Tender for Special Repairs To Buildings Of Map Accn At Morar Cantt Under Ge Gwalior
BOQ
| Sl. No. | Item Description |
| 1 | Note: (i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department. |
| 2 | Taking down of old roof treatment of any description including mud phushka, concrete padding, tiles, cement plaster, old APP from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same outside of the MOD complete all as specified and directed. |
| 3 | M&L for repair of all visible hairline cracks on concrete roof / screed more than 0.50 mm thick and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size (10mm W x 6mm D). Fill cracks with PU sealant / Hybrid Sealant with suitable gun and smoothed with a putty knife or trowel. Allow sealant to cure a minimum (72 Hrs.) 3 days etc complete all as specified & directed. |
| 4 | M&L for Plain cement concrete 1:2:4 type B0 (using 12.5mm graded aggregate) for grading of roof for water treatment complete all as specified and as directed. |
| 5 | M&L for applying damp proof of approved make, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajjas in multiple coats @10.76 litre/ 10 sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof: water) and other coats to be applied undiluted. (ii) The undiluted 2nd & 3rd coatings needs to be reinforced with 40 GSM geotextile to be sandwiched between them. (iii) After that final 4th coating shall be applied. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete all as specified and as directed.Notes:-(a) The work shall be executed through authorised applicator of manufacturer only,(b) Authrised Applicator shall be approved by GE before starting of work.(c) All materials shall be procured directly form manufacturer.(d) The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Eight years in favour of GE. |
| 6 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner all as specified and as directed by engr-in-charge. |
| 7 | M&L the non shrink high mechanical strength properties epoxy based mortar @ 5kg/RM on all corner joints of wall to prevent the capillary formation from wall to roof area; by three component system comprising of base, hardener and quartz filler having ER Base and Hardener with Quartz filler etc complete all as specified & directed. |
| 8 | M&L for applying bonding agent for bonding old to new concrete surface likes chajja/ beam/ceiling/facia etc by high performance modified Styene- Butadiene Rubber (SSR) base binder. Applying of binder is as 10 Sqm/ per lits etc complete all as specified & directed. |
| 9 | M&L for applying 25 mm thick (average) repair mortar ready to use single component polymer modified repair mortar for repair of RCC members likes beams, columns, chajja and facia/ ceiling, mortar having good compressive strength and shrikage resistance etc complete all as specified & directed. |
| 10 | Taking down cement or cement lime plaster on brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc including disposal of debris/wastage to out side of MoD land complete all as specified and directed. |
| 11 | M&L for rendering 5 mm thick in cement plaster in CM 1:3 (1 cement : 3 Fine sand) on fair faces of concrete as in ceiling, finished even and smooth without using extra cement complete all as specified and directed. |
| 12 | M&L for 10 mm thick rendering in cement mortar (1:6) using coarse sand on fair faces of brick work of concrete surfaces of walls, finished even and smooth (without using extra cement) complete all as specified and directed. |
| 13 | M&L for Washed stone grit plaster on exterior walls in two layers, (i) under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, (ii) top layer 15mm cement plaster 1:1/2:2 (1cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern and colour including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately) complete as per specifications and direction of the Engineer-in-charge. |
| 14 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge. |
| 15 | M&L for preparation of new plastered surface of ceiling and applyying three coat of white wash complete all as specified and directed. |
| 16 | M&L for preparation of old surface plastered or unplastered and applying one coat of white wash on ceiling complete all as specified and as directed by Engr-in-Charge. |
| 17 | M&L White washing with lime to give an even shade with New work (three or more coats) on wall complete all as specified and directed. |
| 18 | M&L for preparation of old plastered/unplastered surfaces: Scrap off loose material using mechanical sanders or steel scrapers to Grade St 2. Apply one coat of water-based alkali-resistant primer on walls to neutralize lime content, ensuring the surface is dry (moisture<10%) before further application. and applying one coat of distemper oil emulsion using rollers of any colour complete all as specified and directed. |
| 19 | M&L for preparing old painted surfaces of walls and applying one coat of weather proof paint exterior antifungal acrylic emulsion paint on external surfaces of walls including necessary scaffolding and safety precautionscomplete all as specified and as directed. |
| 20 | Taking down eaves gutters and rain water pipes (any size 75mm to 110mm of any pattern) ,of any description and in any position, including all fittings , heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories) complete all as specified. |
| 21 | S&F for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls. complete all as specified. |
| 22 | S&F for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all specified. |
| 23 | S&F for 75mm PVC (SWR) couplers complete all as specified and directed. |
| 24 | S&F for 110mm PVC (SWR) couplers complete all as specified and directed. |
| 25 | S&F for 75mm dia PVC (SWR) pipes junction, single (single T/Y) equal or unequal any radious.with acces door, complete all as specified and directed. |
| 26 | S&F for 110mm dia PVC (SWR) pipes junction, single (single T/Y) equal or unequal any radious.with acces door, complete all as specified and directed. |
| 27 | 75 mm Bend with or without door |
| 28 | 110 mm Bend with or without door |
| 29 | S&F PVC SWR vent cowl 110 mmn dia |
| 30 | Taking up or down steel tubing and connection including cleaning for refixing or removing to store of 15mm bore of pipe, complete all as specified and directed. |
| 31 | Taking up or down steel tubing and connection including cleaning for refixing or removing to store of 20mm bore of pipe, complete all as specified and directed. |
| 32 | Taking up or down steel tubing and connection including cleaning for refixing or removing to store of 25mm bore of pipe, complete all as specified and directed. |
| 33 | Supplying and laying 20 mm dia of bore CPVC pipe SDR11 and Plain CPVC SDR11 fittings (ISI) marked, concealed or fixed to wall or laid in floors complete all as specified and as directed. |
| 34 | Supplying and laying 25 mm dia of bore CPVC pipe SDR11 and Plain CPVC SDR11 fittings (ISI) marked, concealed or fixed to wall or laid in floors complete all as specified and as directed. |
| 35 | S&F for Vitreous China, semi-pedestal pattern (Anglo-Indian Type) white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 36 | S&F for Vitreous china premium/ 1st quality wash down water closet floor mounted EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 37 | S&F for vitreous china toilet paper holder complete all as specified and directed. |
| 38 | S&F for 10ltr capacity (White) P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete all as specified and directed. |
| 39 | Supply and fixing of Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. |
| 40 | S&F for of Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 41 | S&F in repair Towel Ring of CP fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) all as specified and as directed. |
| 42 | S&F for in repair CP tubular towel rail D type 20mm dia and 60cm long complete all as specified and directed. |
| 43 | S&F for in repairs Soap dish of CP fixed with pvc rawal plugs and screw, complete all as specified and directed. |
| 44 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and as directed. |
| 45 | S&F in repair Vitreous China wash basin oval type white size 580 x 450mm excluding taps waste, chain and plug, but fixed waste pipe complete all as specified and directed. |
| 46 | S&F in repair of 32mm size Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed. |
| 47 | Providing and fixing 15mm dia nominal bore 450mm long uPVC connection pipe with brass unions complete all as specified and directed. |
| 48 | S&F in repair CP fancy type bib tap cast copper alloy with crutch or butter fly handle (Long Body), screwed down for iron pipe 15 mm bore of tubing complete all as specified and directed |
| 49 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 50 | S&F in repair 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified. |
| 51 | S&F in reapir 15 mm bore brass CP wall mixer for mixing hot & cold water with shower controlled (3 in 1 wall mixer) screwed down for iron pipe and fixed complete all as specified and directed. |
| 52 | S&F in repair stop cock/angle valve 15 mm nominal bore brass chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed |
| 53 | S&F in repair Brass chromium plated shower rose 125mm dial size with15 mm shower arm complete all as specified and directed |
| 54 | Providing and fixing in repair 25 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete all as specified and as direcetd. |
| 55 | S&F in reapir 15 mm bore brass CP Swan Neck Sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 56 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 57 | Supply and fixing 40mm dia flexible uPVC waste pipe for sink including PVC waste fittings complete all as specified and directed. |
| 58 | S&F in replacement stainless steel (Grade 304) kitchen plate rack made out of 0.63mm thick stainless steel of size 900x750 mm including screws and wt not less than 5.00 Kg complete all as specified and directed. |
| 59 | Providing and fixing 100mm CP grating for gully trap complete all as specified and directed. |
| 60 | S&F for in repair gun metal globe /valve with iron wheel head screwed both ends for iron pipe of 20mm bore, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 61 | S&F for in repair gun metal globe /valve with iron wheel head screwed both ends for iron pipe of 20mm bore, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender