Bids Are invited for M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty For 1100 Volts Grade Cross Sectional Area 25 Sqmm 3.5 Core Including Cable Gland And Lugs - M And L For Cable In Trenches Or Passing Through Pipe Xlp
Tender Overview
Project Description
Bids Are invited for M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty For 1100 Volts Grade Cross Sectional Area 25 Sqmm 3.5 Core Including Cable Gland And Lugs - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 25 Sqmm 3.5 Core Including Cable Gland And Lugs , M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Lt Cable With For 1100 Volts Grade Cross Sectional Area 70 Sqmm 3.5 Core Including Cable Gland - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 70 Sqmm 3.5 Core Including Cable Gland , M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Lt Cable With For 1100 Volts Grade Cross Sectional Area 95 Sqmm 3.5 Core - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 95 Sqmm 3.5 Core , M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or For 1100 Volts Grade Cross Sectional Area 240 Sqmm 3.5 Core - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 240 Sqmm 3.5 Core , Excavating In Trenches Not Exc 1.50 Mtr Wide And Not Exc 1.50 Mtr In Depth Getting Out In Soft Or Loose Soil , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 250Mm In Soft Or Loose Soil , Removing Excavated Materials Not Exc 50.00 Mtr And Depositing Where Directed At A Level Not Exc 1.50 Mtr Above The Starting Point In Soil , M And L Sand Cushioning In Trenches For Protection Of Ug Cables Of 230Mm Spread Thickness And Consolidated Upto 180Mm Thickness Complete , M And L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable , S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Or Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts , S And F Galvanised Iron Pipe 50Mm Bore Light Grade For Protection Of Ug Cable Laid In Floors Crossing Fixing To Pole With Mild Steel Clamps, Nuts, Bolts , S And F Hdpe Dwc Of Diameter 40 Mm Including Disconnection And Connection Of Cable Near Panel Or Oh For Pipe Fixing Including Joints , S And F Hdpe Dwc Of Diameter 90 Mm Including Disconnection And Connection Of Cable Near Panel Or Oh For Pipe Fixing Including Joints , M And L For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia Under Road Foot Path Not Exc 10.00 Mtr In A Single Length , M And L For Earthing Complete With Ms Galvanized Plate Of Size 60Cm 60Cm 6Mm As 2.25 Mtrs Deep Below Not Less Than 1.5 Mtrs Below Normal Ground Level - M And L For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm As Earth Electrode Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level , Supply And Fixing Sheet Moulding Compound Junction Box Ip 66 Weather Proof For Outdoor Installation Of Size 205 255 112 With Knockouts For Cable 2 Nos 4 10 To 25 Sqmm - Supply And Fixing Sheet Moulding Compound Junction Box Ip 66 Weather Proof For Outdoor Installation Of Size 205 X 255 X 112 With Knockouts For Cable Entry Suitable For Terminating 2 Nos 4 X 10 To 25 Sqmm Ug Cable Including Ms Clamp With Nut And Bolt And Cable Glandes 2 Nos And Four Way Terminal , Supply And Fixing Submain Wiring With Five Runs Of 6 Sqmm Single Core Multi Stranded Frls Unsheathed Pvc Copper Conductor Cable 1100 Volts As Per Colour Code Drawn In Casing Capping - Supply And Fixing Submain Wiring With Five Runs Of 6 Sqmm Single Core Multi Stranded Frls Unsheathed Pvc Copper Conductor Cable 1100 Volts As Per Colour Code Drawn In Casing Capping Including All Accessories As Required And Connecting To Existing Main Switch Board And Testing On Completion Including Dismantling Old Unserviceable Submain Wiring Complete.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty for 1100 volts grade cross sectional area 25 sqmm 3.5 core including cable gland and lugs | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 3.5 core including cable gland and lugs |
| 2 | M and L for cable in trenches or passing through pipe XLPE insulated LT cable with for 1100 volts grade cross sectional area 70 sqmm 3.5 core including cable gland | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 70 sqmm 3.5 core including cable gland |
| 3 | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty LT cable with for 1100 volts grade cross sectional area 95 sqmm 3.5 core | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 95 sqmm 3.5 core |
| 4 | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or for 1100 volts grade cross sectional area 240 sqmm 3.5 core | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 240 sqmm 3.5 core |
| 5 | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil |
| 6 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil |
| 7 | Removing excavated Materials not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the Starting Point in Soil | Removing excavated Materials not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the Starting Point in Soil |
| 8 | M and L Sand Cushioning in Trenches for protection of UG Cables of 230mm Spread thickness and consolidated upto 180mm thickness complete | M and L Sand Cushioning in Trenches for protection of UG Cables of 230mm Spread thickness and consolidated upto 180mm thickness complete |
| 9 | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable |
| 10 | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts |
| 11 | S and F Galvanised Iron Pipe 50mm Bore Light Grade for protection of UG Cable laid in Floors Crossing fixing to Pole with Mild Steel Clamps, Nuts, Bolts | S and F Galvanised Iron Pipe 50mm Bore Light Grade for protection of UG Cable laid in Floors Crossing fixing to Pole with Mild Steel Clamps, Nuts, Bolts |
| 12 | S and F HDPE DWC of Diameter 40 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints | S and F HDPE DWC of Diameter 40 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints |
| 13 | S and F HDPE DWC of Diameter 90 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints | S and F HDPE DWC of Diameter 90 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints |
| 14 | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc 10.00 mtr in a Single Length | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc 10.00 mtr in a Single Length |
| 15 | M and L for earthing complete with MS galvanized plate of size 60cm 60cm 6mm as 2.25 mtrs deep below not less than 1.5 mtrs below normal ground level | M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level |
| 16 | Supply and Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 255 112 with knockouts for cable 2 Nos 4 10 to 25 Sqmm | Supply and Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 x 255 x 112 with knockouts for cable entry suitable for terminating 2 Nos 4 x 10 to 25 Sqmm UG cable including MS clamp with nut and bolt and cable glandes 2 Nos and four way terminal |
| 17 | Supply and Fixing Submain wiring with five runs of 6 sqmm single core multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts as per colour code drawn in casing capping | Supply and Fixing Submain wiring with five runs of 6 sqmm single core multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts as per colour code drawn in casing capping including all accessories as required and connecting to Existing main switch board and testing on completion including dismantling old unserviceable submain wiring complete. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender