Project Description
Tender for Construction Of Anganwadi Buildingat anganwadi center Code 33627030312 Ward No 5 Sathankulam Colony 1 In Sathankulam Town Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in all classes of soils and sub soil to full depth except in hard rock requiring blasting but inclusive of shoring strutting if required for the sides of foundation |
| 2 | Plain Cement Concrete 1:4:8 (one part of cement, five part of Crushed Stone Sand (M- Sand) and Ten part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 3 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\\" X 43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 4 | Supplying and Fabricating and placing in position MS Steel or ribbed for steel for all reinforced cement concrete works as per the design given including cost of steel and binding wire all floors etc., complete complying with standard specification. |
| 5 | Supplying and Erection centering for sides and soffiots including necessary supports and strutting as directed by the departmental officers. Rate for 10m2 for the following items (RCC floor slab, roff slab, Rectangular / Square, Tee / Ell beams. |
| 6 | a) Plain Surface Below GL |
| 7 | b)Square Column |
| 8 | C) Lintel & Roof Slab Beam |
| 9 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - |
| 10 | Plastering with cement mortar 1:3 (One part of Cement and Three part of M Sand ( 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 11 | Plastering in CM 1:5 mix, 12mm thick over the cement concrete for floor finish including curing etc., complete complying with standard specifications and as directed by the departmental officers |
| 12 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part ofM. Sand ), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 13 | Dadooing walls with Glazed tiles of sizes 300mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of M. Sand) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 14 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum |
| 15 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 16 | Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 17 | Painting Two coats of new iron works such as steel doors,windows, ventilators, window bar, balustrades etc., with best approved first quality of synthetic enamel paint of approved colour over the existing priming coats etc., complete complying |
| 18 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 19 | Flooring with Cuddapah slabs of 40mm thick over a base mortar in CM 1:3 (One Cement and Three Plastering Sand (P - Sand)) 20 mm thick and pointed with cement mortar 1:3 ( one cement and three M.sand) usimg Black oxide complying with standard specification (P & D data 53) |
| 20 | Cost and supply of RCC Jolly |
| 21 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \\"U\\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 22 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 23 | Conducting Geo-Physical survey including conveyance the instrument etc., complete |
| 24 | Drilling of 150mm dia vertical bore well upto the recommended depth etc., complete |
| 25 | Supply and inserting of 6 Ksc PVC casing pipe etc., complete (150mm CS) |
| 26 | Supply and delivery and fixing of HDPE tank including loading and unloading, transportation fixing and necessary GI Pipe and specials for pipe connection works including cutting, threading and fixing charges as directed by depart-mental officers etc., complete |
| 27 | Supply and delivery of single-phase pump set with motor as per ISI 20 lpm x 80 head with out panel board consist of following. |
| 28 | Supply and delivery of single-phase panel board with 2 level guard and auto start (2 HP Starter) |
| 29 | Supply and delivery of PVC Insulated and Sheathed 3 core flat type 2.5 sq.mm copper cable conforming to IS 694/1990 |
| 30 | Labour charges for erection of pump set in the deep bore well including connection of submersible cable etc. |
| 31 | SupplyandfixingofTNEBmeterboardsuitablefor32Athreephaseserviceconnectionwith3Nos.32Afuseunit(500V)32Aneutrallinkandearthlink(1\\"x1/8\\"copperflat)onTWplankofsize600mmx450mmx19mmwithsupportingTWreepersof1\\"thickaneithersidewithpaintingwithsuitableboltandnutsforfixingtheTWplankonwallwithearthconnectionandinterconnectionwith7/20PVCinsulatedcopperwirefromEBmetertofuseunitwith1No40Amp30MA Four Pole RCD / RCCB (Lower End) with suitable necessary connection |
| 32 | Wiringwith2x1.5sq.mm.PVCinsulatedsinglecoreunsheathedFRLScopperconductorcableof1100VgradeinsuitableheavygaugeMSconduitpipeonwallandceilingwithMSaccessorieswithMSswitchBoxand5AFTswitchwithpaintingofsuitablecolourcontinuousearthwireconnectionof1.5sq.mmcopperwireforlightpoint/fanpoint(forelectronic regulator) SD 1 ( Ele 2025-2026 |
| 33 | Wiringwith2x1.5sq.mm.PVCinsulatedsinglecoreunsheathedFRLScopperconductorcableof1100VgradeinsuitableheavygaugeMSconduitpipeonwallandceilingwithMSaccessorieswith150mmx100mmx75mmMSswitchboxfor5A3pinnoninterlockingflushtypeCSplugwfthpaintingofsuitablecolourwithcontinuousearthwireconnection of 1.5 sq.mm copper wire for open plug point SD 10 |
| 34 | Supplyandfixingof4FeetLED18WFittingwithLED18Wtube(LowerEnd)completewithTWroundblockson wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting SD 440 |
| 35 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp (SD112) |
| 36 | Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall SD 115 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST