Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #58391985

Tender For Repair/ Replacement Of Lt Cables Of Mafi Installations And Mafi Eqpt At Runway Pavement -Ii Under Ge (Af) Tezpur

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
42 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
10 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Lt Cables Of Mafi Installations And Mafi Eqpt At Runway Pavement -Ii Under Ge (Af) Tezpur

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF LT CABLES OF MAFI INSTALLATIONS AND MAFI EQPT AT RUNWAY PAVEMENT –II UNDER GE (AF) TEZPUR
Sl. No. Item Description
1Excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, taking Out and laying of cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
2All as per item No 1.00 here in before but Excavation in trenches exc. 1.5m but n. exe 3 mtr depth, complete all as specified and directed.
3Returning, filling in, including spreading, levelling, watering and well ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
4Removing excavated Materials (Soils) not exc. 50.00 mtr distance and depositing where directed at a level not exc. 1.50 mtr above the starting point, complete all as specified and as directed.
5Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path/PCC/Duct, complete all as specified and as directed.
6M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (For payment purpose, punned thickness of sand shall be measured).
7Supply & Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 95 sqmm 4 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. Note:- The cable may be passed through duct /pipes across runway/PTT etc.all necessary arrangement for passinng cables across runway /PTT through pippes /ducts to be made without any extra charges to contractor.
8Supply & Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 150 sqmm 4 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. Note:- The cable may be passed through duct /pipes across runway/PTT etc.all necessary arrangement for passinng cables across runway /PTT through pippes /ducts to be made without any extra charges to contractor.
9M&L Straight Through (Heat shrink) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor of Nominal Cross-Sectional area exc. 70 Sqmm but not exc. 120 Sqmm, 3½/4 Core and Testing, complete all as specified and as directed.
10M&L old size Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
11M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe, complete all as directed by the Engr-in-Charge at site.
12Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles, complete all as specified and as directed.
13M&L for Disconnection of existing Air Circuit Breakers (ACBs), 3 Pole/4 Pole,manually/electrically operated, fixed/draw-out type, AC 440 Volts,breaking capacity 50-100 kA, rated current 800-2000 Amps, form all incoming and outgoing electrical connections, checking serviceability of each components viz. ON/OFF button, CTs, tripping coil, shunt trip device, auxillary switches, locking arrangement, safety shutter, arc shield etc., replacement of defective lugs, thimbles etc., replacement of defective parts, thorough cleaning of ACB both internally and externally, reassembling of parts including reconnection of all incoming and outgoing electrical connections after repairs, testing and commissioning, complete all as specified and directed. (OEM :- L&T, ABB, C&S and Schneider)Notes:-(i) The work shall be carried out through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by the Garrison Engineer.(ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
14M&L for CT of capacity 400-800 Amps Fix and Draw-out type ACB complete all as per OEM's specifications, complete all as specified and directed.
15M&L for Lockable Trip Push Button (LTPB), complete all as per OEM's specifications, complete all as specified and directed.
16M&L for Lockable Trip Push Button Kit (3IC & 2 BC), complete all as per OEM's specifications, complete all as specified and directed.
17M&L for Locking of ACB in Isolated Position (LIP) type C, complete all as per OEM's specifications, complete all as specified and directed.
18M&L for Locking of ACB in any Position (LAP) type C, complete all as per OEM's specifications, complete all as specified and directed.
19M&L for Racking interlock type CC, complete all as per OEM's specifications, complete all as specified and directed.
20M&L for Racking Padlock Assembly, complete all as per OEM's specifications, complete all as specified and directed.
21M&L for Door Interlock, complete all as per OEM's specifications, complete all as specified and directed.
22M&L fot Mechanical operation counter, complete all as per OEM's specifications, complete all as specified and directed.
23M&L for Mounting Kit for Front mounted counter in repair, complete all as specified and directed.
24M&L for Shunt release, complete all as per OEM's specifications, complete all as specified and directed.
25M&L for under voltage release, complete all as per OEM's specifications, complete all as specified and directed.
26M&L for Earth fault Release, complete all as per OEM's specifications, complete all as specified and directed.
27M&L for vertical terminal adaptors for draw out ACB, complete all as per OEM's specifications, complete all as specified and directed.
28M&L for electronic timer adjustable type from 3 to 30 sec, Complete all as per OEM's specification, complete all as specified and directed.
29M&l for spring charging motor 110V/220VV AC/DC,Power rating 100-200watt speed 1400RPM for ACB, complete all as per OEM's specifiaction, complete all as specified and directed.
30S&F Galvanised Iron Pipe 100mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.
31M&L cement concrete PCC type C-2 (1 : 3 : 6) 40 mm graded stone aggregate for pole foundation including necessary form work and forming neat finish surfaces, complete all as specified and directed.
32M&L cement concrete PCC type C-2 (1 : 2 : 4) 12.5mm graded stone aggregate for copping of pole for existing/new pole including necessary form work and forming neat finish surfaces, complete all as specified and directed.
33M&L for LT Cable fault detection and its rectification by using Cable fault locator machine span length maximum 2km of cable size 35 to 150 sqmm all as specified and and directed by Engr-in-Charge. Note:-1. Suitable excavation and jointing kit will be measured and paid seperately.
34M&L for relaying heavy duty LT under ground cable of any sizes and types in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surface, complete all as specified & directed.
35Taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 150/120 /95Sq mm, 3 ½ &4core, complete all as specified and directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58391985
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Lt Cables Of Mafi Installations And Mafi Eqpt At Runway Pavement -Ii Under Ge (Af) Tezpur
Basic Detail
Tender No 8214/E8
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 05 Nov 2026
Submission Date 24 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 42 Lakhs
Tender Fee 500
EMD 84000
Exemption Available
Document List
5c010430-d64d-4364-96b0-770e1938b741.html
BOQ_894502.xls
tender8214.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

5c010430-d64d-4364-96b0-770e1938b741.html

xls

BOQ_894502.xls

pdf

tender8214.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender