Tender For Establishment Of 132/33 Kv, 2X10 Mva Sub-Station At Wakro With Associated 132 Kv Lilo Line.

Issued by Government Departments · Lohit, Arunachal Pradesh
Tender Value
64.08 Crore
Estimated cost
Bid Submission
27 Nov 2026
11 days left
EMD
1.28 Crore
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lohit → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Establishment Of 132/33 Kv, 2X10 Mva Sub-Station At Wakro With Associated 132 Kv Lilo Line.

BOQ

Name of Work:- Establishment of 132/33 kV, 2x10 MVA Sub-Station at Wakro with associated 132 kV LILO Line.
Sl. No. Item Description
1SUPPLY SERVICES :-
2SH-I: 132 KV LILO DOUBLE CIRCUIT TRANSMISSION LINE:-
3Tower foundation Works:
4Concreting:
5Steel rods of all sizes for RCC works as per design.
6Galvanized Iron Structure:
7Galvanized Towers, steel members for structure, including Tower template.
8Galvanizing stubs, template Nuts & Bolts of various types of Towers.
9Earthing System:
10Tower earthing with GI Pipe & strips as per specification.
11Safety Alert System:
12Danger plates of size 250 mm x 200 mm of thickness 3 mm.
13Number plates of size 250 mm x 200 mm of thickness 3 mm.
14Phase plates (set of three pieces).
15Anti climbing devices with G.I. Thornwire/ Barbed wires.
16ACSR Conductor as per ISS:
17ACSR Panther (30/7/3.00 sqmm)
18Composite Polymer Insulator (Tension):
19132 kV, 120 kN
20Hardware fittings and accessories:
21Single tension 120 kN hardware fittings with all accessories as per IS for Panther.
22Double tension 120 kN hardware fittings with all accessories as per IS for Panther.
23Midspan compression joints for panther.
24Repair Sleeve for ACSR Panther conductor.
25Vibration Damper for ACSR Panther conductor.
26OPGW Cable and accessories:
2724 Fiber (DWSM) Optical Fiber Ground Wire (OPGW).
28Hardware set for 24 fibre OPGW cable i/c all fittings & accessories.
29Joint box (24 Fibre) for OPGW.
30SH-II: 132/33 KV, 2X10 MVA SUB-STATION :-
31Galvanised Structure:
32Design, fabrication and supply of hot-dipped GI lattice type tower made with angle iron for 132kV and 33 kV gantry towers and switchyard equipments support structures.
33Design, fabrication and supply of galvanizing stubs, template Nuts & Bolts, spring washers etc. as reqd.
34132 kV Switchyard Equipments:
353Ф, 10 MVA, 132/33 kV Transformer.
36EHT transformer oil as per ISI specification amended up to date.
37Nitogen Injection Fire Protection System (NIFPS)
38Online insulating oil drying system (Catridge type).
39145 kV, SF6, 3- Phase, Circuit Breaker, with support structure.
40145 kV, 600 A, 31.5 kA, 1- Phase, 3- Core current transformer with 120% extended current rating complete in all respects, along with associated accessories and a common MB. (Set of 3 Nos.)
41145 kV, 1250 A, 31.5 kA, 3- Phase Horizontal Centre Break Isolator with earth switch.
42145 kV, 1250 A, 31.5 kA, 3- phase Horizontal Centre Break Isolator without earth switch.
43145 kV, 1250 A, 31.5 kA, 3- phase Horizontal Centre Break Isolator without earth switch (Tandem)
44120 kV, 1-Phase, gapless Surge Arrester, rating (kV rms) - 120, complete in all respects with insulating base and surge monitor
45132 kV, 1-Phase, Capacitive Voltage Transformer with accessories complete in all respect. (Set of 3 Nos.)
46132 kV Control, Relay and Protection Panels:
47Control & Relay panel for line Bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories.
48Control & Relay panel for Transformer Bay with differential, overfluxing, LBB and backup protective relays and other auxiliary relays as required with SAS and all associated accessories.
49Control & Relay panel for bus coupler bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories.
50Sub-Station Automation:
51Substation Automation System (SAS) confirning IS 61850 with BCU and other complete associated equipment and accessories.
52Remote Terminal Unit and SCADA Gateway with all required ancilliary equipment/materials.
5333 kV Equipment:
5433 kV Gas Insulated Switchgear, 1250 A, 31.5 kA for 3 Sec, 50 Hz, as per technical specification. [Incomer- 2 Nos, Outgoing-4 Nos, Bus Coupler-1 and LT Transformer -2 Nos].
5536 kV, 1250A, 25 kA, 3-phase, Horizontal Double Break Isolator with earth switch.
5636 kV, 1250 A, 25 kA, 3-phase, Horizontal Double Break Isolator without earth switch.
5736 kV, 1-phase, gap less Surge Arrester complete in all respects with insulating base and surge monitor.
58CONTROL & POWER CABLE
59Armoured Power Cable (1.1 kV Grade PVC Multi-stranded Aluminium Conductor)
602 C x 6 Sq. mm
614 C x 6 Sq. mm
624 C x 16 Sq. mm
63Armoured Control Cable (1.1 kV Grade PVC multi-stranded Copper Conductor)
642 C x 2.5 Sq. mm
657 C x 2.5 Sq. mm
6610 C x 2.5 Sq. mm
6712 C x 2.5 Sq. mm
6816 C x 2.5 Sq. mm
6919 C x 2.5 Sq. mm
7033 kV, XLPE Aluminum armoured Cable and accessories as per technical specification.
7133 kV, 1C x 300 sqmm
7233 kV, 3C x 300/240 sqmm
7333 kV XLPE Cable termination equipment along with struncture & accessories for outdoor termination (one set consists for complete requirement for one bay)
74Remote Access & Communication System:
75(Optical Power Ground Wire (OPGW))
76FODP:
77FODP 48F- Indoor type, rack mounted with FCPC coupling and pig tails.
78Fiber Optical (ADDSS) Cabling:
7924 Fiber ADSS aerial (DWSM) fiber optic cable.
80Telecom equipment:
81SDH Equipment (STM-4 MADM, upto 3 MSP protected directions).
82Base equipment (Commn cards, Power Supply cards, Power cabling, other hardware & accessories i/c sub-racks, patch cards, DDF etc. fully equipped excluding ii & iii below.
83Optical interface cards / SFP:
84Optical Line interface Card (to support upto 200 kms).
85Tributary Cards:
86E1 Interface Card (Min. 16 Interface per card).
87Ethernet Interface 10/100 Base T with Layer-2 Switching Min. 8 interface per card).
88Termination equipment (Drop and insert multiplexer):
89Base equipment (Commn cards, power supply cards, power cabling other hardware & accessories i/c sub-racks, patch cards, DDF etc. Fully equipped excluding subscribed line interface cards.
90Subscriber Line Interface Cards:
912 Wire (sub / sub) voice channel cards (min.8 channels per card).
922 Wire (sub / Exch) voice channel cards (min.8 channels per card).
93Digital Access Cross Connection Switch (DACS) 16 x 16 ports switching matrix, fully equipment for min 16 E-1 Ports.
94Equipment Cabinet:
952 Wire (sub / Exch) voice channel cards (min.8 channels per card).
96Digital Access Cross Connection Switch (DACS) 16 x 16 ports switching matrix, fully equipment for min 16 E-1 Ports.
97Craft terminal:
98Hardware.
99Software.
100Network manager and element manager system:
101Hardware.
102Software.
103Printer (Laser jet).
104Main Distribution Frame (200 Pairs).
105Synchronization equipment:
106GPS clock including all hardware & accessories.
1074-points VOIP gateway
108Telephone set.
109DTPC:
110Digital Tele-Protection Coupler.
111PLCC Equipment:
112Wave Trap
113PLCC Panels
114Modular Coupling Device
115HF Cable
116Direct Current Power Supply System:
117200 AH 2V, with required numbers plus 10% spares to add to 110V DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. complete & connection with designed DC back up voltage battery set and AC input supply.
118110 V DCDB.
119200 AH 2V, with required numbers plus 10% spares to add to 48V DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. complete & connection with designed DC back up voltage battery set and AC input supply.
12048 V DCDB.
121Earthing System:
122Mat earthing for entire switchyard with 100x10 mm MS Flat iron including 32 mm dia MS Rod.
123Copper plate earthing of transformer CBS, Battery charger, etc. including cost of copper plate size 600 x 600 x 6 mm & copper strip of size 25 x 4 mm i/c salt, charcoal etc as required.
124Bus-bar Materials (Hardware Kits):
125Bus post insulators & insulator strings, Disc insulators, Hardware, Spacers, Conductor(s), bus bar materials, cable trays, Bay MB, Clamps, connectors including equipment connectors, junction box, Earthwire , Earthing materials, risers, auxiliary earth mat (excluding main earth mat), buried / RCC cable trenches/pipes for equipment & lighting, all accessories etc for the following:-
126132 /33 kV Sub-Station.
127Sub-Station Auxillaries:
128Fire Protection System:
1299 litre water type.
1304.5 kg carbon di-oxide type.
1315 kg dry chemical powder type.
132Air Conditioning:
133Split type inverter Air Conditioning Systems.
134Switchyard & Building Illumination (lighting) Systems:
135Switchyard lighting with complete cabling.
136Street lighting with complete cabling & light posts.
137Diesel Generating Set :
138100 kVA, 415 Volt with control Panel.
139Station Transformer as per ISS:
1403- Ph, 400 kVA, 33/0.433 kV, transformer.
141120 sqmm, 3.5 core XLPE cable for Station DT to LT ACDB panel.
142LT Switch Gear Systems:
143415 Volts main switchboard with panel, Fuse-switch combined unit for LT feeders.
144415 V ACDB.
145Civil Works associated with equipment foundation:
146Steel rods of all sizes for RCC works as per design.
147Civil Works for masonary enclosure for equipment earthing:
148Cast iron cover of size 650x650 mm along with base for masonry enclosure.
149Power Transformer Fire Protection CC Wall:
150Steel reinforcement of appropriate size.
151Sub-Station Land Development:
152Gravel filling two layer of 100 mm with 10 mm (minimum 100 mm thick) upgraded normal size pebbles and one layer of 100 mm sand filling in switchyard area as per technical specification.
153SH-III: MANDATORY SPARES
154132 kV Equipment:
155145 kV, 3-φ, Circuit Breaker with accessories.
156145 kV, 600 A, 31.5 kA, 1- Phase, 3- core current transformer with 120% extended current rating complete in all respects along with associated accessories and a common MB (Set of 3 Nos.).
157145 kV, 1250 A, 31.5 kA, 3- Phase Horizontal Centre Break Isolator with earth switch.
158145 kV, 1250 A, 31.5 kA, 3- Phase Horizontal Centre Break Isolator without earth switch.
159120 kV, 1-Phase, gapless Surge Arrester complete in all respects with insulating base and surge monitor.
160132 kV 1-Φ Capacitive Voltage Transformer (CVT) with accessories (Set of 3 Nos.)
16133 kV Gas Insulated Switchgear (GIS):
162Solenoid for Blocking Coil on Earthing Switch
163Auxiliary Switch for Circuit Breaker
164Auxiliary Contact on Close Trip Push button
165Blocking Coil Circuit Breaker
166Solenoid cpl. for Shunt Closing Release
167Solenoid cpl. for Shunt Tripping Release
168Solenoid cpl. for Shunt Tripping Release
169Hand Crank for Circuit Breaker
170Pressure Relief
171Auxiliary Switch Disconnector and Earthing Switch Attachment BB top
172O-ring for Bottom cable tank with Single Phase Bushing
173O-ring for Inspection cover at Bottom cable tank
174O-ring for Outer Cone Bushing
175O-ring for busbar tank cover width 600 mm
176Desiccant Attachment Busbar
177Desiccant Attachment CB Compartment
178Cam-Disc
179PT Bushing size 2
180O-ring for PT Bushing
181Bearing block
182SF6 gas leakage detector
18333 kV Power Cable termination kit.
184Armoured Control Cable (1.1 kV grade PVC multi-stranded Copper Conductor)
1854C x 2.5 Sq.mm
1867C x 2.5 Sq.mm
187Armoured Power Cable (1.2 kV Grade PVC Multi-stranded Aluminium Conductor)
1884C x 6 Sq.mm
189132 kV Transmission Line:
190ACSR Panther Conductor for 132 kV Transmission Line.
191132 kV 120 kN Composite Polymer Insulator (Tension) as per ISS
192Single tension 120 kN hardware fittings with all accessories as per ISS for Panther.
193Double tension 120 kN hardware fittings with all accessories as per ISS for Panther.
194Midspan compression joints for Panther.
195Repair Sleeve for ACSR Panther conductor.
196Vibration Damper for ACSR Panther conductor.
197ERECTION SERVICES:
198SH-I: 132 KV LILO DOUBLE CIRCUIT TRANSMISSION LINE:-
199Survey:
200Detailed survey including route alignment profiling, tower spotting & final check survey.
201Check survey.
202Soil Investigation:
203All kinds of soil except the following classifications.
204Fissured rock with mixed soil.
205Hard soil with Fissured Rock.
206Tower Foundation Works:
207Benching & Excavation works:
208Excavation in Hill Area in Soil by Mechanical Means (Excavation in soil in hilly area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres).
209Excavation in Hilly Area in Ordinary Rock by Mechanical Means not Requiring Blasting. (Excavation in hilly area in ordinary rock not requiring ballasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres).
210Pit excavation:
211All kind of soil except the following classification.
212Fissured Rock with mixed soil.
213Hard soil with Fissured Rock.
214Hard Rock.
215Concreting:
216Design & Concreting of Tower footing work on 100% full rate (i.e. Supply & erection of RCC works with cement & concrete) excluding cost of reinforcement steel:
217Normal mix Ratio 1:2:4 for M15 compressive strength.
218Plain Cement Concrete (PCC) work at base of Tower footings on 100 % full rate at nominal ratio of 1:3:6 or minimum M10 Compressive strength.
219Steel rods of all sizes for RCC works as per design.
220Pavement (Protection of Tower):
221Random rubble stone masonry i/c excavation (with 1:4:8 mixture).
222Stone bound in galvanized wire netting i/c excavation.
223Back filling and levelling of volumes enclosed in revetment.
224Concrete for top seal cover of pavement mix ratio:1:2:4 (M15)
225Erection of Tower parts:
226Erection of various types of towers and its body leg extension set (complete) i/c tuck and nuts, step bolts, hangers, D-shackles etc and i/c tuck welding and supply & application of enamel and Zinc rich paint.
227Safety Alert System:
228Danger Plates of size 250 mm x 200 mm of thickness 3 mm.
229Number Plate of size 250 mm x 200 mm of thickness 3 mm.
230Phase plate (set of three pieces).
231Anti climbing devices with G.I. Thornwire/ Barbed wires.
232Stringing of line and accessories:
233Stringing of Double circuit transmission line, (Six ACSR Panther Conductor) installation of insulator strings (complete fitting) with arcing horns and necessary hardware fitting, (i/c fixing of accessories for power line and OPGW Conductors).
234Hill Road Transportation & Head Loading:
235Transportation from Designated Bare store (DBS) at Assam-Arunachal boarders to the last road head. (80 MT x 140 km).
236Transportation of Materials by head loading from road head to the site of work. Beyond a lead of 100 meters from road to the head load end point payable extra for head load (80 x 150mtr.)
237SH-II: 132/33 KV, 2x10 MVA SUB-STATION:
238SURVEY & INVESTIGATION:
239Soil Investigation:
240All kinds of soil except the following classifications.
241Fissured rock with mixed soil.
242Hard soil with fissured rock.
243Galvanised Iron Structure:
244Design, fabrication and supplying of hot-dipped GI lattice type tower made with angle iron for 132 kV and 33 kV gantry towers and switchyard equipments support structures.
245Galvanizing Stubs, template Nuts & Bolts, spring washers etc. as reqd.
246132 kV Switchyard Equipment:
2473Ф, 10 MVA, 132/33 kV Transformer.
248Nitogen Injection Fire Protection System (NIFPS)
249Online insulating oil drying system (Catridge type).
250145 kV, SF6, 3- Phase, Circuit Breaker, with support structure.
251145 kV, 600 A, 31.5 kA, 1- phase, 3- Core current transformer with 120% extended current rating complete in all respects, along with associated accessories and a common MB. (Set of 3 Nos.)
252145 kV, 1250 A, 31.5 kA, 3- Phase Horizontal Centre Break Isolator with earth switch.
253145 kV, 1250 A, 31.5 kA, 3- phase Horizontal Centre Break Isolator without earth switch.
254145 kV, 1250 A, 31.5 kA, 3- phase Horizontal Centre Break Isolator without earth switch (Tandem).
255120 kV, 1-phase, gapless Surge Arrester, rating (kV rms) - 120, complete in all respects with insulating base and surge monitor
256132 kV, 1-Phase, Capacitive Voltage Transformer with accessories complete in all respect. (Set of 3 Nos.)
257132 kV Control, Relay and Protection Panels:
258Control & Relay panel for line Bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories.
259Control & Relay panel for Transformer Bay with differential, overfluxing, LBB and backup protective relays and other auxiliary relays as required with SAS and all associated accessories.
260Control & Relay panel for bus coupler bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories.
261Sub-Station Automation:
262Substation Automation System (SAS) confirning IS 61850 with BCU and other complete associated equipment and accessories.
263Remote Terminal Unit and SCADA Gateway with all required ancilliary equipment/materials.
26433 kV Equipment:
26533 kV Gas Insulated Switchgear, 1250 A, 31.5 kA for 3 Sec, 50 Hz, as per technical specification.[Incomer- 2 Nos, Outgoing-4 Nos, Bus Coupler-1 and LT Transformer -2 Nos].
26636 kV, 1250A, 25 kA, 3-Phase, Horizontal Double Break Isolator with earth switch.
26736 kV, 1250 A, 25 kA, 3-Phase, Horizontal Double Break Isolator without earth switch
26836 kV, 1-Phase, gap less Surge Arrester complete in all respects with insulating base and surge monitor.
269Control & Power Cable:
270Armoured Power Cable (1.1 kV Grade PVC multi-stranded Aluminium Conductor):
2712 C x 6 Sq. mm
2724 C x 6 Sq. mm
2734 C x 16 Sq. mm
274Armoured Control Cable (1.1 kV Grade PVC multi-stranded Copper Conductor):
2752 C x 2.5 Sq. mm
2767 C x 2.5 Sq. mm
27710 C x 2.5 Sq. mm
27812 C x 2.5 Sq. mm
27916 C x 2.5 Sq. mm
28019 C x 2.5 Sq. mm
28133 kV, XLPE Aluminum armoured Cable and accessories as per technical specification:
28233 kV, 1C x 300 sqmm
28333 kV, 3C x 300/240 sqmm
28433 kV XLPE Cable termination equipment along with structure & accessories for outdoor termination (one set consists for complete requirement for one bay)
285Remote Access & Communication System:
286Integration of Hardware systems with last mile connections with Optical Power Ground Wire and Optical Fiber Cables in each Sub Station.
287Telecom equipment:
288Installation of various Telecom Equipments, Software and Integrating all the Systems, Testing, Commissioning and Operationalising them in each Sub Station.
289Tributary Cards:
290E1 Interface Card (Min. 16 Interface per card).
291Ethernet Interface 10/100 Base T with Layer-2 Switching Min. 8 interface per card).
292Termination equipment (Drop and insert multiplexer):
293Base equipment (Commn cards, power supply cards, power cabling other hardware & accessories i/c sub-racks, patch cards, DDF etc. Fully equipped excluding subscribed line interface cards.
294Subscriber Line Interface Cards:
2952 Wire (sub / sub) voice channel cards (min.8 channels per card).
2962 Wire (sub / Exch) voice channel cards (min.8 channels per card).
297Digital Access Cross Connection Switch (DACS) 16 x 16 ports switching matrix, fully equipment for min 16 E-1 Ports.
298Equipment Cabinet:
299For SDH Equipment (including DDF patching facilities) for Primary Multiplex & other accessories.
300For DACS / Mux Equipment.
301Craft terminal:
302Hardware.
303Software.
304Network manager and element manager system:
305Hardware.
306Software.
307Printer (Laser jet).
308Main Distribution Frame (200 Pairs).
309Synchronization equipment:
310GPS clock including all hardware & accessories.
311PABX.
3124-points VOIP gateway.
313Telephone set.
314DTPC:
315Digital Tele-Protection Coupler.
316PLCC Equipment:
317Wave Trap.
318PLCC Panel.
319Modular Coupling Device.
320HF Cable.
321Direct Current Power Supply System:
322200 AH, 2V, with required numbers plus 10% spares to add to 110 V DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. completed & connection with designed DC back up voltage battery set and AC input supply.
323110 V DCDB.
324200 AH, 2V, with required numbers plus 10% spares to add to 48 V DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. complete & connection with designed DC back up voltage battery set and AC input supply.
32548 V DCDB.
326Earthing System:
327Mat earthing for entire switchyard with 100x10 mm MS Flat iron including 32 mm dia MS Rod.
328Copper plate earthing of transformer CBS, Battery charger, etc. including cost of copper plate size 600 x 600 x 6 mm & copper strip of size 25 x 4 mm i/c salt, charcoal etc as required.
329Bus Bar Materials ( Hardware Kits):
330Bus post insulators & insulator strings, Disc insulators, Hardware, Spacers, Conductor(s), bus bar materials, cable trays, Bay MB, Clamps, connectors including equipment connectors, junction box, Earthwire , Earthing materials, risers, auxiliary earth mat (excluding main earth mat), buried / RCC cable trenches/pipes for equipment & lighting, all accessories etc for the following:-
331132 /33 kV Sub-Station.
332Sub-Station Auxillaries:
333Fire Protection System:
3349 litre water type.
3354.5 kg carbon di-oxide type.
3365 kg dry chemical powder type.
337Air Conditioning:
338Split type inverter Air Conditioning Systems.
339Switch yard & Building illumination (Lighting) System:
340Switchyard lighting with complete cabling.
341Street lighting with complete cabling & light posts.
342Diesel Generating Set 100 kVA, 415 Volt with control Panel.
343Station Transformer:
3443- Ph, 400 kVA, 33/0.433 kV, transformer.
345120 sqmm, 3.5 core XLPE cable for Station DT to LT ACDB panel.
346LT Switchgear System:
347415 Volts main switchboard with panel, Fuse-switch combined unit for LT feeders.
348415 V ACDB.
349Civil Works:
350Civil works associated with equipment foundation:
351Excavation works:
352All kind of soil except the following classification.
353Fissured Rock with mixed soil.
354Hard soil with fissured rock.
355Design & Concreting of equipment footing work on 100% full rate (i.e. Supply & erection of RCC works with cement & concrete) excluding cost of reinforcement steel:
356Normal mix Ratio1:2:4 for M15 compressive strength.
357Plain Cement Concrete (PCC) work at base of equipment footings on 100 % full rate at nominal ratio of 1:3:6 or minimum M10 Compressive strength.
358Supply & erection of steel rods of all sizes for RCC works as per design.
359Brick Work with best available local bricks in foundation and plinth in cement mortar 1:4 (1 Cement: 4 Sand).
360Civil works for masonry enclosure for equipment earthing:
361Half Brick masonry with best available local brick in cement mortar 1:4 (1 Cement: 4 Coarse Sand) in foundation and plinth.
36212 mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand).
363Cast iron cover of size 650x650 mm along with base for masonry enclosure.
364Cable Trenches:
365Cable trenches with 1:2:4 PCC work including supply and fabrication of 4 mm steel cover as per design of following sections:-
366Section 75cm x 75cm x 10cm (depth x width x thickness).
367Section 75cm x 100cm x 10cm (depth x width x thickness).
368Section 100cm x 150cm x 10cm (depth x width x thickness).
369Other Allied Civil Works:
370Design, Engineering and construction of approach road and foot path on 100% full rate i/c T&P, Labour, cement, reinforcement steel, bricks, stone, sand, single earth bitumen and form work, excavation compaction, etc. all complete as per approved design and drawing or as may be required:-
371Roads 3.75 m wide (including all crossings) Black topped with broken as aggregate with Hot or Cold bitumen (8cm thick) over RBM base of 10 Cm (Within Substation Premises).
3721:2:4 ratio M 15 compression strength PCC path in switch yard (Thickness of cement concrete 8 cm and of RBM base 10 cm).
3731:3:6 M 10 compression strength Water Drainage as per design in PCC works.
374Security wall around the sub station (Brick wall with M15 RCC pillar) on 100% full rate base.
375Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring, shuttering and reinforcement in:
376M20 (1 cement : 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size).
377Power Transformer Fire protection CC Wall:
378Design and concreting of CC wall of 1:2:4 (M15) compression strength.
379Supply & Erection of steel reinforcement of appropriate size.
380Sub-Station Land Development:
381Jungle clearance, earth cutting/benching, levelling and removal of debris.
382Gravel filling two layer of 100 mm with 10 mm (minimum 100 mm thick) upgraded normal size pebbles and one layer of 100 mm sand filling in switchyard area as per technical specification.
383Building Works:
384Control Room:
385Design, Engineering and construction of RCC structured, Control Room with glass panels on aluminium frames i/c glazing, false ceiling, tiled floors Electrification ( Conceal Conduit), Water supply, Air Conditioning, Battery Room, Office Room, One bed room with toilet and kitchen fully fitted and furnished with fitting furniture, complete as per approved drawing for the estimate area of 150 to 300 sqm. or as per approved design and plinth area for direct use (Details as per TS) on 100% full rate basis.
386RCC structure, DG set room with brick wall & rolling shutters annexed to the control room with cable connections to the systems (Approx.- 20 sqm.) on 100% full rate basis.
387Residential Building:
388Design, Engineering and Construction of RCC structure, tiled floors, brick walled, ceiling, steel trusses and Durashine zinc-aluminium alloy coated sheet roofing/ridges residential building complete in all respect including electrification, water supply with all fitting and fixtures, furnished for direct move in:-
389Type-IV, 1 No. as per plinth area (Single Unit).
390Type-III, 2 Nos. as per plinth area (Single Unit).
391Type-II, 4 Nos. as per plinth area (G+1, 1 No.).
392Type-I, 10 Nos. as per plinth area (G+2, 2 Nos).
393Hill Road Transportation & Head Loading:
394Transportation from Designated Bare store (DBS) at Assam-Arunachal boarders to the last road head. (250 MT x 140 Km). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58385232
AUTHORITY Government Departments
TENDER VALUE 64.08 Crore
LAST DATE 27-11-2026
Authority
Authority Name Department Of Power
Work Description Tender for Establishment Of 132/33 Kv, 2X10 Mva Sub-Station At Wakro With Associated 132 Kv Lilo Line.
Basic Detail
Tender No CE(P)/TPMZ/eNIT/2026-27/02
Bidding Type Tender
Location
City Lohit
State Arunachal Pradesh
Key Dates
Publish Date 05 Nov 2026
Submission Date 27 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 64.08 Crore
Tender Fee Ref. Documents
EMD 1.28 Crore
Exemption Available
Document List
52754f97-7039-4352-9f8d-a90c96844c28.html
BOQ_3994.xls
PART_I.pdf
PART_II.pdf
PART_III_VOL_1.pdf
PART_III_VOL_2.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

52754f97-7039-4352-9f8d-a90c96844c28.html

xls

BOQ_3994.xls

pdf

PART_I.pdf

pdf

PART_II.pdf

pdf

PART_III_VOL_1.pdf

pdf

PART_III_VOL_2.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender