Tender For Renovation Of Executive Hostel Building
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Nov 2026
8 days left
EMD
2.20 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Belagavi → Karnataka
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Executive Hostel Building
BOQ
| Sl. No. | Item Description |
| 1 | Renovation of Executive hostel building |
| 2 | Demolition, Dismentaling and Repair Work Dismantling & Removal of Wooden Doors & Window Dismantling & Removal of exisitng Wooden frame of Doors,Window and Ventilators. Removal of Door Shutters and Window Shutters including MS. Grill Bathroom Doors |
| 3 | Outside Windows |
| 4 | Outside Ventilators |
| 5 | Dismantling & Removal of Aluminium Partition, Doors & Window Dismantling & Removal of exisitng Aluminium framework of Partition , Doors / Windows including removal of glass panels and disposal of the sections to the area as per the instructions of Engineer incharge. |
| 6 | Removal and Demolision of Existing Wall Tiles (Dado) , Skirting and Granite Platform Removal and disposal of Bathroom floor tiles, Wall Tiles (Dado) , Skirting and Granite Platform including the demolision of Walls and supports provided, including the underlying mortar/adhesive layers, cleaning of the base surface, and proper collection and disposal of all debris. et. complete |
| 7 | Removal of Existing Sanitary Fittings Removal of Existing Sanitary Filltings , Concealed Pipelines , All downtake pipes including Kitchen sink etc complete. |
| 8 | Removal of Collapsible Gate |
| 9 | Civil Repair Work Repairing broken surfaces and damaged plaster surfaces around window/Ventilators sides, edges, and jambs after the removal of existing wooden/steel windows and pulling out of jamb chowkhats. The scope includes cutting out loose masonry/plaster patches in a proper regular shape, raking out joints, removing debris, preparing, cleaning, and pre-wetting the structural wall surface. The broken surfaces shall be rebuilt and finished true to line, level, and plumb using Cement Mortar 1:4 (1 cement : 4 fine/coarse sand) as directed. The work must include structural curing, watering, hacking of concrete surfaces if required, provisioning of all necessary tools, plants, equipment, and appropriate double-tier steel scaffolding. It also includes the systematic disposal of unserviceable material or rubbish to an approved dumping ground. Windows |
| 10 | Ventilators |
| 11 | Fixing and patching up damaged plaster surfaces (up to an area of 0.5 m² per patch) disrupted due to plumbing excavations, line alterations, or pipe leaks. The work includes cutting out the defective/damaged plaster to a clean, geometric shape, raking out structural joints to a minimum depth of 10 mm, brushing off loose material, thoroughly wetting the surface, and reapplying Cement Plaster 1:4 (1 cement : 4 fine sand) or 1:6 mix to match the thickness of the adjoining existing plaster. The finish must be rendered smooth using traditional floats, cured properly with water, and left ready for painting. For Kitchen 10 No's |
| 12 | For Bathrooms 10 No's |
| 13 | Water Proofing Providing and laying water proofing treatment in WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and labour as per the instructions of the Engineer- incharge. |
| 14 | Tile on Tile Flooring on Existing Mosaic Flooring Vitrified Tiles :Supply and Laying of 600X600 Vitrified floor tiles of approved colour with adhesive, tile on tile including grout filling, cleaning the joints with white cement and matching pigments for flooring as well as skirting etc. all complete as per direction of Engineer-in-charge. Basic rate for per sft is 60 rs. For Rooms and Kitchen |
| 15 | For Corridor and Common Rooms |
| 16 | For Toilet Floor ( with epoxy grout) |
| 17 | For Kitchen Wall Tiles (Dado) |
| 18 | For Toilet Wall Tiles ( Dado) |
| 19 | Concrete Pavers:Providing and Laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 20 | Granite : Providing and fixing 18 mm thick gang saw cut granite of Steel Grey shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms,vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels For Entrance Tread and Riser |
| 21 | For Kitchen Katta - Glossy Black Granite |
| 22 | For Threshold and window sills |
| 23 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge |
| 24 | Aluminium Works Providing and fixing powder-coated aluminum work (minimum thickness of powder coating 50 microns) consisting of standard extruded sections of approved make conforming to IS: 733 and IS: 1285, fixed in frames of windows, ventilators, and partitions. This basic item covers the core profiles (3-track frame, sash styles, interlocking rails, and glazing beads), structural assembly components (aluminum angle cleats), and mechanical fasteners (stainless steel rawl plugs, cadmium-plated machine screws, or C.P. brass sunk screws)Cost to include glazing in aluminum door, window, ventilator shutters, and partitions with thoughened float glass panes of 5 mm thickness etc. with neoprene / EPDM rubber gasket and Standard aluminium window mesh (mosquito/insect screen) typically features an 18 × 16 mesh count woven from corrosion-resistant aluminium-magnesium alloy complete as per architectural drawings and directions of the Engineer-in-Charge. Sliding Windows 2.0mx1.4m |
| 25 | Sliding Window 1.0mx 0.6m |
| 26 | For Front Fixed Partition with necessary accessories and filling and stickering (12mm Tuffened Glass) |
| 27 | Main Door with Frame Tuffened glass and necessary fitting like Door closure etc.Size:1.8mx2.1.m (Rs.5300 sq/ft) |
| 28 | M S works Grill for Windows: Providing and fixing at site M.S. grills of required pattern to be fixed in brick wall to be grouted including concreting work, frames of windows etc. with M.S. flats, square or round bars etc. including 2 coats of steel primer, and two coats of approved shade of synthetic enamel, the cost shall include all labour, materials, contingencies etc complete. Windows 2.0mx1.4m |
| 29 | Ventilator 1.0mx 0.6m |
| 30 | M S Railing : Providing and fixing M S Railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fixing the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories etc., of required size, on the top of the floor or the sides of waist slab/Treads with suitable arrangement including 2 coats of steel primer, and two coats of approved shade of synthetic enamel, the cost shall include all labour, materials, contingenciesetc complete.( Use of existing Grill to be considered)- Ground Floor not required as per approval of Engineer-in-charge. (Area of Railing above finished floor level shall be measured). |
| 31 | Toilet Doors WPC Frame Providing and fixing factory made single extruded WPC (Wood Polymer Composite) Frames/Chowkhat of size 80 x 50mm comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (Rates to include all hardware inclusive of M.S hold fast/lugs or SS dash fasteners). |
| 32 | WPC Shutters Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)-25 mm thick |
| 33 | Painting Enamel Paint Removing, scrapping & cleaning the existing metal / wood surface. Enamel paint of approved shade shall be applied in minimum 2coats (finishing paint) including scaffolding, cleaning the floors, fittings, furniture and glass complete For wooden surface ( Doors and Windows) |
| 34 | For MS Grills |
| 35 | Interior Emulsion Paint Providing & applying Emulsion paint of Berger / Asian Paints/ ICI Dulux in minimum 2 coats including scrapping, opening of existing cracks, filling up of “V” cracks with cement based putty to required depths, making good weak plastered/ unplastered surfaces with cement plaster wherever required. Item to include Putty, primer & making good existing surface to receive new paint including cleaning on completion of painting work etc. complete in all respects. |
| 36 | Exterior Emulsion Paint: Remove all loose, flaking, or peeling paint, blistered areas, dust, algae, fungus, moss, and efflorescence salts using wire brushes, steel scrapers, or sandpaper. Cut out major cracks or uneven patches in V-shapes, clean them, and fill them using cement mortar (1:3) or approved waterproof putty/plaster touch-ups. Let the repairs dry thoroughly. Apply one uniform coat of exterior-grade water-based or solvent-based wall primer to seal porous masonry surfaces and improve paint adhesion on repair work. Apply two final coats of high-performance exterior emulsion (such as 100% acrylic weatherproof formulations . (Make : Berger , Birla Opus , Asian ) |
| 37 | Providing and fixing white vitreous china extended Floor mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete and labour as per the instructions of the Engineer-incharge. |
| 38 | Supply of Wash basin accessories, Size-560x415x200mm, and labour as per the instructions of the Engineer-incharge. (Make : Hindware,Parryware,Bell) |
| 39 | Supply & Fixing of pillar cock for wash basin and labour charge as per the instructions of the Engineer-incharge. |
| 40 | Supply & fixing of Waste coupling and labour charge as per the instructions of the Engineer-incharge. |
| 41 | Supply & Fixing soap dish and labour charge as per the instructions of the Engineer-incharge.(China Clay) |
| 42 | Supply & Fixing of Towel Ring and labour charge as per the instructions of the Engineer-incharge. |
| 43 | Supply & Fixing Double coat hook and labour charge as per the instructions of the Engineer-incharge. |
| 44 | Supply & Fixing of towel rail 24'' and labour charge as per the instructions of the Engineer- incharge. |
| 45 | Supply & Fixing of Bibcock cum Health Faucet with 1m long tube and wall hook and labour charge as per the instructions of the Engineer-incharge. |
| 46 | Supply & Fixing of Angular stopcock with wall flange and labour charge as per the instructions of the Engineer-incharge. |
| 47 | Supply & Fixing of Bottle Trap and labour charge as per the instructions of the Engineer-incharge. |
| 48 | Supply & Fixing of Wall Mixer with provision for overhead shower and 115mm long bend pipe with wall flange and labour charge as per the instructions of the Engineer-incharge. |
| 49 | Supply & Fixing of Rose shower with revolving ball joint & 180 mm long shower |
| 50 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 51 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes. |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. oncealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes. |
| 54 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.-Internal workExposed on wall 25 mm nominal dia Pipes |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.-Internal workExposed on wall 32 mm nominal dia Pipes |
| 56 | Providing and fixing Grade 304 (18/8) Stainless Steel Kitchen Sink satin/brushed finish of approved brand and manufacture, conforming to IS: 13983 [or equivalent local standard]. The unit shall be a single bowl without drainboard of overall size 20\\"x17\\"] and bowl depth 8\\". The underside of the bowl must be fully treated with a sound-dampening asphaltic compound/rubber pads and wrapped in an anti-condensation coating. The sink shall be fixed under/over the granite countertop filled seamlessly with premium anti-fungal, food-grade silicone sealant to ensure a 100% waterproof joint. Including Swan neck tap and Drain pipe . |
| 57 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with PVC solvent cement and the cost of cutting chases and making good the same using CC 1:3:6 including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.50mm PVC pipes of 6Kg/cm2 |
| 58 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with PVC solvent cement and the cost of cutting chases and making good the same using CC 1:3:6 including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.75mm PVC pipes of 6Kg/cm2 |
| 59 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with PVC solvent cement and the cost of cutting chases and making good the same using CC 1:3:6 including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.110mm PVC pipes of 6Kg/cm2 |
| 60 | Providing and fixing PVC pipes,including cost of pipes, specials, labour, jointing of pipes & fittings with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 140mm PVC pipes of 6Kg/cm2 |
| 61 | Providing and Fixing PVC Nahani trap and SS drain Cover of 150mm dia and thickness of 1.25mm approved make conforming to ISI specifications (Rate is inclusive of cost of materilas and fixtures and conveyance of materials to work spot) |
| 62 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 63 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500x700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 64 | PVC Conduit Supplying heavy gauge PVC electrical Conduit Pipe confirming to IS 9537 as below given size, bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick |
| 65 | 25 mm dia 2 mm thick |
| 66 | 40 mm dia 2.5 mm thick |
| 67 | 50 mm dia 2.5 mm thick |
| 68 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12\\" x 12\\" x 3\\" (300 x 300 x 76 mm) |
| 69 | Extra for Groove cutting in brickwall /CC floor to the suitable depth for concealing of Conduit / Gipipe and plastering, finishing upto wall surface complete upto 50 mm conduit in brick wall |
| 70 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm |
| 71 | Supplying PVC flexible conduit pipe .25.. Mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamp edusing heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25 mm |
| 72 | Supplying and wiring adopting loop system in PVC Conduit / casing capping using 3x1.5 /3x2.5Sqmm/3x4sqmm (Phase & Neutral and Earthwire FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood / PVC roundblock. complete for each outlet. Primary point |
| 73 | Secondary point |
| 74 | Two way Switch point |
| 75 | Supply of wires for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2 |
| 76 | 2.5 mm2 |
| 77 | 4 mm2 |
| 78 | 6 mm2 |
| 79 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 2 Way |
| 80 | 4 Way |
| 81 | 6 Way |
| 82 | 8 Way |
| 83 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal /PVC box. 2 Module |
| 84 | 4 Module |
| 85 | 6 Module |
| 86 | 8 Module |
| 87 | Supplying and fixing and wiring of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A/230VAC One Way Switch |
| 88 | 6A/230VAC Two Way Switch |
| 89 | 6A Three Way socket,5 /6 A230VAC |
| 90 | Stepped Fan Regulator Two Module |
| 91 | 16 A one way switch |
| 92 | 6A/230VAC Bell Push switch |
| 93 | 6/16A Universal Socket,230 VAC |
| 94 | TV/Telephone Socket(both Including 2 way) |
| 95 | Supplying 4 mm thick white plastic plate and covering for junction boxes of size......mmc onduit using necessary machines crews 80/90 mm |
| 96 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20\\" x 20\\" x 2.5\\" |
| 97 | Supplying & fixing and commissioning RCCB (residual current circuit breaker) 50 A 230VAC DP RCCB 30 mA for shock and fi e protection of din rail mount of Home and Industrial safety (A9N16208) |
| 98 | Supplying & fixing and commissioning miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 63A DP |
| 99 | 50 A DP |
| 100 | 25 A SP |
| 101 | 10A SP |
| 102 | Supplying and fixing and commissioning regular MCB distribution boards-8 way on wall / wood board / flush mounting using required clamps, bolts, nuts etc., for fixing suitable type capacity 50 amp RLCB -DP-1no,50 amps DP MCB-1 No, 40amp SP MCB-2No,10 A MCB- 2 No 230V AC single door with powder coated painting Made out of 14SWG. |
| 103 | Supplying exhaust fan of 1440 RPM of 300mm (12\\") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. |
| 104 | Supplying of Ceiling Fan of 230 VAC . 48\\" Sweep 5 Star (1200 mm 4 blade)370 rpm |
| 105 | 24\\" Sweep 5 Star (600 mm 4 blade),370 |
| 106 | Supplying 15 litres capacity vertical/horizontal type wall mounting Electrical water heater of 5 star rating of make V gaurd/Havells or any standard brand after approval by Electrical Incharge of HLL.with 22 SWG copper/SS sheetmetal inner Container tinned inside and anticorrosive paint outside and 20 SWGM.S. sheetmetal outercover filled with glasswool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with an eonindicator fitted with 20A capacity 25to85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. |
| 107 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair |
| 108 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. |
| 109 | Supplying & fixing retrofittype-PL-LEDLamp..8-9....W LED linear source with CCT 6500 degree K,CRI>70%. efficacy> 80 lumen per W, life >25000 burning hours and Compliance to IS10322/IEC60598, LM79&LM80. The LED are driven by H Felectronic driver integrated in the system, with PF>0.95, power loss should <5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD lessthan 20%, Life as per LM79. The operating inputvoltage shouldbe between 130 to 275V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED round type ceiling mounted surface type8-9 W,230 VAC |
| 110 | Supplying of...4.. feet-PVC Batten with integrated LED tube.20-22...W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI>80. PowerInput:220-240V @50/60Hz & Powerfactor >0.9 along with CE approved.2years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W |
| 111 | Supply of round / square recess/surface mounted rolling type LED Down light with......W GU10LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivellinguni to faluminium die caste yeball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI>80. PowerInput:220-240V @ 50/60Hz & Powerfactor >0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 15-18W,230 VAC indoor |
| 112 | LED square flood light 100W,230 VAC (Outdoor) |
| 113 | Supplying and fixing one of 230V bell or buzzer and a flush type bellpush with gangbox fixed on necessary wooden or rawl plugs using NF screws. |
| 114 | The construction of earthing pit as per IS :3043:1987 of copper plate 600x600x3 mm as per annexure .and connect to Electrical distribution board by 25mm X3mm copper double strip in under ground from pit to MCB DB.Note: The annexure and drawing for Earthpit enclosed. |
| 115 | Electrical grade copper strip of size 25x3mm laying in underground/wall by necessary support and connect to earthing pit and MCBDB. |
| 116 | Supply and fixing of Lightning arrestor of 1000mm-1200mm,25mm outer dia of hollow pipe and thickness is 2mm with pure electrolytic grade copper with 5 spike(1 central spike with surrounding 4 spikes at end of tube and connect to existing exrthpit by coper strip of 25x5 mm from copper tube to rearthing pit around 30 feet height. |
| 117 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook madeout of 15mm dia MS rod, with 5A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired |
| 118 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5A, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. |
| 119 | Erection charges for fixing a 15 litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600 mm back plate and wiring complete with 15A 230VAC 3 pin top. |
| 120 | Fixing all types and all capacities of LED Light fittings indoor on the wall/ceiling/rafters/girders with necessary supporting frame, using 2310.0076\\" twin twisted PVC insulated wires, required Nos of round blocks and clamps. |
| 121 | Dismantling of Existing (old) Electrical Conduits and Cables Switch Boards and Complete Old Wiring form wall surface and ceiling surface. |
| 122 | Supplying and fixing and commissioning regular MCB distribution boards on wall / ood board / flush mounting using required clamps, bolts, nuts etc., with provision of 2 Rows (Each 10 Nos DP MCB MCB's Double pole 63 Ams 230sVolt AC ngle door with powder coated painting Made out of 14SWG |
| 123 | 125amps rating 4 Nos x 600mm x50mmX10 mm suitabl elength Aluminium Strips |
| 124 | Supply and fixing of 250 amps rating SFU with S enclosure , TP&N 415 VAC Model SK 90489with fuse 125 amps for RYB and N uetral link for main Incomer and out going to Bus bar DB . |
| 125 | The wooden board for fixing 18 nos of digital ennrgy meter board at Incomer supply at existing meter board palce with required accessories for fixing and energy meters to be mounted on this board. |
| 126 | Energy meter-Single phase LCD energy meter ,2 wire, 230 volt, 05- to 30A,50Hz,3200imp/kwh,class-1 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender