Tender for Repair/Maintenance Of Low Tension Electric System And Allied Work At Md Accn, Ctw, 262 Cedu, Fcbrnp At Cme Under Ge (Cme) Khadki (8759/E8)
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying /removing of cable all as specified and directed by Engineer-in-Charge as in |
| 2 | Soft/loose soil |
| 3 | Hard/dense soil |
| 4 | Soft/disintegrated rock. |
| 5 | Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified and directed by Engineer-in-Charge. |
| 6 | Removing excavated material (soil) not.exceeding 50m and deposited where directed at a level not.exceeding 1.5 m above the starting point complete as specified and directed by Engineer-in-Charge. |
| 7 | Supply & Laying in replacement of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 76 mm polyethylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed by Engineer-in-Charge.Note:- Necessary earthwork, excavation shall be measured and paid separately. |
| 8 | Supply & Laying in replacement of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polyethylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed by Engineer-in-Charge.Note:- Necessary earthwork, excavation shall be measured and paid separately. |
| 9 | Supply & Laying in replacement of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polyethylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed by Engineer-in-Charge.Note:- Necessary earthwork, excavation shall be measured and paid separately. |
| 10 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge.Note:- Necessary gate pass mentioning vehicle no shall be submitted along with RAR for payment duly signed by Engineer-in-Charge. |
| 11 | M & L and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, etc complete all as specified and directed in and including taking up/ dismantling of old deteriorated RCC/steel pole safely complete all as specified and directed by Engineer-in-Charge. |
| 12 | M & L for Plain Cement Cable 1:3:6 type C1 using 20 mm graded stone aggregate for coping of poles/plinth blocks of LT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 13 | M & L for Plain Cement Cable 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles including formwork complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply , laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area 4 core 16 Sqmm in and including taking out of old unserviceable cable complete all as specified and directed by Engineer-in-Charge.Note:- Necessary earthwork, excavation shall be measured and paid separately. |
| 15 | All as per item 11 above but of the size 4 core 25 Sqmm |
| 16 | All as per item 11 above but of the size 3.5 core 35 Sqmm |
| 17 | All as per item 11 above but of the size 3.5 core 50 Sqmm |
| 18 | All as per item 11 above but of the size 3.5 core 70 Sqmm |
| 19 | All as per item 11 above but of the size 3.5 core 95 Sqmm |
| 20 | All as per item 11 above but of the size 3.5 core 120 Sqmm |
| 21 | All as per item 11 above but of the size 3.5 core 150 Sqmm |
| 22 | All as per item 11 above but of the size 3.5 core 240 Sqmm |
| 23 | M&L for fault detection in damaged UG cables using cable fault detector/locator, vehicle mounted to accuracy of 2m for various locations inside CME for UG cables of any size & any type upto 22kv grade including excavation & earthwork in any type of strata of size 4x2x0.6m to visually inspect/repair the damaged cable when and where directed by Engineer-in-Charge.Note:- Necessary gate pass mentioning vehicle no shall be submitted along with RAR for payment duly signed by Engineer-in-Charge. |
| 24 | Supply and fix straight through cable joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 25-50 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and fix straight through cable joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fix straight through cable joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material and labour in replacement of old broken ACSR with new aluminium conductor steel reinforced streching without kinks / bends and binding with insulators on street poles complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material & labour in replacement of old cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material and labour in replacement of pin type, porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 Volts grade complete all as specified and directed by Engineer-in-Charge. |
| 30 | Material and labour in replacement shackle type porcelain vitreous white, brown or green insulator incl GI mild steel strip, washer, insulator bolts, washers and nut for working pressure 1100 volts section of strips 31 x 3 mm,max dia 90mm, height 75 mm,dia of bolt 12mm upto 9 metre long complete all as specified and directed by Engineer-in-Charge. |
| 31 | S & F in replacement of stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 20 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 type C2 complete all as specified and directed by Engineer-in-Charge. |
| 32 | M & L for loose filling with aggregates of gauge 40mm in switch yard and surrounding to LT panels complete all as specified and directed by Engineer-in-Charge. |
| 33 | Re-stringing of over head line ACSR conductor on existing lines by unbinding at each pin/shackle/Disc type insulator and re-fixing the same after stretching conductor, removing excess sag, maintaining proper distance between conductors as specified, tightening of stay wire, binding of PVC line separators two per span, all as specified and as directed for the following types of configurations:- |
| 34 | Set of four |
| 35 | Set of two |
| 36 | Guard wire |
| 37 | M&L for cutting of tree branches n.exc 10 cm in girth along LT OH lines at distance not less than 3 m distance from both sides of conductors complete incl clearing of bushes any type not less than dia 10 cms and all other growings around respective poles of area not less than 4 sqm all when and where as complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L for clearing of grass shrubs and other growing by uprooting in switchyards and electric installations upto 10 cms in girth at various locations as complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supplying and laying GI tubing light grade 100 mm dia incl all accessories for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works including taking down old tubing complete all as specified and directed by Engineer-in-Charge. |
| 40 | All as per item no 35 above but size 50 mm bore |
| 41 | M&L for in repairs MCCB 4 pole, 400 Amps, 415 V, breaking capacity 50 kA thermal magnetic release adjustable type complete all as specified and directed by Engineer-in-Charge. |
| 42 | M&L for in repairs MCCB 4 pole, 250 Amps, 415 V, breaking capacity 36 kA thermal magnetic release adjustable type complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L for in repairs MCCB 4 pole, 160 Amps, 415 V, breaking capacity 25 kA thermal magnetic release adjustable type complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for in repairs MCCB 4 pole, 125 Amps, 415 V, 25 kA thermal magnetic release adjustable type complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L for in repairs MCCB 4 pole, 100 Amps, 415 V, breaking capacity 25 kA thermal magnetic release adjustable type complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for in repairs MCCB 4 pole, 63 Amps, 415 V, breaking capacity 25 kA thermal magnetic release adjustable type complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm incl dismantling old thimbles of any type complete all as specified and directed by Engineer-in-Charge. |
| 48 | Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm incl dismantling old thimbles of any type complete all as specified and directed by Engineer-in-Charge. |
| 49 | Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm incl dismantling old thimbles of any type complete all as specified and directed by Engineer-in-Charge. |
| 50 | Material and labour for shifting heavy items / earth work / cleaning areas / clearing site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete, all as specified and as directed complete all as specified and directed by Engineer-in-Charge. |
| 51 | M&L for Chemical spray (DC> 2-26 having container 415ml/300g for precision blended multipurpose product preventing corrosion penetrates, lubricates, displaces and seals out moisture release rusted mechanism cleanse etc complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 52 | M&L for Chemical spray (DC> 2-26 having container 415ml/300g for precision blended multipurpose product preventing corrosion penetrates, lubricates, displaces and seals out moisture release rusted mechanism cleanse etc complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender