Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58381607

Tender For Providing Of Deficient Barrack Store At 25 Wg Under Ge (Af) Gurgaon

Issued by Statutory Bodies & Commissions/Committees · Gurgaon, Haryana
Tender Value
43.72 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
16 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Providing Of Deficient Barrack Store At 25 Wg Under Ge (Af) Gurgaon

BOQ

Name of Work:- Provn of Deficient Barrack Store at 25 WG under GE (AF) Gurgaon
Sl. No. Item Description
1Excavation in trenches n exc 1.5 m wide and n exc 1.5 m deep for foundation and getting out in soft/loose soil all as directed and specified.
2Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25 cm soft/ loose soil all as directed and specified.
3Removing excavated materials n exc 50 m and depositing where directed at a level n exc 1.50 mtr above the starting point all as directed.
4M&L PCC 1:4:8 type D2 (40mm graded aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
5M&L for RCC 1:2:4 type B1 (using 20 mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed. Note:- Form work and reinforcement shall be measured and paid separately.
6M&L for RCC 1:2:4 type B1 (using 20 mm graded aggregate) in Columns, pillars, piers, postsand struts complete all as specified and directed. Note:- Form work and reinforcement shall be measured and paid separately.
7M&L for RCC 1:2:4 type B1 (using 20 mm graded aggregate) in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and directed. Note:- Form work and reinforcement shall be measured and paid separately.
8M&L for RCC 1:2:4 type B1 (using 20 mm graded aggregate) as in Chajja and like sturcture complete all as specified and directed. Note:- Form work and reinforcement shall be measured and paid separately.
9Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces complete all as specified and directed.
10Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with sqaure/rectangular shape with rough finished surfaces complete all as specified and directed.
11Use & Waste Formwork to sides of roof beam and lintel cantilivier shelves with square rectantular rough finished surfaces of concrete.
12Use & Waste Formwork to chullah hoods, chajjas, troughs and similar items including edges
13Formwork to edges of concrete flats(rough finished surface of concrete), breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening)
14S/F TMT bars 10 mm dia and over cut to length, bent to shape as required incl cranking bending hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia for Footing, column, plinth beam, liltel, beam and slab, complete all as specified and as directed.
15TMT Bars 8mm dia, cut to length, bent to shape as required including cranking, bending, hooking ends and binding with MS Wire (annealed) not less than 0.9 mm dia, as in stirrups for column, plinth beam, beam and lilten spaces and binders complete all as specified and as directed.
16M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified.
17M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified.
18M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
19M&L for carryout the anti termite treatment of soil treating the top surface of filled earth at the rate of 5 litres of emulsion per Sqm of surface(floor)
20M&L for carryout the anti termite treatment under plinth protection at the rate of 5 litres of emulsion per Sqm. Of surface(floor)
21M&L for carryout the anti treatment alongwith perifery of building at the rate of 2.25L of emulsion per litre of the perimeter of wall
22M&L Hardcore of broken stones gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
23M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
24M&L for 75 mm thick PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregates as in subbase floor finished the surface even and rough complete all as specified.
25Machine cut kota stone slab flooring,20-25mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 20mm screed layer in cement mortar 1:4, rubbing, grinding and polishing, complete all as specified.
26Machine cut Kota stone slab flooring 20-25 mm thick over cement screed base as in riser, skirting, dado etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick backing coat in CM 1:4 complete all as specified.
27M&L for Vitrified Ceramic Tiles 10mm thick (Square/Rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in CM 1:4. complete all as specified and directed
28Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointes in neat cenment slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for CM (1:4) for laying floor finishes.
29M & L Coloured Glazed ceramic tiles in vertical surfaces 300x600mmx7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:3) complete all as specified and directed
30M&L 15 mm thick rendering in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces, rendering finished even and smooth (without using extra cement) complete all as specified and directed.
31M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 on external wall finished even and smooth mixed with integral water proofing compound in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.
32Supply Liquid water proofing compound
33M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished fair and even complete all as specified and directed.
34M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges and providing 6 mm thick joints through the thickness of plinth protection duly filled with mastic filling of one part of hot bitumen 85/25 grade and three parts of fine sand (all by weight) complete all as specified and directed.
35M&L for two coats of oil bound distemper over a coat of priming coat on newly prepared wall surfaces incl 1mm applying plaster of paris putty over plastered surface, all as specified and directed..
36M&L for preparation on newly plastered / previously untreated surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) complete all as specified and directed.
37S&F Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, hasp, Safety lever locks and staple and one shop coat of primer; erected in position as indicated,complete with gear operated type with bevel gear box and crank handle as specified and as directed.
38S&F structural steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as directed and specified.
39S&F steel structural work as in post, purlins, rafters, truss etc. complete conforming to Fe 410W (Gde E-250) all as specified and as directed
40M&L MS Plates Fe-410-W(Gde-E-250) quality-B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
41M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
42S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
43S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
44M & L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified.
45S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 \\"D\\" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items)
46S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
47S&F sheet glass 4 mm thick ordinary quality and glazing with oil putty, wooden beads or rubber seal complete all as specified.
48Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed.
49M&L for Plain Cement Concrete Type 1:3:6 type C-2 (using 40 mm graded granite stone aggregate) in foundations, filling mass concrete and posts concrete complete all as specified and directed.
50S&F for Mild Steel posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe 290 Gde E - 165 complete all as specified and directed.
51S&F for galvanised iron chain link fencing with 3.8 mm to 4mm dia wire mesh size 75 X 75 (as per sample approved by GE) complete all as specified and directed.
52S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with andprovision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).
53S&F MS screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other, or screwed both ends, each screwed end to be fitting with washer and one hexagonal or square nut n.exc. 5cm long and dia of shank 5 to 10 mm etc.
54M & L 10 mm dia MS round bar for fixing of chain link fencing with post.
55M&L for preparing new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description n. exc 10 cm width or girth.
56Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loose soil.
57Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface.
58M&L for 75 mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in subbase of flooring complete all as specified.
59Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
60Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
61M&L for PCC 1:2:4 type B0 using 12.5mm graded aggregate, as in coping, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating incl necessary formwork complete all as specified and directed.
62M&L for 100mm thick PCC 1:2:4 (nominal mix) type B-1 (using 20mm graded crushed stone aggregates) as in floor, path and hard standing finished even and smooth without using extra cement complete all as specified and directed.
63M&L for point wiring in steel enamelled steel conduit on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with including modular type metal rectangular box of suitable size and plate and frame of modular type including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-
64One light / fan point controlled by one way switch
65One 5 Amp socket outlet on independent board.
66One 5 Amp socket outlet on same board.
67All as per above item No-1 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
68S & F in of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including stove enamelled steel conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
69S&F of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
70S&F socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
71S&F switch 6 amps modular type one one way complete all as directed.
72S&F switch 16 amps modular type one one way complete all as directed.
73S&F socket outlet 6A-2/3 pin combined 2 module modular type complete all as specified and directed.
74Supply and fixing LED type flood light 35 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
75S&F sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.
76S&F MCB SP 5 to 40 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
77S&F MCB DP 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
78Supply & fixing ceiling fans complete with copper winding,remote, blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge.
79S&F of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. Please Enable Macros to View BoQ information
80S&F of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58381607
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.72 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Deficient Barrack Store At 25 Wg Under Ge (Af) Gurgaon
Basic Detail
Tender No GE/GUR-/NIT-117/2026-27
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 04 Nov 2026
Submission Date 25 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 43.72 Lakhs
Tender Fee 500
EMD 88000
Exemption Not Available
Document List
90194803-2863-4b16-b55d-1037fc98dcd5.html
BOQ_894322.xls
TenderDocumentsNIT117.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

90194803-2863-4b16-b55d-1037fc98dcd5.html

xls

BOQ_894322.xls

pdf

TenderDocumentsNIT117.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender