Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58385904

Tender For Special Repair Of Generator Set Room (Bldg No P-25) And Provn Of 14 Exhaust Fans Alongwith Allied Electric Fttings Under Ge (South) Ambala Cantt.

Issued by Statutory Bodies & Commissions/Committees · Ambala, Haryana
Tender Value
3.84 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
5 days left
EMD
7700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Generator Set Room (Bldg No P-25) And Provn Of 14 Exhaust Fans Alongwith Allied Electric Fttings Under Ge (South) Ambala Cantt.

BOQ

Name of Work:- SPECIAL REPAIR OF GENERATOR SET ROOM (BLDG NO P-25) AND PROVN OF 14 EXHAUST FANS ALONGWITH ALLIED ELECTRIC FTTINGS UNDER GE (SOUTH) AMBALA CANTT.
Sl. No. Item Description
1[B&R PORTION]Demolition of brick work built in cement mortar including all quoins pillars etc complete all as specified and directed by Engineer-in-Charge.
2Material and labour for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), with necessary scaffolding etc complete all as specified and directed by Engineer-in-Charge.
3Taking down cement plaster from brick or concrete surfaces including raking out joints,hacking keys, scrubbing down with water etc. complete all as specified and directed by Engineer-in-Charge.
4Material and labour for rough cast plastering including 15 mm thick rendering in CM 1:3 complete as specified in SSR Part I, clause 14.22.(Note : Rough cast finish to be as below :-After applying the under coat of cement mortar 1:3 and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered.( Upto height 15 mtrs)
5Material and labour for rendering 10mm thick on fair face of brick work , concrete surfaces in cement mortar 1:6 finished even and smooth without extra cement complete all as specified and directed by Engineer-in-Charge.
6Material and labour for rendering 15 mm thick on fair face of brick work , concrete surfaces in cement mortar 1:4 finished even and fair without extra cement mixed with WPC @ 2% by wt of cement or as per manufacturer instruction complete all as specified and directed by Engineer-in-Charge.
7Supply only, integral water proofing compund complete all as specified and directed by Engineer-in-Charge.
8Material and labour for rendering 10mm thick in CM (1:3) on ceiling surfces finished even and smooth without using extra cement.complete all as specified and directed by Engineer-in-Charge.
9Material & Labour for two coats of oil bound distemper over a coat of primer including preparation of new plastered surfaces of walls and applying 1.5mm thick (Minimum) white cement based wall care putty in two coats, finished even and smoot complete all as specified and directed by Engineer-in-Charge.
10Material and labour for two coats of cement base paint over a coat of alkali resistant primer including preperation of new surfaces of walls complete all as specified and directed by Engineer-in-Charge.
11Material and labour for two coat of white wash including preparation of new surfaces of ceiling complete all as specified and directed by Engineer-in-Charge.
12Dismantling floor, hearth or wall tiling/stone including cement mortar bedding (but not backing) removing debries out side defence area complete all as specified and directed by Engineer-in-Charge.
13Material and labour for machine cut kota stone slab 20-25 mm thick ( size of each stone not less than 55cm x 55cm), laid in flooring, over and including cement screed bed 20mm thick in cement mortar (1:4) base set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Mirror finish) complete all as specified and directed by Engineer-in-Charge.
14Material and labour for machine cut kota stone slab 18-20 mm thick ( size of each stone in single piece, laid on vertical surfaces of skirting/dado, over and including cement screed bed 15 mm thick in cement mortar (1:3) and set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Mirror finish) complete all as specified and directed by Engineer-in-Charge.
15Material and labour for coloured glazed ceramic tiles (300x 450x 7mm thick) in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
16Taking down wooden chowkats or frames with shutter (without taking off shutter from the frames), area not exceeding 1.5 Sqm each and removal from site including iron mongry hold fasts etc., complete all as specified and directed by Engineer-in-Charge.
17Supply and fixing Steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. . (i) For the purpose of measurement & payment double shutter with frame shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery, Guard bars etc (iii) Glazing, wire mesh & painting shall be measured & paid for separately.
18Supply and fixing galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanised wire staple with beads to wooden joinery when fixed in panels of joinery and with screws when fixed to steel windows, complete all as specified and as directed by Engineer-in-Charge.
19Supply and fixing of sheet glass 3mm thick, ordinary quality, in square not exceeding 0.5 Square metre each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters complete all as specified and as directed by Engineer-in-Charge.
20Material and labour for two coat of synthetic enemal paint on new steel surfaces of any description incl priming coat of red oxide perimer , over 10cm in width or girth,not otherwise described incl preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
21Demolition of cement concrete in floors and pavings not exc 15 cm thickness below or above ground level, complete all as specified and as directed by Engineer-in-Charge.
22Material and labour for 100 mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-Charge.
23Material and labour for factory made PVC moulded, of approved colour with grey cement and pigment, glossy finished, vibrated machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, over and including 30mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed by Engineer-in-Charge.
24Material and labour for PCC in roof kerbs of mud stops, rounded or chamfered on edges type B1 (1:2:4) (using 20 mm graded stone aggregate) complete all as specified and as directed by Engineer-in-Charge.
25Material and labour for cleaning the roots top surfaces, brick tiles or concrete surfaces by picking, vegitation roots, sweeping clean and washing down with water to remove dust etc and filling & damaged joints of brick tiles in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
26Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete all as specified and as directed by Engineer-in-Charge.
27Material and labour for 40mm thick average thickness PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in roof padding, levelling course and finishing top surfaces even and smooth using extra cement to receive APP membrane ,complete all as specified and as directed by Engineer-in-Charge.
28Material and labour APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.6 Kg/Sqm black finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm torching over laps with a propane or butan gas torch with a over lap of 75 mm at the side and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminious primer all as per manufacturers instructions incl preparation of surface complete all as specified and directed by Engineer-in-Charge. Note :-i) The water proofing treatment shall be got carried out by the manufactarer or their authorised applictor's duly approved by GE in writing. ii)The laying of membrane shall be carried out through the manufacturer or their authorized applicator only with Gurantee of 10 years by contractor.
29Demolition of reinforced cement concrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
30Material and labour for MS bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
31Material and labour for Nominal mix 1:2:4 type B-1 (20mm graded stone aggregates) as in slabs support on wall ,beam ,columns, lintel band ,landing, shelves etc and the like complete all as specified and directed by Engineer-in-Charge..
32Formwork to chullah hoods, chajjas, selfs,troughs and similar items including edges, complete all as specified and directed by Engineer-in-Charge.
33[E&M PORTION]Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc, complete all as specified and as directed by Engineer-in-Charge.
34Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point/exhaust point controlled by one switch complete all as specified and as directed by Engineer-in-Charge.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only.
35Description all as per item No 34.00 here in before but for socket out let point 5 Amps on same board, complete all as specified and as directed by Engineer-in-Charge.
36Description all as per item No 34.00 here in before but for socket out let point 5 Amps on independent board, complete all as specified and as directed by Engineer-in-Charge.
37All as per srl item No 34.00 here in before but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor, complete all as specified and as directed by Engineer-in-Charge.
38Supply and fixing in repair modular switch 5 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and directed.
39Supply and fixing in repair modular switch 15 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and directed.
40Supply and fixing in repair modular socket outlet 3 pin 5 amps, 230 volts flush type , complete all as specified and directed.
41Supply and fixing in repair modular socket outlet 16 amps, 230 volts flush type , complete all as specified and directed.
42Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
43Supply and fixing of LED light fitting 1x20W , 220V,not less than 100 lumen per watt, AC batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed. Note: LED cool white/warm white must get approved from engineer-in-charge.
44Supply and fix bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description complete all as specified and as directed by Engineer-in-Charge.
45Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE:- 3 run of 4.0 sqmm cable with concealed conductor shall be measured as 1 unit.
46Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and as directed by Engineer-in-Charge.
47Supply and fixing MCB SP single pole, 240 volts, 50 Hz, breaking capacity , 6 to 32 Amps, complete all as specified and as directed by Engineer-in-Charge.
48Supply and fixing SPN 40 -63 Amps rating ,240 volts, 50 Hz, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
49Supply and fixing Exaust fan (MS Body) AC single phase 230 Volts of size 300mm sweep, 1400RPM,double ball bearing,heavy duty with blades,frames including fixing arrangment metal body with louvers complete all as specified and as directed by Engineer-in-Charge.
50Material and labour for making Drilling hole(Square or Round shape) or making provision in existing brick/ Pcc wall surface of size suitable for mounting of exhaust fan of capacity 300 mm sweep of any type /body including fixing nuts, bolts, fasteners, and necessary cement work making good the disturded surfaces , giving electric connections and testing complete all as specified and as directed by Engineer-in-Charge.
51NOTE:- Amount of credit of Rs. 3,364.00 for retrieved materials is mentioned in Schedule of Credit Page No 21 of tender documents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58385904
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 3.84 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Generator Set Room (Bldg No P-25) And Provn Of 14 Exhaust Fans Alongwith Allied Electric Fttings Under Ge (South) Ambala Cantt.
Basic Detail
Tender No GE(SOUTH)/AMB-59/2026-2027
Bidding Type Tender
Location
City Ambala
State Haryana
Key Dates
Publish Date 05 Nov 2026
Submission Date 26 Nov 2026
Open Date 28 Nov 2026
Finance
Tender Value 3.84 Lakhs
Tender Fee 500
EMD 7700
Exemption Available
Document List
17dced9d-9bf1-46e5-83fe-bccbf9396d44.html
BOQ_894438.xls
Tenderdocuments_59.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

17dced9d-9bf1-46e5-83fe-bccbf9396d44.html

xls

BOQ_894438.xls

pdf

Tenderdocuments_59.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender