Tender For Supply Installation Testing and Commissioning of Ac Machines At Dtc Medicines Storage Room ,J.D. Hospital,Cooch Behar
Tender Value
1.37 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
6 days left
EMD
2751
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coochbehar → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of Ac Machines At Dtc Medicines Storage Room ,J.D. Hospital,Cooch Behar
BOQ
| Sl. No. | Item Description |
| 1 | SUB HEAD-Distribution Wiring |
| 2 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 3 | 20 mm |
| 4 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 5 | 3 x 4 sq. mm |
| 6 | SUB HEAD---Plugs |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess (As per direction of the EIC), including providing and fixing 6 pin 15/16 A modular socket outlet and connections etc. as required. |
| 8 | SUB HEAD-SITC of AC Machines |
| 9 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) |
| 10 | warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only |
| 11 | 1.5 TR with 5 Star BEE Rating |
| 12 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for High wall Slplit/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 13 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 14 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 15 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 16 | S&F of 250V, 25A timer controlled single starter for controlling compound lights/ Single Air Conditioning Machines in SS double door 2+10 way DB enclosure (L&T/ABB/ Legrand make) with S&F following electrical accessories & front door locking arrangement with allconnections by finishing the ends of 2 x 4 & 1 x 2.5 mm copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl.necessary connections as per direction of EIC:- |
| 17 | 25A DP MCB (L&T / ABB / Legrand make) - 1 no. |
| 18 | 24Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) - 1 no. |
| 19 | 3-pole power contactor (L&T make Cat no MNX22 / 250V)-1 no. |
| 20 | 2-Modular AC motor starter (Legrand / Myrius Cat no 673031) -1 no. |
| 21 | 1-Module 10A Modular switch (Make Legrand / Myrius) - 1 no. |
| 22 | 3-module plate with cover (Make Legrand / Myrius) - 1 no. |
| 23 | 25A Auto-Off-Bipass SPDT toggle switch (approved reputed make) - 1 no. |
| 24 | LED indication lamp (approved reputed make) - 1 no. |
| 25 | Outgoing bakelite connector 32A (Reputed make as approved by EIC) - 2 nos. |
| 26 | Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender