Housing Urban and Rular Development Government Departments Closing in 1 days TDR #58373933

Tender For Special Repairs To Leaky Roof, Water Supply, Sanitary Arrangements In Boys Toilet And Other Repair Works In Government Higher Secondary School At Pazhavoor In Tirunelveli District.

Issued by Government Departments · Tirunelveli, Tamil Nadu
Tender Value
3.95 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
1 days left
EMD
3960
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Leaky Roof, Water Supply, Sanitary Arrangements In Boys Toilet And Other Repair Works In Government Higher Secondary School At Pazhavoor In Tirunelveli District.

BOQ

Name of Work:- Special Repairs to Leaky roof, water supply, sanitary arrangements in Boys toilet and other repair works in Government Higher Secondary School at Pazhavoor in Tirunelveli District.
Sl. No. Item Description
1Clean removal of Cement plaster from walls
2Thorough scrapping of old plastered surface
3Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls - Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs
4Dismantling Clearing away and carefully stacking the materials useful for reuse Pressed tiles & weathering course
5Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls - Brick / stone masonry in Cement mortar walls under 3m high
6Dismantling RCC by manual / by using depolying machineries
7Fabricating, Supplying and fixing in position Mosquito net arrangements of Openable type. The Outer frame shall be made with Powder coated Aluminium Natural colour matt finishAluminium Hollow section of size 31mmx40mmx1.55mm. The Vertical center Mullion made with Aluminium Hollow section of size 55mmx11mmx1.55mm.The Horizontal and Vertical Aluminium Hollow section Shutter frame of size 31mmx13mm with a thickness of 1.55mm. The Mid Horizontal Aluminium Hollow section frame provided in the shutter with a size of 10mmx11mmx1.55mm. The Epoxy coated Stainless Steel 304 grade wire mesh with dia of 0.19mm shall be provided for Net. The U shaped Aluminium handle provided in the each shutter with a size of 19mmx26mm. The Connection Mechanism between Shutter and Outer frame that enables opening the Mosquito net. The Mosquito net arrangement should be fixed to the window with 100% packing with Screws, Silicon packing all around the frames with including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column/wall, masonry walls, Window frames, wherever necessary with drills to the required extent and make good to the original conditions after fixing and also as directed. All the Aluminium sections are to the powder coated with matt finish under electrically controlled conditions in accordance with relevant IS Code etc.complete complying with standard specification and as directed by the departmental officers.
8Labour wrought and put up in position Shutters for fully panelled doors (external or internal) moulded panels including labour charges for fixing furniture fittings complying with standard drawings and standard specification.
9Labour wrought and put up in position Shutters for Windows panelled including labour charges for fixing furniture fittings complying with standard drawings and standard specification.
10Earth work excavation for foundation by manual means for RR/Brick and Other step type footings for Load bearing structures in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
11Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means
12Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying,nsolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete multiplying with standard specification and as directed by the departmental officers. The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers
13Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
14Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers.
15Supplying and filling in foundation, basement, etc with filling stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
16Brick work in following Cement Mortar 1:5 using best quality country Brick of size 8 3/4\\" x 4 1/4\\" x 2 3/4\\" conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers.
17In Foundation and basement
18Fabricating, Supplying and fixing in position of steel sheeted windows ( Two Leaves) with the following specifications. Outer frames of windows made of ‘Z’ section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion ‘J’ section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 numbers of Steel Offset Pivot hinges of size 3” and one number of handle-Cu.m-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation.a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adjustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 200mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete complying with standard specification and as directed by the departmental officers.
19Providing and fixing of WPC door using door frame of the size 70mm x 50mm joined with 8 Nos of 50mm long screw. The door frames shall be fixed to the wall by using 80mm long screw through the frame. The WPC shutter 28mm thick factory made plain pre laminated hardware made out of ball bearing butterfly hinges -3nos, 200 mm tower bolt 2nos and 300 mm aldrop 1nos and 100mm D type handle 1 no for each shutter and ISI make Complete, including cost of materials conveyance and all other incidental charges and lobour charges for fixing the door neatly etc
20Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used curing etc. complete complying with standard specification and as directed by the departmental officers.
21Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
22Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
23Finishing the top of roof with one course of machine of Pressed Tiles of 230mm x 230mm x 16mm to 18mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
24Flooring with Plain Ceramic Tiles of size 305 x 305 x 6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
25Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
26Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
27Supplying and fixing in position of P.V.C water storage tank of best approved quality and brand of super thick with lid of 500 Capacity Litres with accessories including giving necessory connections etc., complete as directed by the departmental officers. ( The P.V.C. water storage tank should be got approved by the Executiove Engineer before use on works.)
28Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid. BGL
29110mm dia
30Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
31110mm dia Elbow
32Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - External water supply - above ground level
3325mm dia
3420mm dia
35Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements Since the labour for cutting, pasting, sundries have already been included under pipe line item of works, no separate provision for fixing PVC specials needs to be allowed.
3632mm dia PVC Bend
3732mm dia PVC Tee
3825mm dia PVC Tee
3920mm dia PVC Tee
4032mm dia PVC Elbow
4125mm dia PVC Elbow
4220mm dia PVC Elbow
43Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
44Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers.
45Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Interior Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
46Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Exterior Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
47Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
48Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers - 110mm dia
49Supply and fixing of flex banner of size 2' x 3' (2 feet x 3 feet) including necessary printing, cutting and fixing at the designated location using suitable adhesives etc., complete as directed by the departmental officer.
50GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58373933
AUTHORITY Government Departments
TENDER VALUE 3.95 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Special Repairs To Leaky Roof, Water Supply, Sanitary Arrangements In Boys Toilet And Other Repair Works In Government Higher Secondary School At Pazhavoor In Tirunelveli District.
Basic Detail
Tender No 12 (5) EE/2026-27 dated.03.11.2026
Bidding Type Tender
Location
City Tirunelveli
State Tamil Nadu
Key Dates
Publish Date 04 Nov 2026
Submission Date 18 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 3.95 Lakhs
Tender Fee Ref. Documents
EMD 3960
Exemption Not Available
Document List
BOQ_866793.xls
f9fad4bb-da3a-461e-816e-1bcdcdd96947.html
TC5.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_866793.xls

html

f9fad4bb-da3a-461e-816e-1bcdcdd96947.html

pdf

TC5.pdf

pdf

Tendernotice_1.pdf

Disclaimer