Tender For Provision For Erection Of 250Kva Dg, Ltug Cable & Power Main Arrangements To The Ct Scan & X-Ray In Government Dharmapuri Medical College & Hospital At Dharmapuri In Dharmapuri District.
Tender Value
10 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
9 days left
EMD
10000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dharmapuri → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision For Erection Of 250Kva Dg, Ltug Cable & Power Main Arrangements To The Ct Scan & X-Ray In Government Dharmapuri Medical College & Hospital At Dharmapuri In Dharmapuri District.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Erection of 400A capacity dust and vermin proof cubical panel board made up of 16 SWG CRCA sheet steel enclosure with supply and fixing of the following interior mounting fuse switch with HRC fuses arrangement in two rows with a central bus bar chamber and two cable chambers at the top and bottom conforming to IE rules400A TPN SDF switch disconnector fuse units in sheet steel Enclosure with HRC Fuse Double Break Switch -1 No 315A TPN SDF switch disconnector fuse units in sheet steel Enclosure with HRC Fuse Double Break Switch - 2 Nos200A TPN SDF switch disconnector fuse units in sheet steel Enclosure with HRC Fuse Double Break Switch - 2 Nos , 100A TPN SDF Swicth disconnector fuse unit in sheet steel enclosure with HRC Fuse Double Break Swicth -1 No , 63A TPN SDF Swicth disconnector fuse unit in sheet steel enclosure with HRC Fuse Double break Swicth -1 No The bus bar chamber will consist of suitable size of tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE Rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partition, 3Nos 75x6mm tinned copper flats should be provided all round the panel for earth bus.The fuse Switches should be connected with the phase and natural buses with suitable size of rigid copper flat/rod and Each switch should be connected with 2 Nos earth bus with 2 runs of No.14 SWG rigid Tinned copper rod with suitable lugs. Phase and neutral tinned buses should be tinned properly. The panel should have a separate digital metering chamber at the top side consisting of voltage, current, PF, hormonics and CT arrangement, Pilot lamps, toggle switches, fuse units. The panel should be provided with two coats of Powder Coated paint of approved colour over one coat of zinc oxide primer, approved by the site officer and also the danger board. Superscription of incoming and outgoing feeding cable details, capacity of switches etc., with white paint and 2 nos metallic danger board to be affixed, providing Rubber Beading for All DoorsThe bus bar chamber should have 3 Nos of 75mm x 6mm tinned copper flat for 3 phases and 1 No 2\\" x 1/4\\" tinned copper flat for Neutral. The outgoing switches should be connected to the bus with the following copper flats. 1) 400A & 315A TPN switch with 75mm x 6mm tinned copper flat. 2) 200A TPN switch with 50mm x 6mm tinned copper flat. The capacity of the switches size of incoming and out going cable the place to which the supply is feed shall be mounted on switch chamber. The panel board should be mounted on 75mm x6mm MS channel provided all round at bottom of the panel. The whole arrangement should be erected on a masonry pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 0.75 m from the ground level with necessary earth connection. |
| 2 | Supply and Erection of 315A capacity dust and vermin proof cubical panel board made up of 16 SWG CRCA sheet steel enclosure with supply and fixing of the following interior mounting fuse switch with HRC fuses arrangement in two rows with a central bus bar chamber and two cable chambers at the top and bottom conforming to IE rules 315A TPN SDF switch disconnector fuse units in sheet steel Enclosure with HRC Fuse Double Break Switch - 1 No200A TPN SDF switch disconnector fuse units in sheet steel Enclosure with HRC Fuse Double Break Switch - 2 Nos125A TPN SDF switch disconnector fuse units in sheet steel Enclosure with HRC Fuse Double Break Switch - 2 Nos 100A TPN SDF switch disconnector fuse units in sheet steel Enclosure with HRC Fuse Double Break Switch - 2 Nos The bus bar chamber will consist of suitable size of tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE Rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partition, 3Nos 75x6mm tinned copper flats should be provided all round the panel for earth bus.The fuse Switches should be connected with the phase and natural buses with suitable size of rigid copper flat/rod and Each switch should be connected with 2 Nos earth bus with 2 runs of No.14 SWG rigid Tinned copper rod with suitable lugs. Phase and neutral tinned buses should be tinned properly.The panel should have a separate digital metering chamber at the top side consisting of voltage, current, PF, hormonics and CT arrangement, Pilot lamps, toggle switches, fuse units. The panel should be provided with two coats of Powder Coated paint of approved colour over one coat of zinc oxide primer, approved by the site officer and also the danger board. Superscription of incoming and outgoing feeding cable details, capacity of switches etc., with white paint and 2 nos metallic danger board to be affixed, providing Rubber Beading for All DoorsThe bus bar chamber should have 3 Nos of 75mm x 6mm tinned copper flat for 3 phases and 1 No 2\\" x 1/4\\" tinned copper flat for Neutral. The outgoing switches should be connected to the bus with the following copper flats. 1) 315A TPN switch with 75mm x 6mm tinned copper flat. 2) 200A TPN switch with 33mm x 6mm tinned copper flat. 3) 125A TPN & 100A TPN switch with 25mm x 6mm tinned copper flat. The capacity of the switches size of incoming and out going cable the place to which the supply is feed shall be mounted on switch chamber. The panel board should be mounted on 75mm x6mm MS channel provided all round at bottom of the panel. The whole arrangement should be erected on a masonry pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 0.75 m from the ground level with necessary earth connection. |
| 3 | Supply and fixing of 200A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with Earth connection only. |
| 4 | Supply and fixing of 100A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with Earth connection only. |
| 5 | Supply and laying of 3 ½ x 300 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75m putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. |
| 6 | Supply and clamping of 3½ x 300 sq.mm PVC LTUG armoured LTUG cable on post or wall with MS Clamps. |
| 7 | Supply and fixing of brass cable gland for 3½ x 300 sq.mm. PVC armoured LTUG cable with earth connection. |
| 8 | Supply and providing cable end termination of 3½ x 300 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. |
| 9 | Supply and clamping of 3½ x 240 sq.mm PVC LTUG armoured LTUG cable on post or wall with MS Clamps. |
| 10 | Supply and fixing of brass cable gland for 3½ x 240 sq.mm. PVC armoured LTUG cable with earth connection. |
| 11 | Supply and providing cable end termination of 3½ x 240 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. |
| 12 | Supply and clamping of 3½ x 150 sq.mm PVC LTUG armoured LTUG cable on post or wall with MS Clamps. |
| 13 | Supply and fixing of brass cable gland for 3½ x 150 sq.mm. PVC armoured LTUG cable with earth connection. |
| 14 | Supply and providing cable end termination of 3½ x 150 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. |
| 15 | Preparation of site plan physical layout, electrical line schematic diagram in 10 sets getting drawing approval from CEIG, preparation of completion report, rectification report and arranging CEIG inspection and obtaining safety certificate preparation of 1 set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in Generator room and payment of CEIG inspection fees. |
| 16 | Supply and fixing of Cable Route Indicator for LT Cable. |
| 17 | Supply and run of 25mm x 3 mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. |
| 18 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 19 | GST@18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender