Educational and Research Institute Boards / Undertakings / PSU Closing in 5 days TDR #58383341

Tender For Supply Installation Testing and Commissioning of Cassette Air Conditioner Machine Of Capacity 2Tr, & Split Type 1.5Tr,100% Copper Both Condenser & Compressor With Remote Controller To Be Installed At N.R Sen Seminar Room,Rajabazar Science

Issued by Boards / Undertakings / PSU · Kolkata, West Bengal
Tender Value
2.53 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
5 days left
EMD
5000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Cassette Air Conditioner Machine Of Capacity 2Tr, & Split Type 1.5Tr,100% Copper Both Condenser & Compressor With Remote Controller To Be Installed At N.R Sen Seminar Room,Rajabazar Science College, C.U. , Supply Installation Testing and Commissioning of 3 Star Rating Cassetteair Cinditioner Machine 2Tr,Inverter Typrwith R32 Gas Including Remote Controller Suitable For Operation On 230V +/- 10% Volt,50Hz Single Phase Ac Supply With Air Cooled Evaporator With Copper Coil,Fan And Fan Motor.Air Cooled Copper Condenser, Hermetically Sealed Copper Compressor,Propeller Fan Control Panels Incl Wirings,Necy Power Cable Connection Make: Bluestar,Hitachi,Voltas Or Equivalent . , Providing And Fixing Copper Pipe With Nitrile Rubber Insulation Not Less Than 0.6Mm Thickness Suitable Size Required For Suction And Return Refrigerant With Suitable Insulation For Above Ac S Complete In All Aspects As Required In Excess Of 3Mtrs / Machine , Supply And Laying 20Mm Dia Isi Marked Flexiblepvc Pipe Along With Accessories On Surface Of The Wall To Drain Out Condensate Water From Indoor Unit 5 To10mm Thickness 3 Dia.3 Thickness 5-10 Mm , S And F Factory Fabricated Ms Structure For Placing The 1.5Tr Capacity Split Outdoor Unit On Existing Building. By Ms Fastner , S Andf 4C Flexib;E Copper Cable Of 4Sq.Mm From Indoor To Outdoor Unit Incl.Connection,Commissioing Testing Etc As Reqd , Supply Installation Testing and Commissioning of 3 Star Rating Split Air Cinditioner Machine With R32 Gas Including Remote Controller Of Following Capacity Suitable For Operation On 230V +/- 10% Volt,50Hz Single Phase Ac Supply With Air Cooled Evaporator With Copper Coil,Fan And Fan Motor.Air Cooled Copper Condenser, Hermetically Sealed Copper Compressor,Propeller Fan Control Panels Incl Wirings,Necy Power Cable Connections From Unit To Power Socket,Refrigerant Pipe Of Appropriate Size Between Indoor And Outdoor Unit Upto 3 Mtr Length. Both Suction & Delivery Incl. Gas Charging,Complete As Required Make Inverter Hitachi, Daikin,Blue Star,Voltas Or Equivalent

BOQ

Name of Work:- SITC OF CASSETTE AIR CONDITIONER MACHINE OF CAPACITY 2TR, & SPLIT TYPE 1.5TR,100% COPPER BOTH CONDENSER & COMPRESSOR WITH REMOTE CONTROLLER TO BE INSTALLED AT N.R SEN SEMINAR ROOM,RAJABAZAR SCIENCE COLLEGE, C.U.
Sl. No. Item Description
1SITC of 3 star rating cassetteair cinditioner machine 2TR,inverter typrwith R32 gas including remote controller suitable for operation on 230V +/- 10% volt,50Hz single phase AC supply with air cooled evaporator with copper coil,fan and fan motor.air cooled copper condenser, hermetically sealed copper compressor,propeller fan control panels incl wirings,necy power cable connection Make: Bluestar,Hitachi,Voltas or equivalent .
2Providing and fixing copper pipe with nitrile rubber insulation not less than 0.6mm thickness suitable size required for suction and return refrigerant with suitable insulation for above AC s complete in all aspects as required in excess of 3mtrs / machine
3Supply and laying 20mm dia ISI marked flexiblepvc pipe along with accessories on surface of the wall to drain out condensate water from indoor unit 5 to10mm thickness 3'' Dia.3\\" thickness 5-10 mm
4S and F factory fabricated MS structure for placing the 1.5TR capacity split outdoor unit on existing building. By MS fastner
5S andF 4C flexib;e copper cable of 4sq.mm from indoor to outdoor unit incl.connection,commissioing testing etc as reqd
6SITC of 3 star rating split air cinditioner machine with R32 gas including remote controller of following capacity suitable for operation on 230V +/- 10% volt,50Hz single phase AC supply with air cooled evaporator with copper coil,fan and fan motor.air cooled copper condenser, hermetically sealed copper compressor,propeller fan control panels incl wirings,necy power cable connections from unit to power socket,refrigerant pipe of appropriate size between indoor and outdoor unit upto 3 mtr length. both suction & delivery incl. gas charging,complete as required make inverter hitachi, Daikin,blue star,voltas or equivalent Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58383341
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.53 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name University Of Calcutta
Work Description Tender for Supply Installation Testing and Commissioning of Cassette Air Conditioner Machine Of Capacity 2Tr, & Split Type 1.5Tr,100% Copper Both Condenser & Compressor With Remote Controller To Be Installed At N.R Sen Seminar Room,Rajabazar Science College, C.U. , Supply Installation Testing and Commissioning of 3 Star Rating Cassetteair Cinditioner Machine 2Tr,Inverter Typrwith R32 Gas Including Remote Controller Suitable For Operation On 230V +/- 10% Volt,50Hz Single Phase Ac Supply With Air Cooled Evaporator With Copper Coil,Fan And Fan Motor.Air Cooled Copper Condenser, Hermetically Sealed Copper Compressor,Propeller Fan Control Panels Incl Wirings,Necy Power Cable Connection Make: Bluestar,Hitachi,Voltas Or Equivalent . , Providing And Fixing Copper Pipe With Nitrile Rubber Insulation Not Less Than 0.6Mm Thickness Suitable Size Required For Suction And Return Refrigerant With Suitable Insulation For Above Ac S Complete In All Aspects As Required In Excess Of 3Mtrs / Machine , Supply And Laying 20Mm Dia Isi Marked Flexiblepvc Pipe Along With Accessories On Surface Of The Wall To Drain Out Condensate Water From Indoor Unit 5 To10mm Thickness 3 Dia.3 Thickness 5-10 Mm , S And F Factory Fabricated Ms Structure For Placing The 1.5Tr Capacity Split Outdoor Unit On Existing Building. By Ms Fastner , S Andf 4C Flexib;E Copper Cable Of 4Sq.Mm From Indoor To Outdoor Unit Incl.Connection,Commissioing Testing Etc As Reqd , Supply Installation Testing and Commissioning of 3 Star Rating Split Air Cinditioner Machine With R32 Gas Including Remote Controller Of Following Capacity Suitable For Operation On 230V +/- 10% Volt,50Hz Single Phase Ac Supply With Air Cooled Evaporator With Copper Coil,Fan And Fan Motor.Air Cooled Copper Condenser, Hermetically Sealed Copper Compressor,Propeller Fan Control Panels Incl Wirings,Necy Power Cable Connections From Unit To Power Socket,Refrigerant Pipe Of Appropriate Size Between Indoor And Outdoor Unit Upto 3 Mtr Length. Both Suction & Delivery Incl. Gas Charging,Complete As Required Make Inverter Hitachi, Daikin,Blue Star,Voltas Or Equivalent
Basic Detail
Tender No R/49/tender/26-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 04 Nov 2026
Submission Date 17 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 2.53 Lakhs
Tender Fee Ref. Documents
EMD 5000
Exemption Not Available
Document List
9589da0b-ed7c-4fd0-81d8-6fe9800922ba.html
BOQ_2567314.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

9589da0b-ed7c-4fd0-81d8-6fe9800922ba.html

xls

BOQ_2567314.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender