Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square 3mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. a) With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
178Surface Preparation : Carefully removing existing floor tiles, and underlying screed/mortar bed up to the mother slab level by mechanical/manual means, including dismantling, chipping, cleaning of debris, surface preparation to expose sound concrete substrate, disposal of waste materials outside project premises, complete as directed by the Engineer-in-Charge, including labour, tools, tackles, and all incidental works & the application of the product shall be only carried out after the thorough preparation of the surface which includes cleaning, crack treatment, grouting.
179Coving:Providing and carrying out chipping at slab–wall junctions to remove weak concrete and laitance, followed by forming polymer modified coving using special grout Easy Flow IN mixed with Planicrete SBR.
180Waterproofing: Supply and apply of one-component polyurethane waterproof membrane having highly elastic, durable, excellent physical and mechanical properties & composed of polyurethane with high tensile strength, strong resistance to the deformation of base layer (good crack-bridging ability), good bonding property & strong adhesion to the substrate. Membrane applied in two coats at a consumption rate of 1.6 kg/m² to form a thickness of 1mm will have properties Elongation of 700% (ASTM D412); Tensile strength (ASTM D412) :2.5 Mpa, Tear Strength(ASTM D 624) : 20 N/mm; Water tightness : 0.3 Mpa; Adhesion strength(ASTM D 4541) : 1.5 Mpa.Protection Layer(Not included in the rate):The waterproofing layer should be protected with cementitious screed of average 75 mm thickness over existing mother slab with necessary high and low levels to achieve required slope towards drain points.
181Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete
182Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing
183perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
184(a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
185Providing & fixing false ceiling with Armstrong ceiling tiles 'Fine Fissured' with micro look size 600 x 600 mm of approved colour. Suspension system shall be Armstrong exposed grid system with 15mm wide T section of approved shade. Installation to comprise main runners spaced at 1200mm C / C securely fixed to the structural soffit by approved hanger at 1200mm maximum centres. The last hanger at the end of each main runner should not be greater than 450mm from adjacent wall. 600 x 600 mm modules to be formed by fitting 600mm long flush fittings cross tees centrally between 1200mm cross tees, 4mm galvanised annealeg iron wire with pre straightened to be used for suspension and also including the cost of making opening for light fittings, Grills, Diffusers, cut out made with frame of primetre channels suitably fixed all complete as per drawing and specification & direction of the Engineer in charge.
186Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick
187(minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
188(a) GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
189PEB Wall & Roofing StructureThe agency has to submit the shop drawings of the shed with all required detail before placing order/ procurement for proof checking and approval by department
190PEB Roof Fabrication, supply, delivery and erection of pre-engineering building all as shown in drawing (over the readily available RCC pedestals) comprising of anchor bolts, Base Plates, MS portals, columns, frames, purlins, canopies at specified places, Puff panel sheet roofing & cladding all-round the building, gutters, down take pipes, necessary accessories required for erecting structural steel members for all heights & at all levels including provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plates, flashings and all necessary operations etc. Test reports for all materials including high strength bolts to be furnished by manufacturer.
191All web butt welds shall be full penetration welds using flux backdrop (16mm plate max) Flanges greater than 16mm thick to be bevelled prior to assembly. All welds should be subjected to NDT tests, including dye penetration inspection, ultrasonic testing, rediography as required by relevant IS codes. For general guidance on fabrication welding reference shall be made to IS: 9595. All members shall be properly protected during transportation against damage to profile or paint finish.
192The drawings given are design drawings and not fabrication drawings. The contractor shall make his own fabrication drawing and indicate is any variation noted during making of fabrication drawing. The contractor shall obtain suitable clearance from Engineer-in-charge in case of any variation found. The contractor shall not be eligible to claim extra on this account or due to any changes required for safety / stability of the structure. Any of the minor details not shown in the drawings required as per sound engineering & fabrication practices, shall be deemed to be included without any financial implication i.e. without any cost to the department. The said item can be measured in respective heads with prior approval.
193a) PRIMARY MEMBERS:Primary structural members refer to the transverse rigid frames, lean-to-rafters & columns, canopy rafters, interior columns, (beam & column frames), bearing frame rafters, corner columns, eaves strut & end wall wind columns including stiffners base plates etc complete as per drawing. All primary members shall be fabricated from plate or bar stock by continuous submerged arc welding to both sides (symmetrical) for complete finsihed item of work and shall have minimum yield strength of 345 MPa. The built up sections shall be prepared . All members shall be shot blasted as per relevant IS code and painted with 1 coat of eopxy primer and finished with two coats of epoxy paint (Burger / Asian / Nerolac) as approved by Engineer-in-Charge.
194b) SECONDARY MEMBERSSecondary structural members shall refer to purlins, girts, wind bracing, flange bracing, base abgles, clips, and other miscellaneous structural parts. All members shall be shot blasted as per relevant IS code and painted with 1 coat of eopxy primer and finished with two coats of epoxy paint (Burger / Asian / Nerolac) as approved by Engineer-in-Charge.
195i) Cold Formed Purlins, Girts, as per IS:811-1987 manufactured from precoated galvanised steel to zinc coating of 275 g/sqm having minimum yield strength of 345 Mpa . All M12 MS bolts are deemed to be included in the basic weight and nothing shall be paid extra for them.
196ii) Members like flange brace etc. formed from hot rolled steel sections like angles, chunnels, beams, plates, bars etc, having minimum yield strength of 250 MPa. All members shall be shot blasted as per relevant IS code and painted with 1 coat of eopxy primer and finished with two coats of epoxy paint (Burger / Asian / Nerolac) as approved by Engineer-in-Charge.
197iii) Pipe bracing / railing, using steel tubes as per IS: 1161-1979, Table-1 Clause 5.1, having minimum yield strength of 310 MPa. All members shall be cleaned as per relevant IS code and painted with 1 coat of eopxy primer and finished with two coats of epoxy paint (Burger / Asian / Nerolac) as approved by Engineer-in-Charge.
198iv) Anchor bolts, having minimum yield strength of 250 MPa. All M12 MS bolts are to be included in anchor bolt weights and shall be paid.
199v) Hi-Tension bolts, conforming to physical specifications of ASTM A-325 (or equivalent IS code). All high strength bolts, nuts & washers shall be zinc plated with a bronze iridite finish for easy indentification. All field connections shall be bolted (unless otherwise noted). All primary connections to columns, rafters etc shall be furnished with high strength bolts only as approved by Engineer-in-charge. (Nexo Industries, Key-Pee Industries, Key Hi Tech)
200Providing and fixing of colour coated double skin 50mm thick Puff Panel with Dencity of 40 +/- 2kg/cum effective with of panel will be 1000mm length of the panel can be varied from 2m to 11m, Roof galvalume profile sheets shape and pitch of corrugation as approved indigo Profile (0.45BMT) 0.5 Total coated thickness, High tensile with min 550Mpa yield strength metallic hot dip coated with Al-Zn alloy (55% Aluminium 43.5% Zinc, 1.5% Silicon) as per AS 1397/IS15961- Zincalume Az 150. The steel sheets shall have brand making of JSW or TATA BSL the sheet shall be fix using selfs drilling/ self tapping screws of size 100mm with EPDM seal, complete unto ant pitch in horizontal/ vertical or curved surfaces. all complete as per engineer in charge.
201i) Roofing Sandwitch Puff Panels
202ii) Canopy Soffit Panels
203Roof Skylight PanelsSupply, fixing and strengthening if any required for Light panels made of translucent fibre-glass reinforced polyster to the profile of roof puff panel called skylight and wall panel called wall light and shall be in 2.44 Kg/sqm (8 ounces/sft) conforming to U.S. Commercial Standard CS-214-517.Skylight panels are white and have a min acrylic modified resin content of 15% and shall be structural / general purpose. Standard sizes shall be 1m x 3m. Standard length for skylight shall be 3305mm and for wall light 4140mm, panels shall be 1.5mm thick with light transmitting capacity of 60% +- 5%
204Turbo VentilatorsSupply, fixing and strengthening if any required for Make “SVS-EDMONDS” Hurricane 600 Wind Ventilators model ( Size 600mm / 24\\" ) Hurricane model having 40% higher discharge capacity than any spherical wind ventilators, providing variable angle elbow to counter slope of roofing sheet thus ensuring ventilators remain perpendicular to the ground level to ensuring enhanced bearing life, better discharge capacity & preventing leakage through vane. Ventilator to rotate and exhaust in absence of wind using thermal currents inside the building.Should have Tandaco double row heavy duty ball bearing system secured in reinforced bearing holder with variable length butresses, designed to stabilise turbine at all wind speeds. Bearing should be completely isolated from corrosive environment and located between dome and top diaphragm.Turbine head and variable angle elbow shall be made from Aluminium alloy with vanes 0.71 and others 1 to 4mm thickness, Shaft of stainless steel, FRP base to be UV resistant, 0.95 m long and wide, installation and fixing hardware SS with EPDM rubber washers. Should be certified for heavy wind loads up to 198 Km/hr and resistance to leakage up to 2.5 lit/sec, 600mm dia, 745mm overall height, and 765mm top dia all as approved by Engineer-in-Charge
205Manufacture, Supply and fixing for 150 Dia MS Rain Water Pipes with 2mm thick and FRP lining with required MS clips, bends and shoe as per site conditions etc complete
206Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
207(a) Ridges plain (500 - 600mm)
208(b) Flashings/ Aprons.( Upto 600 mm)
209(c) Gutter (600 mm over all girth)
210Providing and fixing in position precoated colour sheeting in roof & wall in galvanised steel 24G. Effective width of panel will be 1000mm. Length of the panel can be varied from 2m to 11.7m. etc., all directed including self drilling screws, sealer tape, end and side laps as given belowRoof and wall panel shall be 24 gauge. Base material for colourcoated galvanized or galvalume substrate steel panels shall have minimum yield strength of 345 Mpa and will conform to the physical specifications of ASTM A-446 Grade D or A 792 or equivalent. The pure lead force zinc coating is a hot dip galvanization process conforming to ASTM A-792-AZ 150 (150 g/m) or equivalent IS:277. The painting shall be baked enamel polyster (white) or silicon polyster (coloured) with a film thickness of 1.0 mil. The reverse side shall be with 0.5 mil film thickness.Contd...
211Rib, Roof & Wall panel shall have minimum 45mm deep major ribs which taper in width from 30mm to 77mm and are spaced maximum 250mm c/c. Between major ribs additional minor ribs are stiffeneing ribs spaced at maximum 83mm c/c. Self drilling screws meeting Australian and International standard AS 3566 Class 3 (Mar 2002), with ShankGuard & Hi Grip with EPDM Washers, hexagonal Head with Chimseal 3 coated. For crest fixing: 12G x 14TPI x 55mm Hi Teks Screws ii) For Cladding 12G x 14TPI x 30mm Hi Teks Screws iii) For Over Lapping Sheets 10 G x 16 TPI x 16mm. All screws shall have hex heads, be colourcoated to match roof or wall panels. All Hi Teks screws shall be crest fixed only.Contd..
212Ultimate average pullout loads on Buildex Teks Screws shall be 7620 KN on pulin thickness of 2.4mm with gauge / TPI of 12-14.Mechanical Properties of Buildex Teks 12 G Screw shall be minimum 8.8 KN Single Shear Strength, 15.3 KN Axial Shear Strength, 13.2 KN Torsional Strength Sealer for sidelaps, endlaps and self-flashing window shall be 6mm wide x 5mm thick , asbestos fibre filled, pressure sensitive butyle tape. The sealer shall be non-asphaltic, non-shrinking, non-drying and non-toxic and shall have superior adhesion to metals, plastics & painted surface at temperatures from 500C to + 1040C. Sealer shall be Anabond make or equivalent.Roofing/Wall colour coated galvalume Panels
213Providing and fixing Armor Board (SIL–FIL) of Dawn colour between expansion joints, thickness built up using 10mm specifically extruded high performance sheet minimum density 30 kg per cum and compression strength 0.21 Kg./Sqm when tested as per ASTM D-3575 including using double sided adhesive SIL tape (manufactured by Supreme Industries Ltd. or equivalent) of 25x25x2 mm at four places per Sqm to the casted surface to form the expansion joint Armor Board (SIL – FIL) will become one side of the shuttering while the expansion joint is being created, including cost and conveyance of all materials, labour charges, sundries etc. complete as per drawings and as directed by Engineer-in-Charge.40 mm thick
214Preparing the joint. Providing and laying 40 mm wide expansion joints to roof as per details shown in the drawing and filling the same with filler board & back up chord of approved make and top 40 x 20 mm gap from finished surface shall be sealed with THIOFLEX 600 two part, polysulphide sealant, manufactured by Fosroc to BS 4254 -1983 after priming using Primer 7E. Cost inclusive of sealant material, labour for necessary surface preparation, and application and excluding of filler board & back up cord.
215Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15 mm thick.200mm wide
216SUBHEAD - X : SANITARY INSTALLATIONS
217Providing and fixing white vitreous china Wall Hung type water closet (European type W.C. pan) with low level quite, Close Hydraulic sleak seat and lid and concealed flushing cistern, including flush pipe with manually controlled device, (and handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan of size 55.5*36*35 cm (HxWxD) with white 27.5 kg approx including quiet, close hydraulic sleak seat with lid & concealed flushing cistern.
218Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
219Providing, Fixing water closet for physical Handicap cruse set of make : CERA CRANE / Merino BESCO colour snow white complete including all acessories, cutting and maing good of the wall and floor whereever require EWC ' P' cinstern soft close seat cover, Twin Flush fitting, Wash Basin of Size 510X400mm with Spatula lever basin mixer and including wall mounted Grab bar 600 long- 2 Nos. wall mounted hinged rail 750X100mm, Shower chair complete as required direction of engineer in charge
220Providing and fixing wash basin with CI brackets,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. W.BWhite vitreous china wash basin(round/oval under counter) size 580 mm x 430 mm with 15mm C.P. brass pillar tap & Bottle trap, 15mm PVC connection pipe with angle valve and CP waste).
221Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 460x300x710 having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
222Providing and fixing HPL Urinal Partition of 10-12mm thickness, of size 900 x 450 x 350 mm, lacquered glass as per direction of Engineer-in-charge.
223Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required with Kitchen sink with drain board 510x1040 mm bowl depth 200 mm
224Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. With Flexible pipe 32 mm dia
225Providing and fixing 600x450 mm or more sizes beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
226Providing and fixing soap dish of approved quality including fixing with C.P. brass screws etc. complete.
227Providing and fixing C.P. Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality colour and make.(a) 600mm x 20mm size
228Providing and fixing C.P. Brass towel ring 200 dia size complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality colour and make.
229Providing and fixing C.P. brass toilet paper holder with concealed fitting arrangement of approved quality colour and make.
230Providing and fixing Health faucet with concealed fitting arrangement of approved quality colour and make.
231Providing and fixing approved type SS Double coat hooks with concealed type screws.
232Providing and fixing 15 mm nominal bore C.P. brass short body two way bib cock 15 mm nominal bore.
233Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms.15 mm nominal bore.
234Providing & fixing in position CP Soap dispenser.
235Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
236SUBHEAD - XI : INTERNAL WATER SUPPLY & WATER COOLER
237Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. Concealed work, including cutting chases and making good the walls etc.
238a) 15 mm nominal dia Pipes
239b) 20 mm nominal dia Pipes
240c) 25 mm nominal dia Pipes
241Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
242(a) 25 mm nominal outer dia Pipes
243(b) 32mm nominal outer dia Pipes
244(c) 40mm nominal outer dia Pipes
245(d) 50mm nominal outer dia Pipes
246(e) 65 mm nominal inner dia Pipes
247(f) 80 mm nominal inner dia Pipes
248Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
249a) 15 mm dia
250b) 20 mm dia
251c) 25 mm dia
252Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
253a) 32 mm nominal bore.
254b) 40 mm nominal bore
255Providing and fixing unplasticised P.V.C connection pipe with PTMT Nuts coller and bush of approved quality and colour. With 15mm nominal bore with 45cm length
256Providing and fixing brass stop cock of approved quality :15 mm nominal bore
257Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
258Providing and fixing Storage type Water Cooler with inbuilt RO water purification system including necessary inlet/outlets, CP angle stop cock & making drain connection etc. complete including all required fittings as required.Purified water production capacity - 40 LPH, Storage capacity -80 LPH
259SUBHEAD - XII : ROAD AND HARDSTANDING
260Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :(a) All kinds of soil
261Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
262Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
263Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
264Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.
265Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer
266Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
267Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.(a) Using grade 'A' sealing compound conforming to IS: 1834.
268Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.(a) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
269Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
270Providing and applying tack coat using hot straight run bitumen of grade VG - 30, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :On W.B.M. @ 0.75 Kg / sqm
271Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
272Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous/RCC surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.New work (Two or more coats)
273Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints etc. complete
274(a) 450 mm dia RCC pipes.
275(b) 600 mm dia RCC pipes.
276(c) 900 mm dia RCC pipes.
277Providing and laying Polythene sheet (125 micron thick) confirming to IS :2508 antifriction layer on the sub base course complete as per specifications.( Overlaps atjoints of pvc sheet should be 100 mm wide )
278Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
279SUBHEAD - XIII : SEWERAGE DISPOSAL INTERNAL AND EXTERNAL
280Internal Drainage
281Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects.
282a) 75 mm dia.
283b) 110 mm dia.
284Providing, fixing,and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends as required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, reducers, flanges & plugs etc. fixing at floor level with cement concrete 1:2:4 complete as per direction engineer in charge.a) 160 mm dia.
285Providing, fixing, jointing and testing in position the following uPVC pipes conforming to IS : 4985 of 6 kg/cm2 pressure rating including all fittings like T - bend , elbow , reducer, clamps etc .with solvent joint and cement concrete around the pipe complete and making good the same complete as required. for internal toileta) 32 mm dia.
286Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. a) 110 mm inlet and 110 mm outlet
287Providing and fixing CP brass grating with frame of approved design including setting in floor with cement motor to match with floor finish as per architect requirement.a) Size 100 mm X 100 mm
288Providing and fixing floor drain of size -100 mm x 50 mm of approved quality .
289Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT.a) Size 100 mm X 100 mm
290External Sewerage
291Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m.All kinds of soil
292a) Pipes, cables etc not exceeding 80 mm dia
293b) Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
294Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming,watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :
295(a) Ordinary rock :
296(i) Pipes, cables etc not exceeding 80 mm dia
297(ii) Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
298Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
299(a) 150 mm dia. R.C.C. pipe
300(b) 250 mm dia. R.C.C. pipe
301Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of RCC pipes including bed concrete as per standard design :
302a) 150 mm dia
303b) 250 mm Dia
304Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand / M-Sand ) including testing of joints etc. complete
305a) 100 mm diameter
306b) 150 mm diameter
307Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipe including bed concrete as per standard design:
308a) 100 mm diameter
309b) 150 mm diameter
310Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design.150x100mm size P type with common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
311Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregrate 40mm nominal size ) inside plastering 12 mm thick with cement mortar 1:3 (1 Cement : 3 coarse sand) finished with floating coat of neat cement & making channels in cement concrete 1:2:4 mix (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:(a) Inside size 90x80cm and 45cm deep including S.G.R.C cover with frame (heavy duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg)(i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
312Extra for depth for manholesSize 90x80 cmWithcommon burnt clay F.P.S. (non modular) bricks of class designation 7.5.
313Supply and Installation of PVC Readymade Septic tank at suitable site and location as directed including Excavation and back filling, sewer line connection at inlet and outlat, inspection chanber etc all complite as per direction of engineer in charge.
314(b) 50 User
315Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.(a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
316SUBHEAD - XIV : INTERNAL ELECTRIFICATION WORK
317LIGHT POINTSWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
318a) Group - C
319Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
320a) Group - C
321Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
322Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
323Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
324a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
325Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
326b) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
327Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
328a) 4 X 6 sq.mm + 2 X 6 sq.mm earth wire
329Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
330a) 6 way (4 + 18), Double door
331Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
332a) 8 way (4 + 24), Double door
333Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker over current protection (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 40 A
334Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
335a) Single pole
336Supply, Installation, testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor or Electronics Ballast etc are prewired to the terminal block & mounted on are movable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. with Lamp Control Gear & Fixing Accessories.
337(a) LED Batten Surface Type Light Fixture (20 W)
338(b) LED Batten Surface Type Light Fixture (40 W)
339(c) LED Mirror Light Fixture (20 W)
340(d) LED Ceiling Light Fixture Surface Type (SQUARE) (20W)
341(e) LED Ceiling Light Fixture Recessed Type (SQUARE) (20W)
342(f) 2'x2' LED Recessed Type Light Fixture (35 W)
343(g) LED RECESSED TYPE DOWN Light (6 W)
344(h) Supply of 1 x 4W LED Bulk Head Light Fixture (4 W)
345Supply, Installation, testing and commissioning 5 meter LED strip, warm -white with adaptor, etc as approved by engineer- in-charge.
346Brush Less Direct Current (BLDC) Fan with RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. complete as required.(a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
347Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
348Supply, Installation & testing of 400mm BLDC wall bracket fan suitable for use on single phase, 230 volt, 50Hz AC supply complete with all accessories as required
349Supply of following 900 RPM Exhaust fan non metalic suitable for single phase 230/240V, AC Supply complete with motor louvers , mounting brackets, all accessories etc complete as required.a) 200mm dia
350Supply of following 900 RPM heavy duty Exhaust fan suitable for single phase 230/240V, AC Supply complete with motor MS louvers , mounting brackets, all accessories etc complete as required.a) 380 mm dia
351Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
352a) Upto 450 mm sweep
353Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
354Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
355Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 Amodular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
356Supplying and fixing 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
357Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 63 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
358Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
359Wiring for light/ power plug with 4X4 sq. mm FRLSHFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
360Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
361a) 2 x 6 sq. mm + 1 x 6 sq. mm earth wire
362Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
363a) 4 X 6 sq.mm + 2 X 6 sq.mm earth wire
364Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
365a) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
366Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
367a) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
368Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
369a) 4 way (4 + 12), Double door
370Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
371a) 6 way (4 + 18), Double door
372Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
373a) 8 way (4 + 24), Double door
374Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
375a) 8 way (4 + 24), Double door
376Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker over current protection (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
377a) 63 A
378Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
379a) 100 A, 16 KA,TPMCCB
380Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
381a) Single pole
382Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
383a) Triple pole
384Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
385a) 160 A, 30 KA 4Pole
386Supplying and fixing 63 A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
387a) 63 A, 10KA Triple Pole
388RACEWAYSupply, installation, testing and commissioning of following sizes PVC raceway with cover, junction box - above and below floor/ceiling / wall as per direction of engineer in charge with necessary supporting to distribute Power, Data and Telecom cables including necessary accessories.
389(a) 100 x 38mm two compartment
390(b) 150 x 38mm three compartment
391Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
392150 mm dia
393SUBHEAD - XV : POWER & UPS WIRING
394Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and foxing 2 nos 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
395Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
396Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
397a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
398Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
399b) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
400Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
401Wiring for light/ power plug with 4X4 sq. mm FRLSHFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
402Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
403a) 4 X 6 sq.mm + 2 X 6 sq.mm earth wire
404Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
405a) 4 way (4 + 12), Double door
406Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
407a) 6 way (4 + 18), Double door
408Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
409a) 8 way (4 + 24), Double door
410Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker over current protection (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 40 A
411Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
412a) Single pole
413MV PANELSupply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire TTA, IEC - 61439 Free Standing Floor mounted front operated MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating over two coats of Red Oxide Colour of the panel should be Siemens gray (RAL 7032). The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only & should be ordered after approval of GA Drawing from the Department.The Panel shall have atleast two spare cubicles to suit the highest rating outgoing MCCB. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type and shunt trip coils, wherever Electrical Interlocking is specified. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. All ACBs/MCCBs 160A and above shall be with Micro processor releases. All CTs/CBCT shall be resin cast type. All MCCBs below 160A shall be with Adjustable 40-100% Thermal Magnetic based releases. All ACBs/MCCBs shall be Icu=Ics=100%. All MCCBs shall be provided with spreader links and Rotary handles, and shall be provided.
414MV PANEL-1 for LABINCOMING :1250A, 50KA 3pole EDO ACB with micro processor based releases - 1 No.METERING :0-500V Digital Voltmeter with selector switch and MCBs - 1 Set0-1250A Digital Ammeter with CTs of ratio 1250/5A Class 1 Accuracy and 15VA burden and selector switch - 1 SetLED Phase indication lamps with individuals MCBs and control with toggle swithes - 1 SetCT Operated Load Manager (Similar to EM-6400) - 1 SetBUSBAR:1350 Amp. TPN Al. Busbar.OUTGOING :630 Amp 4P (50KA), moulded case circuit breaker with operating handle - 2 Nos400 Amp 4P (50KA) moulded case circuit breaker with operating handle - 1 Nos160 Amp 4P (36KA), moulded case circuit breaker with operating handle - 2 Nos100 Amp 4P (36KA) moulded case circuit breaker with operating handle - 5 Nos63 Amp 4P (36KA) moulded case circuit breaker with operating handle - 2 Nos40 Amp, 4P 10 KA MCB-09 Nos , 63Amp DP(10 KA) MCB-1 Nos.1 No 63 Amps 4P MCCB - (25KA)- with & 24 hrs Time switch with contactor & controlling of , 4 nos 16 amps 4P MCB of 10KATotal Panel shall be provided with CO2 gas suppression system.Note:- All MCCBs shall be micro processor based with Earth Fault, Over Current & Short circuit with operating handle
415MV PANEL-2 for LAB (POWER & AC)INCOMING :400 Amp 4P (36KA) moulded case circuit breaker with operating handle - 1 NosMETERING :0-500V Digital Voltmeter with selector switch and MCBs - 1 Set0-400A Digital Ammeter with CTs of ratio 400/5A Class 1 Accuracy and 15VA burden and selector switch - 1 SetLED Phase indication lamps with individuals MCBs and control with toggle swithes - 1 SetCT Operated Load Manager (Similar to EM-6400) - 1 SetBUSBAR:500 Amp. TPN Al. Busbar.OUTGOING :63 Amp 4P (25KA) MCCB with operating Handle – 14 NosTotal Panel shall be provided with CO2 gas suppression system.
416MV PANEL for HANGERINCOMING :250 Amp 4P (36KA) moulded case circuit breaker with operating handle - 1 NosMETERING :0-500V Digital Voltmeter with selector switch and MCBs - 1 Set0-250A Digital Ammeter with CTs of ratio 160/5A Class 1 Accuracy and 15VA burden and selector switch - 1 SetLED Phase indication lamps with individuals MCBs and control with toggle swithes - 1 SetCT Operated Load Manager (Similar to EM-6400) - 1 SetBUSBAR:300 Amp. TPN Al. Busbar.OUTGOING :63 Amp 4P (25KA) MCCB - 06 Nos 40 Amps 4P (25 KA) MCB - 2 Nos32 Amps 4P (10KA) MCB - 2 NosTotal Panel shall be provided with CO2 gas suppression system.
417MV PANEL (Sub-station/DG Set area)Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire IP-54, TTA, IEC-61439 Free Standing Floor mounted front operated MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating over two coats of Red Oxide Colour of the panel should be Siemens gray (RAL 7032). The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only & should be ordered after approval of GA Drawing from the Department.The PCC shall have atleast two spare cubicles to suit the highest rating outgoing MCCB. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type and shunt trip coils, wherever Electrical Interlocking is specified. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. All ACBs/MCCBs 160A and above shall be with Micro processor releases. All CTs/CBCT shall be resin cast type. All MCCBs below 160A shall be with Adjustable 40-100% Thermal Magnetic based releases. All ACBs/MCCBs shall be Icu=Ics=100%. All MCCBs shall be provided with spreader links and Rotary handles.
418Main LT PanelINCOMING :1250A, 50KA 3pole EDO ACB with micro processor based releases - 02 Nos.METERING :0-500V Digital Voltmeter with selector switch and MCBs - 1 Set0-1250A Digital Ammeter with CTs of ratio 1600/5A Class 1 Accuracy and 15VA burden and selector switch - 1 SetLED Phase indication lamps with individuals MCBs and control with toggle swithes -2 SetCT Operated Load Manager (Similar to EM-6400) - 2 SetBUSBAR:1600 Amp. TPN Al. Busbar.
419BUS COUPLER1600 Amp 415 volt, 50 kA 4P EDO ACB each complete with Microprocessor release having inbuilt overload, over voltage, under voltage protection with time delay, short circuit protection with time delay and instantaneous along with earth fault protection - 1 No.INTERLOCKINGThe Bus section and Incoming ACB's and MCCB shall be E & M interlocked to achieve the sequence of operation, in case of manual override mode.Suitable Woodwards Easygen relay - 1setDigital Energy Meter -1setLED type phase indication lamps with individual fuse and toggle switch control -1setOUTGOING :1250 Amp 50KA 4pole EDO ACB with micro processor based releases - 2 Nos.250 Amp 4P (36KA) moulded case circuit breaker with operating handle - 1 Nos 160 Amp 4P (36KA) moulded case circuit breaker with operating handle - 1 Nos
420Supply, Fabrication and fixing Out Door type enclosure Panel for above mentioned Main LT Panel
421MV CablesSupply of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part I. Armoring shall be IS 7098 Part IB
422(a) 4C X 10 Sq.mm
423(b) 4C X 16 Sq.mm
424(c ) 4C X 25 Sq.mm
425(d) 3.5C X 50 Sq.mm
426(e) 3.5C X 95 Sq.mm
427(f) 3.5C X 120 Sq.mm
428(g) 3.5C X 185 Sq.mm
429(h) 3.5C X 300 Sq.mm
430(i) 3.5C X 400 Sq.mm
431(j) 4C X 10 sqmm (HVAC)
432(k) 4C X 16 Sq.mm (HVAC)
433(l) 4C X 25 Sq.mm (HVAC)
434(m) 3.5C X 50 Sq.mm (HVAC)
435Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning 150 mm, protective covering, marking tape at 300 mm above of cable and refilling the trench etc as required.
436(a) Upto 35 sq. mm
437(b) Above 35 sq. mm and upto 95 sq. mm
438(c) Above 95 sq. mm and upto 185 sq. mm
439(d) Above 185 sq. mm and upto 400 sq. mm
440Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
441(a) Upto 35 sq. mm
442(b) Above 35 sq. mm and upto 95 sq. mm
443(c) Above 95 sq. mm and upto 185 sq. mm
444(d) Above 185 sq. mm and upto 400 sq. mm
445Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
446(a) Upto 35 sq. mm
447(b) Above 35 sq. mm and upto 95 sq. mm
448(c) Above 95 sq. mm and upto 185 sq. mm
449(d) Above 185 sq. mm and upto 400 sq. mm
450Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
451(a) 4 X 10 sq. mm (25mm)
452(b) 4 X 16 sq. mm (28mm)
453(c) 4 X 25 sq. mm (28mm)
454(d) 3½ X 50 sq. mm (35mm)
455(e) 3½ X 95 sq. mm (45mm)
456(f) 3½ X 120 sq. mm (45mm)
457(g) 3½ X 185 sq. mm (57mm)
458(h) 3½ X 300 sq. mm (70mm)
459(j) 3½ X 400 sq. mm (70mm)
460Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
461Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
462Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
463Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
464Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
465(a) 150 mm width X 50 mm depth X 1.6 mm thickness
466(b) 300 mm width X 50 mm depth X 1.6 mm thickness
467Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire IP-54, TTA, IEC-61439,Free Standing Floor mounted indoor MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium bus bar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified.The panel shall have short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturer with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same.
468UPS OUTGOING PANEL for LABINCOMING :100 Amp 4P (36KA) Micro processor based with EF, O/C & S/C moulded case circuit breaker (MCCB) with operating handle - 2 NosMETERING :0-500V Digital Voltmeter with selector switch and MCBs - 3 Set0-100A Digital Ammeter with CTs of ratio 100/5A Class 1 Accuracy and 15VA burden and selector switch - 3 SetLED Phase indication lamps with individuals MCBs and control with toggle swithes - 3 SetCT Operated Load Manager (Similar to EM-6400) - 3 SetBUSBAR:300 Amp. TPN Al. Busbar.OUTGOING :63Amp 4P (25KA) MCCB - 3 Nos63Amp 4P (35KA) Micro processor based with EF, O/C & S/C moulded case circuit breaker (MCCB) with operating handle - 4 Nos 40Amp 4P (10KA) MCB - 5 NosTotal Panel shall be provided with CO2 gas suppression system.
469Supply and providing eletrical shock treatment chart duly written in local language, hindi and english, laminated & framed.
470Supply and providing fire extinguisher CO2, type 6.5 Kg capacity trolley mounted
471Supply and providing fire extingusher DCP-5 Kg capacity (patassium bi-corbinate uria reaction)
472Supply and providing 4 nos steel bucket duly painted red colour with stand
473Supply & laying of Protective Rubber Mats 415 V 2 mx 1 m
474SUBHEAD - XVI : TELEPHONE AND LAN CONDUITS
475Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (for Telephones, TV and Data)
476a) 25 mm
477Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
478a) Telephone socket outlet
479Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
480a) TV antenna socket outlet
481Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
482Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
483a) 1 or 2 Module (75 mmX75 mm)
484Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
485a) 2 Pair
486Supplying and drawing 20 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
487Supply ,laying testing and commissioning of 20 pair 0.5mm dia PVC insulated Copper conductor Telephone armoured cable including excavation brick protection,backfilling and as approved by engineer-in-charge
488Supply and installation of following Krone connectors in MS box made out 2mm thick MS sheet including painting with two coats of synthatic enamel paint over a coat of zinc chromate primer.
489(a) 20 pair
490(b) 200 pair
491Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
492Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required.1 run of cable
493Supply, Installation, Testing, Commissioning of Equipment Rack, with front & Rear lockable door, Castors for mounting the Switches, etc. The rack shall be provided with utility sockets, LIUs, cabling with cable ties & proper cable management, fans for ventilation, cable entry plates/ports all mounting accessories, complete as per all requirements of technical specifications.
494a) 15 U Rack
495b) 32 U Rack
496SUBHEAD - XVII : LIGHTING PROTECTION SYSTEM
497Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
498Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
499Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
500Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
501Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
502Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
503Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
504Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
505(a) 100 mm dia
506SUBHEAD - XVIII : DG SETS
507Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:(A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required
508accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Confirming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricant Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level
509(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40° C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR confirming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
510(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable number of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
511(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof confirming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size between AMF panel, LT Panel and DG Set including connection
512interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,
513D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date.
51418. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. 250KVA
515Supply and Fixing of MS Exhaust Pipe of suitable size cladded with 50mm thick Glasswool insulation covered with 24SWG Aluminium sheet (As per the recommendation of OEM)
516Supply and fabrication of supports for Residential silencer/exhaust pipe made out of MS channels/ angles including cutting, welding and fabrication to the required size and painting with 2 coats of anti corrosive paint and 2 coats of synthetic enamel paint of Grey/ Black colour complete as required
517MV CablesSupply of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part I. Armoring shall be IS 7098 Part IB3.5C X 185 Sq.mm
518Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
519Supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick G.I. plate with inscription there on as directed, bolted/welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required
520Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm (57mm)
521Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
522Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
523Supply, laying, testing and commissioning of following size 1.1KV grade PVC insulated armoured multi strand copper conductor under ground cable,in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials.The cable shall conform to IS 1554/Part I.
524(a) 14core 1.5sq.mm
525(b) 4core 2.5sq.mm
526Providing Indoor ordinary end terminations for the cable specified above with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland.
527(a) 4core 2.5sq.mm
528(b) 14core 1.5sq.mm
529Supply and laying of following size strips including all necessary interconnections with earth station and equipments.50 X 5mm GI strip
530Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
531SUBHEAD - XIX : FIRE ALARM SYSTEM
532Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230±5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
533(a) Two Loop Panel.
534Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
535Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
536Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
537Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
538Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.
539Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
540Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
541Supplying, installation, testing & commissioning of addressable manual call point complete as required.
542Supply, Erection, Testing and Commissioning of horizontal mounted Siren, 2.5 Km radius including Electrical connections etc., complete.
543Supplying, installation, testing & commissioning of addressable fire control module complete as required.
544Supplying, installation, testing & commissioning of fault isolator complete with base as required.
545Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
546Supply, Installation, Testing & commissioning of Desktop Computer system with 12th Generation i7 processor, 16 GB DDR3 RAM, 1 TB HDD, 21 inches HD Monitor, 2 GB Graphic Card with all necessary original software UPS with minimum 30 minutes back up complete with working desk and revolving chair.
547Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
548Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 µm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA- 568C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 607931/60794-1- 2, ITU-T-REC G.652D and Telecordia GR20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be 5 deg. C to +50 deg. C and Storage Temperature should be 5 deg. C to +50 deg. C, Maximum Attenuation ± 3.5 d B/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 µm and 125 ± 1µm correspondingly i/c splicing & marking etc complete as required.
549(a) 6 Core Multi Mode Optical Fiber Cable
550SUBHEAD - XX : HIGHBAY LIGHT
551Supplying and fixing of high way light fitting LED type next generation energy saving environment friendly and robust high way LED with PDC (pre die cast) housing suitable for ceiling (surface/suspended) mounting with system facility up to 15lm/w complete all fixing accessories. (Philips cat no: BY718P LED200S 65 NB PSD GR or equivalent)
552Supply, laying, testing and commissioning of following size 1.1KV grade PVC insulated unarmoured multi strand copper conductor on existing cable tray with all installation materials complete as required.
553(a) 3core 4sq.mm
554Supply, laying, testing and commissioning Scare cannon Gun – Electric with power adapter
555Supply, laying, testing and commissioning Bird Laser – Automatic with power adapter , Automatic Rotation 360 Degree.
556Supply, laying, testing and commissioning Hawk Laser Bird scanner 360 – 500 mW power adapter
557Supply and install Bird Spikes of plastic bird spikes
558SUBHEAD - XXI : AREA LIGHTING
559Supply, erection, testing and commissioning of Decorative type pole of 4.0 meter height with 30/35 Watt LED post top mounted on top of pole and The pole shall have decorative MS PU painted base pole more than dai 89mm & top 76mm from base plate to top of the pole. The pole average thickness not less than 3mm.The pole shall have M.S base plate of size 300mm x300mm x10mm at bottom with arangement of fixing 4 nos foundation bolts for proper fixing of pole. The pole shall have service window atbottom profile. The pole shall be provided with built in control box for 3core 2.5sq.mm copper conductor cable, MCB control and 2nos of 40mm dia Class B GI pipe for incoming and outgoing cable etc.The Pole shall be coated with PU painted with rust free and with require sutaible items.Lokozo Make Cat no. SL03-xx 30W/ Wipro-LP07-431-XXX-57-CL
560Supply, erection, Testing & Commissioning of bollard LED light 150 Watts of 0.80M high (above ground), including necessary fixing arrangement, connectors for loop-in loop-out arrangement and fixing accessories complete as required. (8W)
561Supply, erection, Testing & Commissioning of 10W/1100 lumen, 2 way wall washers, metal body, IP65 light fixture of including necessary fixing arrangement, connectors for loop-in loop-out arrangement and fixing accessories complete as required. (10 W)
562Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.
563MV CablesSupply of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part I. Armoring shall be IS 7098 Part IB
564(a) 4C X 10 Sq.mm
565Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
566(a) Upto 35 sq. mm
567Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
568(a) Upto 35 sq. mm
569Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
570(a) Upto 35 sq. mm (clamped with 1mm thick saddle)
571Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
572(a) 4 X 10 sq. mm (25mm)
573SUBHEAD - XXII : EXTERNAL WATER SUPPLY
574Providing and fixing G.I. pipes (Class-B) complete with G.I. fittings including trenching and refilling etc.
575(a) 32 mm dia
576(b) 40 mm dia
577(c) 50 mm dia
578(d) 65 mm dia
579(e) 80 mm dia
580Supply, installation, testing and commissioning of CI Butter fly valve of class PN 1.0 suitable for fixing between two flanges, including bolts, nuts, rubber insertions complete and of following sizes etc complete.
581(a) 50 mm dia
582(b) 65 mm dia
583(c) 80 mm dia
584Providing and fixing gun metal non- return valve of approved quality (screwed end) :
585(a) 50 mm dia Horizontal / Vertical
586(b) 65 mm dia Horizontal / Vertical
587(c) 80 mm dia Horizontal/ Vertical
588Supplying, Installation, Testing and Commissioning of CI / DI body flanged (both ends) type serviceable suction / Y strainer with (stainless steel / brass mesh) conforming to relevant IS specifications amended upto date complete including providing and fixing nuts, bolts, washers, gaskets etc. complete as required.a) 80 mm dia
589Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design.(a) With common burnt clay F.P.S. (non modular ) bricks of class designation 7.5.
590SUBHEAD - XXIII : LIFT WORK
591Supply, erection, testing and commissioning of electic 8 Passenger capacity Machine less lift of 544 kg. capacity to serve Ground & First & Second floors ( total 3 stops & 3 openings) with a total travelling length of approximately 12.0 mtrs. including elevator, VVVF drive, machines, controllers, car body, car guides, landing doors, counterweights, main suspension steel rope, cabling, safety device and governer, automatic sliding doors for car and landing hoist way with full height IR sensor, buffers for car and accessories including intermediate supporting channels/ brackets for car guides with all allied works and scaffolding etc. and supply, erection, testing and commissioning of automatic rescue device (ARD) system operating on 4x12 V - 24 AH dry maintenance free batteries with 10 second actuation time and automatic switch over facility including all neccessary cables and termination, touch panel etc. complete.
592CAPACITY (kgs) : 544 Kg, 8 persons.SPEED (mps) : 1 mpsRISE (m) : 12 mCONTROLLER TYPE : ACD3-MRLDRIVE : VF Regenerative (Closed Loop)POWER SUPPLY : 400/415 Volts (3 Phase AC)OPERATION : Full collective operationCAR GROUP : One car (simplex)MACHINE : PM Gearless (Located in shaft on top of guide rails)TRACTION MEDIA : Flat Coated Steel Belt
593CAR FINISH : • Rear Mid Panel = Stainless Steel #4(mirror finish)• Rear Corner Panels = Stainless Steel #4(mirror finish)• Side Mid Panels = Stainless Steel #4(mirror finish)• Side Corner Panels = Stainless Steel #4(mirror finish)• Front Panels = Stainless Steel #4(mirror finish)FALSE CEILING TYPE : CD-41FLASE CEILING FINISH : Stainless Steel #4(mirror finish)VENTILLATION : Cross flow fanHAND RAILS : Stainless Steel Mirror Finish Handrails on rear car panelsFLOORING : GRANAMITECAR DOOR FINISH : Stainless Steel #4(mirror finish)LANDING DOORS FINISH : Stainless Steel #4(mirror finish)FIRE RATED DOORS : Fire rating-120mins
594CAR DIMENSIONS (W x D x H - mm) :1000 mm W x 2400 mm D x 2200 mm D or suitable to accomodate door .CAR & HOISTWAY DOOR TYPE : Central opening (CO) doorsDOOR OPENING (W x H - mm) : 900 mm W x 2100 mm H with GlassDOOR OPERATOR : DC Door OperatorCOP : COP for stops <= 12 (950mm) in Stainless Steel #4(mirror finish)CAR POSITION INDICATOR : Monochrome LCD-Blue Background & White font Dot matrix (LED) Scrolling DisplayHALL FIXTURES : O2000 Pan Type Fixture ,HALL FIXTURE FACE PLATE : Stainless Steel #4mirror finish)HALL BUTTON ARRANGEMENT : LCD Monochrome type
595STANDARD FEATURES : Anti-nuisance Car Call ProtectionIndependent Service (for Duplex only) Overload DeviceNudgingEmergency Car Light UnitInfrared Curtain Door ProtectionDoor Time ProtectionEmergency Alarm ButtonExtra Door Time of Lobby & ParkingDoor Open/Close ButtonManual Rescue OperationBelt Inspection DriveAuto Fan Cut OffOPTIONS INCLUDED : Emergency Firemen’s Service,Automatic Rescue operation
596SUBHEAD - XXIV : AIR CONDITIONING
597VRV/VRFSystem
598Outdoor Unit
599VRV/VRFSystem:
600Supply, Installation, testing and commissioning of AIR COOLED & INVERTER BASED VARIABLE REFRIGERANT VOLUME / VARIABLE REFRIGERANT FLOW MODULAR TYPE AIR CONDITIONING SYSTEM with R410A suitable for 415 ± 10% , 50 Hz. The unit shall consist of indoor units and external condensing units and other accessaries as listed below complete in all respects as under
601Outdoor Unit
602SITC Modular type outdoor units equipped with highly efficient Heat Pump inverter type scroll compressor(s) with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated. Outdoor units shall have both cooling & heat pump mode, and environmet friendly refrigerant R-410A.The C.O.P shall be confirmed by vendor at full and part load at.Complete with M.S mounting stand of approved design for outdoor unit.Nitogen Flushing before gas charging.Pressure testing should be done after installation.Anti corrosive coating should be done at site.
603(a) 4 HP
604(b) 16 HP
605(c) 18 HP
606(d) 20 HP
607Indoor Units:
608Supply,Installation, testing and commissioning of both interconnected with copper refrigerant & drain pipe of required length, insulation, full charge of refrigerant gas and oil, M.S. base frame duly primered & painted, supports etc. complete as per specifications and drawings.
609Supply,Installation, testing and commissioning of Air Cooled VRV/VRF HI-Wall Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan, insulation, pipe connections,control and power panel with Cordless remote control etc. of various capacities as per specifications and drawings.
610(a) 1.02 TR
611(b) 1.28 TR
612(c) 1.59 TR
613(d) 2.01 TR
614(e) 2.3 TR
615(f) 2.8 TR
616Cassette Unit (for VRV):
617Supply,Installation, testing and commissioning of Air Cooled VRV/VRF One/Four way Cassette Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan, insulation, pipe connections,control and power panel with Cordless remote control etc. of various capacities as per specifications and drawings
618(a) 1.28 TR 4-way Cassette
619(b) 1.02 TR One-way Cassette
620(c) 1.59 TR One-way Cassette
621(d) 2 TR One-way Cassette
622Ductable Unit (for VRV):
623Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Air Decontamination Chamber in the supply air/ plenum comprising of nanoX coating plasmOX having EPA approved metallic compound of five metals targeted on Alumninum matrix cell duly enclosed by a poly quartz casing tube with the capability to produce ionized Hydroxyl oxidizers using plasmoX along with Antimicrobial coating EPA Approved. The unit shall have inbuilt multipin ion generator pins (+- ions 10^6). The cell will have built in LED indication system stating the operation of the system. The power / control cabling between the Pentagon units and the power source / controls shall be included in the cost. The wattage of the lamp shall not be less than 13 watts for CFM upto 1200 CFM and 21 watts upto 5000 CFM. Cont...
624Cont... The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall have to CE, ISO 13485, ROHS with 2014/35/EU Low Voltage Directive as well have ICMR approved lab/ CSIR certiffication for COVID-19 certififcation with a kill rate of greater than 99% within 45 mins. The product shall have Green Pro certification. The specific certifications shall be submitted along with the technical submital. The pentagon cells should be selected by considering a load factor calculation for each specific area where the equipment is to be installed. The Cells Should be complete with Transformers, control cabling and Plug Top & necessary power cable. The units shall be 100 percent manufcaturered in India. Vendor to comply all Tender Specifications. etc. of various capacities as per specifications and drawings
625(a) 7.95 TR Ductable
626(b) 6.36 TR Ductable
627(c) 5.48 TR Ductable
628(d) 4.55 TR Ductable
629(e) 3.18 TR Ductable
630(f) 2.55 TR Ductable
631Installation &Allied Works:
632Y-joints & header etc above complete as per specification and drawings.
633Supply,Installation, testing and commissioning of Centralised Analog remote controllers for operation & status monitoring of VRV/VRF indoor units
634COPPER REFRIGERANT PIPING
635Refrigerant Piping:
636Supply,installation,testing and commissioning of Interconnecting refrigerant pipe work with (19mm/13 mm thick) , Class 'O', k value-0.035 w/mk minimum, Density not less than 55 Kg/cu.m closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed Refrigerant piping will be coated with three layers of feviprotekt (only pidilite) weather coating.
637(a) 6.4 mm O.D. (insulation : 13 mm)
638(b) 9.5 mm O.D. (insulation : 13 mm)
639(c) 12.7 mm O.D. (insulation : 13 mm)
640(d) 15.9 mm O.D. (insulation : 13 mm)
641(e) 19.1 mm O.D. (insulation : 13 mm)
642(f) 22.2 mm O.D. (insulation : 13 mm)
643(g) 28.6 mm O.D. (insulation : 19 mm)
644(h) 34.9 mm O.D. (insulation : 19 mm)
645(j) 41.3 mm O.D. (insulation : 19 mm)
646HI - WALL SPLIT SYSTEMS
647Split HI-Wall Type
648Supplying, fixing, testing and commissioning of Hi Wall type Heating and Cooling Type split air-conditioning unit suitable to operate from 230±10% volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed rotery / reciprocating compressor condenser coil, propeller fans controls, control panel, Including control wiring, necessary power cable, M.S. frame duly painted to locate Outdoor Unit etc. The Unit should be atleast 5 Star rated. The Refrigerant pipe size and gas quantity should suit to the copper pipe length at actual.Upto 15 metre copper Pipe with cable tray shall include in the quote.
649(a) 2.0 TR
650Supply and erecting fully automatic line voltage stabilizer for operation on input voltage 200V to 250V rated for the following KVA maximum load and time delay model with 16A, 3-way connector/ socket for output and with 3 core flexible chord and 3 pin 6/16A plug top for input suitable for Air-conditioner for continuous operation including cost and conveyance of all mateials and all labour charges etc., complete.
651(a) 5 KVA
652Drain Piping:Supply,installation,testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber class ‘O’ . Providng and fixing pipes with all necessary fittings, supports and insulation.
653(a) 25 MM
654(b) 32 MM
655(c) 40 MM
656Inline Fans :
657Supplying, Installing, Testing and Commissioning of Inline fans complete with motor, supporting frame, gravity louvres,etc. as per drawings and specifications. @ 15mm Static.
658(a) 1900 CFM Inline Fan
659(b) 1300 CFM Inline Fan
660(c) 550 CFM Inline Fan
661(d) 500 CFM Inline Fan
662(e) 300 CFM Inline Fan
663(f) 200 CFM Inline Fan
664(g) 100 CFM Inline Fan
665Ducting:
666Supply, fabrication, installation, balancing and commissioning of factory fabricated GI sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings of following gauges as per SMACNA standard:-
667(a) Thickness 24 G sheet
668(b) Thickness22 G sheet
669(c) Thickness20 G sheet
670(d) Thickness18 G sheet
671Duct Insulation-Supply, installation, testing of thermal insulation of supply air ducting with closed cell Nitrile Rubber with prelaminated Aluminium foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R.value should be as per ECBC Code.
672(a) 19 mm
673Duct Acoustic Lining-Providing and fixing duct acoustic lining with galss wool insulation covered with 0.5 mm perforated aluminium sheet, nuts, bolts etc. complete as per specifications and drawings.
674(a) 25 mm
675Supplying and providing under deck insulation with 25mm thick resin bonded glass wool having densitity of 32 Kg / Cum covered with reinforced plastic tissue paper and 0.5mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins complete as per specifications.
676Grilles/Diffusers:
677Supply,installation, testing and commissioning supply and return air grilles/ diffusers as per specifications and drawings including fixing frame of G.I./wooden in false ceiling/walls.
678(a) Aluminium supply air grill with VCD
679(b) Aluminium return/exhaust air diffuser without VCD
680(c) Aluminium Supply air Diffuser with VCD
681(d) Aluminium return air grill without VCD
682(e) Aluminium volume control damper
683(f) Fresh / Exhaust air louvers with bird screen & damper
684Control & Transmission Wiring
685Supply,installation,testing and commisioning of control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable 25 MM PVC conduits between indoor and out door unit & outdoor units to central remotes controllers.
686Electrical AC PANEL:
687Supplying, assembling, erecting, connecting, testing and commissioning of (IP55), TTA, IEC 61439, dust, damp and vermin proof free floor standing factory built sheet steel enclosed non-drawout modular type Panel fabricated out of suitable sized angle iron and flats, base channel and covered with 2.0mm thick PCRC sheet, duly painted complete with earth bus, aluminium bus bar, numbering & sign writing, interconnection & including the cost of connection through bus bar / copper conductor flexible connection with all accessories, rotary handles,phase barriers etc. complete as shown in drawing & as per specifications and mounted with the followings etc. complete as required. (All the starters should have NO/ NC contacts for remote/ fire control facility etc. complete)
688Incomer
689(a) 1 No. 630 Amps MCCB 35 KA TP+NL incoming.
690(b) 1 No. 800. Amps aluminium conductor bus bar duly sleeved
691(c) 1 No. electronic energy meter with CTs.
692(d) 1 No. Ammeter with ASS & CTs.
693(e)1 No. voltmeter with VSS.
694(f) 3 Nos. phase indicating lamps
695(g) 3 Nos. On,Off,Trip indicating lamps
696Outgoing:-
697(a) 18 No. 63 A TPN MCCB '10 ka' for VRV/VRF (3 Spare).
698SUBHEAD - XXV : ACCESS CONTROL SYSTEM
699Supply, Installation, Testing & Commissioing of Networkable Multi output reader support Access controller supporting up to 4 doors & 4 Readers (wiegand) & 8 Readers (OSDP) communication protocol, having on board TCP-IP, 32 bit RISC CPU Processor, 50000 Card Holder Capacity, supervised Inputs/Alarm, OSDP protocol support to configure any 3rd party devices like readers / biometrics, Anti pass back (Local / Global), Blacklist Employee Management, Email / Alarm Notification on various events like Terminal Disconnected, Terminal Tampered, Door not closed, Door forced open etc., Fire Alarm Integration, including 15V DC / 5.5 Amp power supply unit complete with Battery charging unit & suitable aesthetic enclosure complete with all accessories as required.
700Supply, Installation, Testing & Commissioning of Contactless Multi modal Face Recognition & Fingerprint Terminal, Supports Walk through type Face Detection & Authentication from up to 3 meters, Face enrollment through mobile image capture, FBI PIV Certified Sensor with Live & Fake Fingerprint Detection Technology, Live Face Dectection Feature, Android OS, min 5\\" Touch Screen LCD or better, up to 20,000 Face on 1:N < 1 sec, up to 1,00,000 Fingers on 1:N < 1 sec, min 50,00,000 Transaction Logs with 20,000 picture logs, Multi Class Card (EM & Mifare) support, TCP/IP, Wiegand In / Out, RS 485 communication protocol, Built in Lock Control, shall be configurable with any 3rd party controller on Wiegand output, Anti pass back (Local / Global), Blacklist Employee Management, Email / Alarm Notification on various events like Terminal Disconnected, Terminal Tampered, Door not closed, Door forced open etc.
701Supply, Installation, Testing & Commissioning of Fingerprint, Smart Card & PIN based Reader, Fingerprint Sensor with Live & Fake Fingerprint Detection Technology, min 2.5\\" Screen LCD or better, up to 10,000 Fingers on 1:N < 1 sec, min 50,000 transaction Logs, support, TCP/IP, Wiegand In / Out, RS 485 OSDP communication protocol, Built in Lock Control, shall be configurable with any 3rd party controller on Wiegand / OSDP output, Anti pass back (Local / Global), Blacklist Employee Management, Email / Alarm Notification on various events like Terminal Disconnected, Terminal Tampered, Door not closed, Door forced open, IP 65 & IK09 complaint etc.
702Supply, Installation, Testing & Commissioing of Smart Card Reader supports Mifare cards CSN reading, having read range of 7-10 cms, configurable with multi door controller on OSDP & Wiegand communication, complete with all accessories as required.
703Supply of Standard CreditCard Size (4kB) contact less Smart Cards withWhite Glossy Finish as per the technical specifications complete with all accessories as required
704Supply, Installation, Testing and Commissioning of Web based Access Management Software supports Real time monitoring of logs, events, Graphical representation of Floor Plans, Multi Operator Login, Multi Location integration, Admin Authority Management, Alarm Management, Device Management, User Management, Log Management, Blacklist User configuration, Time Zones, Access Groups, Anti Passback, shall be compatible with any 3rd party reporting time and attendance Software with user defined generic reporting, Visitor Management for 24 Doors and 1000 CardHolders /persons etc. complete with all accessories as required.
705Supply and Laying of of 8 Core x 0.75 sq mm multistrand, copper , shielded armoured Cable (between the card readers & theaccess controllers) complete with all accessories as required.
706Supply, Installation, Testing and Commissioning of Single Leaf Electromagnetic Locks (fail safe type) of 12V DC / 24V DC 600lbs holding force complete with monitoring (APS), 45 minutes Fire Rating, UL Listed, must have been subjected to mandatory tests of Radiation Emission test, Harmonic Current Emission test, Voltage Fluctuation test, Flicket test, Electrostatic Discharge Immunity test, Magnetic Field Immunity test, Burst & Surge test etc. complete with all L / U / ZL mounting brackets, internal wiring & all accessories as required.
707Supply, Installation, Testing and Commissioning of Double Leaf Electromagnetic Locks (fail safe type) of 12V DC / 24V DC 600X2 lbs holding force complete with monitoring (APS), 45 minutes Fire Rating, UL Listed, must have been subjected to mandatory tests of Radiation Emission test, Harmonic Current Emission test, Voltage Fluctuation test, Flicket test, Electrostatic Discharge Immunity test, Magnetic Field Immunity test, Burst & Surge test etc. complete with all L / U / ZL mounting brackets, internal wiring & all accessories as required.
708Supplying, Installation, Testing and Commissioning of touchless exit push button with detection range adjustable from 4-12 cms , min 0.1 million cycle tested, primary motion sensing through infrared sensor , time delay adjustable upto 25 secs 12vDC/24VDc selectable complete with all accessories as required.
709Supplying, installation, testing & commissioning of full height flap barrier, internal gate, 1200mm or more high glass panel standard metlic gray polyurathine / SS finish & plain SS side panels stack in memory of minium 6 authorisation per way one normal walk way 550mm algorithm based diduction system, to avoid tail gating with card reader integration for in / out.
710Supplying, installation, testing & commissioning of high grade workstation machine for access control SW applcaition with i5 processor, 8 GBRAM, 21 \\" LED monitor & 1TB hdd, Licensed Microsoft Windows 7 & other operating software with 600VA UPS complete with all accessories asrequired.
711Supply & fixing of SS embrose Signages
712Providing and fixing signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+ -10%) containing lumigen II as base chemical, covered under UV stablized coating and of appropriate size (Glo-lite or equivalent Make) including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats anchor fasteners etc. complete in all respacts as diercted by Engineer-in-charge.
713SUBHEAD - XXVI : ARBORICULTURE, LANDSCAPING WORK
714GOOD EARTH :
715Supplying and stacking of good earth at site including royalty and carriage upto 5 Km complete (earth measured in stacks will be reduced by 20% for payment).
716ARBORICULTURE AND LANDSCAPING WORKS (TO ENSURE LEAST ATTRITION RATE, All the rates under subhead -XXVI are inclusive for six month maintenance, manuring, of plants from the date of completion. Agency shall provide plants as per description in lieu of dead plant at the end of six month beyond date of completion.
717AVENUE TREES PLANTATION:
718Digging holes in ordinary soil & refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish & surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :
719Holes 1.2 m dia and 1.2 m deep
720Supplying & Stacking of well decayed cattle manure at site including royalty & carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).
721Mixing earth & sludge or manure in the required proportion specified or directed by the officer-in-charge/Engineer-in-charge.
722PLANT SAPLING :
723Supply & stacking of following foilage or desired, well grown tree sapling with dieseas / insect free, good foilage and stem girth, well developed root system & about 2-4 years old in Poly / HDPE bag having minimum height as below mentioned including replacing the causalties with the same size & girth of tree sapling if any.
724Providing and stacking of Bottle Palm of height 270 - 300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the Engineer-in-Charge.
725Platation of trees, shrubs and hedge at site i/c watering and removal of unserviceable materials (excluding cost of plant & water) as per direction of Engineer-in-Charge.
726Cost of plantation per tree.
727ORNAMENTAL PLANTS (IN PITS):
728Digging holes in ordinary soil & refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish & surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :
729Holes 60 cm dia, and 60 cm deep
730Supplying & stacking of well decayed cattle manure at site including royalty & carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).
731Mixing earth & sludge or manure in the required proportion specified or directed by the officer-in-charge/Engineer-in-charge.
732PLANTS:
733Supply & Stacking of flowering or foilage or desired, well grown Ornamental plants sapling with disease / insect free, good foilage & stem girth, well developed root system & about 3-4 years old in Poly /HDPE bag or Earthen/ Cement pots having minimum height as below mentioned after the plantation from the surface of the ground at site work. After plantation tree saplings are to be maintained for a period of one month including replacing the casualties with the same size and girth of tree sapling if any.
734Supply & Stacking of Phoenix palm plant with well developed having 20-25 to 15 leaves fresh healthy leaves 90-105 cm ht. with in in 30cm cement pot as per direction of the Engineer-in-charge.
735Supply & Stacking Ficus Starlight plant with fresh, healthy & attractive foliage 45 to 60 cm spread 90 to 120 cm ht., specimen bushy plant in Poly bag/ Cement pot as per direction of the Engineer-in-charge.
736Supply & stacking of Ficus benjamina (black) plant well developed with fresh & healthy foliage from top to bottom with single piller good spreading of height 150-180 cm., in big size HDPE bags as per direction of Engineer-in-charge.
737Supply & stacking of Plumeria alba dwarf plant of height 90-105 cm. with 3-4 branches & thick stem in big size HDPE bags as per direction of Engineer-in-charge.
738Plantation of Trees, Shrubs & Hedge at site i/c watering & removal of unsaverieable material’s as per direction of Engineer-in-charge (excluding cast of plant & water).
739Cost of plantation per Trees plants
740LAWN DEVELOPMENT:
741Trenching in ordinary soil up to a depth of 60 cm including removal & stacking of serviceable materials & then disposing of surplus soil, by spreading & neatly leveling within a lead of 50 m & making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / & manure before & after flooding trench with water (excluding cost of imported earth, sludge or manure).
742Supplying & stacking of well decayed cattle manure at site including royalty & carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).
743Rough dressing the trenched ground including breaking clods.
744Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
745Fine dressing of the ground.
746Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge. (cost of sludge, dump manure and/or good earth to be paid separately).
747Mixing earth & sludge or manure in the required proportion specified or directed by the Engineer-in-charge.
748HEDGE PLANTATION:
749Preparation of beds for hedging & shrubbery by excavating 60 cm deep & trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering & finally fine dressing, leveling etc. including stacking & disposal of materials declared unserviceable and surplus earth by spreading & leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
750Supplying & stacking of well decayed cattle manure at site including royalty & carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).
751Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge. (cost of sludge, dump manure and/or good earth to be paid separately).
752Mixing earth & sludge or manure in the required proportion specified or directed by the Engineer-in-charge.
753HEDGE PLANTS:
754Supply & Stacking of approved Hedges as per following with well developed root system, true to variety/type, disease free & healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work.
755Supply & Stacking of Clerodendrum inerme plant of height 20 cm to 30 cm. Multi branches in Poly bag & as per direction of the Engineer-in-charge.
756Plantation of Trees, Shrubs & Hedge at site i/c watering & removal of unsaverieable material’s as per direction of Engineer-in-charge (excluding cast of plant & water).
757Cost of plantation per Hedge plants
758POTTED PLANTS (Indoor & Outdoor):
759Providing & displaying of the following well developed, true to variety, disease free & healthy plant having minimum height as below mentioned at site work :
760Providing & displaying of Araucaria cookie plant, having ht. 1.20 m to 1.35 m, straight, well developed, fresh & healthy with lush green leaves from bottom to top in 25 cm size of Earthen pot / Plastic pot & as per direction of Engineer-in-charge.
761Providing & displaying of Areca palm plant, having ht. 1.80 m to 2.10 m with 8 to10 suckers, well developed, fresh & healthy with lush green foliage in 30 cm size of Earthen pot / Plastic pot & as per direction of Engineer-in-charge.
762Providing & displaying of Oxycardium Golden mounted on moss stick 1.20 m ht., having 3-4 s plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm size of Earthen pot / Plastic pot & as per direction of Engineer-in-charge.
763Providing & displaying of Raphes palm plant, having ht. 45 cm to 60 cm with with 5-7 suckers, well developed, full of fresh & healthy in 25 cm size Earthen pot / Plastic pot & as per direction of Engineer-in-charge.
764Supplying of 12\\"x 12\\"size of FRP square pot in White colour with 12\\"height as per direction of Engineer-in-Charge. (as per photo attached). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58395258
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20.57 Crore
LAST DATE 26-11-2026
Authority
Authority Name Defence Research And Development Organisation
Work Description Tender for Provision Of Technical Accommodation For Catr-H At K-Site, Kolar
Basic Detail
Tender No CCEESTS/ENQ/CIV/DYSL-AT/ HYD/172/2026-27
Bidding Type Tender
Location
City Medchal Malkajgiri
State Telangana
Key Dates
Publish Date 18 Nov 2026
Submission Date 26 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 20.57 Crore
Tender Fee Ref. Documents
EMD 30.57 Lakhs
Exemption Not Available
Document List
1_Site_PLan.pdf
2_Floor_Plans_G_2.pdf
3_GROUND_HANGER_ANNEXE.pdf
5f8bf9bf-6a18-422c-8a6a-6686ef5b3669.html
Annexures_I_to_VI_NIT.pdf
Annexure_II.pdf
Annexure_III.pdf
Annexure_V.pdf
Annexure_VI.pdf
Annexure_VII.pdf
Approved_Makes.pdf
Approved_Makes_EnM.pdf
BGB_Proforma.pdf
BOQ_980755.xls
GCC.pdf
GCC_2023.pdf
Integrity_Pact.pdf
Special_Conditions.pdf
Tendernotice_1.pdf
Tender_Enquiry.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
pdf

1_Site_PLan.pdf

pdf

2_Floor_Plans_G_2.pdf

pdf

3_GROUND_HANGER_ANNEXE.pdf

html

5f8bf9bf-6a18-422c-8a6a-6686ef5b3669.html

pdf

Annexures_I_to_VI_NIT.pdf

pdf

Annexure_II.pdf

pdf

Annexure_III.pdf

pdf

Annexure_V.pdf

pdf

Annexure_VI.pdf

pdf

Annexure_VII.pdf

pdf

Approved_Makes.pdf

pdf

Approved_Makes_EnM.pdf

pdf

BGB_Proforma.pdf

xls

BOQ_980755.xls

pdf

GCC.pdf

pdf

GCC_2023.pdf

pdf

Integrity_Pact.pdf

pdf

Special_Conditions.pdf

pdf

Tendernotice_1.pdf

pdf

Tender_Enquiry.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender