Tender For Repair/Maint Of External Water Supply Services Incl Repair/Maint/Replacement Of Unsv Pipeline Valve Various Water Pump Set, Cleaning Of Sump And Other Connected E/M Works At Kwc Timarpur Under Ge(North) Delhi Cantt-10
Tender Overview
Project Description
Tender for Repair/Maint Of External Water Supply Services Incl Repair/Maint/Replacement Of Unsv Pipeline Valve Various Water Pump Set, Cleaning Of Sump And Other Connected E/M Works At Kwc Timarpur Under Ge(North) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out in loose/soft soil for laying of cable/pipes complete all as specified & directed |
| 2 | Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed |
| 3 | Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed |
| 4 | M&L for boring/ making hole under road by drilling machine or hand drill without damaging of road for laying U/G cable for size 40/50/80 mm bore of GI pipe complete all as specified & directed |
| 5 | M&L for servicing of DG set capacity 10 KVA, 3 phase, 415 Volt, 50 Hz including carrying out maintenance and check alongwith following repairs including replacement of worn out parts :- (a) Replacement of lubricating oil (b) Replacement of Engine Oil filter cartridge with New one.(c) Cleaning /Descaling /Callibration of Deisel fuel tank and writing date of cleaning complete (d) Renew fuel filter cartridge with New one.(e) Check tightness of all nuts and bolts. (f) Check adjustment of V belt for driving engine water pump and alternator.(g) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction. (h) Servicing of radiator (j) Cleaning of air cleaner filter and renew after period of hrs run as specified by manufacture.(k) Checking complete exhaust system including examining puncture in the mufler and redoing the complete insulation for adequate noise and pollution reduction complete (m) Testing of DG set after repair & servicing for smooth running of DG Set as per Manufacturers Instructions as directed . Note:- Any minor parts as required at site shall be supplied by the contractor. Cost for the same shall be deemed to be included in the unit rate quoted. |
| 6 | S&F copper stranded cable PVC insulated three core PVC insulated for motor to starter of following sizes for various capacities of motors. |
| 7 | (a) 6 Sq mm |
| 8 | (b) 10 Sq mm |
| 9 | M&L for Disconnection electrical and water connection of the centrifugal pump and motor 10 HP with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt fixing the require new parts (parts such as shaft, impellor, coupling & bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation, testing & commisioning |
| 10 | Supply only shaft suitable for centrifugal pumps for 10 HP |
| 11 | Supply only GM impellor suitable for centrifugal pumps for 10 HP |
| 12 | Supply only MS coupling suitable for centrifugal pumps for 10 HP |
| 13 | Supply only bearing suitable for centrifugal pumps for 10 HP |
| 14 | S&F in replacement of connection pieces suitable for 10 HP pump |
| 15 | S&F in replacement of CI upper & lower housing for 10 HP |
| 16 | S&F in replacement of CI motor base for10 HP |
| 17 | S&F in replacement of revolving disc for capacity10 HP |
| 18 | S&F in replacement of rotor guard for 10 HP |
| 19 | S&F in replacement of SS rotor sleeves for 10 HP |
| 20 | S&F in replacement of sealing ring for 10 HP |
| 21 | M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding complete with all insulation material such as colton top varnish etc of centrifugal pump set motor 10 HP complete |
| 22 | M&L for Disconnection electrical and water connection of the induction motor with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt including two coat of synthetic enameled paint over a coat of red oxide primer fixing the require new parts (parts such as shaft impeller and coupling bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete for the following size/ capacity of motors Note :- Rate includes transportation of motor from the place of installation for repairing and re-installing the same on existing foundation, testing & commisioning :- |
| 23 | (a) 5 HP |
| 24 | (b) 1 HP |
| 25 | Supply only shaft suitable for induction motor pumps for the following sizes :- |
| 26 | (a) 5 HP |
| 27 | (b) 1 HP |
| 28 | Supply only bearing suitable for induction motor pumps for the following sizes :- |
| 29 | (a) 5 HP |
| 30 | (b) 1 HP |
| 31 | M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding with all insulation material such as colton top varnish etc of centrifugal pump set motor 5 HPcomplete all as specified and directed for the following sizes |
| 32 | S&F in replacement of connection pieces suitable for 5 HP pump |
| 33 | S&F in replacement of CI upper & lower housing for 5 HP |
| 34 | S&F in replacement of CI motor base for 5 HP |
| 35 | S&F in replacement of rotor guard for 5 HP |
| 36 | S&F in replacement of SS rotar sleeves for 5 HP |
| 37 | S&F in replacement of sealing ring dor 5 HP |
| 38 | S&F fully automatic star delta starter appx full load with necessary relay and air break contactor complete with incoming and outgoing connection complete including taking down existing complete all as directed of size/rating MN 16F of make L&T at load of 9-15 Amps. |
| 39 | Supply, laying, jointing & testing of GI Pipe, medium grade, including all fittings in old/new position, laid in trenches/ wall including taking down the old/unsv pipe line complete all as specified & directed of following sizes :- |
| 40 | (a) 80 mm dia |
| 41 | (b) 50 mm dia |
| 42 | (c) 40 mm dia |
| 43 | (d) 25 mm dia |
| 44 | (e) 20 mm dia |
| 45 | (f) 15 mm dia(Note : Excavation and earth work shall be measured and paid separately under respective items of schedule) |
| 46 | S&F in repair gun metal, globe or gate valve, screwed down high pressure with iron wheel head, screwed both ends complete for the following sizes of pipes :- |
| 47 | (a) 50 mm dia |
| 48 | (b) 40 mm dia |
| 49 | (c ) 25 mm dia |
| 50 | (d) 20 mm dia |
| 51 | (e) 15 mm dia |
| 52 | Supply, laying, jointing and testing of Cast Iron Pipe with spigot & socketed end, centrifugally cast, Class LA push on joint laid in trenches in old/ new route as required at site including taking down the old/unsv pipe line complete all as specified & directed of following sizes:- |
| 53 | (a) 100 mm dia |
| 54 | (b) 150 mm dia [Note for item No.6 :- Contractor will make his own all necessary arrangement for execution / laying of pipe line work incl liasion with civil / local authority at civil area / road, as & where applicable/ required] |
| 55 | M&L for run lead joint in spigot and socketted pipe of size 80mm including spun yarn complete all as specified and directed for following sizes of pipes :- |
| 56 | (a) 100mm dia |
| 57 | (b) 150mm dia |
| 58 | M& L for cast iron bends (any type, radius and angle) tapers any type (straight, bend, increasing decreasing or double socket etc) tee piees, single branch, 'Y' junction, double branch cross (all sockets or socket & spigot) collars, caps and plugs for spigot socketed pipes upto 150 mm bore complete. |
| 59 | M&L for cast iron sluice valve of pressure class PN-1.6 type flanged and drilled at both ends, conforming to ISI mark and having gun metal spindle and rings including wheel for operating all as specified including two numbers flanged socket and jointing materials such as bolts, nuts, washers, rubbers/ fibre board gasket including taking down old unserviceable valve from pipe line of both ends complete of following sizes:- |
| 60 | (a) 100 mm dia |
| 61 | (b) 80 mm dia |
| 62 | Supply and fixing of non return valve of size 80mm dia, class PN-1.6, cast iron body, single door, both ends flanged type including all necessary fittings ie rubber gasket, nut & bolts, washers complete all as specified and directed. |
| 63 | M&L for bailing out the water from the semi underground/UG sump capacity upto 10,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed (Note:- Rates quoted deemed to be inclusive of all T&Ps and safety equipments required at site) |
| 64 | M&L for bailing out the water from the semi underground/UG sump capacity 20,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed (Note:- Rates quoted deemed to be inclusive of all T&Ps and safety equipments required at site) |
| 65 | M&L for PVC ball valves high pressure of PTMT with epoxy coated Aluminium rod & highd ensity plastic ball complete assembly screwed for iron pipe and fixed and taking out UNSV complete for the following sizes :- |
| 66 | (a) 15 mm |
| 67 | (b) 20 mm |
| 68 | (c) 25 mm |
| 69 | S&F MS chequred plate of 6mm thick including provision of lifting handle for each plate on existing trenches/ manhole covers for semi under ground sumps according to site condition complete all as directed |
| 70 | M&L for construction of brick masonary valve pit chamber of size 1050mm x 1050mm x 1050mm (internal dimension) including necessary excavation and earthwork, PCCin foundation, brick work,12 mm thick rendering in cement mortar 1:4 on internal surface of valve pit and mild steel sheet cover 3mm thick and mild steel angle iorn frame size 40 x 40 x 5 mm around of valve pit, locking arrangement with pad lock of size 50 mm brass, 6 leavers and key (Make : Godrej) complete including two coat of synthetic enamel over a coat red oxide primer on steel surface with preparation of surface and including dismantling of existing valve pit complete all as specified & directed. |
| 71 | All as per the description of srl item No 42 above item but size 900mm x 900mm x 900mm |
| 72 | M&L for spray painting of complete water Pumpset of any type up to 10 HP capacity with two coats of synthetic enameled paint of specified colour after preparation of surface complete |
| 73 | M&L for painting of water supply pipes net works consisting of valves of any type and size at various pump houses inlcuding duly scrapping thoroughly the existing corroded paint / dirt/ dust / rust and preparing the surface and applying two coats of synthetic enamel paint over a coat of red oxide primer as per the colour code and marking the water flow directions on pipe lines as directed. |
| 74 | (a) 80 mm bore |
| 75 | (b) 100 mm bore |
| 76 | Supply only bleaching powder stable of 33% chlorine all as specified (Make : DCM/RMCO/Rayalaseema or equivalent) |
| 77 | M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 25 X 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete .Note-Testing of eathing after completion. the permissible resistence is obtained without any extra cost. |
| 78 | Supply only gland packing with wire rope 1/4 \\" 1/2\\" |
| 79 | Supply only rubber insertion sheet 4mm thick |
| 80 | S&F 3 pole power contactor ML-1.5 for starter incl taking down old one complete (Make : L&T or equivalent as approved) |
| 81 | S&F 3 pole power contactor MNX 9 having 1 NO of rating 9-25 Amps complete. (Make : L&T or equivalent as approved) |
| 82 | S&F single phase preventor for 3 phase motors fixed for star delta starters complete. (Make : L&T or equivalent as approved) |
| 83 | S&F Electronic Timers type ST 100, 415 V for 3-30 secs complete. (Make : L&T or equivalent as approved) |
| 84 | S&F Volt meter (0-500 volt) square/round digital type incl taking down old one complete |
| 85 | S&F Amp meter (0-100) square/round digital type incl taking down old one complete |
| 86 | M&L for preparation of old painted steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enameled paint of approved shade complete |
| 87 | S&F MCCB 4 Pole, 415 volt, 16 -36 KA of following capacity on existing panel including removing old one complete (Make : Legrand/ L&T/ Havells/ Schneider) :- |
| 88 | (a) 250 amps, 36 KA, adjustible type |
| 89 | (a) 200 amps, 36 KA, adjustible type |
| 90 | (b) 160 amps, 36 KA, adjustible type |
| 91 | (c ) 100 Amps, 16 KA, fixed type |
| 92 | (d) 63 Amps, 16 KA, fixed type |
| 93 | Chemical, Boilogical, Potability Testing of water sample at Govt recognised/approved institute/Lab for potability and chemical analysis complete all as specified & directed. |
| 94 | Supply only Calcium Hypo Chlorite 65% to 70% granules as specified (Make : Aquafit or equivalent as approved) |
| 95 | S&F in replacement of water pressure gauge with black steel case, copper alloy wetted parts, snap-in- acrylic window with white plastic dial and plastic pointer having 0-21 kg/cm2 pressure range complete all as specified & directed (Make-Cummins/Kirloskar/WIKA) |
| 96 | Supply only Chlorination testing kit incl solution, glass vessels tubular type etc complete all as specified and directed |
| 97 | M&L for total hardness test (5-1000 mg/L) kit with coloured sample complete with all testing fitment and OT solution in rexine finish box. (Make- Aquafit/ Aquasol) |
| 98 | M&L for PCC 1:4:8 type D-2, using stone aggregate 40mm graded, with and including demolishing the existing dameged foundation, complete all as directed. |
| 99 | S&F in repair PVC tank of 100 ltr capcity and antiscalant chlorine dosing pump of SS body 10 LPH capacity,manually operated,having user friendly knob for adjusting dosing frequency, strainer & controller for chemical flow,double ball NRV ,CE certified,IP-65 incl inlet & outlet flexible pvc pipes all as specified & directed |
| 100 | M&L in replacement of Ladder for OHT/UG sump with sqaure bar,angle iron,channel,Flat Iron and etc welding.drilling.cutting with one primer coat.one under coat and one finishing coat of paint. Complete all as specified and as directed |
| 101 | Supply & Fixing in replacement of monoblock type MI-C series centrifugal pump having discharge capacity 20 LPS at 15 meter head complete with induction motor upto 5 HP, 3 phase 415 volts 50Hz mounted on common base frame complete all as specified and directed . |
| 102 | M&L for replacement of PVC 100mm Heavy duty suction hose pipe for sewage well/sump of any size complete all as per directed |
| 103 | Supply and fixing 50 mm dia DJB approved/empanelled Woltman type bulk water meter, flanged, Class-B, conforming to IS:2373/ISO 4064, suitable for commercial/main water supply, complete with flanges, nuts, bolts, gaskets, testing/calibration certificate and all accessories, complete in all respects. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender