Banking and Finance Government Departments Closing in 5 days TDR #58375708

Bids Are invited for Tender For Ac Works At Mandi Smiti Branch Unnao Up

Issued by Government Departments · Kanpur, Uttar Pradesh
Tender Value
6.07 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
5 days left
EMD
6000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
413

Project Description

Bids Are invited for Tender For Ac Works At Mandi Smiti Branch Unnao Up Hi Wall Split Ac 2.0 Tr 5 Star , Hi Wall Split Ac 1.5 Tr 5 Star , Hi Wall Split Ac 1.0 Tr 5 Star , Installation Of Hi Wall Split Ac , Additional Copper Pipe For Hi Wall Split Ac , Cable For Hi Wall Split Ac , Drain Pipe 25 Mm , Drain Pipe 32 Mm , Outdoor Stand , Stabiliser 5 Kva 2Tr Ac , Stabiliser 4 Kva For 1.5 Or 1 Tr Ac , Timer Panel , Core Cutting - Hi Wall Split Ac 2.0 Tr 5 Star - Supply Of 2.0 Tr Hi Wall Type Bee Rated 5 Star Inverter Technology Split Air Conditioner. Refer Technical Specification For Details. , Hi Wall Split Ac 1.5 Tr 5 Star - Supply Of 1.5 Tr Hi Wall Type Bee Rated 5 Star Inverter Technology Split Air Conditioner. Refer Technical Specification For Details. , Hi Wall Split Ac 1.0 Tr 5 Star - Supply Of 1.0 Tr Hi Wall Type Bee Rated 5 Star Inverter Technology Split Air Conditioner. Refer Technical Specification For Details. , Installation Of Hi Wall Split Ac - Installation, Testing And Commissioning Of 2/ 1.5/ 1 Tr Hi Wall Type Split/Window Air Conditioner/ Old Ac Dismantled From Branch With Wall Cutting/ Mounting, Stabiliser And Making Good Of Damages Complete In All Respects. For Old Ac Dismentling Also To Be Done. , Additional Copper Pipe For Hi Wall Split Ac - Supply, Installation, Testing And Commissioning Of Insulated Copper Refrigerant Piping Set (Suction And Discharge) Duly Insulated By Nitrile Rubber For 2/ 1.5/ 1 Tr Hi Wall Split Ac. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification For Details. , Cable For Hi Wall Split Ac - Supply, Installation, Testing And Commissioning Of Inter Connecting Wiring/ Cabling Between Indoor And Outdoor Of Hi Wall Split Ac (Power Supply Will Be Made Available At The Outdoor Unit, Please Quote Accordingly). , Drain Pipe 25 Mm - Supply, Installation, Testing And Commissioning Of Pvc 25 Mm Water Pipe With Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. , Drain Pipe 32 Mm - Supply, Installation, Testing And Commissioning Of Pvc 32 Mm Water Pipe With Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. , Outdoor Stand - Supply And Installation Of Robust Ms Angle, Ms Flat Fabricated Floor/ Wall Mounting Stand Suitable For Outdoor Units. Refer Technical Specification For Details. , Stabiliser 5 Kva 2Tr Ac - Supply Of 5 Kva, Wall Mounted Hi Lo Cut Off Stabiliser With Tdr, Voltage Range 140-280V, Complete In All Respects. Refer Technical Specification For Details. , Stabiliser 4 Kva For 1.5 Or 1 Tr Ac - Supply Of 4 Kva, Wall Mounted Hi Lo Cut Off Stabiliser With Tdr, Voltage Range 140-280V, Complete In All Respects. Refer Technical Specification For Details. , Timer Panel - Supply Of Company Made 40 A 3Pole/230 V Analog Time Switch Panel(Timer), Complete In All Respects. Refer Technical Specification For Details. , Core Cutting - Core Cutting/ Wall Chiseling Upto 75Mm Width And 50 Mm Depth For Concealing The Copper Pipe, Drain Pipe And Conduit Either On Wall Or Under Floor Including Making Good Of Damages With Plaster, Putti And Paint.

BOQ

Sl. No. Item TitleItem Description
1Hi wall Split AC 2.0 Tr 5 starSupply of 2.0 Tr hi wall type BEE rated 5 star inverter technology split air conditioner. Refer technical specification for details.
2Hi wall Split AC 1.5 Tr 5 starSupply of 1.5 Tr hi wall type BEE rated 5 star inverter technology split air conditioner. Refer technical specification for details.
3Hi wall Split AC 1.0 Tr 5 starSupply of 1.0 Tr hi wall type BEE rated 5 star inverter technology split air conditioner. Refer technical specification for details.
4Installation of Hi wall Split ACInstallation, testing and commissioning of 2/ 1.5/ 1 TR Hi wall type split/window air conditioner/ old AC dismantled from branch with wall cutting/ mounting, stabiliser and making good of damages complete in all respects. For old AC dismentling also to be done.
5Additional Copper pipe for Hi wall split ACSupply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 2/ 1.5/ 1 TR hi wall split AC. Size (thickness and diameter) of both Copper pipes. Refer technical specification for details.
6Cable for Hi wall split ACSupply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of hi wall split AC (power supply will be made available at the outdoor unit, please quote accordingly).
7Drain pipe 25 mmSupply, installation, testing and commissioning of PVC 25 mm water pipe with accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages.
8Drain pipe 32 mmSupply, installation, testing and commissioning of PVC 32 mm water pipe with accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages.
9Outdoor StandSupply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for outdoor units. Refer technical specification for details.
10Stabiliser 5 KVA 2Tr ACSupply of 5 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details.
11Stabiliser 4 KVA for 1.5 or 1 Tr ACSupply of 4 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details.
12Timer panelSupply of company made 40 A 3pole/230 V analog time switch panel(TIMER), complete in all respects. Refer technical specification for details.
13Core CuttingCore cutting/ wall chiseling upto 75mm width and 50 mm depth for concealing the copper pipe, drain pipe and conduit either on wall or under floor including making good of damages with plaster, putti and paint.

AI Tender Summary

OUR REF NO 58375708
AUTHORITY Government Departments
TENDER VALUE 6.07 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name State Bank Of India
Work Description Bids Are invited for Tender For Ac Works At Mandi Smiti Branch Unnao Up Hi Wall Split Ac 2.0 Tr 5 Star , Hi Wall Split Ac 1.5 Tr 5 Star , Hi Wall Split Ac 1.0 Tr 5 Star , Installation Of Hi Wall Split Ac , Additional Copper Pipe For Hi Wall Split Ac , Cable For Hi Wall Split Ac , Drain Pipe 25 Mm , Drain Pipe 32 Mm , Outdoor Stand , Stabiliser 5 Kva 2Tr Ac , Stabiliser 4 Kva For 1.5 Or 1 Tr Ac , Timer Panel , Core Cutting - Hi Wall Split Ac 2.0 Tr 5 Star - Supply Of 2.0 Tr Hi Wall Type Bee Rated 5 Star Inverter Technology Split Air Conditioner. Refer Technical Specification For Details. , Hi Wall Split Ac 1.5 Tr 5 Star - Supply Of 1.5 Tr Hi Wall Type Bee Rated 5 Star Inverter Technology Split Air Conditioner. Refer Technical Specification For Details. , Hi Wall Split Ac 1.0 Tr 5 Star - Supply Of 1.0 Tr Hi Wall Type Bee Rated 5 Star Inverter Technology Split Air Conditioner. Refer Technical Specification For Details. , Installation Of Hi Wall Split Ac - Installation, Testing And Commissioning Of 2/ 1.5/ 1 Tr Hi Wall Type Split/Window Air Conditioner/ Old Ac Dismantled From Branch With Wall Cutting/ Mounting, Stabiliser And Making Good Of Damages Complete In All Respects. For Old Ac Dismentling Also To Be Done. , Additional Copper Pipe For Hi Wall Split Ac - Supply, Installation, Testing And Commissioning Of Insulated Copper Refrigerant Piping Set (Suction And Discharge) Duly Insulated By Nitrile Rubber For 2/ 1.5/ 1 Tr Hi Wall Split Ac. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification For Details. , Cable For Hi Wall Split Ac - Supply, Installation, Testing And Commissioning Of Inter Connecting Wiring/ Cabling Between Indoor And Outdoor Of Hi Wall Split Ac (Power Supply Will Be Made Available At The Outdoor Unit, Please Quote Accordingly). , Drain Pipe 25 Mm - Supply, Installation, Testing And Commissioning Of Pvc 25 Mm Water Pipe With Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. , Drain Pipe 32 Mm - Supply, Installation, Testing And Commissioning Of Pvc 32 Mm Water Pipe With Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. , Outdoor Stand - Supply And Installation Of Robust Ms Angle, Ms Flat Fabricated Floor/ Wall Mounting Stand Suitable For Outdoor Units. Refer Technical Specification For Details. , Stabiliser 5 Kva 2Tr Ac - Supply Of 5 Kva, Wall Mounted Hi Lo Cut Off Stabiliser With Tdr, Voltage Range 140-280V, Complete In All Respects. Refer Technical Specification For Details. , Stabiliser 4 Kva For 1.5 Or 1 Tr Ac - Supply Of 4 Kva, Wall Mounted Hi Lo Cut Off Stabiliser With Tdr, Voltage Range 140-280V, Complete In All Respects. Refer Technical Specification For Details. , Timer Panel - Supply Of Company Made 40 A 3Pole/230 V Analog Time Switch Panel(Timer), Complete In All Respects. Refer Technical Specification For Details. , Core Cutting - Core Cutting/ Wall Chiseling Upto 75Mm Width And 50 Mm Depth For Concealing The Copper Pipe, Drain Pipe And Conduit Either On Wall Or Under Floor Including Making Good Of Damages With Plaster, Putti And Paint.
Basic Detail
Tender No GEM/2026/B/8235860
Bidding Type Tender
Location
City Kanpur
State Uttar Pradesh
Key Dates
Publish Date 04 Nov 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 6.07 Lakhs
Tender Fee Ref. Documents
EMD 6000
Exemption Not Available
Document List
f4204ebd-3093-4ff7-844f-2cd956fcc63e.pdf
1793708070.xlsx
specifications__ac__works_2026-11-03-17-37-47_4d51f146ca89215336a5c959e8c9ee2a.pdf
10121999_Boq_1.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

f4204ebd-3093-4ff7-844f-2cd956fcc63e.pdf

xlsx

1793708070.xlsx

pdf

specifications__ac__works_2026-11-03-17-37-47_4d51f146ca89215336a5c959e8c9ee2a.pdf

xlsx

10121999_Boq_1.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender