Tender For Repair & Renovation Works Of Quarters At Primary Tier (Phc-Bedded & Bphcs/ Rhs) Health Facility Under Various Districts Of West Bengal ---Repair & Renovation Of Electrical Installation Work At Nurses Quarter At Bhangagarh Rh,Sankrail Block
Tender Overview
Project Description
Tender for Repair & Renovation Works Of Quarters At Primary Tier (Phc-Bedded & Bphcs/ Rhs) Health Facility Under Various Districts Of West Bengal ---Repair & Renovation Of Electrical Installation Work At Nurses Quarter At Bhangagarh Rh,Sankrail Block ,Jhargram.(Annexure A, Sl No. 22).
BOQ
| Sl. No. | Item Description |
| 1 | S & Fixing of 1 No 32A Rewirable Type Kit kat Fuse link on 2ft X 1.5ft hylam sheet thikness 2-3mm board with necessary nuts ,bolts washers etc as per direction of EIC [Make:-Havells] |
| 2 | Supply & Fixing 240 V 32A DP Steel Main Switches on angle with fuse on L&N [Make:-Havells/L&T/Siemens] |
| 3 | Supplying and fixing 16 way, Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(As per direction of EIC & Brand approved by EIC) |
| 4 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(As per direction of EIC & Brand approved by EIC) |
| 5 | 40 A DP |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 7 | Single Pole |
| 8 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. as per direction of EIC and brand approved by EIC |
| 9 | (Group C) |
| 10 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (On Board) |
| 11 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K, (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) LED Batten light 36 watt (System lumen efficacy ≥120 <135 lm/Watt) [As per direction of EIC and brand approved by EIC] |
| 12 | Supplying and fixing PVC batten/ angle holderincluding connections etc. as required. |
| 13 | Supply and fixing 9 Watt 825 lm LED bulb. [Make:- Philips/Havells/Crompton] |
| 14 | Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. |
| 15 | Supplying LED bulk head light fitting (Philips cat no.-WT202W LED6S NW PSU S2 PC/ CG cat no.- LBHE-10-CDL) |
| 16 | Providing and fixing circular/Hexagonal G.I. Box for ceiling fan clamps, of internal dia 140 mm, 73 mm height, top LID of 1.5 mm thick G.I. sheet with its top surface hacked for proper bonding, top LID shall be screwed into the G.I. box by means of 3.3 mm dia rounded screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shap as per standard drawing. |
| 17 | Supply, Installation, Testing and Commissioning of ceiling fan with blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. [As per direction of EIC and brand approved by EIC] |
| 18 | 1200mm, Sweep, 44W, 320 RPM, 1 Star. |
| 19 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(As per direction of EIC & Brand approved by EIC) |
| 20 | Installation, Testing and Commissioning of exhaust fan upto 450mm in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 21 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 22 | Supply & Delivery 9\\"(230mm), 1370 RPM, 40 Watt Heavy duty AC Exhaust fan incl. necy., all connection. [Make- EPC/Usha/Orient Electric] |
| 23 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required (As per direction of EIC and Brand approved by EIC) |
| 24 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 25 | Supplying and fixing 3 modules, GI box along with modular base & cover plate incl. Supplying and fixing 1 no. 16A modular switch & 1no. 16A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.for modular switches in recess etc. as required.(As per direction of EIC & Brand approved by EIC) |
| 26 | Supplying and fixing 2 modules, GI box along with modular base & cover plate incl. Supplying and fixing 16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.for modular switches in recess etc. as required.(As per direction of EIC & Brand approved by EIC) |
| 27 | Supplying and fixing 2 modules, GI box along with modular base & cover plate incl. Supplying and fixing 16A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.for modular switches in recess etc. as required.(As per direction of EIC & Brand approved by EIC) |
| 28 | Supply & Fixing 240 V, 25 A/27A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 29 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 30 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections. |
| 31 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 32 | 150 mm X 150 mm X 60 mm deep |
| 33 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (As per direction of EIC & Brand approved by EIC) |
| 34 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 35 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 36 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 37 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 38 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 39 | 1.5 sqmm |
| 40 | 2.5 sqmm |
| 41 | 4 sqmm |
| 42 | 6 sqmm |
| 43 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 44 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 45 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) (From Earth pit to earth Bus bar for body earthing) |
| 46 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 47 | N.B.1. Defect Liability period for this Project Work : 1 (One) Year.2. Standard Warrenty/ Extended Warrenty should be provided by the agency/ OEM as stated in the BOQ items.3. Make list for BOQ items has been attached separately. Bidders are requested to follow the Make list during execution.4. If found any refurbished or damaged products have been supplied during execution, penalty will be imposed anad security may be forfitted for that project work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline