Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58384906

Tender For Drinking Water Supply Arrangement At Different Arws/Rws/Nrdwp /Ridf/Jjm Retrofitting Schemes Under Lefunga R.D Block/ Sh:Mtc. Of Leakages In The C.I, D.I & Pvc Pipeline, Removal Of Deposited Clouded Iron From The Existing C.I, D.I & Pvc Pi

Issued by Government Departments · tripura, Tripura
Tender Value
9.70 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
6 days left
EMD
19401
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Drinking Water Supply Arrangement At Different Arws/Rws/Nrdwp /Ridf/Jjm Retrofitting Schemes Under Lefunga R.D Block/ Sh:Mtc. Of Leakages In The C.I, D.I & Pvc Pipeline, Removal Of Deposited Clouded Iron From The Existing C.I, D.I & Pvc Pipeline In/C Other Allied Works During The Year 2026-27.

BOQ

Name of Work:- Drinking Water supply arrangement at different ARWS/RWS/NRDWP /RIDF/JJM Retrofitting schemes under Lefunga R.D Block/ SH:Mtc. of leakages in the C.I, D.I & PVC pipeline, removal of deposited clouded iron from the existing C.I, D.I & PVC pipeline in/c other allied works during the year 2026-27.
Sl. No. Item Description
1Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class - 3 ( working pressure 6.0 kg / cm2)
2i) 40 mm OD
3ii) 50 mm OD
4iii) 90 mm OD
5iv) 110 mm OD
6v) 140 mm OD
7Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
8i) 40 mm dia
9ii) 50 mm dia
1090 mm dia
11110 mm dia
12140 mm dia
13Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
1490 mm dia
15Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
16i) 40 x 40 mm dia
17ii) 50x50 mm dia
18iii) 90 x 90 mm dia
19iv) 110 x 110 mm dia
20v) 140 x 140 mm dia
21Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
2250x40 mm dia
23110 x 90 mm dia
24140 x 110 mm dia
25Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.A. External work.
26i) 15 mm dia. nominal bore
27ii) 25 mm dia. nominal bore
28Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge.
29i) 10 mm nominal bore
30Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
31i) 100 mm dia A.P.N 1.6
32ii) 125 mm dia A.P.N 1.6
33iii) 150 mm dia A.P.N 1.6
34Dismantling old C.I. / D.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre as per CPWD specification and direction of the Engineer - in -charge.
35i) 100 mm dia
36ii) 125mm dia
37iii) 150 mm dia
38Providing and fixing G.I. Nipple of medium class as perCPWD specification and direction of the Engineer - in - charge.
39i) 15 mm dia 150 mm long
40ii) 15 mm dia 250 mm long
41Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the Engineer - in - charge (cost of earth work and fittings will be
42i) 15 mm dia
43ii) 25 mm dia
44Providing and laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as per CPWD specification and direction of the Engineer - in - charge
45ii) 100 mm dia Ductile Iron Class K-7 pipes
46iv) 150 mm dia Ductile Iron Class K-7 pipes
47Excavating trenches of required width for pipes, cables etc. in/c excavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500mm (Slope-1 in 200) in/c getting out the excavated soil and backfilling of soil as required after laying of pipe line, in layers not exceeding 200mm in depth in/c consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter-2 of CPWD specification and direction of the Engineer-in-charge.
48A. For UPVC pipes in new work. a) In all kinds of soil. i) For pipes not exceeding 90mm dia.
49ii) For pipes exceeding 90mm dia but not exceeding 300mm dia.
50B. For G.I. / C.I. / D.I. pipes in new worka. In all kinds of soili) For pipes exceeding 90 mm dia but not exceeding 300 mm dia
51C. For UPVC pipes in old work. a) In all kinds of soil. i) For pipes not exceeding 90mm dia.
52ii) For pipes exceeding 90mm dia but not exceeding 300mm dia.
53D. For G.I. / C.I. / D.I. pipes in old worka. In all kinds of soili) For pipes exceeding 90 mm dia but not exceeding 300 mm dia
54Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
55i) 90 mm dia
56ii) 110 mm dia
57iii) 140 mm dia
58Providing and fixing GI Bend/elbow in the pipe line in/c testing of joints complete as per CPWD specification and direction of the Engineer-in-charge.
59i) 15mm dia.
60Providing and fixing GI socket as per CPWD specification and direction of the Engineer-in-charge.
61i) 15mm dia.
62ii) 25 mm dia
63Providing and fixing GI union as per CPWD specification and direction of the Engineer-in-charge.
64i) 15mm dia.
65ii) 25 mm dia
66Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
67i) 125 x 80 mm dia
68ii) 150x80 mm dia
69Charges for fixing and laying rigid UPVC pipes jointing with couplers, solvent cement including testing of joints complete ( excluding the cost of pipes, couplers, solvent cement which are to be issued from the department free of cost and specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class - 3 ( working pressure 6.0 kg / cm2)
70i) 90 mm OD
71ii) 110 mm OD
72iii) 140 mm OD
73Charges for laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as per CPWD specification and direction of the Engineer - in - charge.
74i) 150 mm dia
75Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.
76i) By manual means
77Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-incharge.
78i) 90 mm OD
79ii) 110 mm OD
80iii) 140 mm OD
81Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.
82i) 15 mm dia PVC/Plastic Bib Cock
83Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge.
84i) 90 mm dia
85ii) 110 mm dia
86iii) 140 mm dia
87Washing & removal of deposited iron sludge & any other foreign materials etc. from inside the existing water distribution pipeline foreign materials from inside the excavation trenches up to required width & depth cutting of PVC pipeline at a length of every 55.00 mtr. Interval jointing of pipe with PVC coupler and solvent cement in/c satisfactory testing of joints refilling trenches with available excavated earth etc. complete as per direction of the Engineer in charge [Rate in/c the cost of cement solvent PVC pipe for making PVC couplers, will be issued by the Department at free of cost]
88i) 90 mm dia
89ii) 110 mm dia
90iii) 140 mm dia
91Washing & removal of deposited iron sludge & any other foreign materials etc. from inside the existing water distribution pipeline (CI/DI) using UPVC pipe washing road fitted with Iron Brush in/c excavation trenches up to required width & depth cutting of CI/DI pipeline at a length of every 55.00 mtr. Interval or part there of & jointing of pipe & specials as required refilling trenches with available excavated earth etc.complete as per direction of the Engineer in charge. [The cost of CI specials lead joint rubber gasket joint will paid separately]
92i) 150 mm dia
93Charges for washing, cleaning & servicing of ferrule and connection pipe of street hydrant domestic water supply connection upto property line ( for side connection) in/c cost of earth excavation and dismantling the service line in/c ferrule and GI fitting etc. and reconnection the same after necessary washing, cleaning the same as per direction of the Engineer-in-charge. (GI fitting such as GI bend, GI union, GI socket & connection pipe in/c ferrule if required to be paid separately)
94Charges for washing, cleaning & servicing of ferrule and connection pipe of street hydrant domestic water supply connection upto property line ( for road crossing connection) in/c cost of earth excavation and dismantling the service line in/c ferrule and GI fitting etc. and reconnection the same after necessary washing, cleaning the same as per direction of the Engineer-in-charge. (GI fitting such as GI bend, GI union, GI socket & connection pipe in/c ferrule if required to be paid separately)
95Providing & fitting, fixing two part GI/MS tyton joint collar with rubber gasket & MS flange fitted with MS flats & square bar at both end in/c nuts & bolts, rubber washer & painting with anticorrosive black bitumastic paint etc. complete as per direction of the Engineer in charge.i)150 mm dia.
96Providing and laying D.I. specials of class K - 12 suitable for push - on jointing as per IS : 9523 as per CPWD specification and direction of the Engineer - in - charge.
97i) Upto 300 mm dia. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58384906
AUTHORITY Government Departments
TENDER VALUE 9.70 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Drinking Water Supply Arrangement At Different Arws/Rws/Nrdwp /Ridf/Jjm Retrofitting Schemes Under Lefunga R.D Block/ Sh:Mtc. Of Leakages In The C.I, D.I & Pvc Pipeline, Removal Of Deposited Clouded Iron From The Existing C.I, D.I & Pvc Pipeline In/C Other Allied Works During The Year 2026-27.
Basic Detail
Tender No 69/DNIeT/EE/DWS/AGT-II/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 04 Nov 2026
Submission Date 12 Nov 2026
Open Date 12 Nov 2026
Finance
Tender Value 9.70 Lakhs
Tender Fee 1000
EMD 19401
Exemption Not Available
Document List
BOQ_80282.xls
DNIeT69.pdf
f397d818-cc83-4691-bd98-ce1d2ede63c6.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_80282.xls

pdf

DNIeT69.pdf

html

f397d818-cc83-4691-bd98-ce1d2ede63c6.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender