Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58375137

Tender For Repair/Replacement Of Earthing Of Lt Panel Boards And Lt Switch Gear And Connected Work At Mes Md Accn And Basra Area, Repair/Replacement Of Chemical And Copper Earthing And Connected Work At Technical Area, Repair Replacement Of Distribut

Issued by Statutory Bodies & Commissions/Committees · Jalpaiguri, West Bengal
Tender Value
35.50 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
21 days left
EMD
71000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Earthing Of Lt Panel Boards And Lt Switch Gear And Connected Work At Mes Md Accn And Basra Area, Repair/Replacement Of Chemical And Copper Earthing And Connected Work At Technical Area, Repair Replacement Of Distribution Pipe Line In In-Living Area, Officer Mess, Mes And Nces Md Accn Area And Repair/Maintenance Of Solar Water Heater And Other Connected Works At Af Stn Hasimara

BOQ

Name of Work:- REPAIR/REPLACEMENT OF EARTHING OF LT PANEL BOARDS AND LT SWITCH GEAR AND CONNECTED WORK AT MES MD ACCN AND BASRA AREA, REPAIR/REPLACEMENT OF CHEMICAL AND COPPER EARTHING AND CONNECTED WORK AT TECHNICAL AREA, REPAIR REPLACEMENT OF DISTRIBUTION PIPE LINE IN IN-LIVING AREA, OFFICER MESS, MES AND NCES MD ACCN AREA AND REPAIR/MAINTENANCE OF SOLAR WATER HEATER AND OTHER CONNECTED WORKS AT AF STN HASIMARA
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : REPAIR/REPLACEMENT OF EARTHING OF LT PANEL BOARDS AND LT SWITCH GEAR AND CONNECTED WORK AT MES MD ACCN AND BASRA AREA, REPAIR/REPLACEMENT OF CHEMICAL AND COPPER EARTHING AND CONNECTED WORK AT TECHNICAL AREA, REPAIR REPLACEMENT OF DISTRIBUTION PIPE LINE IN IN-LIVING AREA, OFFICER MESS, MES AND NCE’S MD ACCN AREA AND REPAIR/MAINTENANCE OF SOLAR WATER HEATER AND OTHER CONNECTED WORKS AT AF STN HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2M&L for earthing of machinery/equipment installed at power house/Sub Stn/ DB complete with galvanised steel earth plate electrode 60 × 60cm × 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including galvanised earth lead wire 4.0mm, 15mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion including taking out/dismantling of old unserviceable earthing of any description, complete all as specified and as directed.Note :- (i) Earth lead wire/strip beyond 7.5 mtr shall be measured and paid separately.(ii) On testing, after completion, if the earth resistance <2 ohms is not obtained, earthing shall be regenerated at no extra cost till the desired earth resistance is obtained. (iii) locally available best quality soil to beused all around the earth plate electrode (along periphery of solt, charcole, chemical etc) min covered vol 450 x 450 x 450mm included in unit quoted rate.
3All as per item No 1.00 here-in- before but using GI earth strip of size 32 x 6mm as earth lead and 40mm boe (medium grade) galvanized iron pipe for protection of earth lead, complete all as specified and directed.
4M&L for earthing of equipment at power house/Sub Stn/DB complete with copper earth plate electrode 60 × 60cm × 3.00mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel in any type of soil, connected to earthing test point and and necessary excavation and earth work, PCC (1:2:6) type C-1 as earth pit with pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 100mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including Copper earth strip 20 x 3.00mm, protected by 40mm bore (medium grade) galvanized iron pipe up to earthing test point including disposal of soil to a distance not exc 50 mtr and necessary testing on completion, complete all as specified and directed.Note:- (i) Proper earthing pit should be provided with pit cover.(ii) On testing, after completion, if the earth resistance <2 ohms is not obtained, earthing shall be regenerated at no extra cost till the desired earth resistance is obtained. (iii) locally available best quality soil to beused all around the earth plate electrode (along periphery of solt, charcole, chemical etc) min covered vol 450 x 450 x 450mm included in unit quoted rate.
5All as per item No 3.00 here-in before but using magnesium-sulphate in lieu of common solt, complete all as specified and as directed.
6All as per item No 3.00 here-in before but using copper-sulphate in lieu of common solt, complete all as specified and as directed.
7S&F in replacement 32 x 6mm Gl strip in short pieces on surface or in recess for inter connecting, complete all as specified and directed.
8All as per item No 6.00 here-in before but copper strip 20 x 3.00mm, complete all as specified and as directed.
9All as per item No 6.00 here-in before but copper strip 32 x 6.00mm, complete all as specified and as directed.
10All as per item No 6.00 here-in before but galvanised wire 4mm dia, complete all as specified and as directed.
11All as per item No 6.00 here-in before but aluminuium strip 25 x 3mm, complete all as specified and as directed
12S&F in repair porcelain vitreous white/brown/green spacers insulator of size 75mm x 35mm x 40mm height complete with one number galvanized iron stud bolts 6mm dia x 40mm long including nut & washers and two number galvanized iron fixing bolts of size 6mm dia and 50mm long including washers and drilling holes for holding/foxing aluminium strip/roof conductor, as required, including taking down the broken insulator, complete all as specified and directed.
13M &L for eathing pit in PCC (1:3:6) type C1 pre-cast RCC (1:2:4) type B-1 cover slab of size 300 x 300 x 50mm reinforced with 8mm dia TMT steel bars @ 15 cm center to center in both direction and 10mm dia MS handle of suitable size including 29 mm bore GI light grade pipe for watering, funnel, wire mesh, necessary earth work in soft / loose soil all as shown in Electrical plate No 4 of MES schedule Part -I (2009) and testing and applying three coats of white wash on exposed surface of concrete complete including taking down old one, complete all as specified and directed.
14Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
15M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles, blocks for mounting air termination rod including formwork (as required), complete all as specified and directed.
16Physical inspection of earthing to check the healthiness of earthing system whether the resistance is under safe limit of resistance or not, If higher than the permissible limit, then recharging of earthing should be done immediately with carbon based low resistivity compound of 0.001 Ohm meter, recharging of existing earth pit by excavating soil up to electrode depth, approx 10 feet by manual drilling (post hole) method and filling with backfill compound / maintenance free earthing compound to achieve desired resistance value less than 1 Ohms in and including watering up to top of the excavated bore, backfilling of earth pit, measuring the value after refilling pit and testing of earth resistance after recharging, reconnecting, grounding electrode conductor and earth grid, applying petroleum jelly etc. to bolted joints to minimize corrosion for the pipe earthing or plate earthing then gel should be used to lower down the resistance, complete all as specified and as directed.Note: (i) In case of satisfactory results not achieved or results degrade during one year of recharging of the earthing, the same shall be made good/recharged again in order to have required test results within the defect liability period, without any extra cost to the department.(ii) Necessary compound required for recharging shall be measured and paid separately as 'Supply only'.
17Supply only carbon based low resistivity compound 0.001 ohm meter, backfill compound, complete all as specified and directed.
18M & L for brazing of copper strip including removing of nut, bolt, washer, etc and connecting with equipment directly from earthing, complete all as specified and directed.
19S&F polymer earth housing pit manufactured from heavy duty polypropylene material with sign board, triangular shape, making connection of earth strip including minor adjustment including dismantling of old existing PCC earth pit with cover, complete all as specified and directed.
20Supply & Installation of advance encapsulated compound based CPRI tested maintenance free, pipe-in- pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100) microns with pure Zinc(99.9%) & alloy coating (200- 250)microns. Earthing System confirming IS 3043.The outer and inner pipe should be 76.2mm & 41.9mm dia, 3mtrs Length, Zinc coated with additional special alloy coating 300mm on the topside for additional protection of the Terminal. The annular space between the pipes being filled up with compact filled (Crystalline on the topside for additional protection of the Terminal. The annular space between the pipes being filled up with compact filled (Crystalline Conductive |Compound). The compact filled mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, The job includes digging the pits and refilling the same by baron corrodes. The inner pipe should be extended with terminals for connectivity, The job includes digging the pits and refilling the same by baron Conduct lite Back Fill Earth Enhancing Carbon Based Conductive Concrete compound, The Back Fill Compound should be Electronically Conductive with Noncorrosive Properties & Environmentally Neutral Material. Conduct lite Back Fill Compound shall be suitable to be installed in either slurry or dry form and shall not be mixed with any soil / cement etc while pouring in the bore hole, So that it improves conductivity of the earth electrode and ground contact area. conduct lite BFC 25kgs a bag and installation of following components, complete all as specified and directed.INSTALLATION:(a) Installation in black cotton or garden soil-1/2 Bag with 2m Electrode & 2/3 Bag with 3m Electrode.(b) Installation in Harsh - Rocky/Sandy Soil Condition - For installation of 2 M Earth Electrode Electrode with 2 to 4 bags BFC) & for 3 M Earth Electrode (3 to 5 bags BFC) depending on soil condition to be mixed with Soil & additional electrodes to be installed & interconnected for lowering soil resistivity in excavated pit.(c) The buried Conductors (GI/Copper/Aluminium) are to be covered by 50mm thick layer of conduct lite for additional protection of conductors & better conductivity to lower the resistivity of soil & bring down earth resistance. Note : Earth result after installation completely should be less than 1 Ohm.
21M & L test point terminal block made of gun metal or phosphorusbronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screw including fixing into MS box 2mm thick, complete all as specified and directed.
22M & L for painting of earthing pit through synthetic enamel paint (Approved colour) over a coat of primer including cleaning of earth chamber area (1m x 1m), cleaning of all rusted joints, complete all as specified and directed.
23S&F 20mm bore GI pipe, light grade, with necessary fittings such as bend, tee, elbow etc for mounting of air termination spike including taking down old unserviceable pipe, complete all as specified and directed.
24Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm outer dia conforming to IS, approved colour, complete with fittings for cable protection, complete allas specified and directed.
25Horizontal boring under the road below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work complete all as specified and directed
26Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole/stay or laying pipes etc and getting out in soft/loose soil, complete all as specified and directed.
27Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
28Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
29Cutting of bituminous road/hardstanding/path/plinth protection etc for laying of pipe line n. exc. 90cm below GL, getting out and disposal of materials to a distance n. exc. 50m from the site of work, complete all as specified and directed.
30M & L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) for making good to disturbed surfaces of road/hardstanding etc, complete all as specified and directed.
31Supply and laying or fixing, three layer (inner antimicrobial & outer UV stabilized), polyprolene random pipe 90mm outer dia, PP-R pipes SDR 7.4 (PN-16) confirming to IS -15801 : 2008, UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including PP-R plain & brass threaded polypropylene random fittings fixed complete to trenches/wall/cellings or laying in floor including taking down old unserviceable PPR/GI pipes, complete all as specified and directed.
32All as per item No 30.00 here-in before but 63mm outer dia, complete all as specified and as directed
33All as per item No 30.00 here-in before but 50mm outer dia, complete all as specified and as directed
34All as per item No 30.00 here-in before but 32mm outer dia, complete all as specified and as directed
35All as per item No 30.00 here-in before but 25mm outer dia, complete all as specified and as directed
36S&F CPVC pipe of size 50mm outer dia in trenches, high pressure, CPVC pipes, schedule 11 & plain CPVC schedule 11 fittings, including all necessary fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc. and with CPVC solvents cement including taking down old unserviceable pipes, complete all as specified and directed.
37All as per item No 35.00 here-in before but 40mm outer dia, complete all as specified and as directed
38S&F in repair 32mm dia PP-R gate valve (brass insert) confirming to IS -15801 : 2008, complete all as specified and directed.
39S&F in repair 50mm dia PP-R gate valve (brass insert) confirming to IS -15801 : 2008, complete all as specified and directed.
40S&F in repair 63mm dia PP-R gate valve (brass insert) confirming to IS -15801 : 2008, complete all as specified and directed.
41Making connection of PP-R distribution branch with PP-R main/GI main of size 50 to 90mm outer dia by providing and fixing Tee including cutting and making fusion joint etc, complete all as specified and directed.
42Making connection of PP-R distribution branch with PP-R main/GI main of size 20 to 40mm outer dia by providing and fixing Tee including cutting and making fusion joint etc, complete all as specified and directed.
43S&F 50mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed.
44S&F 40mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed.
45S&F 25mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed.
46S&F 20mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed.
47S&F in repair 32mm PP-R tank connector (OST) and make hole in tank as per required size including taking down old unsrviceble connector, complete all as specified and directed.
48S&F in repair three layer PP-R elbow 90/45 degree (UV stabilized) confirming to IS -15801 : 2008, for 90mm dia PP-R pipes, complete all as specified and directed.
49All as per item No. 47.00 here-in before but 63mm dia, complete all as specified and directed.
50All as per item No. 47.00 here-in before but 50mm dia, complete all as specified and directed.
51All as per item No. 47.00 here-in before but 32mm dia, complete all as specified and directed.
52All as per item No. 47.00 here-in before but 25mm dia, complete all as specified and directed.
53S&F in repair three layer PP-R union 63mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed.
54All as per item No. 52.00 here-in before but 50mm dia, complete all as specified and directed.
55All as per item No. 52.00 here-in before but 32mm dia, complete all as specified and directed.
56All as per item No. 52.00 here-in before but 25mm dia, complete all as specified and directed.
57S&F in repair three layer PP-R socket 90mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed.
58All as per item No. 56.00 here-in before but 63mm dia, complete all as specified and directed.
59All as per item No. 56.00 here-in before but 32mm dia, complete all as specified and directed.
60All as per item No. 56.00 here-in before but 25mm dia, complete all as specified and directed.
61S&F in repair three layer PP-R flange (core), 90mm dia (UV stabilized) confirming to IS -15801 : 2008 for PP-R pipes, complete all as specified and directed.
62S&F in repair three layer PP-R flange ring, 90mm dia (UV stabilized) confirming to IS -15801 : 2008 for PP-R pipes, complete all as specified and directed.
63Cutting existing steel tubing of size 40/50mm for alterations or additions (each cut measured), complete all as specified and directed.
64Screwing existing steel tubing of size 40/ 50mm for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and directed.
65S&F 50mm dia CPVC ball valve suitable for CPVC pipe and taking down old unserviceble vall valve, complete all as specified and directed.
66S&F 25mm dia CPVC ball valve suitable for CPVC pipe and taking down old unserviceble vall valve, complete all as specified and directed.
67Taking up or down steel tubing and connections, of size 25mm bore including cleaning and refixing in new or old position (walls, ceiling, floors etc) including connection and testing, complete all as specified and directed.
68Taking up or down steel tubing and connections, of size 15mm bore including cleaning and refixing in new or old position (walls, ceiling, floors etc) including connection and testing, complete all as specified and directed.
69S&F 25mm bore GI water tubing and connection, medium grade, with all fitting fixed to wall or in ceiling or laid in floors, complete all as specified and directed.
70S&F 15mm bore GI water tubing and connection, medium grade, with all fitting fixed to wall or in ceiling or laid in floors, complete all as specified and directed.
71Re-fixing old steel tubing and connection 25mm bore in new or old position complete on wall/ceiling, complete all as specified and directed.(Note: Serviceable steel tubing obtained from taking down shall be re-used.)
72Re-fixing old steel tubing and connection 15mm bore in new or old position complete on wall/ceiling, complete all as specified and directed.(Note: Serviceable steel tubing obtained from taking down shall be re-used.)
73M & L for construction of valves pit chamber of size 900mm x 900mm x 900mm (internal), 15cm thick PCC foundation using PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), 25cm thick brick wall, using old size burnt clay brick in CM (1:4), 15mm thick rendering on internal and extranal surfaces both in CM (1:4), PCC (1:2:4) type B1 coping (using 20mm graded crushed stone aggregate) for grouting MS frame including foundation 3mm thick MS top sheet cover with locking arrangement including 50mm pad lock with double key arrangement, MS frame work made out of 40 x 40 x 5mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer incuding necessary excavation in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs, complete all as specified and directed.
74S&F in replacement, solar plate made out of toughened glass of size 200cm x 115cm, thickness 6mm as per existing model, complete all as specified and directed.
75S&F in replacement, solar water heater assembly inbuilt fitted with heating element as existing model and type upto 3000 Watt, complete all as specified and directed.
76S&F in replacement, thermostat suitable for 3000 Watt heating element as existing model and type, complete all as specified and directed.
77S&F in repair 25mm air release brass ball valve high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed as per existing model suitable for solar water heater, complete all as specified and directed.
78Servicing of solar water heater capacity upto 200 LPD, washing/cleaning of toughened glass, checking and repairing of internal & external leakage (copper tubes, pipes tank & panels, tray) ,tightened of loose wire connections, draining out collectors and pipes and pass through pipes out anti-rusting solution, hard water scales deposit descaled through acid, cleaning of storage water tank (steel& PVC), make up tank including dismantling inlet and outlet connection and re-fixing the same after cleaning for proper functioning to maintain enough water temp, complete alt as specified and directed. Note : (i) Climbing upto 2nd floor for servicing shall deemed to be includung in the unit quoted rate. (ii) Necessary minor items such as tee, elbow, nipple, union, etc shall be included in the unit quoted rate by the contractor.(iii) Major parts such as solar water heater assembly, thermostat etc shall be measured and paid seperately as 'Supply only'.
79Supply only, solar water heater assembly inbuilt fitted with heating element as existing model and type upto 3000 Watt, complete all as specified and directed.
80Supply only, thermostat suitable for 3000 Watt heating element as existing model and type, complete all as specified and directed.
81S&F repair steel inner tank of capacity upto 200 Ltr after removal from solar heater and further disconnecting off aluminum foil, glass wool and re-assembling the same after repair and re fixing in position, complete all as specified and directed.
82S&F rotational moulded polyethylene (HDPE) water storage tanks, (made 100% virgin and food grade plastic), triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1996, hoisted and fixed in position all as specified in SSR Part I (250 ltr capacity) including 20mm Nipple suitable for HDPE water tank and 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old unserviceable water tank of any capacity, complete all as specified and directed.
83S&F in repair 15mm bore, bib tap, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
84S&F in replacement heavy duty rubber hose pipe 50mm dia 3mm thick, 1.2m long suitable for solar water heater, complete all as specified and directed
85S&F in repair rigid non metallic PVC conduit 20mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and complete with all fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete alt as specified and directed.
86Note: An amount of Rs.68,199.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58375137
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35.50 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Earthing Of Lt Panel Boards And Lt Switch Gear And Connected Work At Mes Md Accn And Basra Area, Repair/Replacement Of Chemical And Copper Earthing And Connected Work At Technical Area, Repair Replacement Of Distribution Pipe Line In In-Living Area, Officer Mess, Mes And Nces Md Accn Area And Repair/Maintenance Of Solar Water Heater And Other Connected Works At Af Stn Hasimara
Basic Detail
Tender No C/8999/2026-27/E8
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 04 Nov 2026
Submission Date 25 Nov 2026
Open Date 02 Dec 2026
Finance
Tender Value 35.50 Lakhs
Tender Fee 500
EMD 71000
Exemption Available
Document List
069a881b-ce68-4848-b199-2fa1474da067.html
BOQ_894371.xls
Tender8999.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

069a881b-ce68-4848-b199-2fa1474da067.html

xls

BOQ_894371.xls

pdf

Tender8999.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender