Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58375154

Tender For Provn Of Aluminium Window In Otm Accn Bldg No T-26, T-29 & P-41/1 And Roof Treatment In Bldg No P-29 Otm Accn Of Fd Regt And special Repair To Cook House Bldg No P-35 & P-36 Of Fd Regt At Dipatoli Mil Stn Under Ge Dipatoli

Issued by Statutory Bodies & Commissions/Committees · Ranchi, Jharkhand
Tender Value
40.56 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
21 days left
EMD
81120
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Aluminium Window In Otm Accn Bldg No T-26, T-29 & P-41/1 And Roof Treatment In Bldg No P-29 Otm Accn Of Fd Regt And special Repair To Cook House Bldg No P-35 & P-36 Of Fd Regt At Dipatoli Mil Stn Under Ge Dipatoli

BOQ

Name of Work:- PROVN OF ALUMINIUM WINDOW IN OTM ACCN BLDG NO T-26, T-29 & P-41/1 AND ROOF TREATMENT IN BLDG NO P-29 OTM ACCN OF FD REGT AND SPL REPAIR TO COOK HOUSE BLDG NO P-35 & P-36 OF FD REGT AT DIPATOLI MIL STN UNDER GE DIPATOLI
Sl. No. Item Description
1Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area n.exc 1.5 sqm each and removal from site including cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) complete all as specified.
2S&F anodised aluminium frame for doors, windows, ventiletors with one or more rebates including joining cleat for fixing etc complete all as specified incl. powder coating above aluminium section.(minimum thickness of powder coating 50 micron).complete all as specified & directed
3S&F for anodised window/ventilator shutters, side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,anodised aluminium snap beading screws,anodised aluminium fittings such as peg stays 150 mm long(1 no),hinges type-B-21 100 mm long( 2 no) suitable handle 1 no complete all as specified incl. powder coating of any colour (thick ness of powder coating not less than 50 micron).
4S & F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sq. M in each pane
5S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staples.complete all as specified and directed.
6Taking down/Dismantlinig wrought iron or mild steel work of any description not otherwise provided for.complete all as directed.
7S&F MS framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165 complete all as directed.
8Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
9M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement.complete all as specified and directed.
10M&L for preparing newly platered surfaces and applying two coat of distemper oil emulsion white or tinted on walls complete over one coat of primer including one coat of 2mm thick wall care putty on walls all as specified and directed
11M & L for PCC (1:3:6), type C-1 using 20mm graded stone aggregate as in filling of hold fast and similar work all as specified and directed.
12M & L for preparation of new steel surfaces over 10cm width or girth and priming with red oxide primer and painting with synthetic enamel painting two coats.complete all as specified and directed.
13Taking up or down steel tubing and connection of 15 mm bore complete all as directed at site
14S&F GI steel tubing for 15 mm bore and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc complete all as directed at site all as specified & directed.
15Refixing old 15mm GI tubing and connections concealed in new or old position (including cutting chasing and making good) (walls, ceilling, floor etc) complete all as specified and directed.
16Taking up or down steel tubing and connection of 20 mm bore complete all as directed at site
17S&F steel tubing for 20 mm bore and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc complete all as directed at site all as specified & directed
18All as above item No 17 but for refixing only.
19Taking up or down steel tubing and connection of 25 mm bore complete all as directed at site
20S&F steel tubing for 25 mm bore and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc complete all as directed at site all as specified & directed
21All as above item No 20 but for refixing only.
22M&L for roof treatment over in-accessible roofs in repair by complete removal of existing old treatment and treated with following specifications:(a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab.(b) 15 mm thick cement plaster fair finished using cement mortar (1:4) with WPC (as per manufacturer instruction) on roof slab.(c) Applying oil based bitumen primer @ 0.30 ltr/Sqm on plastered surface.(d) Applying modified APP polymeric membrane 3mm thick and minimum weight 3.00 Kg / Sqm for water proofing of roof , sealing as directed at site with 100 mm over laps as per manufacturer's instruction.(e) Applying two coat of aluminium paint over bituminous surface of membrane. complete all as specified and directedNote:- WPC shall be measured and paid separately.
23Supply only integral water proofing compound. ISI Marked
24M&L for repair and rendering 10mm thick in cm 1:3 on chajjas not exceeding 60cm width after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scaffolding work for double/single storey bldgs all as directed.
25M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of primer on wall of any height of bldgs all as specified and directed.
26Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately exc 500 But not exc 1000 ltrs Capacity) complete all as directed at site all as specified & directed
27S & F in repair 20 mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as directed at site all as specified & directed
28Demolition of reinforced concrete of any Description and in any Position not otherwise Specially provided for&(Reinforcement cut as required to facilitate demolition) complete all as specified and directed.(RCC Water Tank)
29S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank double layered ISI marked (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed.complete all as directed at site all as specified & directed
30Taking down cement plaster on wall, ceiling, chajjas, roof projections, lintel, etc of any description including raking out joints, hacking for key and scrubbing down with water etc and disposing off the rubbish materials out side MD land complete all as specified and directed.
31M&L for 20 mm thick rendering in cement mortar (1:4) on fair faces of brick work in two layers (10mm each coat) mixed with water proofing compound in top layer 200 ml per bag of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'.
32M&L for rendering 15 mm thick in cement Mortar (1:6) on the surfaces other than fair faces of brick work/concrete/ and finished the surface surface even and smmoth complete as specified and directed
33M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed.
34M&L for rendering 5mm thick in cement mortar 1:3 on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified and directed.
35M&L for preparation of newly / old plastered surfaces of wall and applying a coat of wall care putty 1 mm thick to make the surfaces truly smooth complete all as specified & directed
36M&L for applying two coats of distemper oil emulsion over a coat of primer white or tinted on new wall surfaces (or necessary preparation if required ) complete all as specified and directed.
37Complete removal of existing treatment of old plastered surfaces of walls and applying two coats acrylic based distemper over a coat of primer over with 1 mm putty finished surfaces of wall including preparation as per the manufacturer's instructions complete all as specified and directed
38M&L for complete removal of existing treatment of old plastered surfaces of walls and finishing the walls with Acrylic smooth exterior anti-fungal paint of required shade as approved by GE over including preparation complete all as specified and directed.
39M&L for preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified and directed.
40M&L for preparartion of old surfaces of ceiling & applying two coat of white washing complete all as specified and directed.
41Demolition of brick work built in cement mortar of any description complete all as directed.
42M&L for brickwork with flyash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
43M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
44Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed
45M&L for coloured non skid cermic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed in CM 1:6.complete all as directed.
46M&L for coloured glazed ceramic tiles in vertical surface 300x 450x 7 mm (any suitable size available in market) over 10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces all as specified and directed
47M&L for machine cut kota stone slab flooring 18-20mm thick, laid over 20mm thick cement screed base in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including rounding the exposed edges of kota stone complete all as specified and directed.
48All as per item No 48 here in before but as in skirting but on 15 mm thick rendering/ backing coat in CM (1:3) complete all as specified and directed.
49Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in cement mortar complete all as directed.
50M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement plaster (1:3) including rounding the exposed edges of granite complete all as specified and directed.
51Dismantling/Demolition /striping out of existing roof treatment (terfelt and roof plaster etc) including PCC padding of any discription and any thikness including backing and removal the debris complite all as directed.
52M&L for water proofing treatment to RCC roof slab including parapet comprising of the following course of tretment/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surface of roof including parpet surfaces. (b) Over the priming coat laying one layer APP based polymeric membrane of 3mm thick and minium weight not less than 3Kg/Sqm with non woven polyster fabric weight not less than 160 gms per sqm. Polymeric membrane shall be taken to a height of 60cm (mim) and than inserted th groove of parapet wall and shall be finished a membrance flashing (c) Application of two coats of Bituminous aluminum paints over the polymeric memnrance after necessary preparation and cleaning, Note :- Laying APP based polymeric membranceshall be done by tourch on mathod or as per manufacture insturction. (ii) A minimum overlap of 100 mm shall be made at the end 75mm shall be made at the side and sealed overlaped and joint as per manufacture instructions. (Note: Roof Treatment shall be carried out by manufacture's authorised against)
53M&L for 10mm thick screedd bed or bedding layeres in cement mortar (1:4) in order to maintain proper slope over existing roof surface for applying single component acrylic polymner modified, fininshed even and smooth without using extra cement mixed with water proofing compound complete all specified and as directed. Note :- Polymeric membrane and WPC shall be measured and paid spearately under relevant items of this Sch 'A'.
54M&L for 25mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) mixed with water proofing compound and laid on RCC slab as base layer for roof tratment treatment on RCC surface of concrete by using broom stick while the cocrete is green complete all as specified & directed. Note:- WPC shall be measured & paid separatly.
55S&F Powder coated aluminium window sliding type three track (2 glazed & one gauzed shutter) aluminium sections weighing not less than 1.25kg/m for frame and 0.45 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing, screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window with guard bars and making good disturbed surfaces of wall complete all as specified and directed.
56S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator with guard bars and making good disturbed surfaces of wall complete all as specified and directed.
57Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm but n exc 4 sqm each and removal from site including cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) complete all as specified.
58S&F pressed steel frames of size 125x60 mm with thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs, hinges, lock strike plate, etc. including one soap coat of priming complete all as specified and directed.
59S&F pressed steel frames of size 105x60 mm for doors with one or more rebates including supply and fixing necessary lugs, hinges, lock strike plate, etc. including one soap coat of priming complete all as specified and directed..
60S&F 35 mm thick flush shutter factory made, solid core construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed.
61S& F in repair Prelaminated particle board 18/19mm thick, exterior grade, prelaminated one side with decorative choice lasmination & other side balancing white lamination in pelmet boxes,cup board shutters etc, rebated or flat edged fixed in repairs complete all as specified as directed.
62S&F second class hardwood, factory made glazed and skelton shutters 35 mm thick open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I Section8, Clause 8.24 (a) supplied and fitted to chowkats. all as specified & directed
63M&L for plain fillets. square, rectangular or triangular in section, exc 6 Sq.cm but n.exc 25 Sq.cm clean sawn, secured with nails or brads.all as specified & directed
64S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing on SI page No 156 of SSR Part-II complete all as specified & directed
65S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing on SI page No.160 of SSR Part-II completed complete all as specified and directed.
66M&L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
67M&L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
68S&F 75 mm size butt hinges medium weight cold rolled milled steel all as specified & directed
69S&F 140 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
70S&F aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified and directed.
71S&F aluminium handles 150mm size cast type anodised complete all as specified and directed.
72S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all specified and directed.
73S&F 150 mm long Aluminium anodised barrel tower bolts complete all as specified and directed.
74S&F aluminium handles 125 mm size cast type anodised complete all as specified and directed.
75S&F MS 300mm, ordinary rat towel rod pattern springs including roller and roller plate complete complete all as specified and directed.
76Demolition of cement concrete (un-reinforced) any description and in any position not otherwise specifically provided for complete all as directed.
77M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) 25 mm thick (average) stone aggregate as in sub base, levelling course to receive floor topping complete all as specified and directed.
78M&L for 75 mm thick PCC 1:3:6 Type C-2 using 20mm graded stone aggregate as in plinth protection etc, laid to slope of 1:12 and shall be laid in alternate bays n.exc 1.5 m in length, joints 20mm wide will be provided every 1.5m and filled with ceiling compound grade ‘A’ the joints between external wall and plinth protection shall also be laid with ceiling compound grade ’A’, finished cement concrete surface even and smooth all as specified & directed
79M&L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel or drain including use of necessary from work for fair finished surface complete all as specified and directed.
80S&F in repairs beveled edge mirror of size 600 x 450 mm, mounted on 6 mm thick AC plain building board or PVC board and fixed to wall on wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
81S&F in repair 10 ltr capacity dual type PVC flushing cistern low level white colour including PVC connection, PVC flush pipe of required length complete all as specified and directed.
82S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests with suitable size PVC 'P' or 'S' trap including provision of cement concrete bedding complete all as specified and directed.
83S&F in repair 15 mm bore pillar tap fancy type cast copper alloy with capstin head CP Screwed down high pressure with or without littered H or C with long Screwed Shank and fly nuts Screwed for Iron pipe etc complete all as specified and directed.
84S&F in repairs Bib taps fancy type, brass chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule complete all as specified and directed.
85S&F for corner glass shelf 225x 225mm with CP steel frame complete all as specified and directed, complete all as specified and directed.
86S&F 15mm bore PVC Connection with PTMT nut of length 600 mm complete all as specified and directed.
87S&F in repair brass chromium plated angle/stop cock, of 15 mm bore complete all as specified and directed.
88S&F brass chromium plated tubular towel rail, 20mm dia and 0.80mm thick, D type, 60cm long between flanges complete all as specified and directed.
89S&F in repair for 75 mm bore PVC (SWR) floor trap, plain with CP grating (with or without hole) including jointing with solvent cement complete all as specified and directed.
90Taking down CI/PVC/AC soil pipe including fittings from wall, treches of any description complete all as directed.
91S&F in repair 110mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed.
92S&F in repair 110mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints fixed to wall complete all as specified and directed.
93S&F in repair110mm bore PVC bends of any radius complete all as specified and directed.
94S&F in repair 110mm bore PVC (SWR) branch piece double (double 'Y') equal or unequal complete all as specified and directed.
95S&F in repair 110mm bore PVC (SWR) junction double (double 'T') equal or unequal complete all as specified and directed.
96S&F in repair 110mm bore PVC SWR vent cowl complete all as specified and directed.
97S&F in repair 75mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed.
98S&F in repair 75mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints fixed to wall complete all as specified and directed.
99S&F in repair 75 mm bore PVC (SWR) bends of any radius with acess door complete all as specified and directed.
100S&F in repair 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal complete all as specified and directed.
101S&F in repair 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal complete all as specified and directed.
102S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
103S& in repair vitreous China Urinal, Half stall type, white (including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
104S&F urinal spreader of CP brass for fixing with 15 mm dia pipe complete all as specified and directed.
105Dismantalling of existing water tanks and removinging and S&F in repairs 500 ltr capacity Rotational moulded polyethylene water storage tank double layered ISI marked (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed.complete all as directed
106Dismantalling of existing water tanks and removinging to store and S&F in repairs 1000 ltr capacity Rotational moulded polyethylene water storage tank double layered ISI marked (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed.complete all as directed.
107S&F in repair 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and dierected.
108M&L for cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified & directed
109Removing building materials and debris (other than excavated earth) to a distance of 5 KM inside MD Land at locations specified including loading and dumping/ leveling at the destination complete all as directed.
110M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
111M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
112M&L 75 mm thick cement concrete in foundations/sub base of floor in cement morter (1:4:8) type D-2 using 40mm graded stone aggregate complete all as specified and as directed by Engr-in-Charge.
113M&L Examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder upto 5 -10 mm depth without damaging existing rebars, carefully removing unsound weak/ loose concrete/ cover & concrete around the rebars upto 10 mm depth by low impact high frequency hammer/ chipper without damaging the sound concrete, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, disposing off the debris so generated on weekly basis outside the premises, etc, complete all as specified and directed necessary scaff -folding complete all as specified and directed
114M&L for cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and applying two coats of alkaline rust converting primer Sika RustOff 100 or ReArm Rust Remover with brush on the existing rebar for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days including surface preparation. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, complete all as specified and as directed by Engr-in-charge Note: Work to be executed by the authorised applicator of manufacturer only.
115M&L for 15mm thick plaster on Sikawrap230c covered surface in cement mortar 1:4 mixed with approved integral waterproofing compound as per manufacturer’s instructions complete all as specified and as directed
116M&L for coloured glazed chequered cement concrete tiles with grey cement and no pigment 30cmx30cmx25mm thick over 15mm thick screed bed in CM 1:6 set jointed and pointed in neat cement slurry in floors complete all as specified and as directed by Engr-in-Charge.
117Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
118M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size not less than 25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box and suitable size modular plate for fitting switch, socket etc complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
119One light point controlled by one, one way switch 5 Amps
120One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
121One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
122One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
123Description all as per item No 118 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH, PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH, PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
124S & F for modular Switch flush type single pole 5/6 amp, one way single module 230 Volts complete all as specified and directed at site.
125S & F for modular Switch flush type single pole 15/16 amp, 230 Volts complete all as specified and directed at site.
126S & F for modular socket outlet 2/3 pin, 5/6 Amp (2 module) 230 Volts complete all as specified and directed at site.
127S & F for modular socket outlet 2/3 pin, 06/16 Amp (2 module) 230 Volts complete all as specified and directed at site.
128S & F for Ceiling rose, surface Bakelite with 3 terminals PVC ISI marked for batten fitting complete all as specified
129Supply and fix in replacement Polycarbonate Modular AC Box with 20 to 32Amps Single Pole MCB, enclosure and Heavy Duty ISI Plug Top (White) with indicator and connecting complete all as specified and directed.
130S & F in replacement wall mounted Industrial grade LED tube light fitting 20 Watts batten for surface mounted, anodized extruded aluminium housing, high tranmissitvity diffuser, luminous efficacy not less than 120 lumen/watt,THD <10% , Glare Free, natural white, power factor greater than 0.95, Color Temp 6500K(Cool white), CRI 80, In-built surge protection of 4 KVA, 230 volts complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 mm from ceiling rose to fitting complete all as specified and as directed.
131S & F in replacement for Industrial grade Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP66 & IK07 for security light fitting luminaire (120 lm/watt), with toughened glass, CRI>80, Power Factor >0.95 with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
132S & F for energy efficient exhaust fan Copper winding of 380 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection & body earth connection with ceiling rose and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed including taking down old exhaust fan and deposited old unsv exhaust fan to MES store yard of AGE E/M Dipatoli
133S & F in replacement MCCB DB VTPN 4 way 250A rated with metal double door, IP:43 protection, Isolated neutral bar, Insulated busbar assembly, Door earthing, Mechanical impact strength IK 09 suitable for upto 160A 4P MCCB as I/C (Frame 2) and suitable for MCBs as outgoing including grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
134S & F in replacement for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with push/slide locking system including filling any blank slot with blanking plates & necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
135Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed.
136S & F in replacement MCB TP 40 to 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
137S & F in replacement MCB SPN 40 to 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
138S & F in replacement MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
139M & L in replacement for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
140S&F Geyser 25 Litres with inner tank and heating element 2KW capacity, BEE 5 Star rated, PUF insulation, outer body made of rutst proof ABS and plastic end cover complete with all accessories such as safety valve, themostate, NRV, connection piece, anchor bolts etc incl record serial No, Make and marking MES No (As given by MES), complete all as per specified and as directed by Engineer-in-charge. (Note- Manufacturer shall provide warranty of inner tank for minimum 7 years and warrantee for heating element for minimum 3 years) including taking down & depositing old one to AGE E/M dipatoli store. S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58375154
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.56 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Aluminium Window In Otm Accn Bldg No T-26, T-29 & P-41/1 And Roof Treatment In Bldg No P-29 Otm Accn Of Fd Regt And special Repair To Cook House Bldg No P-35 & P-36 Of Fd Regt At Dipatoli Mil Stn Under Ge Dipatoli
Basic Detail
Tender No 8000/2245/E8
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 04 Nov 2026
Submission Date 25 Nov 2026
Open Date 02 Dec 2026
Finance
Tender Value 40.56 Lakhs
Tender Fee 500
EMD 81120
Exemption Available
Document List
75cad87b-d7b1-43ea-844a-caa90fc88b35.html
BOQ_894255.xls
TENDER2245.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

75cad87b-d7b1-43ea-844a-caa90fc88b35.html

xls

BOQ_894255.xls

pdf

TENDER2245.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender