Tender For Provision And Extension Of Perimeter Road Inside Technical Area At Afs Kumbhirgam
Tender Value
60.63 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
28 days left
EMD
1.01 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision And Extension Of Perimeter Road Inside Technical Area At Afs Kumbhirgam
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in Soft/loose soil all as directed and specified. |
| 2 | Add to (or deduct from) item No 1 for every 3 cm or part thereof above or below 15 cm average depth |
| 3 | Rolling and consolidating to required gradient and camber of formation surfaces in cutting with power roller Exc 8 tonne & n exc 12 tonne complete all as specified and as directed. |
| 4 | M & L for 150 mm Soling (or sub base) with broken boulders or quarried stone, inter stices filled,surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed. |
| 5 | M & L for 150mm thick WBM in two layers 75mm thick each (compacted thickness), with coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size) Granite trap or Basalt stone, spread, levelled rolled and consolidated to required etc.. |
| 6 | M & L for preparing Unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and directed. |
| 7 | M & L for applying evenly a priming/tack coat with bituminous primer at 10 kg per 10 sq metre complete all as specified and directed. |
| 8 | M & L for applying evenly a priming/tack coat with bituminous primer at 5 kg per 10 sq metre complete all as specified and directed. |
| 9 | M & L for premixed BM 50mm (consolidated thickness) using 4.0% of binder content by weight of total mix, layed, rolled and compacted to required camber and gradient complete all as specified and directed. |
| 10 | M & L for bituminous premixed SDAC 40mm (consolidated thickness) using 5.5% of binder content by weight of total mix, layed, rolled and compacted to required camber and gradient complete all as specified and directed. |
| 11 | M & L for continuous brick edging with width equal to the depth of the brick, laid dry, on edge with sub class B old size bricks, complete all as specified and directed. |
| 12 | M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 13 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. |
| 14 | M&L for plain Cement concrete 1:4:8 type D2 using 40mm aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 15 | M&L for RCC (M-25 Design Mix) 20mm aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 16 | M&L for RCC (M-25 Design Mix) 20mm aggregate for Walls, retaining walls, basement walls, ballastwalls and the like; any thickness; above top of footings; including attached pilasters and buttresses, complete all as specified and directed. |
| 17 | M&L for RCC (M-25 Design Mix) 20mm aggregate slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 18 | Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter. |
| 19 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 20 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 21 | S & F for cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. complete all as specified and directed. |
| 22 | S & F Plastic Speed Bump designed so dynamically and compact that it can bear maximum load on it. It is made of PE plastic material. Two highly reflective reflectors moulded in PMMA material with ABS base plate through ultrasonic welding process and then fixed on the speed bump so that dust and water cannot touch the reflectors inside area and thus it maintains its reflectivity for a long time. 04 Nos metallic bolts are used for installation on road. Available in Yellow and Black colours. Dimension : L=750mm, width=250mm & Height=75mm ; to be installed as per the directions : of Engineers-in-Charge. (Make :- DARK EYE, Oscar or equivalent) |
| 23 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft /loose soil, complete all as specified and directed. |
| 24 | M&L for plain Cement concrete 1:3:6 type C2, using 40mm aggregate as in foundations, filling and mass concrete, complete all as specified and directed. |
| 25 | M&L for Brickwork with subclass ‘B’ bricks (old size), straight or curved on plan exc 6m mean radius built in CM 1:4, complete all as specified and directed. |
| 26 | M&L for providing, plain cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate as in lintels upto 1.5m clear span, coping and like, etc seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating use of form work and finishing the concrete surfaces complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces including finishing the surface even and smooth w/o using extra cement, complete all as specified and directed. |
| 28 | M&L for preparing new plastered surface for three coats of white wash, complete all as specified and directed. |
| 29 | M&L walling of random rubble, uncoursed as in well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and directed. |
| 30 | M&L for laying of reinforced concrete pipes, class NP3, 600mm dia laid and jointed complete with collars complete all as specified and directed. |
| 31 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil all as specified and directed. |
| 32 | Removing excavated material to a distance exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 33 | Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth and getting out in any type of soil complete all as specified and directed. |
| 34 | Material & Labour for Sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable. Complete all as specified in clause 19.75 of SSR 2009 Part-I (Specifications) complete all as specified and directed |
| 35 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all specified and directed. |
| 36 | Supply, fixing and testing of LED lighting luminaires for street lighting out door type energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65/66 roadway luminaire with high power LED with lens / secondary optics as light source of 60 Watt Suitable for pole dia Ø 43 mm (max) including fabrication of existing pipe bracket wherever required complete all as specified and directed. |
| 37 | S & F cable junction boxes weather proof for outdoor installation for loop connection of street light cable of size 155x210x92 mm with 5 pole terminals fixed on pole steel/PCC with suitable two flat iron clamp 25x4mm with nuts and bolts (duly painted with two coats of aluminium paint over a coat of red oxide primer) including provision for cable entry and exit and making holes on steel pole where required or directed, including dismantling old one complete all as specified and as directed. Make: HENSEL PART NO. DK 1600G/ SHENEIDER/RITTEL. |
| 38 | S & F in replacement PVC insulated and sheathed (ISI marked) stranded copper conductor 1.5 Sqmm size, 3 core round cable for street light connection from fitting connector to the terminal box including all fixing arrangement, complete all as specified and directed including taking down old wire. |
| 39 | M & L for street light bracket made out of GI pipe light grade 40 mm dia 1.2 metre length bent to shape and reduced to required size at top upto 1.5 metre length by cutting, welding and well finishing including MS clamp of flat iron of size 40x6 suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer including dismantling one complete all as specified and as directed. |
| 40 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with Stranded aluminium conductor of cross sectional area 10 sqmm 4.0 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. |
| 41 | Supply and laying pipe Galvanized light grade including fittings 80 mm dia complete all as specified and directed |
| 42 | M&L for Steel tubular swaged poles type 410 SP-31 (9.0 meters long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws, washers include drilling of holes, Painting (inside and outside) of steel tubular poles complete all as specified and directed. |
| 43 | M&L for PCC (1 : 2 : 4) type B2 (using 40 mm graded crushed stone aggregate) as in Copping of Steel pole complete all as specified and directed. |
| 44 | Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth wire 4 mm by means of bolt, nut, check nut and washer of galvanized iron or steel earthing lead to be protected by galvanized iron pipe of 40 mm bore light grade and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20 mm bore galvanized iron pipe medium grade for watering wire mess all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as directed. |
| 45 | Relaying of existing cable protection cover after cleaning at new location complete all as specified and directed |
| 46 | Supply and laying in trenches dry well burnt locally available sub class “B” bricks straight 225 mm x 115 mm x 65 mm over sand cushioning for protection of cable complete all as per specified and directed. Please Enable Macros to View BoQ information |
| 47 | Supply and laying in trenches dry well burnt locally available sub class “B” bricks straight 225 mm x 115 mm x 65 mm over sand cushioning for protection of cable complete all as per specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
TodayDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents
Download All (ZIP) ↓
Disclaimer