Housing Urban and Rular Development Government Departments Closing in 5 days TDR #58386325

Tender For Running, Maintenance & Operation Of Specialized Electrical & Mechanical Services Installed At Various Residential Flats Near Lok Niwas Marg And Honble Lg Secretariate Under M4512, Delhi. (Sh:- Providing And Installation Of Various Electric

Issued by Government Departments · Delhi, Delhi
Tender Value
41.28 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
5 days left
EMD
82562
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Running, Maintenance & Operation Of Specialized Electrical & Mechanical Services Installed At Various Residential Flats Near Lok Niwas Marg And Honble Lg Secretariate Under M4512, Delhi. (Sh:- Providing And Installation Of Various Electrical Equipments& Other Miscellaneous Electrical Works).

BOQ

Name of Work:- Running, Maintenance & operation of Specialized Electrical & Mechanical Services installed at various residential flats near Lok Niwas Marg and Honble LG Secretariate under M4512, Delhi. (SH:- Providing and installation of various Electrical Equipments& other miscellaneous Electrical Works).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1. 5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1. 5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (a) Group B
2(b) Group C
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
5(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6Supplying and fixing of following sizes of medium class PVC conduit/ channel along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25 mm
7Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(a) 1 run of cable
8Supplying and fixing suitable size GI / PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
9Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
10Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.7.1) 1 or 2 Module (75 mmX75 mm)
117.2) 6 Module (200mmX75mm)
127.3) 12 Module (200 mmX150 mm)
13Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.8.1) 15/16 A switch
148.2) 6 pin 15/16 A socket outlet
158.3) Telephone socket outlet
16Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(a) 8 way (4 + 24), Double door
17(b) 4 way (4 + 12), Double door
18Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
19Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board / MCB DB including drilling holes, making connections, etc. as required.11.1) 100 A, 16 KA, TPMCCB
2011.2) 250 A, 36KA, FPMCCB
2111.3) 400 A, 50KA, FPMCCB
22Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
23Supplying and fixing 4 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
24Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
25LED Panel light 2x2 ft. (System lumen efficacy =105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2. 5 KV with Short & Open circuit protection, THD < 10%, P. F. =0. 95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0. 50 mm) (a) 36 Watt
26LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 degree C to 40 degree C internal surge protection of 2. 5 KV with Short & Open circuit protection, THD < 10%, P. F. =0. 95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim. 12 -15 watt
27Brush Less Direct Current (BLDC) MotorSupplying, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required.(a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
28Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required.
29Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
30Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade on surface /direct into ground/cable tray/pipe etc. as required.(a) 4 x 25 sq.mm
31(b) 3x10 sq.mm
32Supplying, installation, testing and commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as required.SH-II (Air-Conditioners & Other EI Accessories)Supply, Installation, Testing and Commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V withlow & high voltage cut off and50 hz ,1 phase AC supply capable of performing cooling, heating, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature).
3321.1) 2. 0 TR with minimum 3 Star BEE Rating
34Providing & Laying of refrigerant copper piping of size 1/4\\" or 3/8\\" & 5/8\\" diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable along with necessary support complete etc all as per Direction of Engineer-in-charge.
35Supplying & Drawing of 3x4 sqmm size of PVC insulated &pvc sheathed copper conductor round multicore flexible cable for indoor to outdoor and upto nearest power point i/c providing suitable copper lugs connection etc as required.
36Providing & fixing of 25 mm dia (Schedule-40) UPVC/heavy duty PVC white colour drain pipe of with necessary fitting such as nipple, reducer, clamp on surface / recess i/c cutting the wall and making good the same complete as required.
37Supplying, installation, testing & commissioning of vertical type following capacity Storage/Instant Electrical Geysers, energy efficient, minimum 5 Star Rating and having proper shell fixed with safety plug, thermostat & heating element On/Off indication & digital indication of temperature etc. complete with water pipe connection complete as required.(a) 50 Liters Capacity Storage Type
38(b) 25 Liters Capacity Storage Type
39(c) 15 Liters Capacity Storage Type
40(d) 5-6 Liters Capacity Instant Type
41(e ) 100 Litres Capacity Storage Type
42Supplying & replacement of following burnt out accessories in the existing 15 ltr. Capacity storage type water gysers etc. as reqd. i/c credit for worn out accessories under buy back.26.1) 1.5/2KW Geyser heating element
4326.2) Geyser thermostat
44Supplying & replacement of following Electrical accessories in the existing electrical installation i/c credit for the old material i/c connections etc. complete as reqd.27.1) electric remote bell with power source AA battery,sound range-30 mtr
4527.2) 9-10 watt, with E 27/B22 Base Worm White/CDL LED Bulb.
4627.3) 5 watt, with E 14 Base Worm White/CDL LED Candle Bulb.
4727.4) 32 Amp. Modular SP MCB
4827.5) 32 Amp. Modular DP MCB
4927.6) Supply & Fixing of 3 Core 1.5 Sq. mm PVC round sheathed Multicore bright Electrolytic annealed bare copper conductor Flexible Industrial Power Cables for working voltages upto and including 1100 Volts
5027.7) Supply & Fixing of 3 Core 2.5 Sq. mm PVC round sheathed Multicore bright Electrolytic annealed bare copper conductor Flexible Industrial Power Cables for working voltages upto and including 1100 Volts
51Supplying, installation, testing & commissioning of Air Purifier for an area coverage upto 670 sq. Ft., having a Pre-filter, Activated Carbon Filter, True HEPA H13 Filter, and Plasma filtration to remove up to 99.97% of dust and particulate matter as small as 0.1 μm. Air purifier should be capable to control with smart phone applications and suitable to operate on single phase 240 Volts 50 HZ AC supply etc. complete as required.
52Supplying, installation, testing & commissioning of Air Purifier having Air Multiplier Technology, covers upto a area of 80 sqm, combine intelligent sensing with an advanced HEPA H13 filtration system captures gases2, pollutants and viruses, captures viruses and 99.95% of pollutants as small as 0.1 microns³, control using the link app and compatible voice services suitable to operate on single phase 240 Volts 50 HZ AC supply etc. complete as required.
53Supplying and fixing of 9 Fins Oil Filled Room Heater (ISI marked) with 3 positions wattage Min-800W to Max-2000W, adjustable thermostat, PTC heating element, over heat protection, castor wheels suitable for operation on 230V, 50Hz, single phase AC supply complete with testing etc. as required.
54Supplying, installation, testing & commissioning of 800 watt Rod type quartz heater suitable for operation on 230V, 50Hz, single phase AC supply complete with testing etc. as required.
55Supplying, installation, testing & commissioning of 2000 watt heat convector with two fan speed setting suitable for operation on 230V, 50Hz, single phase AC supply complete with testing etc. as required.
56Supplying, installation, testing & commissioning of 60 watt insect killer having 2 x 20 watt lamps made out of stainless steel, suitable for pest control for flies, insects, mosquitoes in covering area of 700-800 sq.ft. with protection grill etc. complete as required.
57Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F. =0. 95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. . Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 50 Watt
5834.1) 150 watt
59Supplying, installation, testing & commissioning of LED Post top Fitting of system 40 - 45 watt of multiple LED with lens optics and IP65 pressure die-cast aluminium housing for effective thermal management total system lumen of 40W LED should be 200 or above in cool day light (5700K to 6500K), power factor>0.90, CRI>70 complete with mounting brackets on gate i/c connection 1.5 sq.mm copper conductor cable etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58386325
AUTHORITY Government Departments
TENDER VALUE 41.28 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Running, Maintenance & Operation Of Specialized Electrical & Mechanical Services Installed At Various Residential Flats Near Lok Niwas Marg And Honble Lg Secretariate Under M4512, Delhi. (Sh:- Providing And Installation Of Various Electrical Equipments& Other Miscellaneous Electrical Works).
Basic Detail
Tender No 170/EEE/PWDDHC,NDC/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 05 Nov 2026
Submission Date 10 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 41.28 Lakhs
Tender Fee Ref. Documents
EMD 82562
Exemption Not Available
Document List
62e418b0-66c9-4ec2-b6aa-a13e3f2cac8b.html
BOQ_401732.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

62e418b0-66c9-4ec2-b6aa-a13e3f2cac8b.html

xls

BOQ_401732.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender