New and Renewable Energy Government Departments Closing in 8 days TDR #58376019

Bids Are invited for Annual Maintenance Service-Air Conditioner - Charges Towards The Full-Service Maintenance For The Designated Air Conditioning Units To Restore Peak Cooling Performance, Improve Indoor Air Quality, And Optimize Energy Efficiency.

Issued by Government Departments · Gurgaon, Haryana
Tender Value
22.01 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
8 days left
EMD
44028
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Available
Quantity
150

Project Description

Bids Are invited for Annual Maintenance Service-Air Conditioner - Charges Towards The Full-Service Maintenance For The Designated Air Conditioning Units To Restore Peak Cooling Performance, Improve Indoor Air Quality, And Optimize Energy Efficiency. This Service Includes A Complete Physical Deep Clean With Pressure Washer (Indoor & Outdoor Units) And A Multi-Point System Diagnostic Test. , Supply And Installation Of Compressor For 05 Tr Capacity Of Ductable Ac System. , Supply And Installation Of Outdoor Unit Fan Motor For 05 Tr Capacity Of Ductable Air Conditioners System As Required , Supply And Installation Of Accumulator / Filter Drier For 05 Tr Capacity Of Ductable Air Conditioners System As Required , Charging Of Refrigeration Gas Of 5 Tr Ductable Air-Conditioner As Per Site Requirement , Supply And Installation Of Contactor Of Ductable Air Conditioners System As Required , Supply, Installation, Testing, And Commissioning Of A High-Efficiency Evaporator /Condenser Coil Designed For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Performance Blower Fan Assembly Designed For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Precision Thermostatic Expansion Valve (Txv) For Precise Refrigerant Flow Control For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Control Board / Pcb For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply And Installation, Of Refrigerant Piping For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Other Safety Controls Like High/Low-Pressure Switches, Sensor And Overload Protectors Etc For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Condensing Coil Valve For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply And Installation Of Compressor For 1.5 To 02 Tr Capacity Of Window/ Split/ Cassette Air Conditioners Unit , Supply And Installation Of Outdoor Unit Fan Motor For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply And Installation Of Pcb Board/ Kit For All Type (Inverter & Non Inverter) Air Conditioner For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Testing And Charging Of Refrigeration Gas (900G To 1400G) For All Type (Inverter & Non Inverter) Air Conditioner For 1.5 To 02 Tr Air Conditioners Unit As Per Site Requirement , Providing Labor, Equipment, And Materials For The High-Pressure Nitrogen (N2) Leak Testing, Pressure Holding Test For 24 Hr, Brazing Repair (If Can Be Repair) Of The Ac Coil. , Supply, Installation, Testing, And Commissioning Of A High-Efficiency Evaporator /Condenser Coil Designed For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Performance Blower Fan Including Louvers/Vanes For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Other Safety Controls Like Switches, Sensor (Air And Coil) Etc For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply And Installation Of Motor For 1.5 Tr Capacity Of Window Air Conditioner Units As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Efficiency Evaporator /Condenser Coil Designed For 1.5 Capacity Of Window Air Conditioners Unit As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Performance Blower Fan Including Louvers/Vanes For 1.5 Tr Capacity Of Window Air Conditioner Units As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Control Board / Pcb For 1.5 Tr Capacity Of Window Air Conditioner Units As Per Site Requirement , Supply And Installation Of Copper Pipe 1/4 Dia Including Nuts, Unions, Brazing, Insulation And Compression Accessories , Supply And Installation Of Copper Pipe 5/8 Dia Including Nuts, Unions, Brazing And Compression Accessories , Supply And Installation Of Copper Pipe 3/8 Dia Including Nuts, Unions, Brazing And Compression Accessories , Supply And Installation Of Copper Pipe 1/2 Dia Including Nuts, Unions, Brazing And Compression Accessories , Supply And Installation Of Condensing Valve For All Type (Window And Split) Air Conditioner Up To 05 Tr, As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Reliability Digital Voltage Stabilizer (4 Kva, 5 Kva) Tailored For Air Conditioner Protection As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Condenser 3 To 10 Mfd, 230 Volts For Indoor Unit As Per Site Requirment , Supply, Installation, Testing, And Commissioning Of Condenser 50±2, ±4, ±6 Mfd, 230 Volts For Outdoor Unit As Per Site Requirement , Supply And Installation Of 12 Mm To 20 Mm Drain Water Pipe (Pvc/ Flexible)As Per Site Requirement Including All Fittings , Supply And Installation Of Outdoor Fan Blade As Per Site Requirement Including All Fittings , Supplying And Fixing Wall Mounting Stand For Installation Of Outdoor And Indoor Unit Of Split Type Air Conditioners As Per Site Requirement , Supply Of Remotes For Air Conditioners As Per Site Requirement , Supply, Fabrication, Routing, Installation, Testing, And Commissioning Of Galvanized Sheet Steel (Gss) (18 To 24 Gauge As Required) Ducting. The Rate Includes Raw Material, Factory Or Site Fabrication, Transverse Jointing Systems (Flanges, Cleats, Gaskets), Neoprene Rubber Gaskets, Sealant, And Anchor Fasteners. It Includes Supportive Structural Hangers, Threaded Rods, Ms Angles, And Anti-Vibration Rubber Pads. , Supply And Installation Of Pre-Formed Tubular Closed Cell Nitrile Rubber Insulation Sleeves Over Copper Refrigerant Piping (Suction And Liquid Lines Separately)/Air Duct. All Joints Between Sleeves Must Be Sealed Using Specialized Adhesive And Wrapped With 50-100 Mm Wide Black Nitrile Foam Tape To Ensure A Continuous Vapour Barrier And Prevent Condensation , Supply, Installation, Testing, And Commissioning Of A Plug-In Control / Auxiliary Relay For The Air Handling Unit (Ahu) Control Circuit As Per The Site Requirement . The Relay Must Feature A Transparent Dust-Proof Polycarbonate Cover, An Integrated Led Status Indicator, And A Manual Test Tab. The Item Must Include A Matching Din-Rail Mounted Base Socket With Screw Terminals, Installed Neatly Inside The Ahu Starter/Control Panel. , Supply, Installation, Testing, And Commissioning Of A Double Inlet Double Width (Didw) Centrifugal Blower / Fan For An Air Handling Unit (Ahu) With A Capacity Up To 6000 Cfm. The Blower Housing And Wheel Must Be Fabricated From Heavy-Gauge Galvanized Steel Sheet (Gi) With A Corrosion-Resistant Finish. The Assembly Must Feature A Statically And Dynamically Balanced Forward Or Backward-Curved Impeller Shaft Mounted On Heavy-Duty, Self-Aligning Pillow Block Bearings With Lubrication Fittings. The Unit Includes An Adjustable Motor Mounting Base, A Matched Set Of V-Belts, Cast Iron Pulleys (Taper-Lock Type), And A Heavy-Duty Gi Wire Mesh Belt Guard. The Entire Fan Assembly Must Be Isolated From The Ahu Casing Using Fire-Retardant Flexible Canvas Connections And Mounted On Spring Vibration Isolators. , Supply And Installation Of Standard Classical V-Belt (A / B / C / D Section) For Replacement Or New Installation In Ahu Belt-Drive Systems As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A Deep-Pleat Hepa (High-Efficiency Particulate Air) Filter For Terminal Or In-Line Mounting Within The Air Handling Unit (Ahu) Filter Section (Size Of 1.5X1.5 Ft To 3X3 ) As Per Site Requirement , Providing Labour, Machinery, And Materials For The Complete Dismantling, Comprehensive Rewinding, And Overhauling Of A Three-Phase Squirrel Cage Induction Motor Or Monoblock/Submersible Pump Set Up To 3 Hp Motor Capacity. The Scope Of Work Includes Dismantling, Stripping The Burnt Windings, Thorough Cleaning And Baking Of The Stator Core, And Rewinding Using Premium Super-Enameled Copper Wire (Class F/H Insulation). The Job Includes The Complete Replacement Of Inter-Phase Insulation Sheets, Slot Wedges, And Heavy-Duty Varnishing Followed By Controlled Oven Baking. The Price Is All-Inclusive Of Replacing High-Grade Anti-Friction Ball/Roller Bearings, Mechanical Carbon-Ceramic Lip Seals / Water Seals, Dynamic Balancing Of The Rotor/Impeller Assembly On A Balancing Machine, And Replacement Of Elastomeric Flexible Elements In The Shaft Coupler. The Unit Must Be Reassembled With New Hardware, Gaskets, And Terminal Block Connectors, Followed By Testing For Insulation Resistance (Megger Test), No-Load Current, And Full-Load Performance Tracking. , Providing Labour, Machinery, And Materials For The Complete Dismantling, Comprehensive Rewinding, And Overhauling Of A Three-Phase Squirrel Cage Induction Motor Or Monoblock/Submersible Pump Set Up To 3.5 To 5 Hp Motor Capacity. The Scope Of Work Includes Stripping The Burnt Windings, Thorough Cleaning And Baking Of The Stator Core, And Rewinding Using Premium Super-Enameled Copper Wire (Class F/H Insulation). The Job Includes The Complete Replacement Of Inter-Phase Insulation Sheets, Slot Wedges, And Heavy-Duty Varnishing Followed By Controlled Oven Baking. The Price Is All-Inclusive Of Replacing High-Grade Anti-Friction Ball/Roller Bearings, Mechanical Carbon-Ceramic Lip Seals / Water Seals, Dynamic Balancing Of The Rotor/Impeller Assembly On A Balancing Machine, And Replacement Of Elastomeric Flexible Elements In The Shaft Coupler. The Unit Must Be Reassembled With New Hardware, Gaskets, And Terminal Block Connectors, Followed By Testing For Insulation Resistance (Megger Test), No-Load Current, And Full-Load Performance Tracking. , Providing Labor, Machinery, And Materials For The Complete Dismantling, Comprehensive Rewinding, And Overhauling Of A Three-Phase Squirrel Cage Induction Motor Or Monoblock/Submersible Pump Set 5.5 To 7.5 Hp Motor Capacity. The Scope Of Work Includes Stripping The Burnt Windings, Thorough Cleaning And Baking Of The Stator Core, And Rewinding Using Premium Super-Enameled Copper Wire (Class F/H Insulation). The Job Includes The Complete Replacement Of Inter-Phase Insulation Sheets, Slot Wedges, And Heavy-Duty Varnishing Followed By Controlled Oven Baking. The Price Is All-Inclusive Of Replacing High-Grade Anti-Friction Ball/Roller Bearings, Mechanical Carbon-Ceramic Lip Seals / Water Seals, Dynamic Balancing Of The Rotor/Impeller Assembly On A Balancing Machine, And Replacement Of Elastomeric Flexible Elements In The Shaft Coupler. The Unit Must Be Reassembled With New Hardware, Gaskets, And Terminal Block Connectors, Followed By Testing For Insulation Resistance (Megger Test), No-Load Current, And Full-Load Performance Tracking. , Comprehensive Overhauling, Servicing, And Testing Of 5 Hp To 7.5 Hp Capacity Water Pumps (Including Centrifugal, Submersible, And Monoblock Types) To Restore Optimal Operating Efficiency. The Scope Of Work Include The Replacement Of Bearing, Seal, Coupler, Oil And Greasing, Alignment & Balancing As Requirement , Supply, Installation, Testing, And Commissioning Of An Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan Designed For Direct Installation Into An 8-Inch (200 Mm) Ventilation Duct Including Aal Nassesory Fittings Like Mcb, Switch Wire Etc. The Fan Housing Must Feature A Heavy-Duty, Aerodynamic Double-Walled Casing Lined Internally With High-Density, Sound-Absorbing Acoustic Foam Or Fiberglass Insulation To Break Sound Waves And Ensure Ultra-Quiet Operation. The Impeller Must Be A High-Shroud, Mixed-Flow Design Optimized To Deliver Maximum Cfm Against High Static Pressure. The Central Motor-Impeller Block Must Feature A Quick-Release Pull-Out Design, Allowing Complete Maintenance Without Dismantling The Connected Ductwork. The Motor Must Be An External Rotor Type With Integrated Thermal Overload Protection, Class F Insulation, And Permanently Lubricated Sealed Ball Bearings. The Installation Includes Heavy-Duty Anti-Vibration Ceiling Hangers, Rubber Gaskets On The Duct Collars For Airtight Sealing, And A Matching Speed-Controller Switch. , Supply, Installation, Testing, And Commissioning Of An Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan Designed For Direct Installation Into An 6-Inch (200 Mm) Ventilation Duct Including Aal Nassesory Fittings Like Mcb, Switch Wire Etc. The Fan Housing Must Feature A Heavy-Duty, Aerodynamic Double-Walled Casing Lined Internally With High-Density, Sound-Absorbing Acoustic Foam Or Fiberglass Insulation To Break Sound Waves And Ensure Ultra-Quiet Operation. The Impeller Must Be A High-Shroud, Mixed-Flow Design Optimized To Deliver Maximum Cfm Against High Static Pressure. The Central Motor-Impeller Block Must Feature A Quick-Release Pull-Out Design, Allowing Complete Maintenance Without Dismantling The Connected Ductwork. The Motor Must Be An External Rotor Type With Integrated Thermal Overload Protection, Class F Insulation, And Permanently Lubricated Sealed Ball Bearings. The Installation Includes Heavy-Duty Anti-Vibration Ceiling Hangers, Rubber Gaskets On The Duct Collars For Airtight Sealing, And A Matching Speed-Controller Switch. , Supply, Installation, Testing, And Commissioning Of Butterfly Valve (150 Mm / 6 Inch Nominal Bore), Wafer Type, Suitable For Chilled/Hot Water Circulation. The Valve Must Feature A Cast Iron/Ductile Iron Body, An Epdm Seal For Bubble-Tight Shut-Off, And A Stainless Steel Disc And Shaft

BOQ

Sl. No. Item TitleItem Description
1Charges towards the full-service maintenance for the designated air conditioning units to restore peak cooling performance, improve indoor air quality, and optimize energy efficiency. This service includes a complete physical deep clean with pressure washer (indoor & Outdoor units) and a multi-point system diagnostic test.Charges towards the full-service maintenance for the designated air conditioning units to restore peak cooling performance, improve indoor air quality, and optimize energy efficiency. This service includes a complete physical deep clean with pressure washer (indoor & Outdoor units) and a multi-point system diagnostic test.
2Supply and installation of Compressor for 05 TR capacity of ductable AC system.Supply and installation of Compressor for 05 TR capacity of ductable AC system.
3Supply and installation of Outdoor unit fan Motor for 05 TR capacity of ductable Air Conditioners system as requiredSupply and installation of Outdoor unit fan Motor for 05 TR capacity of ductable Air Conditioners system as required
4Supply and installation of Accumulator / Filter Drier for 05 TR capacity of ductable Air Conditioners system as requiredSupply and installation of Accumulator / Filter Drier for 05 TR capacity of ductable Air Conditioners system as required
5Charging of Refrigeration gas of 5 TR ductable Air-Conditioner as per site RequirementCharging of Refrigeration gas of 5 TR ductable Air-Conditioner as per site Requirement
6Supply and installation of contactor of ductable Air Conditioners system as requiredSupply and installation of contactor of ductable Air Conditioners system as required
7Supply, installation, testing, and commissioning of a high-efficiency Evaporator /Condenser Coil designed for 05 TR capacity of ductable Air Conditioners system as per site requirementSupply, installation, testing, and commissioning of a high-efficiency Evaporator /Condenser Coil designed for 05 TR capacity of ductable Air Conditioners system as per site requirement
8Supply, installation, testing, and commissioning of a high-performance Blower Fan assembly designed for 05 TR capacity of ductable Air Conditioners system as per site requirementSupply, installation, testing, and commissioning of a high-performance Blower Fan assembly designed for 05 TR capacity of ductable Air Conditioners system as per site requirement
9Supply, installation, testing, and commissioning of a high-precision Thermostatic Expansion Valve (TXV) for precise refrigerant flow control for 05 TR capacity of ductable Air Conditioners system as per site requirementSupply, installation, testing, and commissioning of a high-precision Thermostatic Expansion Valve (TXV) for precise refrigerant flow control for 05 TR capacity of ductable Air Conditioners system as per site requirement
10Supply, installation, testing, and commissioning of Control Board / PCB for 05 TR capacity of ductable Air Conditioners system as per site requirementSupply, installation, testing, and commissioning of Control Board / PCB for 05 TR capacity of ductable Air Conditioners system as per site requirement
11Supply and installation, of Refrigerant Piping for 05 TR capacity of ductable Air Conditioners system as per site requirementSupply and installation, of Refrigerant Piping for 05 TR capacity of ductable Air Conditioners system as per site requirement
12Supply, installation, testing, and commissioning of other Safety Controls like high/low-pressure switches, sensor and overload protectors etc for 05 TR capacity of ductable Air Conditioners system as per site requirementSupply, installation, testing, and commissioning of other Safety Controls like high/low-pressure switches, sensor and overload protectors etc for 05 TR capacity of ductable Air Conditioners system as per site requirement
13Supply, installation, testing, and commissioning of condensing coil valve for 05 TR capacity of ductable Air Conditioners system as per site requirementSupply, installation, testing, and commissioning of condensing coil valve for 05 TR capacity of ductable Air Conditioners system as per site requirement
14Supply and installation of Compressor for 1.5 to 02 TR capacity of window/ split/ cassette Air Conditioners unitSupply and installation of Compressor for 1.5 to 02 TR capacity of window/ split/ cassette Air Conditioners unit
15Supply and installation of Outdoor unit fan Motor for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirementSupply and installation of Outdoor unit fan Motor for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirement
16Supply and installation of PCB board/ Kit for all type (inverter & Non inverter) Air Conditioner for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirementSupply and installation of PCB board/ Kit for all type (inverter & Non inverter) Air Conditioner for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirement
17Testing and Charging of Refrigeration gas (900g to 1400g) for all type (inverter & Non inverter) Air Conditioner for 1.5 to 02 TR Air Conditioners unit as per site requirementTesting and Charging of Refrigeration gas (900g to 1400g) for all type (inverter & Non inverter) Air Conditioner for 1.5 to 02 TR Air Conditioners unit as per site requirement
18Providing labor, equipment, and materials for the high-pressure Nitrogen (N2) leak testing, pressure holding test for 24 Hr, Brazing Repair (If can be repair) of the AC coil.Providing labor, equipment, and materials for the high-pressure Nitrogen (N2) leak testing, pressure holding test for 24 Hr, Brazing Repair (If can be repair) of the AC coil.
19Supply, installation, testing, and commissioning of a high-efficiency Evaporator /Condenser Coil designed for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirementSupply, installation, testing, and commissioning of a high-efficiency Evaporator /Condenser Coil designed for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirement
20Supply, installation, testing, and commissioning of a high-performance Blower Fan including Louvers/Vanes for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirementSupply, installation, testing, and commissioning of a high-performance Blower Fan including Louvers/Vanes for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirement
21Supply, installation, testing, and commissioning of other Safety Controls like switches, sensor (air and coil) etc for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirementSupply, installation, testing, and commissioning of other Safety Controls like switches, sensor (air and coil) etc for 1.5 to 02 TR capacity of wall type split Air Conditioners unit as per site requirement
22Supply and installation of Motor for 1.5 TR capacity of window Air Conditioner units as per site requirementSupply and installation of Motor for 1.5 TR capacity of window Air Conditioner units as per site requirement
23Supply, installation, testing, and commissioning of a high-efficiency Evaporator /Condenser Coil designed for 1.5 capacity of window Air Conditioners unit as per site requirementSupply, installation, testing, and commissioning of a high-efficiency Evaporator /Condenser Coil designed for 1.5 capacity of window Air Conditioners unit as per site requirement
24Supply, installation, testing, and commissioning of a high-performance Blower Fan including Louvers/Vanes for 1.5 TR capacity of window Air Conditioner units as per site requirementSupply, installation, testing, and commissioning of a high-performance Blower Fan including Louvers/Vanes for 1.5 TR capacity of window Air Conditioner units as per site requirement
25Supply, installation, testing, and commissioning of Control Board / PCB for 1.5 TR capacity of window Air Conditioner units as per site requirementSupply, installation, testing, and commissioning of Control Board / PCB for 1.5 TR capacity of window Air Conditioner units as per site requirement
26Supply and Installation of Copper pipe 1/4\\" dia including nuts, unions, brazing, insulation and compression accessoriesSupply and Installation of Copper pipe 1/4\\" dia including nuts, unions, brazing, insulation and compression accessories
27Supply and Installation of Copper pipe 5/8\\" dia including nuts, unions, brazing and compression accessoriesSupply and Installation of Copper pipe 5/8\\" dia including nuts, unions, brazing and compression accessories
28Supply and Installation of Copper pipe 3/8\\" dia including nuts, unions, brazing and compression accessoriesSupply and Installation of Copper pipe 3/8\\" dia including nuts, unions, brazing and compression accessories
29Supply and Installation of Copper pipe 1/2\\" dia including nuts, unions, brazing and compression accessoriesSupply and Installation of Copper pipe 1/2\\" dia including nuts, unions, brazing and compression accessories
30Supply and Installation of condensing valve for all type (window and split) Air Conditioner up to 05 TR, as per site requirementSupply and Installation of condensing valve for all type (window and split) Air Conditioner up to 05 TR, as per site requirement
31Supply, installation, testing, and commissioning of a high-reliability Digital Voltage Stabilizer (4 KVA, 5 KVA) tailored for Air Conditioner protection as per site requirementSupply, installation, testing, and commissioning of a high-reliability Digital Voltage Stabilizer (4 KVA, 5 KVA) tailored for Air Conditioner protection as per site requirement
32Supply, installation, testing, and commissioning of Condenser 3 to 10 mfd, 230 volts for Indoor unit as per site requirmentSupply, installation, testing, and commissioning of Condenser 3 to 10 mfd, 230 volts for Indoor unit as per site requirment
33Supply, installation, testing, and commissioning of Condenser 50±2, ±4, ±6 mfd, 230 volts for Outdoor unit as per site requirementSupply, installation, testing, and commissioning of Condenser 50±2, ±4, ±6 mfd, 230 volts for Outdoor unit as per site requirement
34Supply and installation of 12 mm to 20 mm drain water pipe (PVC/ flexible)as per site requirement including all fittingsSupply and installation of 12 mm to 20 mm drain water pipe (PVC/ flexible)as per site requirement including all fittings
35Supply and installation of outdoor fan blade as per site requirement including all fittingsSupply and installation of outdoor fan blade as per site requirement including all fittings
36Supplying and fixing wall mounting stand for installation of Outdoor and indoor unit of Split type Air Conditioners as per site requirementSupplying and fixing wall mounting stand for installation of Outdoor and indoor unit of Split type Air Conditioners as per site requirement
37Supply of remotes for Air Conditioners as per site requirementSupply of remotes for Air Conditioners as per site requirement
38Supply, fabrication, routing, installation, testing, and commissioning of Galvanized Sheet Steel (GSS) (18 to 24 Gauge as required) ducting. The rate includes raw material, factory or site fabrication, transverse jointing systems (flanges, cleats, gaskets), neoprene rubber gaskets, sealant, and anchor fasteners. It includes supportive structural hangers, threaded rods, MS angles, and anti-vibration rubber pads.Supply, fabrication, routing, installation, testing, and commissioning of Galvanized Sheet Steel (GSS) (18 to 24 Gauge as required) ducting. The rate includes raw material, factory or site fabrication, transverse jointing systems (flanges, cleats, gaskets), neoprene rubber gaskets, sealant, and anchor fasteners. It includes supportive structural hangers, threaded rods, MS angles, and anti-vibration rubber pads.
39Supply and installation of pre-formed Tubular Closed Cell Nitrile Rubber insulation sleeves over copper refrigerant piping (suction and liquid lines separately)/Air duct. All joints between sleeves must be sealed using specialized adhesive and wrapped with 50-100 mm wide black Nitrile foam tape to ensure a continuous vapour barrier and prevent condensationSupply and installation of pre-formed Tubular Closed Cell Nitrile Rubber insulation sleeves over copper refrigerant piping (suction and liquid lines separately)/Air duct. All joints between sleeves must be sealed using specialized adhesive and wrapped with 50-100 mm wide black Nitrile foam tape to ensure a continuous vapour barrier and prevent condensation
40Supply, installation, testing, and commissioning of a Plug-in Control / Auxiliary Relay for the Air Handling Unit (AHU) control circuit as per the site requirement . The relay must feature a transparent dust-proof polycarbonate cover, an integrated LED status indicator, and a manual test tab. The item must include a matching DIN-rail mounted base socket with screw terminals, installed neatly inside the AHU starter/control panel.Supply, installation, testing, and commissioning of a Plug-in Control / Auxiliary Relay for the Air Handling Unit (AHU) control circuit as per the site requirement . The relay must feature a transparent dust-proof polycarbonate cover, an integrated LED status indicator, and a manual test tab. The item must include a matching DIN-rail mounted base socket with screw terminals, installed neatly inside the AHU starter/control panel.
41Supply, installation, testing, and commissioning of a Double Inlet Double Width (DIDW) Centrifugal Blower / Fan for an Air Handling Unit (AHU) with a capacity up to 6000 CFM. The blower housing and wheel must be fabricated from heavy-gauge galvanized steel sheet (GI) with a corrosion-resistant finish. The assembly must feature a statically and dynamically balanced forward or backward-curved impeller shaft mounted on heavy-duty, self-aligning pillow block bearings with lubrication fittings. The unit includes an adjustable motor mounting base, a matched set of V-belts, cast iron pulleys (taper-lock type), and a heavy-duty GI wire mesh belt guard. The entire fan assembly must be isolated from the AHU casing using fire-retardant flexible canvas connections and mounted on spring vibration isolators.Supply, installation, testing, and commissioning of a Double Inlet Double Width (DIDW) Centrifugal Blower / Fan for an Air Handling Unit (AHU) with a capacity up to 6000 CFM. The blower housing and wheel must be fabricated from heavy-gauge galvanized steel sheet (GI) with a corrosion-resistant finish. The assembly must feature a statically and dynamically balanced forward or backward-curved impeller shaft mounted on heavy-duty, self-aligning pillow block bearings with lubrication fittings. The unit includes an adjustable motor mounting base, a matched set of V-belts, cast iron pulleys (taper-lock type), and a heavy-duty GI wire mesh belt guard. The entire fan assembly must be isolated from the AHU casing using fire-retardant flexible canvas connections and mounted on spring vibration isolators.
42Supply and installation of standard Classical V-Belt (A / B / C / D section) for replacement or new installation in AHU belt-drive systems as per site requirementSupply and installation of standard Classical V-Belt (A / B / C / D section) for replacement or new installation in AHU belt-drive systems as per site requirement
43Supply, installation, testing, and commissioning of a Deep-Pleat HEPA (High-Efficiency Particulate Air) Filter for terminal or in-line mounting within the Air Handling Unit (AHU) filter section (size of 1.5x1.5 ft to 3x3 ) as per site requirementSupply, installation, testing, and commissioning of a Deep-Pleat HEPA (High-Efficiency Particulate Air) Filter for terminal or in-line mounting within the Air Handling Unit (AHU) filter section (size of 1.5x1.5 ft to 3x3 ) as per site requirement
44Providing labour, machinery, and materials for the complete dismantling, comprehensive rewinding, and overhauling of a Three-Phase Squirrel Cage Induction Motor or Monoblock/Submersible Pump Set up to 3 HP Motor capacity. The scope of work includes dismantling, stripping the burnt windings, thorough cleaning and baking of the stator core, and rewinding using premium super-enameled copper wire (Class F/H insulation). The job includes the complete replacement of inter-phase insulation sheets, slot wedges, and heavy-duty varnishing followed by controlled oven baking. The price is all-inclusive of replacing high-grade anti-friction ball/roller bearings, mechanical carbon-ceramic lip seals / water seals, dynamic balancing of the rotor/impeller assembly on a balancing machine, and replacement of elastomeric flexible elements in the shaft coupler. The unit must be reassembled with new hardware, gaskets, and terminal block connectors, followed by testing for insulation resistance (megger test), no-load current, and full-load performance tracking.Providing labour, machinery, and materials for the complete dismantling, comprehensive rewinding, and overhauling of a Three-Phase Squirrel Cage Induction Motor or Monoblock/Submersible Pump Set up to 3 HP Motor capacity. The scope of work includes dismantling, stripping the burnt windings, thorough cleaning and baking of the stator core, and rewinding using premium super-enameled copper wire (Class F/H insulation). The job includes the complete replacement of inter-phase insulation sheets, slot wedges, and heavy-duty varnishing followed by controlled oven baking. The price is all-inclusive of replacing high-grade anti-friction ball/roller bearings, mechanical carbon-ceramic lip seals / water seals, dynamic balancing of the rotor/impeller assembly on a balancing machine, and replacement of elastomeric flexible elements in the shaft coupler. The unit must be reassembled with new hardware, gaskets, and terminal block connectors, followed by testing for insulation resistance (megger test), no-load current, and full-load performance tracking.
45Providing labour, machinery, and materials for the complete dismantling, comprehensive rewinding, and overhauling of a Three-Phase Squirrel Cage Induction Motor or Monoblock/Submersible Pump Set up to 3.5 to 5 HP Motor capacity. The scope of work includes stripping the burnt windings, thorough cleaning and baking of the stator core, and rewinding using premium super-enameled copper wire (Class F/H insulation). The job includes the complete replacement of inter-phase insulation sheets, slot wedges, and heavy-duty varnishing followed by controlled oven baking. The price is all-inclusive of replacing high-grade anti-friction ball/roller bearings, mechanical carbon-ceramic lip seals / water seals, dynamic balancing of the rotor/impeller assembly on a balancing machine, and replacement of elastomeric flexible elements in the shaft coupler. The unit must be reassembled with new hardware, gaskets, and terminal block connectors, followed by testing for insulation resistance (megger test), no-load current, and full-load performance tracking.Providing labour, machinery, and materials for the complete dismantling, comprehensive rewinding, and overhauling of a Three-Phase Squirrel Cage Induction Motor or Monoblock/Submersible Pump Set up to 3.5 to 5 HP Motor capacity. The scope of work includes stripping the burnt windings, thorough cleaning and baking of the stator core, and rewinding using premium super-enameled copper wire (Class F/H insulation). The job includes the complete replacement of inter-phase insulation sheets, slot wedges, and heavy-duty varnishing followed by controlled oven baking. The price is all-inclusive of replacing high-grade anti-friction ball/roller bearings, mechanical carbon-ceramic lip seals / water seals, dynamic balancing of the rotor/impeller assembly on a balancing machine, and replacement of elastomeric flexible elements in the shaft coupler. The unit must be reassembled with new hardware, gaskets, and terminal block connectors, followed by testing for insulation resistance (megger test), no-load current, and full-load performance tracking.
46Providing labor, machinery, and materials for the complete dismantling, comprehensive rewinding, and overhauling of a Three-Phase Squirrel Cage Induction Motor or Monoblock/Submersible Pump Set 5.5 to 7.5 HP Motor capacity. The scope of work includes stripping the burnt windings, thorough cleaning and baking of the stator core, and rewinding using premium super-enameled copper wire (Class F/H insulation). The job includes the complete replacement of inter-phase insulation sheets, slot wedges, and heavy-duty varnishing followed by controlled oven baking. The price is all-inclusive of replacing high-grade anti-friction ball/roller bearings, mechanical carbon-ceramic lip seals / water seals, dynamic balancing of the rotor/impeller assembly on a balancing machine, and replacement of elastomeric flexible elements in the shaft coupler. The unit must be reassembled with new hardware, gaskets, and terminal block connectors, followed by testing for insulation resistance (megger test), no-load current, and full-load performance tracking.Providing labor, machinery, and materials for the complete dismantling, comprehensive rewinding, and overhauling of a Three-Phase Squirrel Cage Induction Motor or Monoblock/Submersible Pump Set 5.5 to 7.5 HP Motor capacity. The scope of work includes stripping the burnt windings, thorough cleaning and baking of the stator core, and rewinding using premium super-enameled copper wire (Class F/H insulation). The job includes the complete replacement of inter-phase insulation sheets, slot wedges, and heavy-duty varnishing followed by controlled oven baking. The price is all-inclusive of replacing high-grade anti-friction ball/roller bearings, mechanical carbon-ceramic lip seals / water seals, dynamic balancing of the rotor/impeller assembly on a balancing machine, and replacement of elastomeric flexible elements in the shaft coupler. The unit must be reassembled with new hardware, gaskets, and terminal block connectors, followed by testing for insulation resistance (megger test), no-load current, and full-load performance tracking.
47Comprehensive overhauling, servicing, and testing of 5 HP to 7.5 HP capacity water pumps (including centrifugal, submersible, and monoblock types) to restore optimal operating efficiency. The scope of work include the replacement of bearing, seal, coupler, oil and greasing, Alignment & Balancing as requirementComprehensive overhauling, servicing, and testing of 5 HP to 7.5 HP capacity water pumps (including centrifugal, submersible, and monoblock types) to restore optimal operating efficiency. The scope of work include the replacement of bearing, seal, coupler, oil and greasing, Alignment & Balancing as requirement
48Supply, installation, testing, and commissioning of an Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan designed for direct installation into an 8-inch (200 mm) ventilation duct including aal nassesory fittings like MCB, switch Wire etc. The fan housing must feature a heavy-duty, aerodynamic double-walled casing lined internally with high-density, sound-absorbing acoustic foam or fiberglass insulation to break sound waves and ensure ultra-quiet operation. The impeller must be a high-shroud, mixed-flow design optimized to deliver maximum CFM against high static pressure. The central motor-impeller block must feature a quick-release \\"pull-out\\" design, allowing complete maintenance without dismantling the connected ductwork. The motor must be an external rotor type with integrated thermal overload protection, class F insulation, and permanently lubricated sealed ball bearings. The installation includes heavy-duty anti-vibration ceiling hangers, rubber gaskets on the duct collars for airtight sealing, and a matching speed-controller switch.Supply, installation, testing, and commissioning of an Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan designed for direct installation into an 8-inch (200 mm) ventilation duct including aal nassesory fittings like MCB, switch Wire etc. The fan housing must feature a heavy-duty, aerodynamic double-walled casing lined internally with high-density, sound-absorbing acoustic foam or fiberglass insulation to break sound waves and ensure ultra-quiet operation. The impeller must be a high-shroud, mixed-flow design optimized to deliver maximum CFM against high static pressure. The central motor-impeller block must feature a quick-release \\"pull-out\\" design, allowing complete maintenance without dismantling the connected ductwork. The motor must be an external rotor type with integrated thermal overload protection, class F insulation, and permanently lubricated sealed ball bearings. The installation includes heavy-duty anti-vibration ceiling hangers, rubber gaskets on the duct collars for airtight sealing, and a matching speed-controller switch.
49Supply, installation, testing, and commissioning of an Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan designed for direct installation into an 6-inch (200 mm) ventilation duct including aal nassesory fittings like MCB, switch Wire etc. The fan housing must feature a heavy-duty, aerodynamic double-walled casing lined internally with high-density, sound-absorbing acoustic foam or fiberglass insulation to break sound waves and ensure ultra-quiet operation. The impeller must be a high-shroud, mixed-flow design optimized to deliver maximum CFM against high static pressure. The central motor-impeller block must feature a quick-release \\"pull-out\\" design, allowing complete maintenance without dismantling the connected ductwork. The motor must be an external rotor type with integrated thermal overload protection, class F insulation, and permanently lubricated sealed ball bearings. The installation includes heavy-duty anti-vibration ceiling hangers, rubber gaskets on the duct collars for airtight sealing, and a matching speed-controller switch.Supply, installation, testing, and commissioning of an Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan designed for direct installation into an 6-inch (200 mm) ventilation duct including aal nassesory fittings like MCB, switch Wire etc. The fan housing must feature a heavy-duty, aerodynamic double-walled casing lined internally with high-density, sound-absorbing acoustic foam or fiberglass insulation to break sound waves and ensure ultra-quiet operation. The impeller must be a high-shroud, mixed-flow design optimized to deliver maximum CFM against high static pressure. The central motor-impeller block must feature a quick-release \\"pull-out\\" design, allowing complete maintenance without dismantling the connected ductwork. The motor must be an external rotor type with integrated thermal overload protection, class F insulation, and permanently lubricated sealed ball bearings. The installation includes heavy-duty anti-vibration ceiling hangers, rubber gaskets on the duct collars for airtight sealing, and a matching speed-controller switch.
50Supply, installation, testing, and commissioning of Butterfly Valve (150 mm / 6 Inch Nominal Bore), wafer type, suitable for chilled/hot water circulation. The valve must feature a cast iron/ductile iron body, an EPDM seal for bubble-tight shut-off, and a stainless steel disc and shaftSupply, installation, testing, and commissioning of Butterfly Valve (150 mm / 6 Inch Nominal Bore), wafer type, suitable for chilled/hot water circulation. The valve must feature a cast iron/ductile iron body, an EPDM seal for bubble-tight shut-off, and a stainless steel disc and shaft

AI Tender Summary

OUR REF NO 58376019
AUTHORITY Government Departments
TENDER VALUE 22.01 Lakhs
LAST DATE 14-11-2026
Authority
Authority Name Indian Renewable Energy Development Agency Limited
Work Description Bids Are invited for Annual Maintenance Service-Air Conditioner - Charges Towards The Full-Service Maintenance For The Designated Air Conditioning Units To Restore Peak Cooling Performance, Improve Indoor Air Quality, And Optimize Energy Efficiency. This Service Includes A Complete Physical Deep Clean With Pressure Washer (Indoor & Outdoor Units) And A Multi-Point System Diagnostic Test. , Supply And Installation Of Compressor For 05 Tr Capacity Of Ductable Ac System. , Supply And Installation Of Outdoor Unit Fan Motor For 05 Tr Capacity Of Ductable Air Conditioners System As Required , Supply And Installation Of Accumulator / Filter Drier For 05 Tr Capacity Of Ductable Air Conditioners System As Required , Charging Of Refrigeration Gas Of 5 Tr Ductable Air-Conditioner As Per Site Requirement , Supply And Installation Of Contactor Of Ductable Air Conditioners System As Required , Supply, Installation, Testing, And Commissioning Of A High-Efficiency Evaporator /Condenser Coil Designed For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Performance Blower Fan Assembly Designed For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Precision Thermostatic Expansion Valve (Txv) For Precise Refrigerant Flow Control For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Control Board / Pcb For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply And Installation, Of Refrigerant Piping For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Other Safety Controls Like High/Low-Pressure Switches, Sensor And Overload Protectors Etc For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Condensing Coil Valve For 05 Tr Capacity Of Ductable Air Conditioners System As Per Site Requirement , Supply And Installation Of Compressor For 1.5 To 02 Tr Capacity Of Window/ Split/ Cassette Air Conditioners Unit , Supply And Installation Of Outdoor Unit Fan Motor For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply And Installation Of Pcb Board/ Kit For All Type (Inverter & Non Inverter) Air Conditioner For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Testing And Charging Of Refrigeration Gas (900G To 1400G) For All Type (Inverter & Non Inverter) Air Conditioner For 1.5 To 02 Tr Air Conditioners Unit As Per Site Requirement , Providing Labor, Equipment, And Materials For The High-Pressure Nitrogen (N2) Leak Testing, Pressure Holding Test For 24 Hr, Brazing Repair (If Can Be Repair) Of The Ac Coil. , Supply, Installation, Testing, And Commissioning Of A High-Efficiency Evaporator /Condenser Coil Designed For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Performance Blower Fan Including Louvers/Vanes For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Other Safety Controls Like Switches, Sensor (Air And Coil) Etc For 1.5 To 02 Tr Capacity Of Wall Type Split Air Conditioners Unit As Per Site Requirement , Supply And Installation Of Motor For 1.5 Tr Capacity Of Window Air Conditioner Units As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Efficiency Evaporator /Condenser Coil Designed For 1.5 Capacity Of Window Air Conditioners Unit As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Performance Blower Fan Including Louvers/Vanes For 1.5 Tr Capacity Of Window Air Conditioner Units As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Control Board / Pcb For 1.5 Tr Capacity Of Window Air Conditioner Units As Per Site Requirement , Supply And Installation Of Copper Pipe 1/4 Dia Including Nuts, Unions, Brazing, Insulation And Compression Accessories , Supply And Installation Of Copper Pipe 5/8 Dia Including Nuts, Unions, Brazing And Compression Accessories , Supply And Installation Of Copper Pipe 3/8 Dia Including Nuts, Unions, Brazing And Compression Accessories , Supply And Installation Of Copper Pipe 1/2 Dia Including Nuts, Unions, Brazing And Compression Accessories , Supply And Installation Of Condensing Valve For All Type (Window And Split) Air Conditioner Up To 05 Tr, As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A High-Reliability Digital Voltage Stabilizer (4 Kva, 5 Kva) Tailored For Air Conditioner Protection As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of Condenser 3 To 10 Mfd, 230 Volts For Indoor Unit As Per Site Requirment , Supply, Installation, Testing, And Commissioning Of Condenser 50±2, ±4, ±6 Mfd, 230 Volts For Outdoor Unit As Per Site Requirement , Supply And Installation Of 12 Mm To 20 Mm Drain Water Pipe (Pvc/ Flexible)As Per Site Requirement Including All Fittings , Supply And Installation Of Outdoor Fan Blade As Per Site Requirement Including All Fittings , Supplying And Fixing Wall Mounting Stand For Installation Of Outdoor And Indoor Unit Of Split Type Air Conditioners As Per Site Requirement , Supply Of Remotes For Air Conditioners As Per Site Requirement , Supply, Fabrication, Routing, Installation, Testing, And Commissioning Of Galvanized Sheet Steel (Gss) (18 To 24 Gauge As Required) Ducting. The Rate Includes Raw Material, Factory Or Site Fabrication, Transverse Jointing Systems (Flanges, Cleats, Gaskets), Neoprene Rubber Gaskets, Sealant, And Anchor Fasteners. It Includes Supportive Structural Hangers, Threaded Rods, Ms Angles, And Anti-Vibration Rubber Pads. , Supply And Installation Of Pre-Formed Tubular Closed Cell Nitrile Rubber Insulation Sleeves Over Copper Refrigerant Piping (Suction And Liquid Lines Separately)/Air Duct. All Joints Between Sleeves Must Be Sealed Using Specialized Adhesive And Wrapped With 50-100 Mm Wide Black Nitrile Foam Tape To Ensure A Continuous Vapour Barrier And Prevent Condensation , Supply, Installation, Testing, And Commissioning Of A Plug-In Control / Auxiliary Relay For The Air Handling Unit (Ahu) Control Circuit As Per The Site Requirement . The Relay Must Feature A Transparent Dust-Proof Polycarbonate Cover, An Integrated Led Status Indicator, And A Manual Test Tab. The Item Must Include A Matching Din-Rail Mounted Base Socket With Screw Terminals, Installed Neatly Inside The Ahu Starter/Control Panel. , Supply, Installation, Testing, And Commissioning Of A Double Inlet Double Width (Didw) Centrifugal Blower / Fan For An Air Handling Unit (Ahu) With A Capacity Up To 6000 Cfm. The Blower Housing And Wheel Must Be Fabricated From Heavy-Gauge Galvanized Steel Sheet (Gi) With A Corrosion-Resistant Finish. The Assembly Must Feature A Statically And Dynamically Balanced Forward Or Backward-Curved Impeller Shaft Mounted On Heavy-Duty, Self-Aligning Pillow Block Bearings With Lubrication Fittings. The Unit Includes An Adjustable Motor Mounting Base, A Matched Set Of V-Belts, Cast Iron Pulleys (Taper-Lock Type), And A Heavy-Duty Gi Wire Mesh Belt Guard. The Entire Fan Assembly Must Be Isolated From The Ahu Casing Using Fire-Retardant Flexible Canvas Connections And Mounted On Spring Vibration Isolators. , Supply And Installation Of Standard Classical V-Belt (A / B / C / D Section) For Replacement Or New Installation In Ahu Belt-Drive Systems As Per Site Requirement , Supply, Installation, Testing, And Commissioning Of A Deep-Pleat Hepa (High-Efficiency Particulate Air) Filter For Terminal Or In-Line Mounting Within The Air Handling Unit (Ahu) Filter Section (Size Of 1.5X1.5 Ft To 3X3 ) As Per Site Requirement , Providing Labour, Machinery, And Materials For The Complete Dismantling, Comprehensive Rewinding, And Overhauling Of A Three-Phase Squirrel Cage Induction Motor Or Monoblock/Submersible Pump Set Up To 3 Hp Motor Capacity. The Scope Of Work Includes Dismantling, Stripping The Burnt Windings, Thorough Cleaning And Baking Of The Stator Core, And Rewinding Using Premium Super-Enameled Copper Wire (Class F/H Insulation). The Job Includes The Complete Replacement Of Inter-Phase Insulation Sheets, Slot Wedges, And Heavy-Duty Varnishing Followed By Controlled Oven Baking. The Price Is All-Inclusive Of Replacing High-Grade Anti-Friction Ball/Roller Bearings, Mechanical Carbon-Ceramic Lip Seals / Water Seals, Dynamic Balancing Of The Rotor/Impeller Assembly On A Balancing Machine, And Replacement Of Elastomeric Flexible Elements In The Shaft Coupler. The Unit Must Be Reassembled With New Hardware, Gaskets, And Terminal Block Connectors, Followed By Testing For Insulation Resistance (Megger Test), No-Load Current, And Full-Load Performance Tracking. , Providing Labour, Machinery, And Materials For The Complete Dismantling, Comprehensive Rewinding, And Overhauling Of A Three-Phase Squirrel Cage Induction Motor Or Monoblock/Submersible Pump Set Up To 3.5 To 5 Hp Motor Capacity. The Scope Of Work Includes Stripping The Burnt Windings, Thorough Cleaning And Baking Of The Stator Core, And Rewinding Using Premium Super-Enameled Copper Wire (Class F/H Insulation). The Job Includes The Complete Replacement Of Inter-Phase Insulation Sheets, Slot Wedges, And Heavy-Duty Varnishing Followed By Controlled Oven Baking. The Price Is All-Inclusive Of Replacing High-Grade Anti-Friction Ball/Roller Bearings, Mechanical Carbon-Ceramic Lip Seals / Water Seals, Dynamic Balancing Of The Rotor/Impeller Assembly On A Balancing Machine, And Replacement Of Elastomeric Flexible Elements In The Shaft Coupler. The Unit Must Be Reassembled With New Hardware, Gaskets, And Terminal Block Connectors, Followed By Testing For Insulation Resistance (Megger Test), No-Load Current, And Full-Load Performance Tracking. , Providing Labor, Machinery, And Materials For The Complete Dismantling, Comprehensive Rewinding, And Overhauling Of A Three-Phase Squirrel Cage Induction Motor Or Monoblock/Submersible Pump Set 5.5 To 7.5 Hp Motor Capacity. The Scope Of Work Includes Stripping The Burnt Windings, Thorough Cleaning And Baking Of The Stator Core, And Rewinding Using Premium Super-Enameled Copper Wire (Class F/H Insulation). The Job Includes The Complete Replacement Of Inter-Phase Insulation Sheets, Slot Wedges, And Heavy-Duty Varnishing Followed By Controlled Oven Baking. The Price Is All-Inclusive Of Replacing High-Grade Anti-Friction Ball/Roller Bearings, Mechanical Carbon-Ceramic Lip Seals / Water Seals, Dynamic Balancing Of The Rotor/Impeller Assembly On A Balancing Machine, And Replacement Of Elastomeric Flexible Elements In The Shaft Coupler. The Unit Must Be Reassembled With New Hardware, Gaskets, And Terminal Block Connectors, Followed By Testing For Insulation Resistance (Megger Test), No-Load Current, And Full-Load Performance Tracking. , Comprehensive Overhauling, Servicing, And Testing Of 5 Hp To 7.5 Hp Capacity Water Pumps (Including Centrifugal, Submersible, And Monoblock Types) To Restore Optimal Operating Efficiency. The Scope Of Work Include The Replacement Of Bearing, Seal, Coupler, Oil And Greasing, Alignment & Balancing As Requirement , Supply, Installation, Testing, And Commissioning Of An Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan Designed For Direct Installation Into An 8-Inch (200 Mm) Ventilation Duct Including Aal Nassesory Fittings Like Mcb, Switch Wire Etc. The Fan Housing Must Feature A Heavy-Duty, Aerodynamic Double-Walled Casing Lined Internally With High-Density, Sound-Absorbing Acoustic Foam Or Fiberglass Insulation To Break Sound Waves And Ensure Ultra-Quiet Operation. The Impeller Must Be A High-Shroud, Mixed-Flow Design Optimized To Deliver Maximum Cfm Against High Static Pressure. The Central Motor-Impeller Block Must Feature A Quick-Release Pull-Out Design, Allowing Complete Maintenance Without Dismantling The Connected Ductwork. The Motor Must Be An External Rotor Type With Integrated Thermal Overload Protection, Class F Insulation, And Permanently Lubricated Sealed Ball Bearings. The Installation Includes Heavy-Duty Anti-Vibration Ceiling Hangers, Rubber Gaskets On The Duct Collars For Airtight Sealing, And A Matching Speed-Controller Switch. , Supply, Installation, Testing, And Commissioning Of An Acoustically Insulated, High-Capacity Mixed-Flow Inline Duct Fan Designed For Direct Installation Into An 6-Inch (200 Mm) Ventilation Duct Including Aal Nassesory Fittings Like Mcb, Switch Wire Etc. The Fan Housing Must Feature A Heavy-Duty, Aerodynamic Double-Walled Casing Lined Internally With High-Density, Sound-Absorbing Acoustic Foam Or Fiberglass Insulation To Break Sound Waves And Ensure Ultra-Quiet Operation. The Impeller Must Be A High-Shroud, Mixed-Flow Design Optimized To Deliver Maximum Cfm Against High Static Pressure. The Central Motor-Impeller Block Must Feature A Quick-Release Pull-Out Design, Allowing Complete Maintenance Without Dismantling The Connected Ductwork. The Motor Must Be An External Rotor Type With Integrated Thermal Overload Protection, Class F Insulation, And Permanently Lubricated Sealed Ball Bearings. The Installation Includes Heavy-Duty Anti-Vibration Ceiling Hangers, Rubber Gaskets On The Duct Collars For Airtight Sealing, And A Matching Speed-Controller Switch. , Supply, Installation, Testing, And Commissioning Of Butterfly Valve (150 Mm / 6 Inch Nominal Bore), Wafer Type, Suitable For Chilled/Hot Water Circulation. The Valve Must Feature A Cast Iron/Ductile Iron Body, An Epdm Seal For Bubble-Tight Shut-Off, And A Stainless Steel Disc And Shaft
Basic Detail
Tender No GEM/2026/B/8005917
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 04 Nov 2026
Submission Date 14 Nov 2026
Open Date 15 Nov 2026
Finance
Tender Value 22.01 Lakhs
Tender Fee Ref. Documents
EMD 44028
Exemption Available
Document List
6a2574ca-e7a2-4cef-b997-6130d9cfe07f.pdf
1793789474.xlsx
1793789047.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

6a2574ca-e7a2-4cef-b997-6130d9cfe07f.pdf

xlsx

1793789474.xlsx

pdf

1793789047.pdf

Disclaimer