Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #58373315

Tender For Repair/Replacement/Improvement Of Lt Electrical Panels Including Starters And Other Accessories And Standby Dg Set At Various Water Supply Installations And Connected Works In The Area Of Age (U) Water Supply No-Iii Under Ge(U) Water Suppl

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
47.88 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
17 days left
EMD
95760
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement/Improvement Of Lt Electrical Panels Including Starters And Other Accessories And Standby Dg Set At Various Water Supply Installations And Connected Works In The Area Of Age (U) Water Supply No-Iii Under Ge(U) Water Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR/REPLACEMENT/IMPROVEMENT OF LT ELECTRICAL PANELS INCLUDING STARTERS AND OTHER ACCESSORIES AND STANDBY DG SET AT VARIOUS WATER SUPPLY INSTALLATIONS AND CONNECTED WORKS IN THE AREA OF AGE (U) WATER SUPPLY NO-III UNDER GE(U) WATER SUPPLY DELHI CANTT-10
Sl. No. Item Description
1M/L maintenance and servicing of DG Set of any capacity complete by replacing the fuel filter, lubricating oil filter, replacement of air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour minimum at connected load and record shall be made in respect of RPM , oil pressure, oil temprature, coolant temprature, voltage, frequancy, load current, battery charging, fuel consumption & noise level etc complete all as specidied and directed. Note :- 1. Minor spare parts i.e. nut bolt, washer, petroleum jelly deemed to be included in the quoted unit rate of this item. 2. Major spare parts/Oil/Coolant etc will be measured and paid Seprately under respective of schedule 'A'. 3. DHPP will be issued by dept for testing only.
2160 to 320 KVA Capacity
3100 to 125 KVA Capacity
450 to 75 KVA Capacity (Note : For serial item no 1.01 to 1.03 Spares parts required shall be measured and paid separately under respective itms of Schedule as supply only.)
5Supply only of following items for DG Sets Capacity of 160 KVA to 320 KVA (Required under Sl item No. 1.01 above) :-
6Air Filter
7Fuel Filter
8Lubricating oil filter
9Supply only of following items for DG Sets Capacity of 100 ot 125 KVA (Required under Sl item No. 1.02 above) :-
10Air Filter
11Fuel Filter
12Lubricating oil filter
13Supply only of following items for DG Sets Capacity of 50 to 75 KVA (Required under Sl item No. 1.03 above) :-
14Air Filter
15Fuel Filter
16Lubricating oil filter
17Supply & fixed in repair of Hose pipe set & Clips of water / coolent cooled radiator system for following capacities of DG set :-
1850 KVA to 75 KVA DG set
19100 KVA to 125 KVA to DG set
20160 KVA to 320 KVA DG set
21Supply and fixing in repair of following items for DG Sets Capacity of 160 KVA to 320 KVA
22Diesel return pipe
23Ignition switch for starting DG set with key.
24Diesel Fuel Hose pipe from diesel tank to fuel filter
25Fuel injector pipe from fuel pump to Injector
26Supply and fixing in repair of following items for DG Sets Capacity of 100 KVA to 125 KVA
27Diesel return pipe
28Ignition switch for starting DG set with key.
29Diesel Fuel Hose pipe from diesel tank to fuel filter
30Fuel injector pipe from fuel pump to Injector
31Supply and fixing in repair of following items for DG Sets Capacity of 50 KVA to 75 KVA
32Diesel return pipe
33Ignition switch for starting DG set with key.
34Diesel Fuel Hose pipe from diesel tank to fuel filter
35Fuel injector pipe from fuel pump to Injector
36Disconnection and dismantling the fuel injector pump assembly from its original position, repairing & servicing by cleaning / oiling / servicing of fuel injector pump assembly , removing and replacement fuel injector pump repair kit & fuel pipe including calibration complete & refixing the same complete all as specified and directed for following capacities of DG set :-
37160 KVA to 320 KVA DG Set
38100 to 125 KVA KVA Capacity
3950 to 75 KVA Capacity
40Dismantling and taking down radiator assy from engine of any capacity of repairs etc transporting of the radiator of capacity upto 320 KVA for repair/maintenance of rediator fins with the help of cleaning coil solution and cleaning to the radiator complete and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, repair to the leakage places by means of gas welding and including initial filling up coolant and re fixing after repairs including replacement of worn out nut bolts washers etc and testing complete all as specified and directed
41Dismantling the water pump for the DG Set taking out the worn out parts, refixing the water pump after replacing water pump kit set for following capacities of DG set:-
4250 KVA to 75 KVA DG set.
43100 KVA to 125 KVA DG set.
44160 KVA to 320 KVA DG set.
45S&F in repair of RPM meter of upto 320 KVA DG set complete all as specified and directed.
46S&F in repair of oil pressure Gauge of upto 320 KVA DG set complete all as specified and directed.
47S&F in repair of oil temperature Gauge of upto 320 KVA DG set complete all as specified and directed.
48S&F in repair of water temperature Gauge of upto 320 KVA DG set complete all as specified and directed.
49Taking out following defective parts from Alternator of DG sets and supply and fixing new parts including testing of DG set complete all as directed :-
50AVR unit complete suitable for 50 KVA to 75 KVA DG Set
51AVR unit complete suitable for 100 KVA to 125 KVA DG Set
52AVR unit complete suitable for 160 KVA to 320 KVA DG Set
53Disconnection and taking out the turbo charger assembly complete from the Engine of any make of 100 KVA to125 KVA DG Set and taking to workshop, strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory working complete all as specified and directed.
54M&L for replacement of fiexible coupling including coupling nuts, bolts & washers etc and proper alignment complete all as specified and directed at site suitable for DG sets of capacity :-
55160 to 320 KVA Capacity
56100 to 125 KVA Capacity
5750 to 75 KVA Capacity
58M&L repair/overhauling of self starter 12/24 Volt of any make/Capacity including replacement of minor items such as carbon brushes, nuts blts etc, complete all as specified directed for fully functional of self starter complete. (Note: All additional spares parts as required will be measured and paid separately as supply only)
59Supply only spares parts suitable for self starter 12/24 V as mentioned below:-
60Field coil
61Armature
62Clutch assembly
63Supply & fix in repair of self starter assembly 24 volt complete for 100 KVA to 125 KVA DG set complete
64Supply & fix in repair of self starter assembly 12 volt complete for 50 KVA to 75 KVA DG set complete
65M&L cleaning oil fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings of suitable quantity of OEM recommendation complete all as specified and directed.
66S&F in replacement of Battery 12V 140AH complete all as specified and directed.
67S&F in replacement of Battery 12V 120AH complete all as specified and directed.
68S&F in replacement of Battery 12V 60AH complete all as specified and directed.
69M&L battery lead copper conductor 25 Sqmm multi stranded PVC insulated with suitable terminals at both ends as per site requirement complete all as specified and directed.
70Supply and replaced 'V belt' as per sample for DG sets of following capacity complete all as specified and directed
7150 to 75 KVA Capacity
72100 to 125 KVA Capacity
73160 to 320 KVA Capacity
74Dismantling of alternator assembly of DG Set of capacity upto 125 KVA and taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed.
75Dismantling of alternator assembly of DG Set of capacity exc 125 KVA but upto 320 KVA and taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed.
76Draining out the old u/s oil from the engine of DG set of any capacity cleaning the oil chamber and supply and filling new lubricant GENSET OIL complete all as directed and specified. (Note: Lubricant oil shall be procured from approved make and in sealed container)
77Supply and replacement coolant of approved make suitable for DG sets complete all as directed and specified. (Note: Lubricant oil shall be procured from approved make and in sealed container)
78M & L for for repair of DG Control Panel of any description and in any position of capacity DG Set upto 200 KVA including checking AC/DC circuits, tightning of all power / control wiring connection and replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to makefunctional including testing complete all as specified .
79Material and labour for plate earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead 32mm x 6mm strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all surrounded by adequete quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, earth strip encased in 40 mm bore GI medium grade pipe, including providing watering pipe 20 mm bore GI pipe medium grade from bottom of the earth pit to the top of the electrode complete with earth pit in PCC 1:2:4 type B - O using 12 mm graded crushed stone aggregate, earth work and RCC cover Complete all as specified and shown in electrical plate number 3 of SSR part -1, incl dismantlimg of existing earth pit complete all as specified and directed. (Note: GI earth strip upto 7.5 RM from the test point shall be deemed included in quoted unit rate.)
80M&L maintenance/repair at LT Control panel including cleaning in side the panel, tightening of all connection complete installed at pump house for centrifugal pump set/ borewell at different places in the area and replacement of spare parts as required during maintenance. (Note: Spare part will be measured and paid seperately under relevent item as supply only) complete upto 75 HP motor pump set (once in a month) with FASD starter and MCCB.
81Material and labour for removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth from the existing suction/ delivery pipe line including headers of any size and applying of painting to existing surcface by using spray gun with one coat of red oxide and two coat of synthetic enamel paints on existing suction/ delivery pipe lines, including Headers of any size using Blue/Red/Black colour as per site requirement complete all as specified and as directed.
82S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 350 Amp with breaking capacity 36 KA complete all as specified and directed
83S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 250 Amp with breaking capacity 36 KA. complete all as specified and directed
84S&F in replacement moulded case circuit breakers 3 Pole 415 Volt adjustable type 200 Amp with breaking capacity 36 KA. complete all as specified and directed
85S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 160 Amp with breaking capacity 36 KA. complete all as specified and directed
86S&F in replacement moulded case circuit breakers 3 pole 125 Amps having breaking capcity 16 KA at 415 volts. complete all as specified and directed
87Supply & Fixing in replacement MCCB 100 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed.
88Supply & Fixing in replacement MCCB 63 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed.
89S&F in replacement offload changeover switch 4 pole 100 Amps in sheet enclosure compete all as specified and directed
90S&F in replacement offload changeover switch 4 pole 250 Amps in sheet enclosure compete all as specified and directed
91S&F in replacement offload changeover switch 4 pole 320 Amps sheet enclosure compete all as specified and directed
92S&F in replacement offload changeover switch 4 pole 400 Amps sheet enclosure compete all as specified and directed
93S&F in replacement 3 pole power contactor ML-3, 28-42 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed
94S&F in replacement 3 pole power contactor ML-02, 20-32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed
95S&F in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and directed
96S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD complete all as specified and directed
97S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-2 FASD complete all as specified and directed
98Supply and fixing in replacement of fully automatic star delta starter type ML-3 complete all as specified and directed
99M&L in replacement of single phase preventor type VSP-II complete all as specified and directed
100S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Analog Type complete all as specified and directed
101S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Analog Type complete all as specified and directed
102S & F in replacement of Voltmeter selector switch 3 pole 415 Volts, Complete all as specified and directed
103S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Digital Type complete all as specified and directed
104S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Digital Type complete all as specified and directed
105S & F in replacement of single phase indicator lamp LED type assembly as per site requirement complete.
106M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 1.5 Sq mm complete all as specified and directed
107M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 2.5 Sq mm complete all as specified and directed
108S&F in replacement of thermal over load relay type ML-1.5 relay range 10-16 Amps complete all as specified and directed
109S&F in replacement of thermal over load relay type ML-2 relay range 20-32 Amps complete all as specified and directed
110Material and labour for painting to existing surcface of NRV,sluice valves/Strainers valves of capacity 80 mm to 150 mm by using spray gun with one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below complete all as specified and directed. (Note: color shades are as under:- NRV colour - Black, Sluice Valve colour - Black)
111Supply, Installation, commissioning and testing of Retrofitting of emission contro device/Equipements omn DG Set of 200 KVA at STP Shankar Vihar of any make alternator having a minimum specified particulate matter capturing efficiency of at least of 75% in 5 mode D2 cycle, reduction efficiency of CO, HC and PM 2.5 & 10.Notes :- (i) System to be robust enough for cold start and startup oil emission such that there is no impect on overall maintenance cycle timelines. (ii) Operating back pressure limit to be < 3.3 KPa at Rated Load. (iii) Maintenace cycle to be 5-6 months or 500 Hrs whichever is earlier. (iv) Noise levels to be within CPCB guidelines without silencer. (v) Passive regeneration to be achieved with max 10% duty cycle above 25% load. (vi) Overall power consumption to be lower than 1% of DG Rated Power. (vii) The Emission control device /Equipement must be tested over an ISO -8178 5 mode D2 Cycle for equivelent KVA rating at any of the CPCB coliance Govt approved laboratories .
112Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front side 415 Volts, 3 phase, 50 Hz having copper bus bar of capacity 630 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated and suitable to accommodate and supply and fixing of the following complete all as specified and directed :Incoming :-(a) MCCB 400 Amp, 4 pole, 415 Volts, 50 HZ 36 KA -01 Nos.(b) Changeover Switches 4 pole 415 volts 400 Amps - 01 No Outgoing :-(a) MCCB 100 Amp, Three pole, 415 Volts, 50 HZ 25 KA -03 Nos.(b) MCCB 160 Amp, Three pole, 415 Volts, 50 HZ 25 KA -01 Nos.(c) MCCB 63 Amp, 4 pole, 415 Volts, 50 HZ 16 KA -01 Nos.(d) Soft starter suitable for 40 HP Centrifugal Pump Set 75A 208 to 690V including cooling arrangement for soft starter complete - 03 Nos.(e) Soft starter Suitable for 75 HP Centrifugal Pump 140A 208 to 690V including cooling arrangement for soft starter complete - 01 No.(d) Digital Voltmeter 96x96 Sqmm 0-500 Volts with selector switch - 05 Nos
113(e) Digital Ampere meter 0-200 Amp 3 Phase, 96x96 Sqmm with CT ratio 200/5 - 05 Nos (f) Indicator lamp LED type of (R,Y,B) set of 12 No
114Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front side 415 Volts, 3 phase, 50 Hz having copper bus bar of capacity 630 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated and suitable to accommodate and supply and fixing of the following complete all as specified and directed :Incoming :-(a) MCCB 400 Amp, 4 pole, 415 Volts, 50 HZ 36 KA -01 Nos.(b) Changeover Switches 4 pole 415 volts 400 Amps - 01 No Outgoing :-(a) MCCB 200 Amp, Three pole, 415 Volts, 50 HZ 25 KA -03 Nos.(b) MCCB 160 Amp, Three pole, 415 Volts, 50 HZ 25 KA -01 Nos.(c) Soft starter suitable for 40 HP Centrifugal Pump Set 75A 208 to 690V including cooling arrangement for soft starter complete - 03 Nos.(d) Digital Voltmeter 96x96 Sqmm 0-500 Volts with selector switch - 05 Nos(e) Digital Ampere meter 0-200 Amp 3 Phase, 96x96 Sqmm with CT ratio 200/5 - 05 Nos (f) Indicator lamp LED type of (R,Y,B) set of 12 No
115Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with ventilations, weather, dust and vermin proof with front opening and locking arrangement on front side 415 volts, 3 phase, 50 Hz having copper bus bar of capacity 630 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakable with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B-1, MS channels for base frame 50x50x6mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated and suitable to accommodate and supply and fixing of the following complete all as specified and directed : INCOMING:-(a) MCCB 400 Amp, 4 pole, 415 Volts, 50 HZ 36 KA -01 No. (b) Changeover Switches 4 pole, 415 volts 400 Amps -01 OUTGOING :- (a) MCCB 200 Amp, 3 pole, 415 Volts, 50 HZ 25 KA - 03 Nos (b) MCCB 160 Amp, Three pole, 415 Volts, 50 HZ 25 KA -01 Nos.(c) Soft starter suitable for 40 HP Centrifugal Pump Set 75A 208 to 690V including cooling arrangement for soft starter complete - 03 Nos.(d) Digital Voltmeter 96x96 Sqmm 0-500 Volts with selector switch - 05 Nos(e) Digital Ampere meter 0-200 Amp 3 Phase, 96x96 Sqmm with CT ratio 200/5 - 05 Nos (f) Indicator lamp LED type of (R,Y,B) set of 12 No
116An amount of Rs 1,01,587.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58373315
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.88 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement/Improvement Of Lt Electrical Panels Including Starters And Other Accessories And Standby Dg Set At Various Water Supply Installations And Connected Works In The Area Of Age (U) Water Supply No-Iii Under Ge(U) Water Supply Delhi Cantt-10
Basic Detail
Tender No GE/WS/Token No-65 OF 2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 04 Nov 2026
Submission Date 26 Nov 2026
Open Date 28 Nov 2026
Finance
Tender Value 47.88 Lakhs
Tender Fee 500
EMD 95760
Exemption Available
Document List
2f8859a4-d3ed-4e7f-b666-501bd2bc85bd.html
BOQ_894236.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Nov 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

2f8859a4-d3ed-4e7f-b666-501bd2bc85bd.html

xls

BOQ_894236.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender