Tender For repair maintenance Of electrical installation & Fans I/C Compound/Street Lighting, Fire Fighting, Water Purifier Cum Water Cooler And Air Conditioner At Distt. Social Welfare Office (Nw-I & Ii), Indra Nagar, Azadpur, Delhi-33. During The Y
Tender Overview
Project Description
Tender for repair maintenance Of electrical installation & Fans I/C Compound/Street Lighting, Fire Fighting, Water Purifier Cum Water Cooler And Air Conditioner At Distt. Social Welfare Office (Nw-I & Ii), Indra Nagar, Azadpur, Delhi-33. During The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | SH-I EI WorkOperation and maintenance of electrical and mechanical installations at Distt. Social Welfare Office (NW-I & II), Indra Nagar, Azadpur on all working days including sunday and holidays or as per directions of Engineer-in-charge, terms and conditions etc. as required for operation and maintenance of EI and Fans,Pump sets etc.(1) Wireman cum Pump Operator - 3 Nos. (One in each shift : 6 AM to 2 PM , 2 PM to 10 PM and 10 PM to 6 AM.)(2) Khallasi - 1 No. ( 9 AM to 5 PM in General shift) |
| 2 | Comprehensive, running maintenance & Servicing of following capacity Window / Split installed under Distt. Social Welfare Office (NW-I & II) i/c replacement all defective i.e. blower motor, compressor, Gas Charging, PCB, remote, Plug Top, Starting Capacitor, Running Capacitor, Starting Relay, Thermostat, Propeller Fan, Over load Relay i/c condenser unit, evaporative unit charging of refrigerant gas in case of leakage i/c refrigerant gas pipe with insulation, lead wire, plug Top, etc complete as per terms and conditions attached:-Window type AC/ Split type AC of 1.5TR/2.0 TR capacity. (14 Nos. AC for 8 Months = 112 Jobs) |
| 3 | Water coolers of capacities 100/150 ltr (2 Nos. for 12 Months-24 Jobs) |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C |
| 5 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group-C |
| 6 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 8 | 8 way , Double door |
| 9 | Lifting of existing submersible bore well / open well 3HP to 10 HP capacity Pump set from the bore well with chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 10 | Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with chain pulley block and tripod stand i/c cartage charge pump set from work shop to site credit of old dismantle etc, as reqd. |
| 11 | Repairing of Submersible/monobloc Pumpset of following capacity i/c replacement of mechanical seal TC/TC upper, mechanical seal TC/TC lower, ball bearing, 'O' Ring, stamping repairing, including dismantling, assembling, commissioning and testing the same on load after making electric connections at site i/c site visit by Engineer and to & fro from site to workshop & back to site etc. complete with credit of dismantle etc as required.3 HP |
| 12 | Rewinding of following capacity Pumps, 3 phase multistage submersible / monoblock-submersible Pump-set with suitable size water proof copper conductor wire and dismantling the existing burnt wire, reassembling the pump and to & fro from site to workshop & back to site, etc. i/c buy back of dismantle materials i/c connection, testing etc as reqd.3 HP |
| 13 | SH-II (Supply of materials) Note:- No labour is considered for fixing of these items5/6 A switch (Modular type) |
| 14 | 15/16 A switch (Modular type) |
| 15 | 3 pin 5/6 A socket outlet (Modular type) |
| 16 | Bell push (Modular type) |
| 17 | Telephone socket outlet |
| 18 | 6 pin 15/16 A socket outlet (Modular type) |
| 19 | Stepped type Modular Fan regulator (2 module) |
| 20 | 1 or 2 Module Modular base & Cover plate |
| 21 | 3 Module Modular base & Cover plate |
| 22 | 6 Module Modular base & Cover plate |
| 23 | 8 Module Modular base & Cover plate |
| 24 | 12 Module Modular base & Cover plate |
| 25 | 5A to 32Amp SP MCB 10kA rating \\"C\\" Curve |
| 26 | 3 pole MCCB, 100A, 16kA (Ics = 100% Icu) |
| 27 | 3 pole MCCB, 200A, 25kA (Ics = 100% Icu) |
| 28 | 1.5 sq. mm sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 29 | 4 sq. mm sq. mm sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 30 | 6 sq. mm sq. mm sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 31 | 18- 22 watt 4 feet Indoor commercial LED batten fitting (System lumen efficacy ≥105 <120 lm/Watt) with Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm). |
| 32 | 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor with remote or electronic regulator. |
| 33 | 40 watt Panel Down light 2x2 ft. LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 34 | 18 watt LED Down lighter (SMD Type) (System lumen efficacy ≥120 <135 lm/Watt ) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 35 | 100 watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) |
| 36 | 40/63 Amp, SPN MCB 10kA rating \\"C\\" Curve |
| 37 | 40/63 Amp TP MCB 10 kA rating \\"C\\" Curve |
| 38 | Heavy duty exhaust fan of 300 mm sweep 900 rpm. |
| 39 | Heavy duty exhaust fan of 380 mm sweep 1400 rpm. |
| 40 | 400 mm PVC body wall mounted bracket fan sweep with air delivery not less than 80 cm and of 1300 rpm. |
| 41 | 35-40 Watt LED post top lantern fitting having die cast aluminium body with minimum 100 lumens per watt. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender