Educational and Research Institute Government Departments Closing in 5 days TDR #58374337

Tender For Renovation Of Newly Allotted Space Of Research Building (Room Nos. 705, 70,6 707, 708 At 7Th Floor) To Ccd Office At Iitg Campus.

Issued by Government Departments · Kamrup, Assam
Tender Value
88.13 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
5 days left
EMD
1.76 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Newly Allotted Space Of Research Building (Room Nos. 705, 70,6 707, 708 At 7Th Floor) To Ccd Office At Iitg Campus.

BOQ

Name of Work:- Renovation of newly allotted space of Research Building (Room nos. 705, 70,6 707, 708 at 7th floor) to CCD office at IITG campus.
Sl. No. Item Description
1Part-A: Civil Works
2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion
3Powder coated aluminium (minimum thickness of powder coating 50 micron)
4For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
5Powder coated aluminium (minimum thickness of powder coating 50 micron)
6Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
7Pre-laminated particle board with decorative lamination on both sides
8Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
9With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
10Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge
11Powder coated minimum thickness 50 micron aluminium
12Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm
13Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
14Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 300x16 mm
15Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x75x4 mm
16Providing and fixing partition upto ceiling height consisting of G.l. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.l. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete
1775 mm overall thickness partition with 12.5 mm thick double skin fire rated Cement Fibre board conforming to IS: 2095: part 3 (Board with BIS certification marks)
18Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing Gl wire etc. complete as per directions of Engineer-in-Charge.
19Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.l. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.l. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.l. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with
2012.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) sqm
21Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main T runners to be suspended from ceiling using G.l. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.l. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main T. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
22Cutting the existing crack in a V Shape groove cleaning the the same with proper means of application of one coat of EpoxyBonding agent followed by application of Sikha214 Non shrinkage powder over the entire crack area and let dry. Finally plaster the surface whenever required.
23Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.:
24Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour
25New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre
26Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
27Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
28rick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in
29Cement mortar 1:4 (1 cement: 4 coarse sand)
30Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
311:1.5:3 (1 cement : 1.5 coarse sand(zone-lll derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
32Centering and shuttering including strutting, propping etc. and removal of form for
33Weather shed, Chajjas, corbels etc., including edges
34Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
35Thermo-Mechanically Treated bars of grade Fe-500D or more.
3612 mm cement plaster of mix :
371:4 (1 cement: 4 fine sand)
38Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
39Providing and laying water proofing treatment in walls., by applying cement slurry mixed with water proofing cement compound consisting of applying(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
40Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
4115 mm nominal bore
42Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
4315 mm nominal dia Pipes
44Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
4515 mm nominal bore
46Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
4775 mm diameter
48Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:
49White glazed fire clay kitchen sink of size 600x450x 250 mm
50Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.
51With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm.
52Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
53Providing and fixing anodised aluminium grill anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
54Providing, fitting & fixing of polyester blackout sunflim as per direction of the engineer in charge (make Gareware)
55Providing and fixing 19 mm thick ply board including fixing, providing of bid at the edge, fitting and dismantling of damaged and disposing of damaged board as per direction of Engineer in charge . (Make- Everest, Century)
56Providing and fixing Sunmica laminated 1mm thick on ply board including fixing an fitting as per direction of Engineer in charge
57Part-B: AC Works
58Outdoor Unit
59Supply, installation, testing & commissioning of fully factory assembled Variable Refrigerant Volume type multi unit air-conditioning system inverter type complete with indoor and outdoor units with individual controller for cooling only operations.SITC of Variable Refrigerant Volume Outdoor Unit complete with hermitically sealed scroll compressor as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A or R407C , iii) Protective coated fins iv) Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquid, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point .All Inverter Scroll Compressor(s) with variable refrigeration evaporating temperature enabled feature in outdoor unit capable of inverter control with 6 pole compressor motor.The inverter compressor should be capable of changing the speed in accordance to the variation in cooling or heating load requirement, back pressure control mechanism for efficient operation in low-load condition.The outdoor unit should be fitted with low noise, aero spiral design fan with minimum External Static Pressure of 75 Pa for easy discharge of Hot air, aero fitting grille, to reduce pressure loss.The outdoor unit should be capable of automatic refrigerant charge function. The heat exchanger shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. The cost should be inclusive of Lifting, Shifting & Positioning of Outdoor Units to the installation platform
60Outdoor condensing Unit ( 40 HP) Nominal capacity
61Indoor Units- All with cordless remote
62Supply, installation, testing & commissioning of variable refrigerant volume modular type indoor units comprising of all accessories as per the specifications. The indoor units shall be suitable to work on cooling as well as heating mode.The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork as shown in the design drawings and dehumidified air quantity as mentioned in the heat load summary sheet under \\"Special Conditions\\" and the indoor units shall be of following capacities. SITC of Indoor VRV Ceilling Mounted High Static Flow Type Duct Unit with Independent Vane Control & varibale air flow as per following nominal capacities complete withi) Expansion and mixing arrangementsii) Power Supply interconnectionsiii) Controlling interconectionsiv) Piping interconnectionsv) Supending accessoriesvi) Insulated Drain pipe linevii) Receiver Kit(Sensor) of Duct AC
634 way Cassette Type Units (742 cfm/3.2HP)(nominal capacity)
64Hi Wall Type Units (1.0 HP)
65Hi Wall Type Units (1.25 HP)
66Hi Wall Type Units (1.5 HP)
67Refrigerant Piping (VRV System)
68Supply,installation,testing and commissioning of Interconnecting copper refrigerant pipe work with (25mm/19 mm thick) closed cell elastomeric nitrile rubber tubular insulation with factory fitted IC-CLAD glass cloth between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Outdoor assumed to Installed in the same Floor.
6941.30 mm O.D.(insulation : 25 mm) (Wall Thickness 1.0mm)
7034.90 mm O.D.(insulation : 25 mm) (Wall Thickness 1.0mm)
7128.58 mm O.D.(insulation : 25 mm) (Wall Thickness 1.0mm)
7222.20 mm O.D.(insulation : 25 mm) (Wall Thickness 1.0mm)
7319.10 mm O.D.(insulation : 19 mm) (Wall Thickness 1.0mm)
7415.88 mm O.D.(insulation : 19 mm) (Wall Thickness 1.0mm)
7512.70 mm O.D.(insulation : 19 mm) (Wall Thickness 1.0mm)
769.52 mm O.D.(insulation : 19 mm) (Wall Thickness 0.8mm)
776.40 mm O.D.(insulation : 19 mm) (Wall Thickness 0.8mm)
78Supply,installation,testing and commissioning of 2core X 1 mm2 copper wire in PVC conduit as per specifications ( for transmission and remotes)
79Supply, Installation,testing and commissioning of REFNET as per drawing and specifications
80Installation, testing and commissioning of OUTDOOR MULTI KIT as per drawing and specifications
81Supply,installation,testing and commissioning of CPVC drain pipes with 9 mm nitrile rubber insulatiions complete with supports as per drawings and specifications of below sizes
8250 mm dia
8340 mm dia
8432 mm dia.
8525 mm dia
86Cutting/chasing/drilling openeings and their subsequent repair work for passage of refrigerant pipes,condensate pipes,ducts etc. as per drawings and specifications
87Supply, Fabrication and Installation of MS structure of 40 HP VRV ODU as per drawings and specifications.
88Nitrogen flushing of entrire system
89Supply and charging of extra refrigerant (R-410A/R407C)(Top-Up) as per OEM specifications
90Part C: Electrical Works
91I- Schedule Items
92Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
932 X 4 sq. mm + 1 X 4 sq. mm earth wire
944 X 10 sq. mm + 2 X 6 sq. mm earth wire
952 X 16 sq. mm + 1 X 6 sq. mm earth wire
962 X 10 sq. mm + 1 X 6 sq. mm earth wire
97Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
986 A switch
993 pin 6 A socket outlet
10016 A switch
1016 pin 16 A socket outlet
102Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1031 or 2 Module (75mmX75mm)
1046 Module (200mmX75mm)
1058 Module (125mmX125mm)
106Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
1074 way (4 + 12), Double door
108Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
109Single pole (32 A)
110Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
111Group A
112LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
11336 watt
114LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim.
11518 watt
116Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.
117Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.
1181 Run of cable
119Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
120Telephone socket outlet
121Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
1222 Pair
123Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
12425 mm
125II- Non-Schedule Items
126Supplying and fixing of computer point RJ-45 modular type in compatiable box along with cover plate etc. complete make legrand or equivalent
127Supply and installation of 63 A, 16 kA 4 pole MCCB of approved make. (Make: L&T/Schneider/ABB/Legrand/Hager/Eqv)
128Supply and installation of 63 A, 10 kA, 4 pole MCB of approved make. (Make: L&T/Schneider/ABB/Legrand/Hager/Eqv)
129Supply and installation of 4 way metal enclosure of approved make. (Make: Legrand/Siemens/Schneider/L&T/ABB/Hager)
130Supply and installation of 5 star rated, 250 mm, exhaust fan of make- Havells/Crompton/Orient Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58374337
AUTHORITY Government Departments
TENDER VALUE 88.13 Lakhs
LAST DATE 19-11-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Renovation Of Newly Allotted Space Of Research Building (Room Nos. 705, 70,6 707, 708 At 7Th Floor) To Ccd Office At Iitg Campus.
Basic Detail
Tender No IITG/IPM/NIT/C/2026-27/69
Bidding Type Tender
Location
City Kamrup
State Assam
Key Dates
Publish Date 04 Nov 2026
Submission Date 19 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 88.13 Lakhs
Tender Fee 5000
EMD 1.76 Lakhs
Exemption Not Available
Document List
283799e4-6f16-445e-8cdd-aca6899590b6.html
BOQ_980558.xls
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

283799e4-6f16-445e-8cdd-aca6899590b6.html

xls

BOQ_980558.xls

pdf

NIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender