Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #58383625

Tender For maintenance of Pump Sets And electrical installation At Various Places In Dwarka.Sh: Annual Maintenance Of Path/Park Lighting Upto 10 Mtr. High Poles By Supplying, Replacement And Installation Of Light Fittings, Cable, Mccbs, Mcbs, Timer,

Issued by Local Bodies · Delhi, Delhi
Tender Value
23.95 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
0 days left
EMD
47914
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of Pump Sets And electrical installation At Various Places In Dwarka.Sh: Annual Maintenance Of Path/Park Lighting Upto 10 Mtr. High Poles By Supplying, Replacement And Installation Of Light Fittings, Cable, Mccbs, Mcbs, Timer, Contactor, And Other Allied Accessories For Greens/Parks & Store Cum Site Office Under Horticulture Division- Dwarka.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-Nov-2026

BOQ

Name of Work:- M/o pump sets and E.I. at various places in Dwarka.SH: Annual maintenance of Path/Park lighting upto 10 mtr. high poles by supplying, replacement and installation of light fittings, cable, MCCBs, MCBs, Timer, contactor, and other allied accessories for greens/parks & store cum site office under Hort. Division- Dwarka.
Sl. No. Item Description
1Day to day maintenance of Path/Park lighting poles upto 10 mtr. height as per inventory, terms and conditions attached.
2Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 45 watt
3Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 100 watt
4Supply & replacement of pole connector box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade S1 of outside dimensions 280 mm(H) x 170 mm(W)x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65 mm dia GI pole with the following provisions/accessories mounting in box complete as reqd.(i)2 nos. clamps made out of 19mm x 3 mm GI strip of suitable length for mounting box on the pole.(ii) Water tight front cover with 2 nos. stainless steel hinges & 1 no. screw for tightening.(iii)4 way, 220 V, 30 A, dough moulded connector (SMC with stainless steel inserts)(iv) 16 amp. Moulded SMC rewireable kit-kat---1 no.(v) Suitable size hole at suitable location on rear wall for cable & wire entry.(vi) Earthing bolt M6 x 20 mm
5Supplying of following sizes of XLPE insulated PVC sheathed Al. cond. Armoured power cable of 1.1 KV grade including connection, testing etc. as required. a) 2C x 16 sq. mm
6b) 4C x 25 sq. mm.
7Supplying & drawing following size FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.a) 3 x 1.5 sq. mm
8b) 3 x 2.5 sq. mm
9Taking out of 1 no. Faulty LT power Cable, already laid in ground by way of digging and relaying of the same after removing of the cable fault i/c refilling and redressing of the trench ets as reqd.
10Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a)63 mm dia. (OD-63 mm & ID-51 mm nominal)
11Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.a)Upto 35 sq. mm
12Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.a) 2 x 16 sq.mm
13b) 4 x 25 sq.mm
14c) 4x35 sq. mm
15d) 4x50 sq. mm
16Supplying and replacement of following items, connection, testing etc. in the existing LT panel board as reqd.a) 32A AC-3, 3 Pole power contactor
17b) Analogue Time Switch
18c) 100A MCCB 30 KA 4 Pole
19e) 6 amp to 32 amp SP MCB, 10 KA, C-Curve
20f) DPMCB 32 amp, 10 KA, C-Curve
21g) 125A MCCB 4 pole 36 KA,C-Curve
22h) 250A MCCB 4 pole 36 KA,C-Curve
23Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required.
24Dismantling of existing damaged panel foundation & re-casting the same including brick, mortar, cement plaster etc. complete as required.
25Repairing of existing feeder pillar with 2 mm thick CRCA sheet including welding providing required no. of hinge, painting etc. complete as reqd.
26Repairing of existing wiremesh protection frame including replacement of 6 SWG M.S. Wiremesh size (75mm x 25mm) rectangle nominal size i/c replacement / repair of locking arrangement, nut-bolts etc. complete as reqd.
27Hire charges of faulty location machine to locate the faulty in existing underground cable etc. complete as reqd.
28Painting of existing wiremesh protection frame/ feeder pillar of different size with 2 nos. of enamel paint i/c coating primer etc. complete as reqd.
29Supplying & installation of anti-climbing device for existing 6/8/6 mtr. high pole etc. complete as reqd.
30Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(a) Group C
31Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing thepoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a) Group C
32Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required. a) 2 X 1.5 sq.mm +1 X 1.5 sq.mm earth wire
33Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 6 way , Double door (DSR - 2.3.1)
34(b) 8 way , Double door (DSR - 2.3.2)
35LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following bodymaterial and construction as per IS : 10322 with driver (Replaceable) as per the requirement withDriver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)a) 18- 22 Watt
36Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required.a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
37Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR -1.32)
38Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. (DSR-1.5)
39Supplying, Fabrication, replacement and Installation of wire mesh protection frame for existing feeder pillar made out of 8 SWG M.S wire mesh size (75mmX25mm rectangle nominal) of following size with M.S angle iron base frame 35mm X 35mm X 5mm angle iron and with M.S strip support of size 35mm X 5mm in cross and 0.5mtr long legs support of same angle (as per drawing attached), i/c door in front portion, supplying and fitting of go down lock i/c locking arrangement, painting and grouting of angle iron frame with lugs in CC 1:3:6 foundation etc. as approved by Engineer incharge etc. complete as regd.(a) 2 mtr (H) X 1.5 mtr (W) X 1.0 mtr (D)
40Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR - 5.2)
41Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR - 5.15)
42Painting and numbering (2 coating) of existing G.I. pole of upto 4/5/6 mtr. height including painting of base plate & mounting arrangement etc. complete as reqd.
43Excavation around existing square foundation and dismantling existing pole for cable laying upto 3 mtr. from base plate, refilling the trench after jointing the cable, re-installation of pole on foundation, finishing/ plastering of exsting foundation above ground level i/c shifting of connector box upto 2.5 mtr. height and replacement of Kit-kat, connector, clamp etc. and painting of pole, refilling the gap between foundation & base plate etc. complete as reqd. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58383625
AUTHORITY Local Bodies
TENDER VALUE 23.95 Lakhs
LAST DATE 14-11-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Pump Sets And electrical installation At Various Places In Dwarka.Sh: Annual Maintenance Of Path/Park Lighting Upto 10 Mtr. High Poles By Supplying, Replacement And Installation Of Light Fittings, Cable, Mccbs, Mcbs, Timer, Contactor, And Other Allied Accessories For Greens/Parks & Store Cum Site Office Under Horticulture Division- Dwarka.
Basic Detail
Tender No 61/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 09 Nov 2026
Submission Date 14 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 23.95 Lakhs
Tender Fee Ref. Documents
EMD 47914
Exemption Available
Document List
BOQ_980574.xls
d73a1d3a-5122-41ed-803c-56a3c8a93e38.html
NIT61.pdf
TenderNoticeNIT61.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_980574.xls

html

d73a1d3a-5122-41ed-803c-56a3c8a93e38.html

pdf

NIT61.pdf

pdf

TenderNoticeNIT61.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender