Tender For Repair And Renovation Of Sahid Park,11Th Mile, Kalimpong, G.T.A.
Tender Value
2.41 Crore
Estimated cost
Bid Submission
27 Nov 2026
14 days left
EMD
4.82 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kalimpong → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Renovation Of Sahid Park,11Th Mile, Kalimpong, G.T.A.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 2 | Taking out doors, windows and clerestory window shutters (steel or wood)including stacking within 50 metres lead : |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead |
| 4 | Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 7 | Dry stone pitching 22.5 cm thick including supply of stones and preparingsurface complete. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 13 | 5.9.3: Suspended floors, roofs, landings, balconies and access platform |
| 14 | 5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | 5.9.6: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | 5.9.16.1: Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 19 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 20 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : |
| 21 | 15 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) INTERIOR |
| 22 | 20 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) EXTERIOR |
| 23 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) CEILING |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: |
| 25 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 26 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : |
| 27 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm |
| 28 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (copper oxidized as per IS: 1378). 125 mm |
| 29 | Providing and fixing aluminium sliding door bolts, ISI marked anodise(anodic coating not less than grade AC 10 as per IS : 1868), transparentor dyed to required colour or shade, with nuts and screws etc. complete : |
| 30 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 31 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete |
| 32 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 34 | Providing and fixing precoated galvanised iron profile sheets (size, shape and itch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 35 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 36 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : |
| 37 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 38 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 39 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 40 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over plastered surface to prepare the surface even and smooth complete. |
| 41 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 42 | Finishing walls with water proofing cement paint of required shade : |
| 43 | Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 44 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : |
| 45 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) INTERIOR |
| 46 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over plastered surface to prepare the surface even and smooth complete. |
| 47 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 48 | Finishing walls with water proofing cement paint of required shade : |
| 49 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) CEILING |
| 50 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 51 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 52 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete |
| 53 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : |
| 54 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 55 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 56 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 57 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cutwith the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 58 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface |
| 59 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixturescomplete, including cutting and making good the walls and floors wherever required : |
| 60 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 61 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 62 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge |
| 63 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 64 | Providing and fixing toilet paper holder : C.P. brass |
| 65 | Providing and fixing soil, waste and vent pipes : 100 mm dia. : Centrifugally cast (spun) iron socket & spigot(S&S) pipe as per IS: 3989 |
| 66 | Providing and fixing plain bend of required degree. : 100 mm dia : Sand cast iron S&S as per IS : 3989 |
| 67 | Providing and fixing double equal plain junction of required degree. : 100x100x100x100 mm : Sand cast iron S&S as per IS - 3989 |
| 68 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 69 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVCplain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 25 mm nominal dia Pipes |
| 71 | Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. |
| 72 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 73 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 74 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints completeas per direction of Engineer in Charge.50 mm nominal dia Pipes |
| 76 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 .15 mm nominal bore |
| 77 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm |
| 78 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 79 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. 50 mm dia nominal bore |
| 80 | Earth work in excavation by mechanical/manual means in foundation trenches/drains, all kinds of soil |
| 81 | Filling available excavated earth in trenches/plinth/sides of foundations, compacted and watered |
| 82 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. |
| 83 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 84 | RCC work in walls, 1:1.5:3, 20 mm aggregate — outer walls and partition |
| 85 | Centering and shuttering for suspended/access slab |
| 86 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 87 | 20 mm cement plaster 1:4 — internal walls, partition and floor |
| 88 | Providing, laying and jointing glazed stoneware pipe, 150 mm dia |
| 89 | Providing, laying and jointing glazed stoneware pipe, 100 mm dia — ventilation |
| 90 | Providing and fixing watertight manhole cover and frame, approx. 500 mm dia (provisional market rate) |
| 91 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design |
| 92 | Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, asper direction of Engineer-in-charge. |
| 93 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 94 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 95 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 96 | Dry stone pitching 22.5 cm thick including supply of stones and preparingsurface complete. |
| 97 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 98 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 99 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 100 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 101 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 102 | 5.9.16.1: Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 103 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 104 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 105 | Back filling behind abutment, wing wall and return all complete including spriklring water and throughly compacted with plate compactor/power rammer in layers not exceeding 150mm compacted thickness as per drawing and Technical Specification (710.1.4 of IRC:78 & MoRTH's specification 2200 |
| 106 | Providing weep holes in Brick masonry/Plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC/PVC/HDPC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications (Reference to MORT&H's specifications 2706 & 2200). |
| 107 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) EXTERIOR |
| 108 | Neat cement punning. |
| 109 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 110 | Designing. providing and fixing multiwall three or more layered polyca.bonate sheet panel co\\"gxtruded Ultra Violet ([,rV) protective coating on extcmal surface with standing seam on both the running ends. sheet shall be connected using polycarbonatc conneclors having grip lock double tooth locking mcchanism and provided with endcap al the ends toensurc [alcr and air tightncss. lhc lighl lransmission liom transparcnt or transluccnl or opaque or in combinalionpolycarbonate sheel. varics from l5 to 85o/b. shall bc dccided by cnginccr in charge as per requircmenl. fhc polycarbonate shocl shall ha\c I)afl dnrp impacl raluc tnorc than 60 Joulcs as per IS 1.1,13.1 2021 and conlirm cithcr llamc relardanct ol' class Ll l,-941 Illi94v-0 catsEroD as pcr ISI{{11:2021 or cdcgr)r) V0 & Illl as per nsl\4 l)615-18 or t}Sll)0 classillcalion as pcr ENl350l lbr llrc sal!ry. Ihc ycllonncss indcr testcd ns plr AS IM Ell3 (D1925) or AS IM E3ll (D1925) shall be equal to or more than l0 unit or 6 units respeclively on a sanple afler 5000 llours of exposure of UV / sun light. The cross section ends ofpoly calbonate sheet shall be provided with self-adhesive aluminium impermeable tape al top and aluminium ventilated tape at bottom of the sheet and covered with polycarbonate / aluminium u-shaped proteclive prollle. Thc poly carbonate sheel shall be held in position by using stainlcss steel (SS304 gTade) trapezoidal clcal ol I mm thick having minimum botlom width 35mm and top width 50mm or any other shape and size as per design requiremenl and manufacturer specification, cleal ,lxed wilh 2 or more stainless steel screws of 5 mm diameter with 25mm long with structural steel frarnework. 'lhe cleat shall bc tcstcd to withstand pull oul force equal to wind speed of 50rn/s as perlS:875 and design tesl repon shall be submined to Engineer-in-charge for approval before use. 'fhc cosl ofridge ard gutters of pre.coated galvanized iron sheet of app.oved specificalions and struclural steel framework of shall be paid in resp€ctive item for separately.Notei- l'he fixing arrangement using cleat shall be designed separately for coastal aleas for cyclonic wind speed. |
| 111 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 112 | Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-Charge) of totalcoated thickness 0.50 mm (base metal of minimum 0.45 mm thicknesswith total coating thickness of 0.05mm) with zinc coating 120 grams persqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns. Sheet shouldhave protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling /self tapping screws of size (5.5x 55 mm) with EPDMseal, complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required. |
| 113 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 114 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 115 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 116 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 117 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 118 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content |
| 119 | Finishing walls with water proofing cement paint of required shade : |
| 120 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laidin required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 121 | Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, includingproviding and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge. |
| 122 | 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1 mm to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume, including cement slurry etc. complete |
| 123 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 124 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge |
| 125 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 126 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 127 | Construction of 6 ft High Marble Fountain as per IndiaMart including cost of Material, carriage , loading , unloading, GST and Contractors Profit |
| 128 | Dismantling of Cement Concrete PavementDismantling of cement concrete Complete Rate pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately (Reference to MoRT&H's specification clause 202) |
| 129 | Earth work in excavation of foundation of structures as per drawing and technical specification,including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (Reference to MORT&H's specification 304). |
| 130 | Plain/Reinforced cement concrete in sub-structure complete all including vibrating and compacting, finishing, curing, sampling, testing etc. by mechanically mixed as per drawing and Technical Specifications(Reference to MORT&H's specifications 1500, 1700 & 2200). |
| 131 | Water Bound MacadamProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density (Reference to MoRT&H's specification 404). |
| 132 | By Mix in Place MethodConstruction of granular sub-base by providing graded materials such as natural sand/crushed gravel/crushed stone/combination depending upon the required grading , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibratory roller to achieve at least 98% of the maximum dry density for the material determined as per IS:2720 (Part 8),complete as per clause 401 desired density, complete as per clause 401 |
| 133 | Concrete Block Pavement Supplying and Laying in the particular pattern of cement concrete block pavements with BIS certification and spacer nib of size and shape with aspect ratio as per IS 15658 with cement concrete grade not less than M40 on the prepared base course of specified CBR as mentioned in design and drawing with a cushion of bedding sand of 30 to 50 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP-63) and filling up the gaps between two paver block with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2) complete as per IRC SP - 63 with proper confinement of bedding and joint filling sand, compaction,levelling and filling up of the edge gaps with mortar. Type I, II,III, IV should be as per design requeirment or instruction of E-I-C. |
| 134 | ELECTRICAL WORKS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group B |
| 135 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 136 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories insurface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 137 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 138 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. [Separate 16A Plug Point & AC] |
| 139 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 140 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) |
| 141 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm) |
| 142 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. asrequired. 5/6 A switch |
| 143 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door |
| 144 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panelboard with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. asrequired. 100 A TP&N |
| 145 | TPN D.B Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powderpainted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 146 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 147 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 148 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVCinsulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required |
| 149 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 150 | Providing and fixing M.S. Fan clamps of 16 mm dia M.S. bar, bent to shape with Hooked ends in R.C.C. slabs or beams during laying, including painting theexposed portion of loop, all as per standard design complete (DSR Civil-2014 item no. 10.17) |
| 151 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 152 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC)Motor. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 153 | Supply & delivery of heavy duty Exhaust Fan of Sweep:-12\\" (150mm), 240 volt, 50 Hz, AC , 50-60 Watts, Speed >900 RPM, Air delivery >=1145 CMM suitable for [Make - Orient (Model:Power Flow)/ EPC/ Havells/ Crompton Greaves] [Approved by EIC] |
| 154 | Laying on Wall / surface with Saddles / clamps Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 155 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired. 4 x 6 sq. mm |
| 156 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.(but without charcoal/ coke and salt) as required. |
| 157 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322. Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 24 -26watt |
| 158 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement. Powder coated die cast /Extruded aluminium Body including trim . 22 watt |
| 159 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement. 50 watt |
| 160 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 161 | Supplying and Installation of L.T. Main Panel with 16 SWG MS sheet enclosure on MS flat/ angle complete with TPN switch 6 Nos.(100 Amp), disconnector fuse unit-1 No.(200 Amp) , 4 pole changeover-1 No. (200 Amp) & 4 bars busbars- 2 Nos.(200 Amp), MCCB- 6 Nos.(125 Amp, ammeter and Voltmeter, Phase selector Switch and necessary connection(for 3 phase connection) |
| 162 | Supply And Installation Of 3Ph Energy Meter Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender