Bids Are invited for M And L For Cable In Trenches Or Passing Through Pipe Xlpe Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt 1100 10 Sqmm 4 Core - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 10 Sqmm 4 Core , All As Per Item Ser No 1 Above But Of Size 16 Sqmm 4 Core , All As Per Item Ser No 1 Above But Of Size 25 Sqmm 3.5 Core , All As Per Item Ser No 1 Above But Of Size 50 Sqmm 3.5 Core , All As Per Item Ser No 1 Above But Of Size 70 Sqmm 3.5 Core , All As Per Item Ser No 1 Above But Of Size 95 Sqmm 3.5 Core , All As Per Item Ser No 1 Above But Of Size 120 Sqmm 3.5 Core , Excavating In Trenches Not Exc 1.50 Mtr Wide And Not Exc 1.50 Mtr In Depth Getting Out In Soft Or Loose Soil , Returning Filling In Including Spreading Levelling Watering And Not Exc 250Mm In Soft Or Loose Soil Complete - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 250Mm In Soft Or Loose Soil Complete , Removing Excavated Materials Not Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc 1.50 Mtr - Removing Excavated Materials Not Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc 1.50 Mtr Above The Starting Point In Soil , M And L Sand Cushioning Dry In Trenches For Protection Of 230Mm Spread Thickness And Consolidated Upto 180Mm Thickness Complete - M And L Sand Cushioning Dry In Trenches For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 230Mm Spread Thickness And Consolidated Upto 180Mm Thickness Complete , M And L For Fly Ash Bricks Locally Available In Trenches For Protection Of Ug Cable - M And L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable , S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Etc - S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc , S And F Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc , S And F Hdpe Dwc Of Diameter 40 Mm With Coupler Including Disconnection And Connection Of Cable Near Panel Or Oh For Pipe Fixing Including Joints Complete , S And F Hdpe Dwc Of Diameter 63 Mm With Including Disconnection And Connection Of Cable Near Panel Or Oh For Pipe Fixing Including Joints , M And L For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia Under Road Or Foot Path Not Exc 10 Mtr In A Single Length Complete , M And L For Earthing Complete With Ms Galvanized Plate Of Size 60Cm60cm6mm As Earth Electrode Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtrs Not Less Than 1.5 Mtrs - M And L For Earthing Complete With Ms Galvanized Plate Of Size 60Cm60cm6mm As Earth Electrode Buried 2.25 Mtrs Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level Connected To Galvanised Iron Strip 25 4Mm
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | M and L for cable in trenches or passing through pipe XLPE heavy duty galvanised steel strip or wire armoured electric LT 1100 10 sqmm 4 core | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core |
| 2 | All as per Item Ser No 1 above but of size 16 Sqmm 4 Core | All as per Item Ser No 1 above but of size 16 Sqmm 4 Core |
| 3 | All as per Item Ser No 1 above but of size 25 Sqmm 3.5 Core | All as per Item Ser No 1 above but of size 25 Sqmm 3.5 Core |
| 4 | All as per Item Ser No 1 above but of size 50 Sqmm 3.5 Core | All as per Item Ser No 1 above but of size 50 Sqmm 3.5 Core |
| 5 | All as per Item Ser No 1 above but of size 70 Sqmm 3.5 Core | All as per Item Ser No 1 above but of size 70 Sqmm 3.5 Core |
| 6 | All as per Item Ser No 1 above but of size 95 Sqmm 3.5 Core | All as per Item Ser No 1 above but of size 95 Sqmm 3.5 Core |
| 7 | All as per Item Ser No 1 above but of size 120 Sqmm 3.5 Core | All as per Item Ser No 1 above but of size 120 Sqmm 3.5 Core |
| 8 | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil |
| 9 | Returning Filling in including Spreading Levelling Watering and not exc 250mm in Soft or Loose Soil complete | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil complete |
| 10 | Removing excavated Materials not exc. 50 mtr and depositing where directed at a level not exc 1.50 mtr | Removing excavated Materials not exc. 50 mtr and depositing where directed at a level not exc 1.50 mtr above the Starting Point in Soil |
| 11 | M and L Sand Cushioning dry in Trenches for protection of 230mm Spread thickness and consolidated upto 180mm thickness complete | M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness and consolidated upto 180mm thickness complete |
| 12 | M and L for fly ash bricks locally available in trenches for protection of UG cable | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable |
| 13 | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps etc | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc |
| 14 | S and F Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc | S and F Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc |
| 15 | S and F HDPE DWC of Diameter 40 mm with coupler including disconnection and connection of cable near panel or OH for pipe fixing including joints complete | S and F HDPE DWC of Diameter 40 mm with coupler including disconnection and connection of cable near panel or OH for pipe fixing including joints complete |
| 16 | S and F HDPE DWC of Diameter 63 mm with including disconnection and connection of cable near panel or OH for pipe fixing including joints | S and F HDPE DWC of Diameter 63 mm with including disconnection and connection of cable near panel or OH for pipe fixing including joints |
| 17 | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road or Foot Path not exc 10 mtr in a Single Length complete | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road or Foot Path not exc 10 mtr in a Single Length complete |
| 18 | M and L for earthing complete with MS galvanized plate of size 60cm60cm6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs not less than 1.5 mtrs | M and L for earthing complete with MS galvanized plate of size 60cm60cm6mm as earth electrode buried 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 25 4mm |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender