Housing Urban and Rular Development Government Departments Closing in 12 days TDR #58389442

Tender For Remaining Urgent Electrical Work In Jannayak Chandrashekhar University Ballia.

Issued by Government Departments · Azamgarh, Uttar Pradesh
Tender Value
85 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
12 days left
EMD
6.25 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Azamgarh → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Remaining Urgent Electrical Work In Jannayak Chandrashekhar University Ballia.

BOQ

Name of Work:- जननायक चन्द्रशेखर विश्वविद्यालय बलिया में अवशेष अति आवश्यक विद्युत कार्य।
Sl. No. Item Description
1Supplying, installation, testing and commissioning of 2000 KVA capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sq.mm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and as per CPWD specificationscomplete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 40 0C for oil and 45 0C for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) airtemperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent k) One filter valve on the upper side of the tank Unidirectional flat rollers m) Inspection hole n) HV side neutral grounding strip(where one of the HV bushing terminal is connected to earth); o) Buchholz relay. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug . bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. With Mineral Oil Filed (5 Years Warranty) DSR No. 24.6.4
2Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cables 1100V grade. At a depth of 750 mm below ground level over a cushion 75mm thick sand all aroundand provide with burnt bricks on side and on top complete in all respect including excavationand refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. a 10 sq mm 2 core SOR No. 10.1.2
395 sq mm3-1/2 core SOR No. 20.1.14
4120 sq mm3-1/2 core SOR No. 20.1.15
5150 sq mm3-1/2 core SOR No. 20.1.16
6300 sq mm 3-1/2 core SOR No. 20.1.19
7Supplying and making end termination with brass compression gland and aluminium lugs for following size of insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 10 sq mm 2 core DSR No. 11.1.2
895 sq mm3-1/2 core DSR No. 11.1.24
9120 sq mm3-1/2 core DSR No. 11.1.25
10150 sq mm3-1/2 core DSR No. 11.1.26
11300 sq mm 3-1/2 core DSR No. 11.1.30
12Earthing with G.I. earth Pipe 4.5 Meter long 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. DSR No. 5.2
13Providing and fixing 25 mm x 5mm G.I. strip DSR No. 5.15
14Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. DSR No. 5.6
15Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. DSR No. 5.14
16Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I.pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. DSR No. 5.12
17Supplying, installation, Testing & Commissioning of 90 watt LED Street light fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC Com[lete in all respect DSR No. 8.12.14
18Servicing of Tarrace pump 5 HP
19Testing & Commisioning of hydrant system of library, acadmic building, Admin Block by alredy installed Tararce pump.
20Testing & Commisioning of alrady installed 11 KV Elecctric sub station
21Testing & Commisioning of already installed 500 KVA DG Set including filtter, lubricant Oil and Disel etc.
22Making RCC foundation with M-20 grade concreat 4m x 3m x 0.3m
23Fancing around the transfoemer 4 m lenth x 3 m width x 3 m hight from MS angle (Size 40 mm x 40 mm x 5mm) including all the matereal, welding etc complete in all respect.
24Suplly and laying of 150 mm G.I. pipe DSR No. 27.8.8
25Suplly and laying of 100 mm G.I. pipe DSR No. 27.8.7 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58389442
AUTHORITY Government Departments
TENDER VALUE 85 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Remaining Urgent Electrical Work In Jannayak Chandrashekhar University Ballia.
Basic Detail
Tender No 1730/Nivida Suchana (Azm Zone) GKPCircle-EM/2026-27 Date 24.10.2026
Bidding Type Tender
Location
City Azamgarh
State Uttar Pradesh
Key Dates
Publish Date 05 Nov 2026
Submission Date 18 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value 85 Lakhs
Tender Fee 2354
EMD 6.25 Lakhs
Exemption Available
Document List
a59e762f-f6a1-49a2-9320-f1b49906195d.html
BalliaT2.pdf
BOQ_2284838.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

a59e762f-f6a1-49a2-9320-f1b49906195d.html

pdf

BalliaT2.pdf

xls

BOQ_2284838.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender