Public Administrative Department Government Departments Closing in 11 days TDR #58387226

Tender For Construction Of Major Renovation Works At Keshab Deka Memorial Lps (18010211702), District Kokrajhar Under Dharti Aaba Janjatiya Gram Utkarsh Abhiyan (Dajgua) Tribal Affairs (Plain) For The Financial Year 2026-27

Issued by Government Departments · Kokrajhar, Assam
Tender Value
75 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
11 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kokrajhar → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Major Renovation Works At Keshab Deka Memorial Lps (18010211702), District Kokrajhar Under Dharti Aaba Janjatiya Gram Utkarsh Abhiyan (Dajgua) Tribal Affairs (Plain) For The Financial Year 2026-27

BOQ

Name of Work:- Construction of Major Renovation works at KESHAB DEKA MEMORIAL LPS (18010211702), District Kokrajhar under Dharti Aaba Janjatiya Gram Utkarsh Abhiyan (DAJGUA) Tribal Affairs (Plain) for the Financial Year 2026-27
Sl. No. Item Description
1Construction of Kitchen2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil
216.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
34.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived fromnatural sources : 6 graded stone aggregate 20 mmnominal size derived from natural sources)
45.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
55.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.1 Foundations, footings, bases of columns, etc. for massconcrete
65.1 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
75.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers
85.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
95.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
105.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
115.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
126.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
136.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
145.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
155.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
1613.5 15 mm cement plaster :13.5.2 1:6 (1 cement : 6 coarse sand)
1711.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
1813.43 Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
1913.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
204.10 Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources)
2112.65 Providing & fixing at all heights, levels and locations colourfinish Aluminium alloy roofing sheets of alloy IS designation31500, temper Hx8 conforming to IS 737 and dimensions asper IS code 2676 with characteristics of good formability andcorrosion resistance. The profile sheets shall be fixed to trussmembers in slope or required pitch or curvature with Hexcap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive oflabour, scaffolding, T&P and sundries etc. complete as perdirections of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately).12.65.1 0.56 mm, Aluminium Color coated troughed profilewith center to center pitch of 200 mm, depth of32 mm, overall profile width1092 mm, cover width1000mm.
2210.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes
2310.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat ofapproved steel primer.10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces
249.72 Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete :9.72.1 125x85x5.5 mm (heavy type)
259.92 Providing and fixing chromium plated brass handles with necessaryscrews etc. complete:9.92.3 75 mm
262.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
2716.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
284.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth.
29Repairing of office Room15.28 Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet
3014.15 Renewing wooden battens in roofs, including making good the holesin wall and painting with oil type wood preservative of approved brandand manufacture complete, including removal of rubbish to thedumping ground, all complete as per direction of Engineer-in-Charge.14.15.1 Sal wood battens
3112.65 Providing & fixing at all heights, levels and locations colourfinish Aluminium alloy roofing sheets of alloy IS designation31500, temper Hx8 conforming to IS 737 and dimensions asper IS code 2676 with characteristics of good formability andcorrosion resistance. The profile sheets shall be fixed to trussmembers in slope or required pitch or curvature with Hexcap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive oflabour, scaffolding, T&P and sundries etc. complete as perdirections of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately)12.65.5 0.71mm Aluminium color coated profile with centerto center pitch of 175 mm, depth of 46mm, topcrest width of 41mm, bottom valley width of80mm, overall profile width of 1144mm, cover width1050mm.
3212.66 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISOdesignation)] For color, coating shall be 5-7 microns epoxyprimer on both sides of the sheet and polyester top coat 15-18microns, using self drilling/tapping SS screws of size 6 x 50mmwith 3mm thick EPDM seal and SS plain washer complete :12.66.1 Precoated/mill finish aluminium Ridges plain(500- 600mm)
338.25 Providing and fixing 2nd class teak wood plain lining tongued and grooved,including wooden plugs complete with necessary screws and primingcoat on unexposed surface.8.25.2 25 mm thick
3413.50 Applying priming coat:13.50.2 With ready mixed aluminium primer of approved brandand manufacture on resinous wood and plywood
3511.41 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete.11.41.2 Size of Tile 600x600 mm
362.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete
3716.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
3811.5 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete.
3915.2 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix)
405.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
415.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers
425.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
435.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
445.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
4512.45 Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of anglehanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flangesof 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mmthick 27 mm high having flanges of 20 mm and 30 mm long, theperimeter of ceiling fixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25mm long dry wall screws @ 230 mminterval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finishof tapered and square edges of the board with recommended jointingcompound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification andalso including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction ofthe Engineer in Charge but excluding the cost of painting with :12.45.3 12.5 mm thick tapered edge gypsum moisture resistantboard
4614.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area2.5 sq.meters and under, including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the wallscomplete, including disposal of rubbish to the dumping ground, allcomplete as per direction of Engineer-in-Charge.14.1.2 With cement mortar 1:4 (1cement: 4 coarse sand)
4711.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
4813.91 Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete.
4913.43 Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
5013.82 Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required,to achieve even shade and colour.13.82.2 Two coats
5114.4 Making the opening in brick masonry including dismantling in flooror walls by cutting masonry and making good the damages to walls,flooring and jambs complete, to match existing surface i/c disposalof mulba/ rubbish to the nearest municipal dumping ground, allcomplete as per direction of Engineer-in-Charge.14.4.1 For door/ window/ clerestory window
529.1 Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately).9.1.2 Sal wood
539.5 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters
5413.48 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :13.48.2 Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture
559.72 Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete :9.72.1 125x85x5.5 mm (heavy type)
569.92 Providing and fixing chromium plated brass handles with necessaryscrews etc. complete:9.92.3 75 mm
579.63 Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : (copper oxidizedas per IS: 1378)9.63.1 250x10 mm
5815.2 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix)
594.17A Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 manufactured sand derived from Recycled ConcreteAggregate (RCA) : 6 graded stone aggregate 20 mm nominalsize (Recycled Concrete Aggregate (RCA) over 75mm thick bedof dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessaryexcavation, levelling & dressing & finishing the top smooth
60Repairing of Class Room building15.28 Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet
6114.15 Renewing wooden battens in roofs, including making good the holesin wall and painting with oil type wood preservative of approved brandand manufacture complete, including removal of rubbish to thedumping ground, all complete as per direction of Engineer-in-Charge.14.15.1 Sal wood battens
6212.65 Providing & fixing at all heights, levels and locations colourfinish Aluminium alloy roofing sheets of alloy IS designation31500, temper Hx8 conforming to IS 737 and dimensions asper IS code 2676 with characteristics of good formability andcorrosion resistance. The profile sheets shall be fixed to trussmembers in slope or required pitch or curvature with Hexcap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive oflabour, scaffolding, T&P and sundries etc. complete as perdirections of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately)12.65.5 0.71mm Aluminium color coated profile with centerto center pitch of 175 mm, depth of 46mm, topcrest width of 41mm, bottom valley width of80mm, overall profile width of 1144mm, cover width1050mm.
6312.66 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISOdesignation)] For color, coating shall be 5-7 microns epoxyprimer on both sides of the sheet and polyester top coat 15-18microns, using self drilling/tapping SS screws of size 6 x 50mmwith 3mm thick EPDM seal and SS plain washer complete :12.66.1 Precoated/mill finish aluminium Ridges plain(500- 600mm)
648.25 Providing and fixing 2nd class teak wood plain lining tongued and grooved,including wooden plugs complete with necessary screws and primingcoat on unexposed surface.8.25.2 25 mm thick
6513.50 Applying priming coat:13.50.2 With ready mixed aluminium primer of approved brandand manufacture on resinous wood and plywood
6615.2 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix)
672.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
6816.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
6911.5 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete.
7015.2 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix)
715.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
725.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers
735.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
745.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
755.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
766.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
7712.45 Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dashfastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flangeof cleat fixed to the angle hangers of 25x10x0.50 mm of requiredlength with nuts & bolts of required size and other end of anglehanger fixed with intermediate G.I. channels 45x15x0.9 mm runningat the spacing of 1200 mm centre to centre, to which the ceilingsection 0.5 mm thick bottom wedge of 80 mm with tapered flangesof 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mmthick 27 mm high having flanges of 20 mm and 30 mm long, theperimeter of ceiling fixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25mm long dry wall screws @ 230 mminterval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finishof tapered and square edges of the board with recommended jointingcompound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification andalso including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction ofthe Engineer in Charge but excluding the cost of painting with :12.45.3 12.5 mm thick tapered edge gypsum moisture resistantboard
7814.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area2.5 sq.meters and under, including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the wallscomplete, including disposal of rubbish to the dumping ground, allcomplete as per direction of Engineer-in-Charge.14.1.2 With cement mortar 1:4 (1cement: 4 coarse sand)
7911.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
8013.91 Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete.
8113.43 Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
8213.82 Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required,to achieve even shade and colour.13.82.2 Two coats
8314.4 Making the opening in brick masonry including dismantling in flooror walls by cutting masonry and making good the damages to walls,flooring and jambs complete, to match existing surface i/c disposalof mulba/ rubbish to the nearest municipal dumping ground, allcomplete as per direction of Engineer-in-Charge.14.4.1 For door/ window/ clerestory window
849.1 Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately).9.1.2 Sal wood
859.5 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters
8613.48 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :13.48.2 Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture
879.72 Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete :9.72.1 125x85x5.5 mm (heavy type)
889.92 Providing and fixing chromium plated brass handles with necessaryscrews etc. complete:9.92.3 75 mm
899.63 Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : (copper oxidizedas per IS: 1378)9.63.1 250x10 mm
909.48 Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc
9113.48 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :13.48.3 Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
924.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth.
936.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
945.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
955.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.3 Suspended floors, roofs, landings, balconies and accessplatform
965.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
97Construction of Mid day Meal Room2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil
9816.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
994.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived fromnatural sources : 6 graded stone aggregate 20 mmnominal size derived from natural sources)
1005.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
1015.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.1 Foundations, footings, bases of columns, etc. for massconcrete
1025.1 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1035.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers
1045.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
1055.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
1065.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
1075.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
1086.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
1096.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
1105.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
1115.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
11213.5 15 mm cement plaster :13.5.2 1:6 (1 cement : 6 coarse sand)
11311.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
11413.43 Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
11513.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
1164.10 Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources)
11712.65 Providing & fixing at all heights, levels and locations colourfinish Aluminium alloy roofing sheets of alloy IS designation31500, temper Hx8 conforming to IS 737 and dimensions asper IS code 2676 with characteristics of good formability andcorrosion resistance. The profile sheets shall be fixed to trussmembers in slope or required pitch or curvature with Hexcap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive oflabour, scaffolding, T&P and sundries etc. complete as perdirections of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately).12.65.5 0.71mm Aluminium color coated profile with centerto center pitch of 175 mm, depth of 46mm, topcrest width of 41mm, bottom valley width of80mm, overall profile width of 1144mm, cover width1050mm.
11810.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes
1199.1 Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately).9.1.2 Sal wood
1209.5 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters
12113.48 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :13.48.2 Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture
1224.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth.
1239.48 Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc
12413.48 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :13.48.3 Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
1256.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
1265.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
1275.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.3 Suspended floors, roofs, landings, balconies and accessplatform
1285.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
12911.41A Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge,clips of required thickness, leveling system and rubber mallet forplacing the tiles gently and easily.11.41A.2 Glazed vitrified floor tiles polished finish of size11.41A.2.1 Size of Tile 600 x 600 mm
130Construction of store2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil
13116.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
1324.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived fromnatural sources : 6 graded stone aggregate 20 mmnominal size derived from natural sources)
1335.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
1345.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.1 Foundations, footings, bases of columns, etc. for massconcrete
1355.1 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1365.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers
1375.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
1385.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
1395.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
1405.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
1416.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
1426.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
1435.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
1445.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
14513.5 15 mm cement plaster :13.5.2 1:6 (1 cement : 6 coarse sand)
14611.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
14713.43 Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
14813.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
1494.10 Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources)
15012.65 Providing & fixing at all heights, levels and locations colourfinish Aluminium alloy roofing sheets of alloy IS designation31500, temper Hx8 conforming to IS 737 and dimensions asper IS code 2676 with characteristics of good formability andcorrosion resistance. The profile sheets shall be fixed to trussmembers in slope or required pitch or curvature with Hexcap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive oflabour, scaffolding, T&P and sundries etc. complete as perdirections of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately).12.65.1 0.56 mm, Aluminium Color coated troughed profilewith center to center pitch of 200 mm, depth of32 mm, overall profile width1092 mm, cover width1000mm.
15110.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes
1529.1 Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately).9.1.3 Kiln seasoned and chemically treated hollock wood
1539.5 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters
15413.48 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :13.48.2 Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture
1559.72 Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete :9.72.1 125x85x5.5 mm (heavy type)
1569.92 Providing and fixing chromium plated brass handles with necessaryscrews etc. complete:9.92.3 75 mm
1579.63 Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : (copper oxidizedas per IS: 1378)9.63.1 250x10 mm
1589.62 Providing and fixing ISI marked oxidised M.S. sliding door bolts withnuts and screws etc. complete : (copper oxidized as per IS: 1378)9.62.2 250x16 mm
1592.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
16016.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
1614.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth.
162Construction of Drain2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil
16316.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
1644.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources)
1656.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
16611.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
16723.9 Providing and fixing factory made precast RCC perforated drain covers,having concrete of strength not less than M-25, of size 1000 x 450x50mm, reinforced with 8 mm dia four nos longitudinal & 9 nos crosssectional T.M.T. hoop bars, including providing 50 mm dia perforations@ 100 to 125 mm c/c, including providing edge binding with M.S.flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
1685.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.1 Foundations, footings, bases of columns, etc. for massconcrete
169Construction of Paver Block approach road16.78 Construction of granular sub-base by providing close graded Materialconforming to specifications, mixing in a mechanical mix plant atOMC, carriage of mixed material by tippers to work site, for all leads& lifts, spreading in uniform layers of specified thickness with motorgrader on prepared surface and compacting with vibratory power rollerto achieve the desired density, complete as per specifications anddirections of Engineer-in-Charge.16.78.2 With material conforming to Grade-II (size range 53 mmto 0.075 mm ) having CBR Value-25
17016.91 Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge.16.91.2 80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern.
1714.3 Centering and shuttering including strutting, propping etc. and removalof form work for :4.3.2 Retaining walls, return walls, walls (any thickness) includingattached pilasters, buttresses, plinth and string courses fillets,kerbs and steps etc.
1724.4 Providing and laying cement concrete in kerbs, steps and the like at ornear ground level excluding the cost of centering, shuttering andfinishing.4.4.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources)
173Sanitary and Plumbing work17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require:17.7.1 White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps
17417.28 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.17.28.2 Flexible pipe17.28.2.1 32 mm dia
17517.35 Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729
17617.69 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mmbreadth weighing not less than 45 gms
17718.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.External work18.9.1 15 mm nominal dia Pipes metre
17818.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.External work18.9.2 20 mm nominal dia Pipes
17918.15 Providing and fixing brass bib cock of approved quality :18.15.1 15 mm nominal bore
180Installation of Deep Tube Well23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer-in-charge, upto 90 metre depth below ground level.23.1.2 Rocky strata including Boulders23.1.2.1 300 mm dia
18123.3 Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labourcharges, fittings & accessories etc. all complete, for all depths, asper direction of Engineer -in-charge.23.3.2 150 mm nominal size dia
18223.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge.
18323.12 Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well is fullydeveloped, measuring yield of well by \\"V\\" notch method or any otherapproved method, measuring static level & draw down etc. by stepdraw down method, collecting water samples & getting tested inapproved laboratory, i/c disinfection of tubewell, all complete, includinghire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge.
18423.15 Providing and fixing Bail plug/ Bottom plug of required dia to thebottom of pipe assembly of tubewell as per IS:2800 (part I).23.15.2 150 mm dia
18518.43 Providing and placing in position filters of 40 mm diameter G.I. pipewith brass strainer of approved quality
18618.46 Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (Newwork) :18.46.5 40 mm nominal bore
18718.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.18.9.5 40 mm nominal dia Pipes
18818.19 Providing and fixing gun metal non- return valve of approved quality(screwed end) :18.19.3 40 mm nominal bore18.19.3.2 Vertical
189Supplying, fiting, fixing of 1 Hp motor pump set as Kirloskar/Usha or equivelent(Rate Analysis)
190Repairing of Toilet Block15.28 Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet
19110.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes
19212.65 Providing & fixing at all heights, levels and locations colourfinish Aluminium alloy roofing sheets of alloy IS designation31500, temper Hx8 conforming to IS 737 and dimensions asper IS code 2676 with characteristics of good formability andcorrosion resistance. The profile sheets shall be fixed to trussmembers in slope or required pitch or curvature with Hexcap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive oflabour, scaffolding, T&P and sundries etc. complete as perdirections of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately).12.65.1 0.56 mm, Aluminium Color coated troughed profilewith center to center pitch of 200 mm, depth of32 mm, overall profile width1092 mm, cover width1000mm.
19313.91 Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete.
19413.43 Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
19513.82 Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required,to achieve even shade and colour.13.82.2 Two coats
19615.2 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix)
1972.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
19816.12 Dry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
19911.5 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete.
20011.41A Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge,clips of required thickness, leveling system and rubber mallet forplacing the tiles gently and easily.11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm
2018.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete.
20215.2 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge.15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix)
2035.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
2045.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers
2055.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
2065.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
2075.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
2086.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
2099.117 Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the doorframe to be Jointed with galvanized brackets and stainless steel screws,joints mitred and Plastic welded. The hinge side vertical of the framesreinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the framecomplete as per manufacturer’s specification and direction of Engineerin-charge9.117.2 Extruded section profile size 42x50 mm
2109.118 Providing and fixing to existing door frames.9.118.1 24 mm thick factory made PVC door shutters made of stylesand rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides.The styles and rails mitred and joint at the corners by meansof M.S. galvanised/ plastic brackets of size 75x220 mm havingwall thickness 1.0 mm and stainless steel screws. The stylesof the shutter reinforced by inserting galvanised M.S. tube ofsize 20x20 mm and 1 mm (± 0.1 mm) wall thickness. Thelock rail made up of 'H' section, a uPVC hollow section of size100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to theshutter styles by means of plastic/galvanised M.S. 'U' cleats.The shutter frame filled with a uPVC multi-chambered singlepanel of size not less than 620 mm, having over all thicknessof 20 mm and 1 mm (± 0.1 mm) wall thickness. The panelsfilled vertically and tie bar at two places by inserting horizontally6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturer's specification anddirection of Engineer-in-charge. (For W.C. and bathroom doorshutter).
2119.53 Providing 40x5 mm flat iron hold fast 400 mm long including fixing toframe with 10 mm diameter bolts, nuts and wooden plugs and embeddingin cement concrete block 300x100x150 mm 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size).
2129.72 Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete :9.72.1 125x85x5.5 mm (heavy type)
2139.92 Providing and fixing chromium plated brass handles with necessaryscrews etc. complete:9.92.3 75 mm
214Construction of RCC Stagging2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil
2154.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources)
2164.3 Centering and shuttering including strutting, propping etc. and removalof form work for :4.3.1 Foundations, footings, bases for columns
2174.3 Centering and shuttering including strutting, propping etc. and removalof form work for :4.3.2 Retaining walls, return walls, walls (any thickness) includingattached pilasters, buttresses, plinth and string courses fillets,kerbs and steps etc.
2185.1 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
2195.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
22012.1 Providing corrugated G.S. sheet roofing including vertical / curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
2215.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
2225.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.1 Foundations, footings, bases of columns, etc. for massconcrete
2235.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.3 Suspended floors, roofs, landings, balconies and accessplatform
2245.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers
2255.9 Centering and shuttering including strutting, propping etc. and removalof form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
2265.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
2275.22A Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
22813.5 15 mm cement plaster :13.5.1 1:4 (1 cement : 4 coarse sand)
22913.37 White washing with lime to give an even shade :13.37.1 New work (three or more coats)
23013.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)
23118.48 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
232Boundary wall ColourRemoving dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete.
23313.43 Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
23413.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
235Electrification Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58387226
AUTHORITY Government Departments
TENDER VALUE 75 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Bodoland Territorial Council
Work Description Tender for Construction Of Major Renovation Works At Keshab Deka Memorial Lps (18010211702), District Kokrajhar Under Dharti Aaba Janjatiya Gram Utkarsh Abhiyan (Dajgua) Tribal Affairs (Plain) For The Financial Year 2026-27
Basic Detail
Tender No ACE-83/NIT/DAJGUA/BTC/2026-27
Bidding Type Tender
Location
City Kokrajhar
State Assam
Key Dates
Publish Date 05 Nov 2026
Submission Date 30 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value 75 Lakhs
Tender Fee 1500
EMD 1.50 Lakhs
Exemption Available
Document List
63bf153d-799d-4fe7-b118-7bdf49a82942.html
BOQ_85829.xls
FOB_TN_52_16.pdf
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

63bf153d-799d-4fe7-b118-7bdf49a82942.html

xls

BOQ_85829.xls

pdf

FOB_TN_52_16.pdf

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender