Tender For Tender**: Construction Of 400 Kv Ais Substation, Khurpiya Farm With Its Associated Lines
Tender Value
Ref. Documents
Estimated cost
Bid Submission
09 Dec 2026
29 days left
EMD
5.84 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Tender**: Construction Of 400 Kv Ais Substation, Khurpiya Farm With Its Associated Lines
BOQ
| Sl. No. | Item Description |
| 1 | Please Enable Macros to View BoQ information Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 400 kV AIS Substation, Khurpiya Farm with its associated Lines\\" Contract No: PTCUL/E-Tender/C&P-II/SS-22/2026-27 |
| 2 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SI. No. Description of Material Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 3 | Price Schedule-A-1 (Supply) for 400/220/132/33kV AIS SUBSTATION, KHURPIYA FARM |
| 4 | Transformer |
| 5 | 500MVA 400/220/33kV, Three phase Transformer including first filling of oil, alongwith Fibre Optic Temperature Measurement System with all associated accessories. |
| 6 | 160MVA, 220/132/11kV, Three phase Transformer including first filling of oil, Fibre Optic Temperature Measurement System and with all associated accessories. |
| 7 | 80MVA, 132/33kV, Three phase Transformer including first filling of oil, Fibre Optic Temperature Measurement System and with all associated accessories. |
| 8 | 125 MVAR 400kV, Bus Reactor including first filling of oil, alongwith Fibre Optic Temperature Measurement System and all related equipments. |
| 9 | Online DGA Multigas type for above 500MVA, 160MVA and 80MVA Transformers and Reactor. |
| 10 | Nitrogen Injection Fire Prevention & Extinguishing System for above 500MVA, 160MVA and 80MVA Transformers. |
| 11 | Oil Storage Tank (15kL) |
| 12 | Oil sampling Bottle, Stainless Steel 2 ltrs capacity. |
| 13 | LT Transformers |
| 14 | 800KVA, 33/0.433kV, Three phase Transformer including bushing, accessories and first filling of Oil (fresh oil) |
| 15 | 420kV Equipments |
| 16 | 420kV, SF6 Circuit Breakers (3 Ph. along with support Structure) |
| 17 | 3150A, 40KA with closing resistor |
| 18 | Current Transformer 5 Core with Junction Box (1 Ph.) * |
| 19 | 3150A, 40KA with 120% extended current rating |
| 20 | Capacitive Voltage Transformer with Junction Box (1 Ph.) |
| 21 | 4400pF |
| 22 | Isolators 420kV (3-phase) (Horizontal Double break) |
| 23 | Isolator with One E/S |
| 24 | 390kV Surge Arrester |
| 25 | 400kV Bus Post Insulators |
| 26 | 400kV Hardware |
| 27 | Insulator strings, Disc Insulators, Hardwar, conductor, 4 Inch IPS Al Tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following |
| 28 | Line Feeder Bay |
| 29 | Transformer Bay |
| 30 | Reactor Bay |
| 31 | Bus Works (for Tie Bays Scheme) |
| 32 | 245kV Equipments |
| 33 | 245kV SF6 Circuit breakers (3 Ph.) along with support structure |
| 34 | 245kV (5 Core) Current Transformer (1 Ph.) |
| 35 | For Line, BC, TBC |
| 36 | For 400/220kV Transformer LV side |
| 37 | For 220/132kV Transformer HV side |
| 38 | Junction Box for above CT |
| 39 | 245kV Capacitive Voltage Transformer (1 Ph.) |
| 40 | Junction box for above CVT |
| 41 | 245kV Isolators (3-phase) |
| 42 | Isolator with one E/S |
| 43 | Isolator with two E/S |
| 44 | Tandem Isolator |
| 45 | 198kV Surge Arrestors |
| 46 | 245 kV Bus Post Insulators |
| 47 | 220kV Hardware |
| 48 | Insulator strings, Disc Insulators, Hardware Fittings, Conductor, 4\\" IPS Aluminium Tube, Bus-Bar material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing material etc. for the following: |
| 49 | 220kV 2 Main + 1 Transfer |
| 50 | 220kV |
| 51 | Line Feeder Bay |
| 52 | Transformer Bay (400/220kV LV side & 220/132kV HV side) |
| 53 | Transfer Bus Coupler Bay |
| 54 | Bus Coupler Bay |
| 55 | Bus Works (for three Bus) |
| 56 | 145kV Equipment |
| 57 | 145kV SF6 Circuit breakers (3 Ph.), 1600A,40kA along with support structure |
| 58 | 145kV (5 Core) Current Transformer (1 Ph.) |
| 59 | For Line Feeder |
| 60 | For 220kV Transformer LV |
| 61 | For 132kV Transformer HV |
| 62 | Junction box for above CT |
| 63 | 145kV Capacitive Voltage Transformer (1 Ph.) |
| 64 | Junction box for above CVT |
| 65 | 145kV Isolators (3-phase) |
| 66 | Isolator with E/S |
| 67 | Isolator without E/S |
| 68 | Isolator without E/S (Tandem) |
| 69 | 120kV Surge Arrestors |
| 70 | 145kV Bus Post Insulators |
| 71 | 132kV Hardware |
| 72 | Insulator strings, Disc Insulators, Hardware Fittings, Conductor, 4\\" IPS Aluminium Tube, Bus-Bar material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing material etc. for the following: |
| 73 | 132kV 1 Main+1 Transfer |
| 74 | 132kV |
| 75 | Line Feeder Bay |
| 76 | Transformer Bay (220/132kV LV side & 132/33kV HV side) |
| 77 | Bus Coupler Bay |
| 78 | Bus Works (for two bus ) |
| 79 | 36kV Equipments |
| 80 | 33kV Isolator (3-Ph) |
| 81 | Without E/S |
| 82 | With E/S |
| 83 | 33kV Circuit Breaker |
| 84 | Current Transformer |
| 85 | 33kV Current Transformer (single phase) for Transformer with Junction Box |
| 86 | 33kV Current Transformer (single phase) for Line with Junction Box |
| 87 | 30kV Surge Arrestor |
| 88 | 33kV PT (single phase) |
| 89 | Junction Box for PT |
| 90 | 33kV Bus Post Insulators/Solid core insulator |
| 91 | Capacitor bank |
| 92 | 2*10 MVAR Capacitor bank |
| 93 | 33kV Circuit Breaker |
| 94 | 33kV Isolator with earth link |
| 95 | 33kV Isolator without earth link |
| 96 | Single phase Reactor |
| 97 | 33kV NCT |
| 98 | 33kV CT |
| 99 | 33kV Control and relay panel (for Capacitor Bank) |
| 100 | 33kV Hardware |
| 101 | Insulator strings, Disc Insulators, Hardware Fittings, Conductor, 4\\" IPS Aluminium Tube, Bus-Bar material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing material etc. for the following: |
| 102 | 33kV 1 Main+1 Transfer |
| 103 | Line Feeder Bay |
| 104 | Transformer Bay 33kV |
| 105 | Bus Coupler Bay |
| 106 | Bus Works (for two Bus) |
| 107 | Capacitor bank |
| 108 | AC Kiosks |
| 109 | 400kV system |
| 110 | 220kV system |
| 111 | 132kV system |
| 112 | 33kV system |
| 113 | Substation Automation |
| 114 | Complete Substation Automation System including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications |
| 115 | Bay Control Units |
| 116 | 400kV System Main Bays |
| 117 | 400kV Tie Bays |
| 118 | 220kV system |
| 119 | 132kV system |
| 120 | 33kV system |
| 121 | Online Monitoring, Data Acquisitionand ABT Analysis System |
| 122 | ABT meters 0.2s Cl with TCPIP, Optical Communication Port (ABT Meters are the part of C&R Panel. The rates of same may be included in the rates of C&R Panel). The quantity mentioned here for Supply & Erection is for indication purpose only. |
| 123 | DCU & Accessories |
| 124 | Industrial Grade Network Switch -8 Port, unmanaged |
| 125 | UPS 2 KVA online with 30 Min back up on 100% load |
| 126 | Workstation: Application & Database server |
| 127 | Database - Microsoft SQL Server Edition (Latest) |
| 128 | MS office - Standard edition (Latest) |
| 129 | MacAfee Virus Scan Enterprise Desktop Edition (Latest) - 03 Years |
| 130 | Local Energy Monitoring Software - Professional edition |
| 131 | LAN cable (average one roll per S/S 300 Meters) Cat-06 |
| 132 | PVC conduit Pipe - 3/4\\" ISI Mark |
| 133 | Enclosure for LAN Switch |
| 134 | 4G/5G Data enable SIM |
| 135 | Cable 3 Core 2.5 Sq. mm Copper, Armored |
| 136 | SDH/MUX EQUIPMENT |
| 137 | Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input |
| 138 | SDH (STM-4 upgradable upto STM-16)/MUX base 19\\" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply. |
| 139 | OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs |
| 140 | SFP module to support upto 50 km |
| 141 | SFP module to support upto 100 km |
| 142 | Optical Amplifier/Booster equipment |
| 143 | OFC Patch Cords - (Set of 12 Nos.) |
| 144 | Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces) |
| 145 | Minimum 8 Port E1 interface card |
| 146 | Minimum 8 Port 4w E&M Interface card |
| 147 | Minimum 12 Port FXO interface card |
| 148 | Minimum 10 Port FXS interface card |
| 149 | Minimum 4 Port programmable data interface card |
| 150 | Integrated Teleprotection card (4 Commands each) |
| 151 | Engineering Order Wire Phone |
| 152 | Optical Fibre Cable for above OPGW communication |
| 153 | 400kV Control & Relay Panels |
| 154 | Circuit Breaker Control Panel |
| 155 | With Auto Reclose |
| 156 | With out Auto Reclose (Including 3Nos. Tie Breakers) |
| 157 | Line Protection Panel |
| 158 | Transformer Protection Panel (For 400/220kV HV side) |
| 159 | Reactor Protection Panel |
| 160 | Bus Bar Protection Panel |
| 161 | 400kV (Bus Bar protection) |
| 162 | 220kV Control and Relay Panels |
| 163 | Circuit Breaker Control Panel |
| 164 | With Auto Reclose |
| 165 | With out Auto Reclose |
| 166 | Line Protection Panel (Main 1+Main 2) |
| 167 | Bus Bar Protection Panel |
| 168 | 220kV (Busbar Protection) 2 Main+1 Transfer |
| 169 | Transformer Protection Panel |
| 170 | For 400/220kV LV side |
| 171 | For 220/132kV HV side |
| 172 | 132kV Control and Relay Panels |
| 173 | Circuit Breaker Control Panel |
| 174 | With Auto Reclose |
| 175 | With out Auto Reclose |
| 176 | Line Protection Panel |
| 177 | Transformer Protection Panel |
| 178 | For 220/132kV LV side |
| 179 | For 132/33kV HV side |
| 180 | 33kV Control and Relay panel |
| 181 | 33kV Triple Feeder Control and Relay Panel |
| 182 | PLCC for 400kV Line Feeder |
| 183 | Line Traps |
| 184 | 3150A, 1.0 mH, 50 kA |
| 185 | Coupling device (Phase to Phase) |
| 186 | HF Cable |
| 187 | Carrier Equipment (for Speech + Protection and for Speech + Data) |
| 188 | Speech +Protection 1 |
| 189 | Speech +Protection 2 |
| 190 | Speech + Data |
| 191 | Protection Coupler |
| 192 | PLCC for 220kV Line Feeder |
| 193 | Line Traps |
| 194 | 2000A, 0.5 mH/1.0 mH, 40 kA |
| 195 | Coupling device ( Phase to Phase ) |
| 196 | HF Cable |
| 197 | Carrier Equipment |
| 198 | for Speech + Protection (Main1 & Main2) |
| 199 | for Speech + Data |
| 200 | Protection Coupler |
| 201 | PLCC for 132kV Line Feeder |
| 202 | Line Traps |
| 203 | 2000A, 0.5 mH/1.0 mH, 40 kA |
| 204 | Coupling device ( Phase to Earth ) |
| 205 | HF Cable |
| 206 | Carrier Equipment |
| 207 | for Speech + Protection |
| 208 | for Speech + Data |
| 209 | Protection Coupler |
| 210 | EPAX (24/8) with 24 telephones, cables etc. |
| 211 | Common equipments |
| 212 | Time Synchronisation Equipment (GPS Clock) |
| 213 | Testing & Maintenance Equipment |
| 214 | Insulation Tester Meter 15kV (Motorized) |
| 215 | Insulation Tester Meter 5kV (Motorized) |
| 216 | Automatic Capacitor and Tan Delta measuring kit |
| 217 | Digital Multi Meter |
| 218 | Leakage Tester (Tong Type) |
| 219 | Selective Level Meter |
| 220 | Signal Generator |
| 221 | Micro-ohm Meter |
| 222 | Gapless Zinc Oxide LA Tester |
| 223 | Oil BDV Kit 0-100kV |
| 224 | Gas Evacuating and Refilling Plant |
| 225 | Winding Resistance Meter |
| 226 | Thermal Imaging Camera (Thermo Vision Camera) |
| 227 | Gas Leakge Monitor |
| 228 | Circuit Breaker Analyser |
| 229 | Dew Point Meter |
| 230 | Battery Earth Fault Locator |
| 231 | Primary Injection Set 1000Amp |
| 232 | Relay Test Kit |
| 233 | D-Spanner set (Insulated), Ring-Spanner set (Insulated) & Torque Wrench set. Each set shall be a complete set including all standard sizes. |
| 234 | Insulating Gloves |
| 235 | Helmets |
| 236 | Hydraulic Ladder Battery operated (Rechargable) upto 300kg capacity and 10 meters height |
| 237 | Spliced ladders 5mtr. |
| 238 | Spliced ladders 10mtr. |
| 239 | Spliced ladders 20mtr. |
| 240 | Polyamide or Braided white nylon rope 12 mm |
| 241 | Polyamide or Braided white nylon rope 14 mm |
| 242 | Polyamide or Braided white nylon rope 20 mm |
| 243 | Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements |
| 244 | Shock treatment chart & artificial respiratory system |
| 245 | First-aid box complete with first filling of required medicines, instruments and tools |
| 246 | Danger / Man on line / Break-Down boards of appropriate size |
| 247 | Rain coat, Gum boot and Safety Harness Belt with adequate straps |
| 248 | Air-conditioner |
| 249 | Split AC (Capacity-2T) Max Star rating |
| 250 | LT Switchboard |
| 251 | 415V Main Switch Board |
| 252 | 415V AC Distribution Board |
| 253 | 415V MLDB |
| 254 | 415V ELDB |
| 255 | 220V DCDB |
| 256 | 48V DCDB |
| 257 | Batteries |
| 258 | 220V, 500AH |
| 259 | 48V, 300AH |
| 260 | Battery Charger System |
| 261 | 220V, 100Amps Float and Float Cum Boost Charger |
| 262 | 48V, 60Amps Float and Float Cum Boost Charger |
| 263 | Miscellaneous Items |
| 264 | Air Curtain for Control Room Building |
| 265 | Interactive Screen for Control Room Building, Confrence Room |
| 266 | 250kVA, 440V DG Set alongwith AMF Control Panel |
| 267 | Fire Fighting Equipments |
| 268 | Fire detection and alarm system for Control room building and other rooms. |
| 269 | 50 Ltrs. Water Mist & CAFS |
| 270 | 45 Ltrs. Foam Type |
| 271 | 20 Kgs. CO2 Type |
| 272 | 4.5 Kgs. CO2 type |
| 273 | 6 Fire Bucket with stand |
| 274 | Sand Drum (half size) filled with sand |
| 275 | Fire Hut and sand pit |
| 276 | Illumination sytem |
| 277 | Outdoor Lights LED Type (Switchyard) |
| 278 | Indoor Light LED Type for Control Room, AC Kiosk and other Rooms etc. |
| 279 | Street Light, LED Type |
| 280 | Solar Light System for Street Light (LED Type Lights) with Pole and other mounting accessories |
| 281 | 1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc. |
| 282 | Power Cables Aluminium (XLPE) |
| 283 | 3.5C x 400 Sq.mm |
| 284 | 3.5C x 300 Sq.mm |
| 285 | Power Cable Aluminium (PVC) |
| 286 | 3.5C x 70 Sq.mm |
| 287 | 3.5C x 35 Sq.mm |
| 288 | 4C x 16 Sq.mm |
| 289 | 4C x 6 Sq.mm |
| 290 | Control Cable Copper (PVC) |
| 291 | 2C x 2.5 Sq.mm |
| 292 | 4C x 2.5 Sq.mm |
| 293 | 6C x 2.5 Sq.mm |
| 294 | 10C x 2.5 Sq.mm |
| 295 | Grounding/Earthing system |
| 296 | MS Round 40mm dia |
| 297 | 3 mtrs deep driven earth electrode 40mm dia |
| 298 | 3 mtrs deep pipe electrode (treated pit) |
| 299 | MS Flat 75 x 12 mm |
| 300 | MS Flat 50 x 6 mm |
| 301 | GS shield wire |
| 302 | Steel structure |
| 303 | Lattice structure (Main Structures and Auxiliary Equipments Structures) |
| 304 | Pipe structure (Auxiliary Equipments Structure) |
| 305 | Mandatory spares as per Section \\"Mandatory Spares\\" in Technical Specifications for following items:- |
| 306 | 400/220kV, 500MVA Transformer |
| 307 | 220/132kV, 160MVA Transformer |
| 308 | 132/33kV, 80MVA Transformer |
| 309 | 400kV CB |
| 310 | 400kV Isolator & ES |
| 311 | 400kV CT |
| 312 | 400kV CVT |
| 313 | 390kV LA |
| 314 | 245kV CB |
| 315 | 245kV Isolator & ES |
| 316 | 245kV CT |
| 317 | 245kV CVT |
| 318 | 198kV LA |
| 319 | 145kV CB |
| 320 | 145kV Isolator & ES |
| 321 | 145kV CT |
| 322 | 145kV CVT |
| 323 | 120kV LA |
| 324 | 33kV CB |
| 325 | 33kV Isolator & ES |
| 326 | 33kV CT |
| 327 | 33kV PT |
| 328 | 33kV LA |
| 329 | Control and Relay Panel |
| 330 | Substation Automation System |
| 331 | Illumination System |
| 332 | Fire Protection System |
| 333 | DG Set |
| 334 | Battery |
| 335 | Battery Charger |
| 336 | LT Switchgear |
| 337 | Erection hardware |
| 338 | Optical Fiber Cable |
| 339 | Price Schedule-A-2 (Supply) for Construction of LILO of 220 kV Bareilly-Pantnagar line at proposed 400 KV Substation Khurpiya Farm |
| 340 | Towers |
| 341 | Fabrication, Galvanizing & Supply of Normal Stub/Raised Chimney Stub for various type of 220 kV D/C towers with cleat including Nut & Bolts. |
| 342 | For A type tower (0o- 02o) |
| 343 | For B type tower (2o- 30o) |
| 344 | For C type tower (30o- 60o) |
| 345 | Fabrication, Galvanizing and Supply of complete 220 kV D/C lattice type towers with bolts & nuts, step bolts, pack washers, spring washers, D-shackles including Body & Leg Extensions. |
| 346 | A type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 347 | B type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 348 | C type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 349 | Supply of Galvanized templates |
| 350 | Template of A type tower including Bolts, Nuts & washers etc.(1 Nos.) |
| 351 | Template of B type tower including Bolts, Nuts & washers etc.(1 Nos.) |
| 352 | Template of C type tower including Bolts, Nuts & washers etc.(1 Nos.) |
| 353 | ACSR Zebra Conductor |
| 354 | Design and supply of hardware Fittings |
| 355 | Single Tension fitting for Single ACSR Zebra Conductor suitbale for 160 KN Disc Insulator |
| 356 | Double Tension fitting for Single ACSR Zebra Conductor suitbale for 2x160 KN Disc Insulator |
| 357 | Suspension fitting for Single ACSR Zebra Conductor suitbale for 90 KN Disc Insulator |
| 358 | Pilot fitting suitable for Single ACSR Zebra (90 KN Disc Insulator) |
| 359 | PG Clamp suitable for Single Zebra Conductor for LILO arrangments |
| 360 | Suspension fitting for OPGW / GS Earth wire 7/10 SWG |
| 361 | Accessories for conductor & earth wire |
| 362 | Vibration damper for Zebra Conductor |
| 363 | Flexible Copper Bond |
| 364 | Repair sleeve for ACSR Zebra conductor |
| 365 | Mid span compression joint for ACSR Zebra Conductor |
| 366 | Insulators |
| 367 | 220 kV, 160 KN porcelain Long rod Insualtor (02 No. 160 KN Porcelain long rod insulator for each Tension fitting) |
| 368 | 220 kV, 90 KN porcelain Long rod Insualtor (01 No. 90 KN Porcelain long rod insulator for each Supspension/Pilot fitting) |
| 369 | Supply of following tower accessories |
| 370 | Number plate |
| 371 | Danger Plate |
| 372 | Circuit Plate (set of two) |
| 373 | Phase Plate (set of three) |
| 374 | Anti-Climbing device |
| 375 | Birds Guards (set of six) |
| 376 | Pipe type earthing |
| 377 | Supply of following items for aviation requirements |
| 378 | Span markers |
| 379 | Obstruction lights (to be provided as per IS 5613) |
| 380 | 1 Medium + 2 low intensity |
| 381 | 1 Medium + 4 low intensity |
| 382 | Supply of OPGW |
| 383 | OPGW 48 Fibre - 220 KV |
| 384 | All requiered hardware such as Tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 220 KV lines |
| 385 | Vibration Damper |
| 386 | Reinforcing rod |
| 387 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 388 | Approach Cable 48 Fibre |
| 389 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 390 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 391 | Price Schedule-A-3 (Supply ) for Construction of LILO of 132 kV Kichha-Rudrapur line at Proposed 400 kV Substation Khurpiya Farm |
| 392 | Fabrication, Galvanizing & Supply of Normal Stub/Raised Chimney Stub for various type of 132 kv D/C towers with cleat including Nut & Bolts. |
| 393 | For A type tower (0o- 02o) |
| 394 | For B type tower (2o- 30o) |
| 395 | For C type tower (30o- 60o) |
| 396 | Fabrication, Galvanizing and Supply of complete 132 kV D/C lattice type towers with bolts & nuts, step bolts, pack washers, spring washers, D-shackles including Body & Leg Extensions. |
| 397 | A type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 398 | B type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 399 | C type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 400 | Supply of Galvanized templates |
| 401 | Template of A type tower including Bolts, Nuts & washers etc (1 nos.) . |
| 402 | Template of B type tower including Bolts, Nuts & washers etc (1 nos.) . |
| 403 | Template of C type tower including Bolts, Nuts & washers etc (1 nos.) . |
| 404 | ACSR Panther Conductor |
| 405 | Design and supply of hardware Fittings |
| 406 | Single Tension fitting for ACSR Panther Conductor suitbale for 120 KN Disc Insulator |
| 407 | Double Tension fitting for ACSR Panther Conductor suitbale for 120 KN Disc Insulator |
| 408 | Single Suspension fitting for ACSR Panther Conductor suitbale for 70 KN Disc Insulator |
| 409 | Double Suspension fitting for ACSR Panther Conductor suitbale for 70 KN Disc Insulator |
| 410 | Pilot fitting for ACSR Panther Conductor suitbale for 70 KN Disc Insulator |
| 411 | PG Clamp suitable for Single Panther Conductor for LILO arrangments |
| 412 | Suspension fitting for OPGW/GS Earth wire 7/10 SWG |
| 413 | Accessories for conductor & earth wire |
| 414 | Vibration damper for Panther Conductor |
| 415 | Mid span compression joint for ACSR Panther Conductor |
| 416 | Flexible Copper Bond |
| 417 | Repair sleeve for Panther Conductor |
| 418 | Insulators |
| 419 | 120 KN Disc Insulator |
| 420 | 70 KN Disc Insulator |
| 421 | 132 KV, 120 KN porcelain Long rod Insulator string (String consisting 01 No. 120 KN Porcelain long rod insulator) |
| 422 | 132 KV, 70 KN porcelain Long rod Insulator string (String consisting 01 No. 70 KN Porcelain long rod insulator) |
| 423 | Supply of following tower accessories |
| 424 | Bird Guard (set of six) |
| 425 | Danger plate |
| 426 | Number plate |
| 427 | Phase Plate (set of three) |
| 428 | Circuit Plate (set of two) |
| 429 | Anti-Climbing device |
| 430 | Pipe type earthing (set of two nos. for each tower) |
| 431 | Supply of following items for aviation requirements |
| 432 | Span markers |
| 433 | Obstruction lights (to be provided as per IS 5613) |
| 434 | 1 Medium + 2 low intensity |
| 435 | 1 Medium + 4 low intensity |
| 436 | Supply of OPGW |
| 437 | OPGW 48 Fibre - 132 KV |
| 438 | All requiered hardware such as Tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 132 KV lines |
| 439 | Vibration Damper |
| 440 | Reinforcing rod |
| 441 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 442 | Approach Cable 48 Fibre |
| 443 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 444 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 445 | Price Schedule-A-4 (Supply) for LILO of 400 kV Bareilly-Kashipur Transmission line at proposed 400 kV Substation Khurpiya Farm |
| 446 | Designing of tower and supply of Structural Drawing, Bill of Material, Single line diagram, Spotting data & Foundation design & drawings etc. |
| 447 | Designing of 400 kV D/C Lattice type narrow base tower complete in all respect with their Body extension (i.e. +3m, +6m & +9m) with Cleat, Bolts, Nuts & Washers, etc. as finalized by PTCUL includes Supply of Structural Drawing, shop floor drawings, Bill of material, Single Line Diagram and Spotting Data. |
| 448 | A type tower (0o- 02o) |
| 449 | B type tower (2o- 15o) |
| 450 | C type tower (15o- 30o) |
| 451 | D type tower (30o- 60o) |
| 452 | +30 Mtr. Body Extension suitable for D type tower (Reliabilty level-3) |
| 453 | Designing of RCC type foundations (i.e. Dry, PS, FS & Shallow type) useable for following 400 kV D/C Lattice type tower complete in all respect (separate design & drawings to be done for respective extensions) including supply of detailed foundation drawings. |
| 454 | For A type tower (0o- 02o) |
| 455 | For B type tower (2o- 15o) |
| 456 | For C type tower (15o- 30o) |
| 457 | For D type tower (30o- 60o) |
| 458 | Towers |
| 459 | Fabrication, Galvanizing & Supply of Normal Stub/Raised Chimney Stub for various type of 400 kV D/C towers with cleat including Nut & Bolts. |
| 460 | For A type tower (0o- 02o) |
| 461 | For B type tower (2o- 15o) |
| 462 | For C type tower (15o- 30o) |
| 463 | For D type tower (30o- 60o) |
| 464 | Fabrication, Galvanizing and Supply of complete 400 kV D/C lattice type towers with bolts & nuts, step bolts, pack washers, spring washers, D-shackles including Body & Leg Extensions. |
| 465 | A type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 466 | B type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 467 | C type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 468 | Galvanized D type D/C tower with Bolts, Nuts, flat washers, pack washers including 3 mtr., 6 mtr. & 9 mtr. Body Extension. |
| 469 | Supply of Galvanized templates |
| 470 | Template of A type tower including Bolts, Nuts & washers etc.(1 Nos.) |
| 471 | Template of B type tower including Bolts, Nuts & washers etc.(1 Nos.) |
| 472 | Template of C type tower including Bolts, Nuts & washers etc.(1 Nos.) |
| 473 | Template of D type tower including Bolts, Nuts & washers etc.(1 Nos.) |
| 474 | ACSR Moose Conductor |
| 475 | GS Earthwire-7/3.66 mm size |
| 476 | Design and Supply of Hardware Fittings |
| 477 | Single 'I' Suspension Pilot fitting suitable (120 KN) for Quad Moose conductor |
| 478 | Single 'I' Suspension fitting suitable (120 KN) for Quad Moose conductor |
| 479 | Tension fitting suitable for (160 KN) Quad Moose conductor |
| 480 | Tension fitting suitable for 7/3.66 mm earth wrie |
| 481 | Suspension fitting suitable for 7/3.66 mm earth wrie |
| 482 | PG Clamp suitable for Quad Moose Conductor for LILO arrangments |
| 483 | Accessories for conductor & earth wire |
| 484 | Mid span compression joint for ACSR Moose conductor |
| 485 | Midspan compression joint for 7/3.66 mm GS Earthwire |
| 486 | Repair sleeve for ACSR Moose conductor |
| 487 | Repair sleeve for 7/3.66 mm GS Earthwire |
| 488 | Flexlible Copper Bonds |
| 489 | Bundle spacer Damper for ACSR Quad Moose conductor |
| 490 | Rigid spacer for ACSR Quad Moose conductor |
| 491 | Vibration Damper for 7/3.66 mm earth wire |
| 492 | Insulators |
| 493 | 400 kV, 160 KN porcelain Long rod Insulator string (String consisting 03 No. 160 KN Porcelain long rod insulator) |
| 494 | 400 kV, 120 KN porcelain Long rod Insulator string (String consisting 03 No.120 KN Porcelain long rod insulator) |
| 495 | Supply of following tower accessories |
| 496 | Danger plate |
| 497 | Number plate |
| 498 | Phase plate (set of three) |
| 499 | Circuit plate (set of two) |
| 500 | Anti-climbing device barbed wire type |
| 501 | Bird Guard (set of six) |
| 502 | Grounding work with Pipe type earthing (set of two nos. for each tower) and backfilling excluding cost of earthing material |
| 503 | Supply of following items for aviation requirements |
| 504 | Span markers |
| 505 | Obstruction lights (to be provided as per IS 5613) |
| 506 | 1 Medium + 2 low intensity |
| 507 | 1 Medium + 4 low intensity |
| 508 | Supply of Wind Measuring Equipment |
| 509 | Supply of OPGW |
| 510 | OPGW 48 Fibre - 400 kV |
| 511 | All requiered hardware such as Tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 400 kV lines |
| 512 | Vibration Damper |
| 513 | Reinforcing rod |
| 514 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 515 | Approach Cable 48 Fibre |
| 516 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 517 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 518 | Mandatory Spares |
| 519 | 400 kV, 160 KN porcelain Long rod Insulator string (String consisting 03 No. 160 KN Porcelain long rod insulator) |
| 520 | 400 KV, 120 KN porcelain Long rod Insulator string (String consisting 03 No.120 KN Porcelain long rod insulator) |
| 521 | Tension fitting suitable for (160 KN) Quad Moose conductor |
| 522 | Single 'I' Suspension Pilot fitting suitable (120 KN) for Quad Moose conductor |
| 523 | Mid span compression joint for ACSR Moose conductor |
| 524 | Mid span compression joint for Earth wire (7/3.66 mm) |
| 525 | Rigid Spacers for Quad Moose conductor |
| 526 | Bundle Spacers Damper for Quad Moose conductor |
| 527 | Repair sleeve for ACSR Moose conductor |
| 528 | Repair sleeve for 7/3.66 mm GS Earthwire |
| 529 | Flexlible Copper Bonds |
| 530 | Tension fitting suitable for 7/3.66 mm earth wrie |
| 531 | Span marker |
| 532 | Obstruction Light (1 medium + 2 low intensity) |
| 533 | Obstruction Light (1 medium + 4 low intensity) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 400 kV AIS Substation, Khurpiya Farm with its associated Lines\\" Contract No: PTCUL/E-Tender/C&P-II/SS-22/2026-27 |
| 534 | Name of the Bidder/ Bidding Firm / Company : 1.0 PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SI.No. Description of Material Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 535 | Price Schedule-B-1 (Erection) for 400/220/132/33kV AIS SUBSTATION, KHURPIYA FARM |
| 536 | Transformers |
| 537 | 500MVA 400/220/33kV, Three phase Transformer including first filling of oil, alongwith Fibre Optic Temperature Measurement System with all associated accessories. |
| 538 | 160MVA, 220/132/11kV, Three phase Transformer including first filling of oil, Fibre Optic Temperature Measurement System and with all associated accessories. |
| 539 | 80MVA, 132/33kV, Three phase Transformer including first filling of oil, Fibre Optic Temperature Measurement System and with all associated accessories. |
| 540 | 125 MVAR 400kV, Bus Reactor including first filling of oil, alongwith Fibre Optic Temperature Measurement System and all related equipments. |
| 541 | Online DGA Multigas type for above 500MVA, 160MVA and 80MVA Transformers and Reactor. |
| 542 | Nitrogen Injection Fire Prevention & Extinguishing System for above 500MVA, 160MVA and 80MVA Transformers. |
| 543 | LT Transformers |
| 544 | 800KVA, 33/0.433kV, Three phase Transformer including bushing, accessories and first filling of Oil (fresh oil) |
| 545 | 420kV Equipments |
| 546 | 420kV, SF6 Circuit Breakers (3 Ph. along with support Structure) |
| 547 | 3150A, 40KA with closing resistor |
| 548 | Current Transformer 5 Core with Junction Box (1 Ph.) * |
| 549 | 3150A, 40KA with 120% extended current rating |
| 550 | Capacitive Voltage Transformer with Junction Box (1 Ph.) |
| 551 | 4400pF |
| 552 | Isolators 420kV (3-phase) (Horizontal Double break) |
| 553 | Isolator with One E/S |
| 554 | 390kV Surge Arrester |
| 555 | 400kV Bus Post Insulators |
| 556 | 400kV Hardware |
| 557 | Insulator strings, Disc Insulators, Hardwar, conductor, 4 Inch IPS Al Tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following |
| 558 | Line Feeder Bay |
| 559 | Transformer Bay |
| 560 | Reactor Bay |
| 561 | Bus Works (for Tie Bays Scheme) |
| 562 | 245kV Equipments |
| 563 | 245kV SF6 Circuit breakers (3 Ph.) along with support structure |
| 564 | 245kV (5 Core) Current Transformer (1 Ph.) |
| 565 | For Line, BC, TBC |
| 566 | For 400/220kV Transformer LV side |
| 567 | For 220/132kV Transformer HV side |
| 568 | Junction Box for above CT |
| 569 | 245kV Capacitive Voltage Transformer (1 Ph.) |
| 570 | Junction box for above CVT |
| 571 | 245kV Isolators (3-phase) |
| 572 | Isolator with one E/S |
| 573 | Isolator with two E/S |
| 574 | Tandem Isolator |
| 575 | 198kV Surge Arrestors |
| 576 | 245 kV Bus Post Insulators |
| 577 | 220kV Hardware |
| 578 | Insulator strings, Disc Insulators, Hardware Fittings, Conductor, 4\\" IPS Aluminium Tube, Bus-Bar material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing material etc. for the following: |
| 579 | 220kV 2 Main + 1 Transfer |
| 580 | 220kV |
| 581 | Line Feeder Bay |
| 582 | Transformer Bay (400/220kV LV side & 220/132kV HV side) |
| 583 | Transfer Bus Coupler Bay |
| 584 | Bus Coupler Bay |
| 585 | Bus Works (for three Bus) |
| 586 | 145kV Equipment |
| 587 | 145kV SF6 Circuit breakers (3 Ph.), 1600A,40kA along with support structure |
| 588 | 145kV (5 Core) Current Transformer (1 Ph.) |
| 589 | For Line Feeder |
| 590 | For 220kV Transformer LV |
| 591 | For 132kV Transformer HV |
| 592 | Junction box for above CT |
| 593 | 145kV Capacitive Voltage Transformer (1 Ph.) |
| 594 | Junction box for above CVT |
| 595 | 145kV Isolators (3-phase) |
| 596 | Isolator with E/S |
| 597 | Isolator without E/S |
| 598 | Isolator without E/S (Tandem) |
| 599 | 120kV Surge Arrestors |
| 600 | 145kV Bus Post Insulators |
| 601 | 132kV Hardware |
| 602 | Insulator strings, Disc Insulators, Hardware Fittings, Conductor, 4\\" IPS Aluminium Tube, Bus-Bar material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing material etc. for the following: |
| 603 | 132kV 1 Main+1 Transfer |
| 604 | 132kV |
| 605 | Line Feeder Bay |
| 606 | Transformer Bay (220/132kV LV side & 132/33kV HV side) |
| 607 | Bus Coupler Bay |
| 608 | Bus Works (for two bus ) |
| 609 | 36kV Equipments |
| 610 | 33kV Isolator (3-Ph) |
| 611 | Without E/S |
| 612 | With E/S |
| 613 | 33kV Circuit Breaker |
| 614 | Current Transformer |
| 615 | 33kV Current Transformer (single phase) for Transformer with Junction Box |
| 616 | 33kV Current Transformer (single phase) for Line with Junction Box |
| 617 | 30kV Surge Arrestor |
| 618 | 33kV PT (single phase) |
| 619 | Junction Box for PT |
| 620 | 33kV Bus Post Insulators/Solid core insulator |
| 621 | Capacitor bank |
| 622 | 2*10 MVAR Capacitor bank |
| 623 | 33kV Circuit Breaker |
| 624 | 33kV Isolator with earth link |
| 625 | 33kV Isolator without earth link |
| 626 | Single phase Reactor |
| 627 | 33kV NCT |
| 628 | 33kV CT |
| 629 | 33kV Control and relay panel (for Capacitor Bank) |
| 630 | 33kV Hardware |
| 631 | Insulator strings, Disc Insulators, Hardware Fittings, Conductor, 4\\" IPS Aluminium Tube, Bus-Bar material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing material etc. for the following: |
| 632 | 33kV 1 Main+1 Transfer |
| 633 | Line Feeder Bay |
| 634 | Transformer Bay 33kV |
| 635 | Bus Coupler Bay |
| 636 | Bus Works (for two Bus) |
| 637 | Capacitor bank |
| 638 | AC Kiosks |
| 639 | 400kV system |
| 640 | 220kV system |
| 641 | 132kV system |
| 642 | 33kV system |
| 643 | Substation Automation |
| 644 | Complete Substation Automation System including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications |
| 645 | Bay Control Units |
| 646 | 400kV System Main Bays |
| 647 | 400kV Tie Bays |
| 648 | 220kV system |
| 649 | 132kV system |
| 650 | 33kV system |
| 651 | Online Monitoring, Data Acquisitionand ABT Analysis System |
| 652 | ABT meters 0.2s Cl with TCPIP, Optical Communication Port (ABT Meters are the part of C&R Panel. The rates of same may be included in the rates of C&R Panel). The quantity mentioned here for Supply & Erection is for indication purpose only. |
| 653 | DCU & Accessories |
| 654 | Industrial Grade Network Switch -8 Port, unmanaged |
| 655 | UPS 2 KVA online with 30 Min back up on 100% load |
| 656 | Workstation: Application & Database server |
| 657 | Database - Microsoft SQL Server Edition (Latest) |
| 658 | MS office - Standard edition (Latest) |
| 659 | MacAfee Virus Scan Enterprise Desktop Edition (Latest) - 03 Years |
| 660 | Local Energy Monitoring Software - Professional edition |
| 661 | LAN cable (average one roll per S/S 300 Meters) Cat-06 |
| 662 | PVC conduit Pipe - 3/4\\" ISI Mark |
| 663 | Enclosure for LAN Switch |
| 664 | 4G/5G Data enable SIM |
| 665 | Cable 3 Core 2.5 Sq. mm Copper, Armored |
| 666 | Integration of station metering system with centrlized data system including all hardware and software required. |
| 667 | SDH/MUX EQUIPMENT |
| 668 | Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input |
| 669 | SDH (STM-4 upgradable upto STM-16)/MUX base 19\\" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply. |
| 670 | OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs |
| 671 | SFP module to support upto 50 km |
| 672 | SFP module to support upto 100 km |
| 673 | Optical Amplifier/Booster equipment |
| 674 | OFC Patch Cords - (Set of 12 Nos.) |
| 675 | Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces) |
| 676 | Minimum 8 Port E1 interface card |
| 677 | Minimum 8 Port 4w E&M Interface card |
| 678 | Minimum 12 Port FXO interface card |
| 679 | Minimum 10 Port FXS interface card |
| 680 | Minimum 4 Port programmable data interface card |
| 681 | Integrated Teleprotection card (4 Commands each) |
| 682 | Engineering Order Wire Phone |
| 683 | Optical Fibre Cable for above OPGW communication |
| 684 | 400kV Control & Relay Panels |
| 685 | Circuit Breaker Control Panel |
| 686 | With Auto Reclose |
| 687 | With out Auto Reclose (Including 3Nos. Tie Breakers) |
| 688 | Line Protection Panel |
| 689 | Transformer Protection Panel (For 400/220kV HV side) |
| 690 | Reactor Protection Panel |
| 691 | Bus Bar Protection Panel |
| 692 | 400kV (Bus Bar protection) |
| 693 | 220kV Control and Relay Panels |
| 694 | Circuit Breaker Control Panel |
| 695 | With Auto Reclose |
| 696 | With out Auto Reclose |
| 697 | Line Protection Panel (Main 1+Main 2) |
| 698 | Bus Bar Protection Panel |
| 699 | 220kV (Busbar Protection) 2 Main+1 Transfer |
| 700 | Transformer Protection Panel |
| 701 | For 400/220kV LV side |
| 702 | For 220/132kV HV side |
| 703 | 132kV Control and Relay Panels |
| 704 | Circuit Breaker Control Panel |
| 705 | With Auto Reclose |
| 706 | With out Auto Reclose |
| 707 | Line Protection Panel |
| 708 | Transformer Protection Panel |
| 709 | For 220/132kV LV side |
| 710 | For 132/33kV HV side |
| 711 | 33kV Control and Relay panel |
| 712 | 33kV Triple Feeder Control and Relay Panel |
| 713 | PLCC for 400kV Line Feeder |
| 714 | Line Traps |
| 715 | 3150A, 1.0 mH, 50 kA |
| 716 | Coupling device (Phase to Phase) |
| 717 | HF Cable |
| 718 | Carrier Equipment (for Speech + Protection and for Speech + Data) |
| 719 | Speech +Protection 1 |
| 720 | Speech +Protection 2 |
| 721 | Speech + Data |
| 722 | Protection Coupler |
| 723 | PLCC for 220kV Line Feeder |
| 724 | Line Traps |
| 725 | 2000A, 0.5 mH/1.0 mH, 40 kA |
| 726 | Coupling device ( Phase to Phase ) |
| 727 | HF Cable |
| 728 | Carrier Equipment |
| 729 | for Speech + Protection (Main1 & Main2) |
| 730 | for Speech + Data |
| 731 | Protection Coupler |
| 732 | PLCC for 132kV Line Feeder |
| 733 | Line Traps |
| 734 | 2000A, 0.5 mH/1.0 mH, 40 kA |
| 735 | Coupling device ( Phase to Earth ) |
| 736 | HF Cable |
| 737 | Carrier Equipment |
| 738 | for Speech + Protection |
| 739 | for Speech + Data |
| 740 | Protection Coupler |
| 741 | EPAX (24/8) with 24 telephones, cables etc. |
| 742 | Common equipments |
| 743 | Time Synchronisation Equipment (GPS Clock) |
| 744 | Air-conditioner |
| 745 | Split AC (Capacity-2T) Max Star rating |
| 746 | LT Switchboard |
| 747 | 415V Main Switch Board |
| 748 | 415V AC Distribution Board |
| 749 | 415V MLDB |
| 750 | 415V ELDB |
| 751 | 220V DCDB |
| 752 | 48V DCDB |
| 753 | Batteries |
| 754 | 220V, 500AH |
| 755 | 48V, 300AH |
| 756 | Battery Charger System |
| 757 | 220V, 100Amps Float and Float Cum Boost Charger |
| 758 | 48V, 60Amps Float and Float Cum Boost Charger |
| 759 | Miscellaneous Items |
| 760 | Air Curtain for Control Room Building |
| 761 | Interactive Screen for Control Room Building, Confrence Room |
| 762 | 250kVA, 440V DG Set alongwith AMF Control Panel |
| 763 | Fire Fighting Equipments |
| 764 | Fire detection and alarm system for Control room building and other rooms. |
| 765 | 50 Ltrs. Water Mist & CAFS |
| 766 | Fire Hut and sand pit |
| 767 | Illumination sytem |
| 768 | Outdoor Lights LED Type (Switchyard) |
| 769 | Indoor Light LED Type for Control Room, AC Kiosk and other Rooms etc. |
| 770 | Street Light, LED Type |
| 771 | Solar Light System for Street Light (LED Type Lights) with Pole and other mounting accessories |
| 772 | 1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc. |
| 773 | Power Cables Aluminium (XLPE) |
| 774 | 3.5C x 400 Sq.mm |
| 775 | 3.5C x 300 Sq.mm |
| 776 | Power Cable Aluminium (PVC) |
| 777 | 3.5C x 70 Sq.mm |
| 778 | 3.5C x 35 Sq.mm |
| 779 | 4C x 16 Sq.mm |
| 780 | 4C x 6 Sq.mm |
| 781 | Control Cable Copper (PVC) |
| 782 | 2C x 2.5 Sq.mm |
| 783 | 4C x 2.5 Sq.mm |
| 784 | 6C x 2.5 Sq.mm |
| 785 | 10C x 2.5 Sq.mm |
| 786 | Grounding/Earthing system |
| 787 | MS Round 40mm dia |
| 788 | 3 mtrs deep driven earth electrode 40mm dia |
| 789 | 3 mtrs deep pipe electrode (treated pit) |
| 790 | MS Flat 75 x 12 mm |
| 791 | MS Flat 50 x 6 mm |
| 792 | GS shield wire |
| 793 | Steel structure |
| 794 | Lattice structure (Main Structures and Auxiliary Equipments Structures) |
| 795 | Pipe structure (Auxiliary Equipments Structure) |
| 796 | Support for Operation & Maintenance (O&M) of Substation, Troubleshooting & familiarization of PTCUL staff with the installed system for a period of 06 (Six) months by deploying adequate number (Minimum 02) of qualified persons round the clock. |
| 797 | Price Schedule-B-2 (Erection) for Construction of LILO of 220 kV Bareilly-Pantnagar line at proposed 400 KV Substation Khurpiya Farm |
| 798 | Part-1 |
| 799 | Survey |
| 800 | Detailed route Survey, Profiling, Alignment etc. including prepration of Tower schedule, Optimisation of tower locations etc and prepration of forest case (if any) complete in all respect |
| 801 | Check survey and final peg marking |
| 802 | Soil Investigation |
| 803 | Part-2 |
| 804 | Setting of Stubs, inlcuding all foundation work but excluding the cost of concreting and excavation |
| 805 | A type Double Circuit (0o- 2o ) tower |
| 806 | B type Double Circuit (2o- 30o ) tower |
| 807 | C type Double Circuit (30o- 60o) tower |
| 808 | Concrete for RCC type foundations including all material, shoring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for concrete (cost of supply of MS steel bar is not to be included) |
| 809 | M 20 (1:1.5:3) |
| 810 | M 10 (1:3:6) |
| 811 | Excavation of foundation pits including all earthwork, backfilling and levelling etc. |
| 812 | Super structure erection of various type of towers, tower part, tower extention (complete) with bolts & nuts and including all work above ground level excluding hoisting of insulators & fitting of danger plate, number plate, phase plate, circuit plate, anti climbing devices and bird guards, but including punching of bolts. |
| 813 | A type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 814 | B type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 815 | C type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 816 | Laying, Stringing, Tensioning, clamping, jointing etc. complete with Single ACSR Zebra conductor including hoisting of insulators and fitting of vibration dampers etc. for complete route of D/C Single Zebra. |
| 817 | Grounding work for Pipe type earthing including excavation and backfilling (Set of Two). |
| 818 | Tack welding on bolts and nuts on Ist section of towers |
| 819 | Fixing of tower accessories: |
| 820 | Danger plate |
| 821 | Number plate |
| 822 | Phase Plate (set of three) |
| 823 | Circuit Plate (set of two) |
| 824 | Anti-Climbing device |
| 825 | Birds Guards (set of six) |
| 826 | M.S. Steel bar for reinforcement |
| 827 | Installation of Avaition Items |
| 828 | Span markers |
| 829 | Obstruction lights (to be provided as per IS 5613) |
| 830 | 1 Medium + 2 low intensity |
| 831 | 1 Medium + 4 low intensity |
| 832 | Painting of Towers (As per IS:5613) |
| 833 | Erection of OPGW |
| 834 | Laying, Stringing Tensioning, clamping, jointing etc. complete with OPGW 48 Fibre - 220 kV and all requiered hardware such as Vibration damper, tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 220 kV lines |
| 835 | Reinforcing rod |
| 836 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 837 | Approach Cable 48 Fibre |
| 838 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 839 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 840 | Price Schedule-B -3 (Erection) for Construction of LILO of 132 kV Kichha-Rudrapur line at Proposed 400 kV Substation Khurpiya Farm |
| 841 | Part-1 |
| 842 | Survey |
| 843 | Detailed route Survey, Profiling, Alignment etc. including prepration of Tower schedule, Optimisation of tower locations etc and prepration of forest case (if any) complete in all respect |
| 844 | Check survey and final peg marking |
| 845 | Soil Investigation |
| 846 | Part-2 |
| 847 | Setting of Stubs, inlcuding all foundation work but excluding the cost of concreting and excavation |
| 848 | A type (0o- 2o ) tower |
| 849 | B type (2o- 30o ) tower |
| 850 | C type (30o- 60o) tower |
| 851 | Concrete for RCC type foundations including all material, shoring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for concrete (cost of supply of MS steel bar is not to be included) |
| 852 | M 20 (1:1.5:3) |
| 853 | M 10 (1:3:6) |
| 854 | Excavation of foundation pits including all earthwork, backfilling and levelling etc. |
| 855 | Super structure erection of various type of towers, tower part, tower extention (complete) with bolts & nuts and including all work above ground level excluding hoisting of insulators & fitting of danger plate, number plate, phase plate, circuit plate, anti climbing devices and bird guards, but including punching of bolts. |
| 856 | A type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 857 | B type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 858 | C type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 859 | Laying, Stringing Tensioning, clamping, jointing etc. complete with ACSR Panther conductor including hoisting of insulators and fitting of vibration dampers, jumpers at tower etc. for complete route for D/C Panther conductor. |
| 860 | Grounding work with Pipe type earthing (set of two nos. for each tower) and backfilling excluding cost of earthing material |
| 861 | Tack welding on bolts and nuts on Ist section of towers |
| 862 | Fixing of the following tower accessories |
| 863 | Bird Guard (set of six) |
| 864 | Danger plate |
| 865 | Number plate |
| 866 | Phase Plate (set of three) |
| 867 | Circuit Plate (set of two) |
| 868 | Anti-Climbing device |
| 869 | MS Steel bars for reinforcements |
| 870 | Installation of Avaition Items |
| 871 | Span markers |
| 872 | Obstruction lights (to be provided as per IS 5613) |
| 873 | 1 Medium + 2 low intensity |
| 874 | 1 Medium + 4 low intensity |
| 875 | Painting of Towers (to be provided as per IS 5613) |
| 876 | Erection of OPGW |
| 877 | Laying, Stringing Tensioning, clamping, jointing etc. complete with OPGW 48 Fibre - 132KV and all requiered hardware such as Vibration damper, tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 132 KV lines |
| 878 | Reinforcing rod |
| 879 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 880 | Approach Cable 48 Fibre |
| 881 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 882 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 883 | Price Schedule-B-4 (Erection) for LILO of 400 kV Bareilly-Kashipur Transmission line at proposed 400 kV Substation Khurpiya Farm |
| 884 | Part-1 |
| 885 | Survey |
| 886 | Detailed route Survey, Profiling, Alignment etc. including prepration of Tower schedule, Optimisation of tower locations etc and prepration of forest case (if any) complete in all respect |
| 887 | Check survey and final peg marking |
| 888 | Soil Investigation |
| 889 | Part-2 |
| 890 | Setting of Stubs, inlcuding all foundation work but excluding the cost of concreting and excavation |
| 891 | A type tower (0o- 02o) |
| 892 | B type tower (2o- 15o) |
| 893 | C type tower (15o- 30o) |
| 894 | D type tower (30o- 60o) |
| 895 | Concrete for foundations including all material, shoring and shuttering, forming, concreting and curing of water inlcuding cost of cement for M-20 (i.e. 1:1.5:3 mix) & M-10 (i.e. 1:3:6 mix) concrete (cost of supply of MS steel bar is not to be included) |
| 896 | Excavation of foundation pits including all earthwork, backfilling and levelling etc. |
| 897 | Normal Dry |
| 898 | Partially Submerged |
| 899 | Fully Submerged |
| 900 | Shallow |
| 901 | Super structure erection of various type of towers, tower part, tower extention (complete) with bolts & nuts and including all work above ground level excluding hoisting of insulators & fitting of danger plate, number plate, phase plate, circuit plate, anti climbing devices and bird guards, but including punching of bolts. |
| 902 | A type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 903 | B type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 904 | C type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 905 | D type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 906 | Laying, Stringing Tensioning, clamping, jointing etc. complete with Quad ACSR Moose conductor including hoisting of insulators and fittings of bundle spacer damper and rigid spacer etc. for complete route for D/C Quad Moose conductor. |
| 907 | Laying, Stringing Tensioning, clamping, jointing etc. complete with single earth wire 7/9 SWG including fixing of clamps and all accessories. |
| 908 | Grounding work with Pipe type earthing (set of two nos. for each tower) and backfilling excluding cost of earthing material |
| 909 | Tack welding on bolts and nuts on Ist section of towers |
| 910 | Fixing of tower accessories: |
| 911 | Danger Plate |
| 912 | Number Plate |
| 913 | Phase Plate (Set of three) |
| 914 | Circuit Plate Set of two) |
| 915 | Anti-Climbing Device( barbed wire type ) |
| 916 | Bird Guard (set of six) |
| 917 | M.S. Steel bar for reinforcement |
| 918 | Installation of Avaition Items |
| 919 | Span markers |
| 920 | Obstruction lights (to be provided as per IS 5613) |
| 921 | 1 Medium + 2 low intensity |
| 922 | 1 Medium + 4 low intensity |
| 923 | Painting of Towers (to be provided as per IS 5613) |
| 924 | Installation of Wind Measuring Equipment |
| 925 | Erection of OPGW |
| 926 | Laying, Stringing Tensioning, clamping, jointing etc. complete with OPGW 48 Fibre - 400 kV and all requiered hardware such as Vibration damper, tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 400 kV lines |
| 927 | Reinforcing rod |
| 928 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 929 | Approach Cable 48 Fibre |
| 930 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 931 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 932 | Price Schedule B-5 (Civil Works) 400/220/132/33 KV Sub station, Khurpia farm |
| 933 | Civil Works on Turn Key Basis |
| 934 | Buildings |
| 935 | Control room building (Plinth area to be measured). (It can be single or double storey building depending upon availability of space) including parking shed, rain water harvesting ponds, land scaping and park & plantation |
| 936 | DG Room and fire fighting pump house |
| 937 | Store shed ( Plinth area to be measured) |
| 938 | Security Room |
| 939 | Residences |
| 940 | Type V G/F (01 No. @ 178,50) |
| 941 | Type IV G/F (04 No. @ 125) |
| 942 | Type IV F/F (04 No. @ 125) |
| 943 | Type III G/F (06 No. @ 79) |
| 944 | Type III F/F (06 No.@ 79) |
| 945 | Type II G/F (08 No.@ 57,7) |
| 946 | Type II F/F (08 No. @ 57,7) |
| 947 | Construction of foundation of following structures including excavation and back filling of earth, CC/ RCC works including centering and shuttering, reinforcement, supply & fixing of bolts etc. complete. |
| 948 | 400 KV Tower |
| 949 | LM Tower |
| 950 | 400 KV Equipment |
| 951 | Surge arrester |
| 952 | Isolator |
| 953 | Circuit Breaker |
| 954 | 220 KV Tower |
| 955 | 220 KV Equipment |
| 956 | Circuit Breaker |
| 957 | Current Transformer (1 Ph.) with junction box |
| 958 | Lightening Arrestor |
| 959 | 1600A, 40 KA, isolator with one E/S |
| 960 | 1600A, 40 KA, isolator with two E/S |
| 961 | 1600A, 40 KA, isolator without E/S |
| 962 | 1600A, 40KA, Isolator without E/S (Tandem) |
| 963 | Bus post Insulator |
| 964 | Support Insulator for Wave trap |
| 965 | 132 KV Tower |
| 966 | 132 KV Equipments |
| 967 | Circuit Breaker |
| 968 | Lightening Arrester |
| 969 | 1250A, 40 KA, isolator with E/S |
| 970 | 1250A, 40 KA, isolator without E/S |
| 971 | 1250A, 40KA, Isolator without E/S (Tandem) |
| 972 | Bus post Insulator |
| 973 | 33 KV Tower |
| 974 | 33 KV Equipments |
| 975 | Circuit Breaker |
| 976 | Potential Transformer |
| 977 | Lighting Arrestor |
| 978 | Isolator Without E/S |
| 979 | Isolator With E/S |
| 980 | Bus post Insulator |
| 981 | Transformer |
| 982 | 500 MVA 400/220/33 kV, Three phase Transformer including first filling of oil, alongwith Fibre Optic Temperature Measurement System and all related equipments. |
| 983 | 125 MVAR 400 Bus Reactor including first filling of oil, alongwith Fibre Optic Temperature Measurement System and all related equipments. |
| 984 | 160 MVA 220/132 KV, Bus Reactor including first filling of oil, alongwith Fibre Optic Temperature Measurement System and all related equipments. |
| 985 | 80 MVA 132/33 KV Transformer |
| 986 | 800 KVA 33/0.4 KV Transformer |
| 987 | Fire Protection Wall between 500 MVA transformers |
| 988 | Fire Protection Wall between 160 MVA transformers |
| 989 | Fire Protection Wall between 80 MVA transformers |
| 990 | Construction of DG set plinth |
| 991 | RCC Cable trenches with trench covers ( all sections) including all type of crossing and all metallic work to support cables and trench covers. |
| 992 | 200 X 200mm size trench with minimum depth 200mm |
| 993 | 400 X 400mm size trench with minimum depth 400mm |
| 994 | 600 X 600mm size trench with minimum depth 600mm |
| 995 | 1000 X 1000mm size trench with minimum depth 1000mm |
| 996 | 2 x 1000x1000mm size trench with minimum depth 1000mm |
| 997 | Buried Cable Trenches |
| 998 | RCC Roads including all types of crossings |
| 999 | 1.8 metre wide |
| 1000 | 3.75 metre wide |
| 1001 | 5.00 metre wide |
| 1002 | Storm water drain including culverts, sumpwell, sump house and pumps etc. |
| 1003 | Security fencing 3.6 mtr high along with gates and security room |
| 1004 | Security fencing 3.6 mtr high along with gates and Toe Wall |
| 1005 | Switch yard turfing and antiweed treatment including leveling and dressing of area, PCC and gravels |
| 1006 | Construction of tube well with a discharge capacity of 500 lpm with KSB make submersible pumping set of 350 lpm discharge with L&T make panel board including construction of RCC Over Head Water Tank of 100 Kl capacity,15 Mtr staging, including pump house, connecting pipe lines, valves etc complete to ensure proper water supply in building and substations area with one spare pumping set and panel board. |
| 1007 | Land Development works |
| 1008 | Construction of 2.4 m high boundry wall having R.C.C. Column at 3 m C/C and brick panel upto 2.4 m from FGL and 600 mm barbed wire fencing with concertina wireabove these panels with 2 number RCC bands at FGL and top including required foundations and necessary RCC retaing wall for retain the earth filling upto FGL including construction of gate & security hut. |
| 1009 | Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 mabove ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 1010 | Earth filling in entire substation area including cost of earth. Earth to be obtained from outside the sub-station area including its cartage, ramming , watering, dressing in 20 cm thick layer etc. complete. |
| 1011 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 1012 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1013 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1014 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1015 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 1016 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1017 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars |
| 1018 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1019 | 12 mm cement plaster of mix : (1 cement: 4 coarse sand) |
| 1020 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sq over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 1021 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 1022 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required,1.00 mm thick with zinc coating not less than 275 gm/m² |
| 1023 | Lettering with black Japan paint of approved brand and manufacture |
| 1024 | Landscaping of Substation land ,Plantation and lawn development around substaion buildings including providing & installation of flower pots in Substaion buildings,providing & fixing of sign boards in switch yard & substations buildings and flex boards as directed & approved by E/I. |
| 1025 | Price Schedule B-6 (Type Test), Tower Detail:- 400 kV double circuit Narrow base towers suitable for plain terrain, Conductor Detail:- ACSR Quad Moose |
| 1026 | Fabrication and type testing of towers using ungalvanised (black) steel |
| 1027 | 400 kV double circuit \\"A\\" type tower suitable for (0 deg- 02 deg) with Body extension . |
| 1028 | 400 kV double circuit \\"B\\" type tower suitable for (2 deg- 15 deg) with Body extension . |
| 1029 | 400 kV double circuit \\"C\\" type tower suitable for (15 deg- 30 deg) with Body extension . |
| 1030 | 400 kV double circuit \\"D\\" type tower suitable for (30 deg- 60 deg)/Dead end with Body extension . Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 400 kV AIS Substation, Khurpiya Farm with its associated Lines\\" Contract No: PTCUL/E-Tender/C&P-II/SS-22/2026-27 |
| 1031 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) * Tender is of composite nature comprising of supply of goods and supply of services NOTE:- The bidder has to fill the GST AMOUNT on The green cells of AMOUNT COLOUM(4) ONLY. In case any discrepancy is observed in amount carried from BoQ1 & BoQ2 sheet as below, the value given in BoQ1 & BoQ2 sheet shall prevail. NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Particulars Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Pleas Enter ZERO Only AMOUNT VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 1032 | Total Price Schedule-A (Supply) from BoQ1 sheet WITHOUT GST |
| 1033 | Total Price Schedule-B ( Erection and Civil Work ) from BoQ2 sheet WITHOUT GST |
| 1034 | Add GST* Amount on (Total of Price Schedule-A + Total of Price Schedule-B above) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 29 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender