Tender For special Repairs To Building No. P-210, P-220 And P-223 Mt Shed And Garages At Mil Stn Dhrangadhra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Nov 2026
5 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Surendranagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repairs To Building No. P-210, P-220 And P-223 Mt Shed And Garages At Mil Stn Dhrangadhra
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old cement plaster any description on brick or stone wall/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete as specified and directed. |
| 2 | Demolition of Brickwork or stone/ boulder masonry, built in CM including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 3 | M & L for walling of random rubble, uncoursed well bounded, bedded and solidly hearted, built in Cement Mortar 1:6 complete all as specified and directed. |
| 4 | M & L for walling (Except stone) of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6 complete all as specified and directed. |
| 5 | Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc 20mm for sand stone and dressing to face stones and dressing of face beds and joints as specified ,of random rubble walling ,uncoursed or brought upto courses completed as specified and directed. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 7 | M&L for Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre ,including mixing Polyester Relince Recron 3S, 125 gram /50 kg Cement , thickness of concrete 25 cm or less, including complete Form work all as specified and directed. |
| 8 | M&L for Forming 12mm thick Expansion joints in 150 mm thick slab , filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' and provided with 20mm dia mild steel dowel bars 50cm long (25cm in each slab) with ferrules, spaced at 300 mm centres, including boring from work and preformed filler for dowels complete as specified and directed. |
| 9 | M&L for Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound grade 'A' complete as specified and directed. |
| 10 | Finishing surface to concrete roads, pavements, by brooming complete as specified and directed. |
| 11 | Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars complete as specified and directed. |
| 12 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:4 and finishing even and smooth without using extra cement complete all as specified and directed. |
| 13 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:6 and finishing even and smooth without using extra cement complete all as specified and directed. |
| 14 | Preparing of plastered or unplastered old decorated surfaces of walls by complete removal of existing treatment, moulds, moss and efflorescent salt and treating oil and greasy spots and applying three coat of white wash on walls including cornices etc complete all as specified and directed |
| 15 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed. |
| 16 | M&L for preparation of old plastered surfaces of wall and applying one coats of cement base paint complete all as specified and directed. |
| 17 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone for embedding of hold fast ,filling etc complete all as specified and directed. |
| 18 | Demolition of reinforced cement concrete in any position not exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 19 | M&L for RCC 1:1.5:3 type A-1 as in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like including demolition of existing RCC work in any position complete all as specified and as directed. |
| 20 | Use and waste of form work to soffit of suspanded slab such as roof slab ,floor slab landing and similar work n exc 200mm thick (horizontally or sloping complete all as specified and as directed. |
| 21 | M&L for TMT bar 10 mm dia and over including cutting bending and binding with MS wire anealed dia not less than 0.9 mm conplete all as specified and as directed. |
| 22 | Dismantling plain or corrugated steel sheeting any gauge ,thickness ,including Nainital or similar pattern roof coverings complete as specified and directed. |
| 23 | M & L, Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in single length complete all as specified and directed. |
| 24 | M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter ,drip and straight flashing fixed with self tapping screws all as specified and directed. |
| 25 | S&F rolled mild steel section as in joist ,channel ,angle ,or tee sections, fixed independendently ,without connecting plates ,etc (cut to ordinary lengths i.e. Within 20mm of the length indicated)other connecting plates conforming to Fe-410, Gde E-250A all as specified and directed. |
| 26 | All as per item No 25 but fixing only complete as specified and directed. |
| 27 | M&L, preparing of new steel surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 28 | M&L, preparation old previously treated steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint on the steel surfaces, complete all as specified and directed. |
| 29 | Dismantling structure steel work including doors, gates etc. complete as specified and directed. |
| 30 | M&L for , false ceiling consisting of wall angles ,main T ,cross T all of size 25 mm X25mmX1.4mm thick power coated GI grid frame work jointed angle as directed and mild steel hooks not less than 4 mm dia with arrangement for adjusting heights of ceiling with and incl provision of 4 mm thick E boards sheet in panels of size 600mmX600mm with necessary off cuts and fixing arrangements for ceiling ,tube light fitting incl dismantling of existing false ceiling complete all as specified and as directed. |
| 31 | Dismantling floor ,hearth or wall tiling incl cement mortar bedding (but not backing) complete all as specified and as directed . |
| 32 | M & L, non skid White ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm, in floors over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed |
| 33 | M & L, glazed coloured ceramic tiles in vertical surface as in skirting & dado, 7 to 8 mm thick area exc 0.05 Sqm but n.exc 0.18 Sqm over and including 10 mm thick rendering in CM1:4 set & jointed in neat cement slurry & pointed in coloured cement to match complete all as specified and directed. |
| 34 | S&F framed work as in doors of Garage or gates of angle or other sections with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc confirming to grade Fe-410-w(Gde -E-250)Quality A all as specified and directed. |
| 35 | Demolition of precast concrete articles and pre-cast cement concrete block walling, ashlar fencings, dressed stone work including all quoins, arches, pillars etc. built in cement mortar complete all as specified and directed. |
| 36 | M&L, precast cement concrete Block Masonary with solid blocks type C1, 1:3:6 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed . |
| 37 | M&L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded Stone aggregate) as in plinth protection finisheed with out using extra cement complete. |
| 38 | M&L, providing cement concrete1:2:4 type B1 as in , coping ,benching, bressumers, steps, incl necessary form work and demolition of existing cement work complete all as specified and as directed. |
| 39 | Taking down carefully copper/aluminium point wiring (Light, fan, socket or power etc.) complete including fitting such as switches, socket, bell pushes, ceiling roses, pendants/batten holder, call bell, regulators etc all as specified and directed by Engr-in-charge. |
| 40 | M&L for point wiring for one light/fan/bell point controlled by one switch one way in & including PVC conduit concealed in brick or stone wall using FRLS PVC unsheathed multistrand copper conductor wire 1.5 sqmm single core for one light/fan point controlled by one switch including modular white cover plate with frame of suitable modules over modular metal flush box concealed type for earth continuity insulated PVC unsheathed (green colour) 1.5 sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engr-in-charge. Note : (a) wiring shall be done by using proper colour coding. |
| 41 | All as per srl item No. 40 here-in-before but for 6 Amp socket outlet on independent board complete all as specified. |
| 42 | All as per srl item No. 40 here-in-before but for 6 Amp socket outlet on same board complete all as specified. |
| 43 | All as per srl item No. 40 here-in-before but for 6/16 Amp independent socket outlet using 2.5 sqmm single core wire (for phase, nuetral and earth) complete all as specified. |
| 44 | S&F modular switch piano, flush type 6 Amps one way 230 volts complete all as specified. |
| 45 | S&F modular socket outlet 2-3 pin 6 & 16 Amps flush type 230 volts complete all as specified. |
| 46 | S&F modular switch one way 16 Amps flush type 230 volts complete all as specified. |
| 47 | S&F modular socket 3 pin 6 Amps flush type 230 volts complete all as specified. |
| 48 | S&F ceiling rose 3 terminal size 50x65mm surface type 230 volts complete all as specified. |
| 49 | S&F, modular fan step type regulator, suitable for 1200mm/1400mm sweep ceiling fan, 2 module complete all as specified and directed. |
| 50 | S&F, Sheet metal enclosure double door for DB's SPN 8 way 240 V having 200 A rated bus bar complete all as specified and directed by Engr-in-charge. |
| 51 | S&F MCB SPN 32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge. |
| 52 | S&F MCB SP 6-32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge. |
| 53 | S&F 30W New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 for bldg security light with GI pipe bracket of suitable size for fitting complete all as specified and directed by Engineer-in-charge. |
| 54 | M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth Lead 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 20 mm dia light grade GI pipe & watering pipe shall be 15 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 15 mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 20 mm bore light grade 7.5m. |
| 55 | S&F ceiling fans 1200mm sweep energy efficient five star rated 230 volts with brushless direct current motor (BLDC) with blades, down rods, electronic regulator control type including down rods and connecting up with 3 runs of suitable size single core PVC insulated but unsheathed, FRLS cable with multistanded copper conductors from ceiling rose to fan complete all as specified and as directed. Make : Havells/Bajaj/Crompton |
| 56 | S&F LED compact fitting/batten for single LED tube of 1x20W, 220V, AC decorative box type 4ft with integral LED driver including 20W, T8 tube rod complete all as directed by Engr-In-charge. |
| 57 | S&F LED Adore Lamp 9W, B22 base 6500K CDL type complete all as directed by Engr-In-charge. |
| 58 | S&F Holder insulated body with back plate for batten fitting suitable for LED lamp complete all as specified and directed by Engineer-in-Charge. |
| 59 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe of size 4mm dia galvanised iron complete as specified and directed. |
| 60 | Taking down carefully old unserviceable main switches/ Distribution board any type including fuses MCB etc after removing all connection, wires and making good the disturb surface complete all as directed by Engineer-in-charge. |
| 61 | Supply, laying in trenches or passing through pipes and testing cable XLPE Insualted screened PVC bedded, galvanised steel strip or wire armored, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 Core . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender